Single-stage safety

solenoid valves

MVD, MVD/5,
MVDLE/5

6.20

Technical description Application


The DUNGS safety solenoid valve MVD, The solenoid valve is used for securing, limit-
MVD/5, MVDLE/5 is a single-stage auto- ing, shutting off and releasing gas supply to
matic shut-off valve as per EN 161 for gas gas burners and gas appliances.
burners and gas appliance.
- Max. operating pressure up to 200, 360 The DUNGS safety solenoid valve MV...
or 500 mbar (20, 36 or 50 kPa) is suitable for gases of families 1, 2, 3 and
- normally closed other neutral gaseous media.
- MVD: fast opening
- MVDLE: Slow opening with adjustable Approval
Printed in Germany • Edition 2022.08 • Nr. 214 756

fast stroke for start gas volume EU type testing certificate as per:
- Main volume adjustable (MVD/MVDLE) • EU-Gas Appliances Regulation
- DC solenoid, rectifier wiring with radio • EU-Pressure Equipment Directive
interference suppression in terminal box Approvals in other important gas consum-
with PG screw union ing countries.
- Mountable closed position signal contact Special designs for the North American
to monitor closed position of valve (.../5) market with UL, FM and CSA registrations.
- Pipe thread as per ISO 7/1
- Flange connection as per DIN EN 1092-1
- Reliable function, rugged and mainte-
nance-free
- On request, design without non-ferrous
1…6 metals
MV/5 Single-stage solenoid valve, normally when closed, fast opening, fast closing.

MVD/5 Single-stage solenoid valve, normally when closed, fast opening, fast closing, manual limitation of
flowing gas volume by adjusting main volume.

MVDLE/5 One-stage solenoid valve, normally when closed, slow opening, fast closing. Opening time adjust-
ment with fast stroke range. Main volume adjustment.

Specifications

Nominal diameters 10 15 20 25 40 50 65 80 100 125 150


Pipe thread as per ISO 7/1, Rp 3/8 1/2 3/4 1 1 1/2 2 2 1/2
Flange Connection flange (PN 16) as per DIN EN 1092-1

Max. operating pressure up to 200 mbar (20 kPa), 360 mbar (36 kPa) or up to 500 mbar (50 kPa) - refer
to type overview

Solenoid valve Valve as per EN 161, Class A, Group 2, single-stage mode

Closing time <1s

Opening time < 1 s for MVDLE approx. 20 s at room temperature 20 °C and without fast stroke

Fast stroke Adjustable

Main volume adjustment Manually adjustable on MVD and MVDLE

Materials of gas-conveying parts Housing: aluminium, steel, brass


Seals: NBR basis

Voltage/frequency 230 V AC (+10 % -15 %); 50-60 Hz - other voltages on request


Solenoids 60E, 61E in 24-28 VDC
external activation of solenoid coils required, see operating and mounting instructions

Rating / power consumption Refer to type overview

Switch-on duration 100 %

Degree of protection IP 54, IP 65 on request

Electrical connection At screw terminals via PG* 11 cable gland (* = heavy-gauge conduit thread)
Plug connection as per DIN 175 0301-803 can be retrofitted

Switching rate MVD…/5: max. 1000/h


MVDLE…/5: max. 100/h
MVD 2125/5, MVD 2150/5, MVD 5100/5, MVD 5125/5, MVD 5150/5: max. 20/h
MV 5125/5 S, MV 5150/5 S: max. 20/h

Measuring/ignition gas connection G 1/4 ISO 118, on both sides in inlet section,
additionally G 3/4 on input side, form size DN 40 (flange) upwards

Dirt trap Sieve installed, mesh width 1 mm

Ambient temperature -15 °C to +60 °C

Installation position Solenoid from vertically upright to horizontally lying

Closed position signal contact MV/5, MVD/5, MVDLE/5: Type K01/1, DIN-tested, mountable on DN 10 - DN 150

Valve proving system Type VDK 200 A S02, mountable via G 1/4 test connection, Type VPS 504,
mountable with adapter up to DN 80

