Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference
ECMset
ECM (Brushless motor) Current Switch
Adjustable minimum turn-on
Prevents false trip due to ECM stand-by current
Split-core operation to 200A
N.O. 30VAC/DC output
Optional command relay with LED
DESCRIPTION APPLICATIONS
ECMSet™ is designed for no/go run detection on electronically commutated
motors (ECMs) . ECMs draw a small amount of AC standby current to power their • No/go run detection for EC motors
inverter, up to 1A, even when the motor isn’t running. The ECMSet features a • On set-point prevents false trips due to EC
high resolution adjustable turn-on setpoint to ignore standby current, preventing inverter stand-by current
false ON status indications. • Great for data center current switch sensing
Turn-on setpoint minimizes false trips due to Optional CR command relay for
standby ECM inverter draw. stop/start/status in a single labor saving
device.
FEATURES
• Reliable operation on ECM motors • No hazardous guesswork. Multi-turn adjustments are a thing of
• Set trip point with easily scaled dial to that sensor only turns on the past
when motor is actually running • Reduce the risk of arc flash; sensor can be set without
• Super low turn-on adjustment scale Maintenance-free—no call calibration in live enclosure
backs • Industry leading 7 year warranty
866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 1
Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference
ORDERING
866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 2
Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference
DIMENSIONS
Warning: The datasheet is designed for reference only. Refer to installation instructions that accompany the product and heed all safety
instructions. Product improvement is a continuing process at Senva. Changes may occur to products without prior notice.
866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 3
Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference
SPECIFICATIONS
Standard Output Rating 1.0A@30VAC/DC
Output Type NO, solid-state FET
Environmental Rating 5-140 °F (-15-60 °C)
10-90% RH Non-condensing
Insulation Class 600V RMS. For use on insulated conductors only! Use minimum
75 ° C insulated conductor
Sensor Power Induced
Frequency Range 50/60Hz
Dimensions (LxWxH) 2.94"x 2.23" x 0.82" (1.4"H with optional relay module)
Sensor Aperture 0.75"
Compliance cUL, UL, CE, RoHS
* Product improvement is a continual process at Senva and product features and specification may change without prior notice. Refer to instructions that accompany
the product for installation and wiring.
866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 4