File Number:JAGZ03-02

Issue Date:2013-09-01

User Manual of Portable


Oxygen Concentrator

MODEL:JAY-1

Important: Do not service this concentrator without first


reading and understanding this manual!
CONTENTS

1 Foreword…………………………………………………………3
2 Safety notice……………………………………………………4
3 Product introduction…………………………………………… 7
4 Using condition………………………………………………… 7
5 Scope of application……………………………………………8
6 Technical parameter……………………………………………8
7 N a m e a nd f u nc ti o n …… … … … … … … … … … … … … … … 9
8 Operation steps………………………………………………1 0
9 Maintenance……………………………………………………1 2
10 Troubles and solution…………………………………………13
11 Condition for transportation and storage……………………14
12 Quality warranty………………………………………………14
13 Contact us……………………………………………………14

2
1 Foreword

Thank you for purchasing our products, hoping you will be satisfied with
our products.
This operation manual contains function, operation steps, attention, basic
trouble solution and so on.
To ensure your efficient use of the machine, please have a close read of
this operation manual before operating it.
Maybe, there are some pictures, which are different from what you have
seen in the real model in this manual.

YOU MUST DO BEFORE START THE MACHINE!

White tie Cut and pull out

3
2 Safety notice
This product cannot be used for life saving, it is suggested that if any patient who needs
oxygen treatment, please follow doctor’s advice to choose the right flow and period for oxygen
before using the machine.
Please note the following special statements, used throughout this manual, and their
significance:
Note: Explanatory information.

Damage: Action could result in damage to equipment.

ATTENTION: Action could result in personal injury.

WARNING: Action could result in fire and explosion.


ATTENTION: Consult Instructions For Use.

: The date of Manufacturer

: The Manufacturer
Before Installation

Damage: Only use stable and safe electrical power sources.

Damage: If the electrical power source becomes unstable, discontinue use.


Placement

ATTENTION: The oxygen concentrator should be set to use in an environment without


dust, corruption or toxicological harm gas.

ATTENTION: The oxygen concentrator should be located in well-ventilated space, in case


there are polluted air or smog in the oxygen.

ATTENTION: Always place the concentrator on a hard surface. Never place the
concentrator on a surface such as bed or couch, where the concentrator may tip or fall.
Fire Warning

WARNING: For oxygen can be combustion-supporting, keep oxygen concentrator far


away from naked light or fire resource, no smoking or naked light around the patient.

WARNING: Keep the concentrator away from flammable and explosive areas.

4
WARNING: Textiles and other materials that normally would not easily burn, can ignite
and burn with great intensity in oxygen enriched air.

WARNING:A spontaneous and violent ignition may occur if oil, grease or greasy
substances come in contact with oxygen under pressure. ALWAYS keep these substances
away from the oxygen concentrator.
Maintenance

ATTENTION: Before cleaning the dust on the net of oxygen concentrator, the plug must
be pulled out in case electric attack.

ATTENTION: The humidifier, filter cotton and filter are the items needed to clean, among
which humidifier should be cleaned every 3 days, and external filter cotton should be cleaned
every 100 hours, and internal filter should be cleaned every 3000 hours.
Radio Frequency Interference
Most electronic equipment is influenced by Radio Frequency Interference (RFI). When there is
strong electromagnetic interference, maybe the LCD will be slightly affected, but the machine
is still running. ALWAYS exercise CAUTION with regard to the use of portable communications
equipment in the area around such equipment.
Additional Safety Warnings

WARNING: Do not put nasal tube under bed or cushion, the oxygen that caused by
machine turning on without breathing may be combustion-supporting.

WARNING:DO not reach for a concentrator that has fallen into water. UNPLUG IT
IMMEDIATELY.

WARNING:NEVER leave the concentrator unattended when plugged in.

ATTENTION:ALWAYS supervise closely when this product is used near children or those
who require close supervision.

ATTENTION: If any adverse reaction appeared or revealed during taking oxygen , please
contact with equipment supplier or doctor as soon as possible.

ATTENTION: For serious patients, set an indicating device additional, any adverse
reaction appeared, please contact with equipment supplier or doctor as soon as possible.

ATTENTION: Turn off the switch if no body takes oxygen.

5
ATTENTION: In using the machine, do not open the cover at all. In case there are quality
problem, do not dismantle it secretly. Any alarm or other abnormal phenomenon has been
found, connect with equipment supplier or factor.

ATTENTION: Ensure the bottom smooth exhaustion during operating, or else the machine
will be over-heated.

ATTENTION: There is intermitted exhaustion sound during operating (10 seconds in


intermission).

ATTENTION: 5 minutes are needed from oxygen concentrator from warming up to reach
regular function.

ATTENTION: The machine is only for medical oxygen supply, and the oxygen
concentration will be up to 90% when air outlet reaches its nominal flow.

ATTENTION: Humidifier shall adopt distilled water or cold boiled water, added water shall
be kept under the scale line.

ATTENTION: Use the humidifier together with the machine, do not replace it at will, or
else it may cause patient uncomfortable or other harms.