Accessories K01 closed position signal contact, see Datasheet 12.01 211 202
Equipment plug for line socket, DIN 175301-803 215 733
2…6
Type pmax. DN / Rp Sole- Order No. Order No. Pmax. Imax. Ope- Dimensions [mm] Order
noid with PG11 with line [VA] ~ (AC) ning No.
No. socket 230 V time ø a b c d e f [kg]
MVD 203/5 360 Rp 3/8 100 108 571 15 0,08 <1s 50 60 90 60 113 140 0,85
MVD 205/5 360 Rp 1/2 100 013 102 270 486 15 0,08 <1s 50 80 90 75 113 150 1
MVD 207/5 360 Rp 3/4 200 121 962 270 487 25 0,15 <1s 75 100 135 85 160 200 2,4
MVD 210/5 360 Rp 1 200 013 490 270 488 25 0,15 <1s 75 110 135 90 165 200 2,45
MVD 215/5 200 Rp 1 1/2 280 015 446 270 489 60 0,26 <1s 80 150 170 116 215 255 4,3
MVD 215/5 360 Rp 1 1/2 300 121 977 60 0,3 <1s 95 150 170 116 215 260 5,4
MVD 220/5 200 Rp 2 300 011 767 270 490 60 0,3 <1s 95 170 170 116 215 260 5,9
MVD 225/5 200 Rp 2 1/2 400 119 701 100 0,48 <1s 115 230 220 165 215 325 10,9
MVD 503/5 500 Rp 3/8 100 158 090 15 0,08 <1s 50 60 90 60 113 140 0,85
MVD 505/5 500 Rp 1/2 100 158 110 270 491 15 0,08 <1s 50 80 90 75 113 150 1
MVD 507/5 500 Rp 3/4 200 157 530 270 492 25 0,15 <1s 75 100 135 85 160 200 2,4
MVD 510/5 500 Rp 1 200 157 540 270 493 25 0,15 <1s 75 110 135 90 165 200 2,45
MVD 515/5 500 Rp 1 1/2 300 157 550 270 496 60 0,3 <1s 95 150 170 116 215 260 5,4
MVD 520/5 500 Rp 2 400 167 200 270 498 100 0,48 <1s 115 170 190 130 235 300 8,8
MVD 525/5 500 Rp 2 1/2 500 170 750 80 0,42 <1s 130 230 215 165 300 370 14,5
MVDLE 203/5 360 Rp 3/8 100 108 597 15 0,08 ca. 20 s 50 60 135 75 155 190 0,95
MVDLE 205/5 360 Rp 1/2 100 013 284 271 211 15 0,08 ca. 20 s 50 80 135 75 155 200 1,1
MVDLE 207/5 360 Rp 3/4 200 013 276 271 212 25 0,15 ca. 20 s 75 100 165 85 190 190 2,55
MVDLE 210/5 360 Rp 1 200 013 524 271 213 25 0,15 ca. 20 s 75 110 165 90 200 190 2,75
MVDLE 215/5 200 Rp 1 1/2 280 015 412 270 502 60 0,26 ca. 20 s 80 150 205 116 245 255 4,4
MVDLE 215/5 360 Rp 1 1/2 300 122 002 60 0,3 ca. 20 s 95 150 205 116 245 255 5,5
MVDLE 220/5 200 Rp 2 300 011 775 270 503 60 0,3 ca. 20 s 95 170 205 130 250 255 6,2
MVDLE 225/5 200 Rp 2 1/2 400 118 935 100 0,48 ca. 20 s 115 230 295 165 350 320 11,4
MVDLE 503/5 500 Rp 3/8 100 222 077 15 0,08 ca. 20 s 50 60 135 75 155 190 0,8
MVDLE 507/5 500 Rp 3/4 200 222 079 271 193 25 0,15 ca. 20 s 75 100 165 85 190 190 2,5
MVDLE 515/5 500 Rp 1 1/2 300 222 081 271 195 60 0,3 ca. 20 s 95 150 205 116 245 255 5,6
MVDLE 520/5 500 Rp 2 400 222 082 271 196 100 0,48 ca. 20 s 115 170 230 135 270 300 11,1
MVD 2040/5 200 DN 40 280 111 146 60 0,26 <1s 80 200 170 150 235 255 6,8
MVD 2040/5 360 DN 40 300 111 906 60 0,3 <1s 95 200 170 150 235 255 7
MVD 2050/5 200 DN 50 300 111 187 60 0,3 <1s 95 230 171 165 245 255 7,7
MVD 2065/5 200 DN 65 400 169 390 100 0,48 <1s 115 290 221 185 315 330 12,7
MVD 2080/5 200 DN 80 500 169 400 80 0,42 <1s 130 310 250 200 340 375 18,5
MVD 2100/5 200 DN 100 550 169 410 100 0,48 <1s 150 350 310 240 410 480 31
MVD 5040/5 500 DN 40 300 170 660 60 0,3 <1s 95 200 170 150 255 255 7
MVD 5050/5 500 DN 50 400 170 690 100 0,48 <1s 115 230 190 165 295 295 12
MVD 5065/5 500 DN 65 500 165 510 80 0,42 <1s 130 290 245 190 370 370 17
MVD 5080/5 500 DN 80 550 165 640 100 0,5 <1s 150 310 295 200 465 465 27
MVDLE 2040/5 200 DN 40 280 111 914 60 0,26 ca. 20 s 80 200 205 150 270 255 6,9
MVDLE 2040/5 360 DN 40 300 111 153 60 0,3 ca. 20 s 95 200 205 150 270 255 7,1
MVDLE 2050/5 200 DN 50 300 111 195 60 0,3 ca. 20 s 95 230 210 165 280 255 7,5
MVDLE 2065/5 200 DN 65 400 170 930 100 0,48 ca. 20 s 115 290 290 190 385 330 13,3
MVDLE 2080/5 200 DN 80 500 170 940 80 0,42 ca. 20 s 130 310 320 200 405 375 18,5
MVDLE 2100/5 200 DN 100 550 170 950 100 0,48 ca. 20 s 150 350 380 240 480 480 31
MVDLE 5040/5 500 DN 40 300 222 086 60 0,3 ca. 20 s 95 230 205 150 255 255 7
MVDLE 5050/5 500 DN 50 400 222 087 100 0,48 ca. 20 s 115 230 230 165 295 295 13,1
f = Space requirement for solenoid changing
d = largest width

