MYERS

MODELS 4WHV & V4WHV


4" SOLIDS HANDLING WASTEWATER PUMPS
HORIZONTAL AND VERTICAL DISCHARGE
WWW.FEMYERS.COM
SOLIDS HANDLING WASTEWATER PUMPS

MYERS MODELS 4WHV & V4WHV


®

4" Solids Handling Pumps


Ideal for Light to Medium Commercial Installations
The 4WHV and V4WHV series solids handling pumps are designed primarily for
commercial applications such as schools and churches, industrial plants, shopping
centers, apartments and condominiums, marinas, interstate rest stops, sewage
collection systems, campgrounds, motels, restaurants, office and commercial
buildings, state and federal parks, hospitals and nursing homes, dewatering, trailer
parks and treatment plants.

This pump can be installed on legs (vertical discharge) or with a quick-disconnect


slide rail system. Its ability to handle 3-inch spherical solids makes it ideal for most
light to medium commercial installations.

Product Capabilities Construction Materials


Capacities To 720 gpm 45.5 lpm Motor Housing, Seal Housing, cast iron, Class 30,
Heads To 59 ft. 17.9 m Cord Cap and Volute Case ASTM A48
Solids Handling (dia.) 3 in. 76 mm Enclosed 2-Vane Impeller ductile iron, Class 65, ASTM A536
Liquids Handling raw unscreened sewage, effluent, storm water Power Cord SOOW, W
Intermittent Liquid Temp. up to 140˚F up to 60˚C Control Cord SOOW
Winding Insulation Temp. (Class B) 311˚F 155˚C Mechanical Seals: double tandem, type 21
Motor Electrical Data 1750 RPM Standard carbon and ceramic
(Single phase motors are capacitor start type. Myers control panels or 3–5 HP, 230V, 1Ø, 60 Hz Optional tungsten, carbide
capacitor kits are recommended for proper operation and warranty.)
3–10 HP, 208/230/460/575V, Pump, Motor Shaft 416 SST
3Ø, 60 Hz Fasteners 300 Series SST
Std. Third Party Approvals CSA Wear Ring brass
Acceptable pH Range 6–9
Specific Gravity .9 – 1.1
Viscosity 28 – 35 SSU
Discharge, Flanged Centerline (Horiz. or Vert.) 4 in. 101.6 mm
Min. Sump Diameter
Duplex 60 in. 1.5 m
Note: Consult factory for applications outside these recommendations.

2
SOLIDS HANDLING WASTEWATER PUMPS

Pump Features and Applications

C. Motor Stator High Efficiency Hydraulic Design


Shrunk in shell for perfect alignment and Cuts Pumping Costs and Extends
best heat transfer. Oil-filled for continuous
lubrication of bearings and seals. Life of Fluid End Components.
• Two-vane rounded port impellers handle solids
A with ease at high operating efficiencies.
D. Heavy Stainless Steel Shaft
Prevents deflection from impeller radial • Modified constant velocity volute offers quiet
loads when pump operates at heads higher operation, low radial loads over extended portion
than peak efficiency range. of performance curve.

B
E. Double Tandem Shaft Seals Durable Motor Will Deliver Many
C
Protect motor, operate in clean oil.
Years of Reliable Service.
• Oil-filled motor for maximum heat dissipation
F. Seal Leak Probe and constant bearing lubrication.
D Detects water in seal housing.
Activates warning light in control panel. • Heat sensor thermostats embedded in windings
E protect motor from overheat conditions.
F G. Pump-Out Vanes • Seal leak probe in seal chamber warns of
Help keep trash from seal, reduce pressure moisture entry; helps prevent costly motor
at seal faces. burnout.
G
H
I H. Horizontal Discharge
J
Volute Case
4" flanged.
VERTICAL DISCHARGE VOLUTE CASE
(not shown)
A. Cable Entry System Includes support legs. 4" flanged.
Provides double seal protection. Cable jacket
sealed by compression grommet. Individual wires I. High Efficiency Impeller
sealed by epoxy potting. Two-vane rounded port,
solids handling design.
B. Heat Sensors on
Motor Winding J. Brass Wear Ring
Protect motor from burnout due to excessive heat Prevents rust buildup and reduces leakage
from any overload condition. Automatically resets and wear. Replaceable to restore original
when motor has cooled. running clearance and pump efficiencies.

