0% found this document useful (0 votes)
39 views4 pages

Ecm (Brushless Motor) Current Switch: Ecmset

Uploaded by

arati sankhe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views4 pages

Ecm (Brushless Motor) Current Switch: Ecmset

Uploaded by

arati sankhe
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference

ECMset
ECM (Brushless motor) Current Switch
Adjustable minimum turn-on
Prevents false trip due to ECM stand-by current
Split-core operation to 200A
N.O. 30VAC/DC output
Optional command relay with LED

DESCRIPTION APPLICATIONS
ECMSet™ is designed for no/go run detection on electronically commutated
motors (ECMs) . ECMs draw a small amount of AC standby current to power their • No/go run detection for EC motors
inverter, up to 1A, even when the motor isn’t running. The ECMSet features a • On set-point prevents false trips due to EC
high resolution adjustable turn-on setpoint to ignore standby current, preventing inverter stand-by current
false ON status indications. • Great for data center current switch sensing

Turn-on setpoint minimizes false trips due to Optional CR command relay for
standby ECM inverter draw. stop/start/status in a single labor saving
device.
FEATURES

• Reliable operation on ECM motors • No hazardous guesswork. Multi-turn adjustments are a thing of
• Set trip point with easily scaled dial to that sensor only turns on the past
when motor is actually running • Reduce the risk of arc flash; sensor can be set without
• Super low turn-on adjustment scale Maintenance-free—no call calibration in live enclosure
backs • Industry leading 7 year warranty

866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 1


Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference

ORDERING

866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 2


Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference

DIMENSIONS

Warning: The datasheet is designed for reference only. Refer to installation instructions that accompany the product and heed all safety
instructions. Product improvement is a continuing process at Senva. Changes may occur to products without prior notice.

866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 3


Higher Reliability, Faster Installation, Superior Accuracy | Sense the Difference

SPECIFICATIONS
Standard Output Rating 1.0A@30VAC/DC
Output Type NO, solid-state FET
Environmental Rating 5-140 °F (-15-60 °C)
10-90% RH Non-condensing
Insulation Class 600V RMS. For use on insulated conductors only! Use minimum
75 ° C insulated conductor
Sensor Power Induced
Frequency Range 50/60Hz
Dimensions (LxWxH) 2.94"x 2.23" x 0.82" (1.4"H with optional relay module)
Sensor Aperture 0.75"
Compliance cUL, UL, CE, RoHS

* Product improvement is a continual process at Senva and product features and specification may change without prior notice. Refer to instructions that accompany
the product for installation and wiring.

866-660-8864 | fax 503-296-2529 | www.senvainc.com V2 7/2/24 4