3…6
Dimensions [mm]
MVD 203-525/5,
MVDLE 2020/5-2100/5

d = largest width
Ignition gas valve, Type MV 502, refer to Datasheet 6.01
* Mounting of a closed position signal contact not possible

Dimensions [mm]
MV 5100/5 - MVD 5150
MV 2125-MV 2150
MV 5125 S
MV 5150 S

Type pmax. DN / Rp Order Sole- Pmax. Imax. Opening Dimensions [mm] Weight
No. noid [VA]* ~(AC) time [kg]
No. 230 V a b c d e f g h
[A] **

MV 5125/5 S 500 DN 125 224 681 60S 90 7.5 <1s 170 400 406 290 531 514 112 125 56.0
MV 5150/5 S 500 DN 150 224 682 61S 90 10 <1s 170 480 439 290 582 547 125 143 62.0

MVD 5100/5 500 DN 100 166 150 60E 1) 90 7.5 <1s 170 350 365 290 465 498 80 100 39.0
MVD 2125/5 200 DN 125 159 830 60E 1) 90 7.5 <1s 170 400 406 290 531 514 112 125 56.0
MVD 5125/5 500 DN 125 159 840 60E 1) 90 7.5 <1s 170 400 406 290 531 514 112 125 56.0
MVD 2150/5 200 DN 150 160 050 61E 1) 90 10 <1s 170 480 439 290 582 547 125 143 62.0
MVD 5150/5 500 DN 150 160 350 61E 1) 90 10 <1s 170 480 439 582 547 125 143 62.0
* Electrical rating in open state 1)
Solenoids 60E, 61E in 24-28 VDC
** Switch-on current for approx. 3 s external activation of solenoid coils required, see operating and mounting instructions

4…6
Type MVD…/5 Type MVDLE/5

9
10

8
7
8 7

6
5
4
3
2
1

p1 p2
p1 p2

1 Housing 5 Armature Setting


2 Sieve 6 Solenoid coil 8 - Main volume
3 Valve plate 7 Electrical connection 9 - Fast stroke
4 Closing spring 10 - Hydraulic brake

Functional description
The DUNGS safety solenoid valve is The stroke of armature 5 can be limited If the auxiliary power is interrupted
an automatic shut-off valve operated by the setting screw 8. (operating voltage), closing spring 4
with auxiliary power. The hydraulic brake 10 permits slow closes the valve within 1 second.
The electromagnetic drive opens opening. Fast stroke 9 can be ad- The closed position of the valve can
against the force of the closing spring 4. justed. be monitored by a mountable closed
position signal contact.

Gasart Dichte
°
V = °
V x f
verwendetes Gas/gas used/ gaz utilisé/gas utilizzato Luft/air/air/aria Type of gas Spec. Wgt.
Type de gaz poids spécifique dv f
Tipo di gas Peso specifico
[kg/m3]

Erdgas/Nat.Gas/ 0.81 0.65 1.24


Dichte Luft Gaz naturel/Gas metano
Spec. weight air
poids spécifique de l´air Stadtgas/City gas/ 0.58 0.47 1.46
peso specifico aria Gaz de ville/Gas città
f=
Dichte des verwendeten Gases Flüssiggas/LPG/ 2.08 1.67 0.77
Spec. weight of gas used Gaz liquide/Gas liquido
poids spécifique du gaz utilisé
peso specifico del gas utilizzato Luft/Air/ 1.24 1.00 1.00
Air/Aria
5…6
Single-stage safety
solenoid valves
MVD, MVD/5,
MVDLE/5

Flow diagram

We reserve the right to make any changes in the interest of technical progress.
Head Offices and Factory Postal address
Karl-Dungs-Platz 1 Karl Dungs GmbH & Co. KG
D-73660 Urbach, Germany Postfach 12 29
Telephone +49 7181-804-0 D-73602 Schorndorf, Germany
Fax +49 7181-804-166 e-mail [email protected]
Internet www.dungs.com 6…6