WWW.FEMYERS.COM 3
Performance Data and Dimensions [Dimensions in mm]

1750 RPM 6-3⁄8"


[162] 6-3⁄8"
SOLIDS HANDLING WASTEWATER PUMP
[162]
Model: 4WHV-V4WHV 7-1⁄8"
Speed: 1750 RPM 7-1⁄8" [181] [181]
Discharge: 4" 12-3⁄4"
Max. Solids: 3" 9" Dia. [324]
[229]
Operation is recommended
within heavy dashed boundary.
5-5⁄8"
10-1⁄4" 5-5⁄8"
[143] [143]
[260]

10-1⁄4"
[260]
25-7⁄8"
4" Nom. [657]
29-3⁄8" Dia.
[746]
9" Dia.
[64]
11-1⁄2" [292]
4-5⁄8"
3-1⁄2" [117]
4"
Nom.
[89] 10-1⁄2" Dia.
[267]
Legs Optional

Pump performance is based on clear water (1.0 specific gravity @ 68°F) and pump fluid end (hydraulic) efficiency. Motor data based on 40°C ambient temperature.

Available Models Motor Electrical Data


Full Load Service Full Load NEC Code Service
Standard HP Volts Phase Hertz Start Amps Amps Factor Amps Full Load kW Start KVA KVA Letter Factor
4WHV30M4-21 3 230 1 60 106 17.5 21 4.5 24.4 4.8 K 1.2
4WHV30M4-03 3 208 3 60 86 15 18 5.0 30.9 5.4 M 1.2
4WHV30M4-23 3 230 3 60 52 12 14.4 4.6 20.7 4.8 H 1.2
4WHV30M4-43 3 460 3 60 26 6 7.2 4.5 20.7 4.8 H 1.2
4WHV30M4-53 3 575 3 60 25 5 6 4.6 25.1 5.0 K 1.2
4WHV50M4-21 5 230 1 60 153 34 41 6.7 35.2 7.8 H 1.2
4WHV50M4-03 5 208 3 60 140 21.6 26 8.0 50.4 8.6 M 1.2
4WHV50M4-23 5 230 3 60 125 18 21.6 7.6 49.7 8.4 L 1.2
4WHV50M4-43 5 460 3 60 62 9 10.8 7.6 49.3 8.4 L 1.2
4WHV50M4-53 5 575 3 60 45 7.2 8.6 7.6 44.8 8.4 K 1.2
4WHV75M4-03 7.5 208 3 60 221 32.2 37 10.2 79.5 11.6 M 1.2
4WHV75M4-23 7.5 230 3 60 164 28 32 9.7 65.3 11.1 K 1.2
4WHV75M4-43 7.5 460 3 60 82 14 16 9.7 65.3 11.1 K 1.2
4WHV75M4-53 7.5 575 3 60 75 11.2 13 7.6 74.6 11.1 L 1.2
4WHV100M4-03 10 208 3 60 221 37 37 12.7 79.5 13.9 J 1.0
4WHV100M4-23 10 230 3 60 164 32 32 12 65.3 13.0 H 1.0
4WHV100M4-43 10 460 3 60 82 16 16 12 65.3 13.0 H 1.0
4WHV100M4-53 10 575 3 60 75 13 13 11.7 74.6 13.7 J 1.0

Motor Efficiencies and Power Factor


Motor Efficiency % Power Factor %
Service Service
HP Phase Factor Load 100% Load 75% Load 50% Load Factor Load 100% Load 75% Load 50% Load
3 1 71 70 67 59 52 51 49 45
3 3 74 73.5 69.5 61.5 73 70.5 62.5 52
5 1 67.5 68 65 56 83 81 73 62.5
5 3 77 77 77 70.5 80 77.5 71 59.5
7.5 3 75 75 72.5 65 77 72 62 49.5
10 3 75 75 75 71 79 79 72 58

1101 MYERS PARKWAY 490 PINEBUSH ROAD, UNIT 4


ASHLAND, OHIO 44805 CAMBRIDGE, ONTARIO, CANADA N1T 0A5
PH: 855-274-8948 PH: 800-387-4386 ORDERS FAX: 888-606-5484
WWW.FEMYERS.COM WWW.FEMYERS.COM
Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
K3240 08/07/17 © 2017 Pentair plc. All Rights Reserved.