ATTENTION: In case the indicator shows abnormal oxygen, operator should declare to
dealer or factory in favor of maintain.

ATTENTION: Once open the adjust knob for flow in full, but flow meter shows zero, turn
off the machine immediately and have a check for trouble.

ATTENTION: Do not turn on or off frequently, To restart the machine after turning off, no
less than 5 minutes are necessary (namely, exhaust internal gas of the machine completely,
for if air compressor turns on with pressure, its life will be shortened )

ATTENTION: Turn up the flowmeter switch immediately when power switch is turned on.

ATTENTION: Refresh the water in the dampen bottle every 2-3 days, especially in
summers. If do not use it in several days, please pour out the water completely, and wipe dry
the bottle.

ATTENTION: Use the oxygen tube and humidifier together with the machine or those of
the same model, if change to use other model devices, please ensure close connection with
the oxygen generator. The absorbing oxygen tube is only for the patient, and do not junk it at

6
will.

ATTENTION: The oxygen tube, oxygen mask that have touched with the patient should
keep clean, disinfected and sterilized.

ATTENTION: The oxygen tube that have touched with the patient after each operation
should be disinfected by wiping it with 75% medical use alcohol or other disinfecting methods.
To prevent cross infection, do not share oxygen tube.
Requirement of environment protection
The materials used in the system won’t create environment hazard. The packing materials of
the system are recyclable, and they must be collected and disposed according to the related
regulation in the country or region where the package of the system or its accessories is
opened. The nasal oxygen tube is made of medical PVC, and if it is thrown away, it could not
be bio-degradable,so it will cause the pollution.Any material of the system, that may cause
pollution in the environment, must be collected disposed strictly complied with the local rules
and requirement

3 Product introduction
JAY-1 product adopt pressure swing adsorption principle, which can separate oxygen,
nitrogen and other gas from the air, at constant temperature, as soon as power is connected,
the oxygen that meets medical use standards can be separated from air constantly. Oxygen is
generated by pure physical method. The concentrator can supply ONE patient with steady
oxygen flowing out, safe and reliable, low cost, adjustable flow. The key parts of the
concentrator adopt anti-tiring and anti-aging design, and the planned life of the whole
generator reaches up to 20,000 hours.
There is no influence on indoor oxygen percent during the generator operating.

4 Using condition
Ambient temperature: 10℃-40℃
Relative humidity: 30%-85%
Air pressure: 700 hPa-1060 hPa
No corrosive gas and strong magnetic field around.

5 Scope of application
This device is mainly used for health care.

7
6 Technical Parameter
Model description: JAY-1
J (company symbol )
A (company symbol)
Y (oxygen)
1(1 liter per minute of oxygen )
Model JAY-1
Rated power (W) 75
AC220±10% 50±1
Operation voltage (V/Hz)
AC110±10% 60±1
Oxygen flow (L/Min) 1-5
Oxygen concentration (%) 90%-38%
Outlet pressure ( Mpa ) 0.041
Alarm Power failure
Sound level (dB) ≤45
LCD display accumulating timing; present timing; timing;
Net Weight (Kg) 6
Dimension (mm) 350(deep)*190(width)*320(height)

Fuse F2A/250V

Vehicle Power Input: DC 12V Output:AC220V/200W

8
7 Name and Function


2 ○
2


1 ○
7 ○
1 ○
7


8 ○
4 ○
8


9 ○
3 ○
9 ○
5


10


6


11

1)Indicating Lamp
Total 6 indicating lights, and the code of them are 1,2,3,....6 from left to right, and their
indication for each model are as follows:
O.P.: power switch (green lamp)
P.F.: power failure(red lamp)
L.P.: low pressure(yellow lamp)
H.P.: high pressure(red lamp)
H.T.: over heated temperature(red lamp)
L.O2.:oxygen purity is < 82%,(red lamp)
H.O2.:oxygen purity is  82%, (blue lamp)
2) Power switch

9
3) Oxygen flow meter
The location of float in the oxygen flow meter shows the outlet oxygen flow (L/min.).
4) Knob of oxygen flow meter switch
The other name of knob of oxygen flow meter switch is flow control valve.
It adjusts and controls the outlet oxygen flow.Do not rotate it over-forced, or else it is easy to
damage the valve core. Rotate it counterclockwise to turn on, clockwise to turn off.
5) The flow regulation button
At the digital flow control model, the flow will be 1L/Min when the oxygen concentrator begins
to run every time.Press (▲) to increase your favorite supplying flow by adding 1L/Min.Press
the(▼)button to decrease the flow by reducing 1L/Min.The max is 5L/Min.When user select the
flow, the screen will also show the purity accordingly.
6) Intake air filter
Once need to replace, replace it by special filter for the machine
7) LCD display

When the oxygen concentrator begin to run, and In one minute,


the LCD shows the accumulating timing.

After one minute, the LCD shows the present timing


automatically.

