You are on page 1/ 2

I/T CURVE:

Firing-Rev.3
Automatic definition of the Intensity / Time curve for partially denervated muscles. Automatic calculation of rheobase (minimal electrical amplitude of infinite
duration that results in the contraction of a muscle), chronaxie (minimum time over which an electric current double the strength of the rheobase needs to be applied,
in order to stimulate a muscle fiber or nerve cell) and accommodation index. Possibility of saving the I.T. curve in the database.

Here is a sample of an I.T. curve:

STIMULATION MODES:
Tens: It features many resident programs for most common
pathologies. Frequency: 2÷200 Hz. Pulse duration: 50÷600 µs.
Intensity: 0÷250 mA (Ipp).
FM: rectangular bidirectional symmetrical pulses. Sweep adjustable
from 2÷10 Hz. Duration of pulses adjustable.
FIRiNG EVO
Diadynamic currents: single-phase (MF), two-phase (DF), short-
Muscle: symmetrical bidirectional pulses. Features a file with a number period (CP), long-period (LP). Intensity: 0÷30mA (Ip).
of programs for the treatment of different muscle conditions. Frequency:
2÷200 Hz. Duration: 50÷600 µs. Intensity: 0÷250 mA (Ipp). Triangular/Exponential Pulses: triangular unidirectional pulses.
Duration: 1÷1000 ms. Pause: 1÷5 s. Intensity: 0÷30 mA.
Bipolar interferential current: amplitude-modulated square-wave
bidirectional current. Square-wave frequency: 4000 Hz. (± 20 %). Rectangular Pulses: rectangular unidirectional pulses.
Sinusoidal frequency of modulation: 5÷200 Hz. Intensity: 0÷250 mA
(Ipp).
Duration: 1÷1000 ms. Pause: 1÷5 s. Intensity: 0÷30 mA.
Agonist/Antagonist: rectangular bidirectional symmetrical pulses.
EXCEPTIONAL RANGE OF PRESET PROGRAMS
Tetrapolar interferential: amplitude-modulated bidirectional Stimulation agonists/antagonists muscles.
current. Sinusoidal frequency 2000÷5000 Hz. Sinusoidal frequency of
modulation 5÷200Hz. Intensity 0÷250 mA (Ipp) Agonist/Antagonist with Fardic current: unidirectional pulses.
Frequency: 1÷100 Hz.Intensity: 0÷130 mA (Ip).
Burst: rectangular bidirectional symmetrical pulses. Action: 0,25 s. • two fully indipendent channels
Pause: 0,75 s. Agonist/Antagonist with Kotz current: Interrupted sinusoidal
current. Sinusoidal frequency: 1000÷2500 Hz. Modulation frequency: • huge quantity of preset programs available
Kotz: Interrupted sinusoidal current. Sinusoidal frequency: 1000÷2500 5÷200 Hz. Intensity: 0÷250 mA (Ipp).
Hz. Modulation frequency: 5÷200 Hz. Intensity: 0÷250 mA (Ipp). • possibility of creating/saving your own programs
Diagnostics: recording of the intensity/time curve. Automatic
Traebert: rectangular, unidirectional current. Pulse duration: 2 ms. calculation of rheobase, chronaxie, accomodation coefficient and • high power output
Pause: 5 ms. Intensity: 0÷30 mA (Ip). drawing of the curve. Possibility to memorize the results and records it
on the database. • extremely simple to operate
AMF: rectangular bidirectional symmetrical pulses. Rise: 2 s. Fall: 1 s.
Rest: 2 s. High Voltage mod.: double unidirectional pulse. Polarity: positive or • SYSTEM: "multi parameters protocols"
negative. 200 V on 5 KOhm. 160 mA on 500 Ohm.
Faradic current: Unidirectional pulses. Frequency: 1÷100 Hz.
Intensity: 0÷130 mA (Ip). Urology: bidirectional symmetrical pulses. Frequency: 2 ÷ 200 Hz.
Pulse duration: 50÷600 µs. Maximum current: 250 mA (Ipp). Output
Iontophoresis: interrupted unidirectional current. characteristic: constant voltage (CV).
Frequency: 8000 Hz. Intensity: 0÷30 mA (Ip).

SYSTEM (multi parameters protocols):


It means Multi Parameters Protocols that are included in the FIRING stimulator equipped with a new generation microprocessor.
are extremely complex protocols that are reproducing the physiological muscular contraction. During the treatments, the energy levels of every
single phase, the dose frequencies, frequency sweeps, the frequency of the pauses are adjusted automatically and continuously during the program.

