Introduction:
A new connector link between PSIM and HyperStudy is created from v2024.1 to simulate and
study the PSIM schematics from the HyperStudy environment. The purpose of this feature is to
use the simulated output signals data in HyperStudy environment for design of the experiment
(DOE), optimization, and other post-processing of simulated data from PSIM.
Please note that connector link can be done with the HyperStudy v2024.0 onwards only.
Once the connection is done via “PSIM v2024.1 Utilities tool -> HyperStudy Setup”, one can use
the PSIM v2024.1 saved onward schematics files for the study in HyperStudy v2024.0 or
v2024.1.
© Altair Engineering, Inc. All Rights Reserved. / altair.com / Nasdaq: ALTR / Contact Us 2
Altair PSIM Tutorial / How to Use the PSIM-HyperStudy Connector Link
One can open the HyperStudy to test the connector link successfully. Please follow the
following steps to test the connector link:
Step 1: Open the Altair HyperStudy. Click on File -> New Study.
Step 2: Save the “New Study” at your desired location in your system. The following window will
open with the option to “Add Model”.
Step 3: Click on the “Add Model”. This will pop up a dialog box to select PSIM. This will verify the
successful connector link, as shown below in the figure.
© Altair Engineering, Inc. All Rights Reserved. / altair.com / Nasdaq: ALTR / Contact Us 3
Altair PSIM Tutorial / How to Use the PSIM-HyperStudy Connector Link
• Video tutorial: Get started with automated design exploration with PSIM + Hyperstudy |
Altair Tutorial Video (youtube.com)
• Example link (Altair Community): Insights into Motor Drive Design: Analyzing Trends
and Long-Term Costs with PSIM and HyperStudy - HyperStudy, PSIM - Altair Products -
Altair Community
The following steps are shown for an existing example from the PSIM folder available here:
“\examples\Link to Altair Products\HyperStudy\llc_FIT".
This example goes through the steps on how one can run a LLC converter schematic (made
inside PSIM environment) from the HyperStudy environment.
Step 1: Open the Altair HyperStudy. Click on File ->Open Study. Navigate to “\examples\Link to
Altair Products\HyperStudy\llc_FIT” inside the PSIM folder.
© Altair Engineering, Inc. All Rights Reserved. / altair.com / Nasdaq: ALTR / Contact Us 4
Altair PSIM Tutorial / How to Use the PSIM-HyperStudy Connector Link
© Altair Engineering, Inc. All Rights Reserved. / altair.com / Nasdaq: ALTR / Contact Us 5
Altair PSIM Tutorial / How to Use the PSIM-HyperStudy Connector Link
Step 5: Import variables using clicking on “Import” tab. The following dialog box
will pop up.
© Altair Engineering, Inc. All Rights Reserved. / altair.com / Nasdaq: ALTR / Contact Us 6
Altair PSIM Tutorial / How to Use the PSIM-HyperStudy Connector Link
Click on top right at HyperStudy symbol to complete the import of the variable.
Step 6: Click Next. One will see the following window with the selected active
input variables. The selected input variable will be in the range of 10% lower to
upper bound from the nominal value.
© Altair Engineering, Inc. All Rights Reserved. / altair.com / Nasdaq: ALTR / Contact Us 7
Altair PSIM Tutorial / How to Use the PSIM-HyperStudy Connector Link
Step 7: Click on “Run Definition” to write, execute, and extract the simulation output data.
After successful “Run Definition”, you will see the following window with green check box on
each column.
Step 8: Once the “Run Definition” is done, click Next. This will bring the next dialog for Output
definition -> Define Output Responses.
© Altair Engineering, Inc. All Rights Reserved. / altair.com / Nasdaq: ALTR / Contact Us 8
Altair PSIM Tutorial / How to Use the PSIM-HyperStudy Connector Link
Once your output response is defined, then you can click on next for “Evaluation Tasks”. One
can see evaluation of data, plot, scatter under the Evaluation Tasks:
This will conclude the entire “Definition” setup for this llc_fit project. One can use the this
“Setup->Definition” for further Fit model study, design of experiment (DOE), parameter sweep
analysis, optimization, etc. Please refer to the attached link above of the tutorial and example