At the digital flow control model,when the user press the oxygen
flow meter key of “UP” or “DOWN”, the LCD will show the flow rate and purity.”1L” means the
flow rate,”90” means the oxygen purity.
8)Timing keys
The two buttons are used for timing adjustment, and press the left key(▲) on to increase timing
by adding 10min. And press the right key (▼) on to decrease timing by reducing 10min. the
right key (▼) to reduce timing to “0”, the machine will turn off automatically. The max timing

10
time is 40 hours.
9) Humidifier
Humidifier which used for humidifying oxygen and preventing throat and nasal mucosa
stimulated by dry oxygen and dry hard sputum difficult to spit out.
10) Back label
11) Power socket

8 Operation steps
1. Take down the Humidifier cup from the machine, take the top small white rubber cap out of
the cup, fill the Purify or boiled water into the cup till the lane marked on the cup, put back the
rubber cap.

White rubber cap

2. Connect the harness to both Oxygen concentrator & home power supply plug, Press the
switch to start the machine.
3. Adjust well oxygen output flow according to the request:
Method 1: Adjust the flowmeter knob, the float ball center position aligned with the
scale(counter-clockwise on and clockwise off)

Method 2: Press "△ UP" or "▽ DOWN" buttons, the LCD screen will display the adjusted

11
flowrate, machine is turned on by default flow rate of 1 L/ min.

4. Insert the intake end of absorbing oxygen tube onto the oxygen outlet, then set the
absorbing oxygen tube over patient’s ears, insert the nasal tube into patient’s nostrils to absorb
oxygen; the best absorbing time for health care keeps 40-50 minutes per time, absorbing time
for medical treatment shall be followed doctor’s advice.

5. Once the oxygen therapy finished, press the switch to shut down the machine,please also
un-plug the power supply at the same time.
6. Oxygen purity alarm(for optional): The oxygen purity will rise to the normal level in five
minutes of operation. When oxygen purity is  82%, the blue lamp is on, when oxygen purity
is <82%, red lamp is on, indicating low purity.
7. In case oxygen generator is connect with power but the whole machine is still in the state of
power off with alarm sound, please check out the connection part of power whether it is in good
connection, or whether there is a power off in external power supply.

9 Maintenance
1.In the condition of power off, make a clean for the outside body by soft towel with little
detergent, and then wipe it up with dry towel, once or twice per month.
2. It is a critical step for daily maintenance to clean filter net for gas intake, at least twice a

12
month.
Detail steps: take off the filter net, clean them with detergent and wash it clearly with clean
water completely, get ride of extra water and dry up naturally, finally set back after dry up.

Air intake window


3. Clean secondary filter
Clean secondary filter an interval about 3000 hours, open the air intake window, then open the
secondary filter cover in an anticlockwise direction and take off filter cloth, then clean it with
detergent, and then clean it out with clean water completely, get rid of the extra water, and dry
it naturally, finally set back after dry up.

Secondary filter

4. Fuse replacement
The fuse is located nn the internal control PCB, please contact the professional service people
to change this fuse.

13
FUSE
5. The battery of JAY Series medical oxygen concentrator model adopt NI-MH charge
battery(3.6V/20mAh),it is welded on the main board and there is a charge circuitry in the board,
so it could be used by a long time. But if you could not use the oxygen concentrator continually,
the battery will be at the dormancy state and its life will be shorter. So please charge the
battery one time every month if you could not use the oxygen concentrator continually.

10 Troubles and solution


No. Trouble Causes Solution
1 No operation after 1. No connection between 1. Check out whether switch,
power connected circuit of oxygen generator and plug, power line in good
power connection.
2. Circuit of fuse protector 2. Replace the fuse protector
broken and find the cause
3. Capacitor of compressor 3. Replace start capacitor
broken 4. Have the compressor
4. Compressor broken replaced
2 No oxygen out or 1. Folded inside oxygen tube, 1. Connect the oxygen tube
tiny outtake flow no smooth outtake again
2. Filter clogged, no smooth 2. Clean the filter
intake 3.Open the cover and check the
3. Some pipes are leakage. gas pipes.
3 No exhaust sound 1. Air controller cannot work 1.Have air control valve replaced
2. Electrical control board 2.Have electric control board

14
cannot work replaced
4 Too noisy 1. The joint of exhaustion 1. Connect the joint well
exhaustion muffler fallen off 2.Have the muffler replaced
2. Exhaustion muffler broken

11 Condition for transportation and storage


Environment temperature scale: -20-45℃
Comparative humidity scale: ≤95%
Air pressure scale: 500—1060 hpa

12 Quality Warrant
Scale for the whole machine repair: 15 months guarantee from the date two months after
sailing.

Note: Please do place the machine at a good ventilation area, please make
sure that the radiation port underneath the machine will not be covered.

13 Contact us
LONGFIAN SCITECH CO.,LTD

ADDRESS:Longxing Building A(413) No.77 Longxing Road,Baoding,P.R.China

TELEPHONE:+86-312-3169262

FAX:+86-312-3169301

HOMEPAGE:www.longfian.com

15

You might also like