Here is a sample of a graphic system:

Iset + 11% Iset + 11% Iset + 11%

Iset Iset Iset Iset


Iset 150 µs 250 µs (I.M.) 250 µs (I.M.) 250 µs (I.M.) 250 µs (I.M.)

P 3 Hz P 3 Hz 150 µs 150 µs P 3 Hz P 3 Hz 150 µs 150 µs


150 µs (20”) (20”) (20”) (20”)
A 75 ↔ A 95 ↔ A 75 ↔ A 95 ↔
30 Hz 2 Hz ↔ 10 Hz 100 Hz 120 Hz 2 Hz 2 Hz 100 Hz 120 Hz 2 Hz 2 Hz
(10”) (10”) (10”) (10”)
40” 5’ (± 30”) 2’ (± 30”) 2’ (± 30”) 4’ (± 1’) 2’ (± 30”) 2’ (± 30”) 4’ (± 1’)

AC International s.r.l.
via Canapa 22 - 44042 Cento (FE) - Italy - Tel. +39 051 6836284 - Fax. +39 051 6831061 - www.cosmogamma.com - [email protected]
FIRING
(7F00) DUAL-CHANNEL ELECTROTHERAPY
FIRING is a the state of the art portable
stimulator for Physiotherapy/Rehabilitation.
Using the most advanced electronic
technology combined with the extremely
simple user interface, FIRING will satisfy
the most demanding physiotherapists.
Great attention was paid to the development
of complex algorithms monitoring operation at
any time.

In a modern and sleek design, the unit


is packed with INNOVATIVE features: Contraction
• A huge preset library of programs
for most pathologies. These programs
(together with the large number of
waveforms included in the machine) will
make FIRING the most comprehensive
toolkit available in the market.
• Possibility of creating and saving user-
defined programs.
• Patient database: store patient data
with treatment history.
• Two completely independent Contraction of agonists/antagonists muscles
channels individually programmable.
• Improved output power.
• Pain level evaluation for each recorded
patient at the beginning and at the end of
the treatment.
• Diagnostic analysis with Intensity/Time
(I/T) curve.(*)
• Perineal Treatments with preset
programs.
• Widest selection of currents / Combined stimulation with ultrasound
waveforms used both in rehabilitation
and pain therapy.(*)
TECHNICAL DATA OPTIONAL ACCESSORIES
• System: extremely complex
programs and protocols that will change Power supply: 115÷230 V~, 50-60 Hz • Ultrasound connection cable [13] (C/U)
frequency, duration pulse, sweep, rest/ Power input: 45 VA • Black cable with 2 mm plug [14] (C/RD-N)
action frequency, intensity and relax time. Weight: 3,8 Kg • Red cable with 2 mm plug [15] (C/RD-R)
All these parameters are automatically Dimensions (LxWxH): 27 x 32.8 x 23 cm • Point Electrode [16] (M/SP-P)
changed during the program without • Vaginal electrode [17] (EV/1)
Safety Class: I type BF (CEI EN 60601-1, CEI EN
operator intervention.(*) 60601-2-10) • Vaginal electrode [18] (EV/2)
• Creating and saving automatic • Vaginal electrode [19] (EV/3)
sequences i.e. groups of programs in • Vaginal electrode [20] (EV/4)
sequence. STANDARD ACCESSORIES • Anal electrode [21] (EL/A)
[23]

2 pcs. - Electrostimulation Cables [1] (C/IS) • Evoline bag [22] (A02.00241) [22]
• Connection to an ultrasound machine
available (optional cable required). 4 pcs. - Electrodes 60X40 mm [2] (EL/1) • Evoline trolley [23] (A01.00056)
2 pcs. - Electrodes 60X60 mm [3] (EL/2)
• Large high quality graphical monitor for 2 pcs. - Electrodes 60X120 mm [4] (EL/3)
better screen visibility. 4 pcs. - Pads for EL/1 [5] (S/1) [8]
• Immediate availability of a selection of 2 pcs. - Pads for EL/2 [6] (S/2) [6] [17]
[3]
"favorites" programs user defined. 2 pcs. - Pads for EL/3 [7] (S/3) [4] [7]
[19]
[11]
2 pcs. - Elastic straps 50 cm [8] (F6) [2] [5] [16] [18] [21]
Still, with all these features, FIRING 2 pcs. - Elastic straps 100 cm [9] (F7) [9]
is extremely easy and intuitive to 1 pc. - Black splitting cables [10] (C/DU-N) [12] [1]
operate. 1 pc. - Red splitting cables [11] (C/DU-R) [10] [13]
[15] [14]
[20]

1 pc. - Power cable [12] (C/A)


(*)
See page 4 for additional information.