UPDA (96 Page PDF) - Transformers-1
UPDA (96 Page PDF) - Transformers-1
In a transformer
2. Laminated insulations coated with varnish are normally used in the transformer
5. The following arrangement will reduce the reluctance of magnetic path of the transformer.
a. A
b. B
c. C
d. D
a. Size of winding
b. Size of tank
c. Current flowing
d. Voltage supplied
a. Decomposition of oil
b. Decomposition of insulation
c. Moisture content in oil
d. None of the above
10. A transformer used only for electrical isolation between two circuits has turns ratio which is
11. If 90 percent of normal voltage and 90 percent of normal frequency are applied to a transformer, the
percent change in hysteresis losses will be
a. 20%
b. 4.7%
c. 19%
d. 21%
a. Core loses
b. Ohmic losses
c. Hysteresis losses
d. Eddie current losses
13. If 110 percent of normal voltage and 110 percent of normal frequency is applied to a transformer, the
percentage change of eddy current losses will be
a. 10%
b. 20%
c. 25%
d. 21%
14. A transformer has two 2,400 V primary coils and two 240 V coils. By proper connection of the windings, the
transformation ratio that can be obtained is
a. 10
b. 5
c. 20
d. 9
15. A single-phase, 2,200/200 V transformer takes 1 A at the HT side or no load at a power factor of 0.385
lagging. The iron losses are
a. 167 W
b. 77 W
c. 88 W
d. 98 W
16. Neglecting resistance, at constant flux density, the power required per kilogram to magnetize the iron core
of a transformer is 0.8 W at 25 Hz and 2.04 W at 60 Hz. The power required per kilogram for 100 Hz is
a. 3.8 W
b. 3.63 W
c. 3.4 W
d. 5.2 W
a. rms value
b. Average value
c. Total value
d. Maximum value
a. 90° – 95°
b. About 80° – 85°
c. 0° – 15°
d. About 110°
20. High leakage impedance transformers are used for applications such as
a. Power distribution
b. Electrical toys
c. Arc welding
d. Fluorescent lamps
21. A transformer 2,000 kVA, 250 Hz is operated at 50 Hz. Its kVA rating should be revised to
a. 400 kVA
b. 10,000 kVA
c. 2,000 kVA
d. Cannot be revised
a. 100 kVA, 25 Hz
b. 100 kVA, 100 Hz
c. 100 kVA, 50 Hz
d. 100 kVA, 60 Hz
a. 50–60%
b. 65–75%
c. 70–90%
d. 90–98%
a. Hysteresis loss
b. Eddy current loss
c. Partly (a) and partly (b)
d. Increases exciting current
a. Power
b. Frequency
c. Voltage
d. Current
27. Transfer of electrical power from primary to secondary in a transformer takes place
a. Electrically
b. Electromagnetically
c. Magnetically
d. None of these
a. 0.35 cm
b. 0.35 mm
c. 0.33 m
d. 0.30 cm
29. A power transformer is a constant
a. Current device
b. Voltage device
c. Power device
d. Main flux device
a. rms
b. Average
c. Maximum
d. Integral wave cycle
a. Load current
b. Supply frequency
c. Mutual flux
d. None of these
32. The voltage regulation of a transformer at full-load 0.8 PF. lag is 6 percent. Its voltage regulation at full-load
0.8 power factor lead will be
a. Negative
b. 54%
c. Positive
d. Zero
33. The full-load efficiency of a transformer at 0.85 PF. lag is 97 percent. Its efficiency at full load 0.85 power
factor lead will be
a. 99%
b. 96%
c. 97%
d. 98%
34. If a load on secondary side of a transformer increases, the current on the primary side
a. Remains constant
b. Increases
c. Decreases
d. none of these
35. If a sinusoidal exciting current is applied to a transformer, the mutual flux produced is
a. Negative
b. Sinusoidal
c. Zero
d. Flat top
36. To get sinusoidal flux in a transformer the mutual flux produced is
a. Non-sinusoidal
b. Sinusoidal
c. Direct current
d. Zero
37. A 220V, 150V bulb is connected in series with the primary of a 220/1,100 V, 50 Hz transformer. If the load
on the secondary side is disconnected, the brightness of the bulb will
a. Decrease
b. Increase
c. Be unaffected
d. Decrease to a very low value
a. Load current
b. Supply frequency
c. Power factor of load
d. Both (a) and (b)
43. A ferrite core has less eddy current loss than an iron core because ferrites have
a. Lower permeability
b. High hysteresis
c. Alnico as the main constituent
d. High resistance
a. (a)
b. (b)
c. (c)
d. (d)
a. (a)
b. (b)
c. (c)
d. (d)
47. A transformer is connected to a constant voltage source. If the supply frequency decreases, the magnetic
flux in the core will
a. Inductive process
b. Convection process
c. Conduction process
d. All of these
a. Kept constant
b. Proportionally decreased
c. Proportionally increased
d. None of these
50. The efficiency of an autotransformer for the same output compared to a two-winding transformer is
a. Greater
b. Lesser
c. Poor
d. None of these
a. Correct polarity
b. Per unit impedance based on their rating should be equal
c. Identical voltage and frequency rating
d. Equal ratio of equivalent resistance to reactance
e. All of these
a. Open circuit
b. Dead short circuit
c. Regeneration of power
d. Power factor of transformer will be different from that of the connected load
a. A
b. B
c. C
d. D
54. A 10 kVA, 400/200 V single-phase transformer with 10 percent impedance draws a steady short circuit line
current of
a. 50 A
b. 150 A
c. 250 A
d. 350 A
a. 50 kVA
b. 15 kVA
c. 12.5 kVA
d. 8.75 kVA
56. An autotransformer having a transformation ratio of 0.8 supplies a load of 10 kW. The power transferred
inductively from the primary to the secondary is
a. 10 kW
b. 8 kW
c. 2 kW
d. Zero
57. A single-phase induction regulator is a constant input transformer to obtain smooth variation of the output
voltage by varying the
61. Transformer core usually uses grain-oriented laminated sheets. The grain orientation reduces
a. Copper loss
b. Eddy current loss
c. Hysteresis loss
d. None of the above
a. Series resistance
b. Series inductance
c. Shunt resistance
d. Shunt inductance
63. While performing short circuit test on a transformer, the impressed voltage magnitude is kept constant,
but the frequency is increased. The short circuit current will
a. Increase
b. Decrease
c. Remain the same
d. None of the above
64. A transformer has a hysteresis loss of 30 W at 240 V, 60 Hz. The hysteresis loss at 200 V, 50 Hz will be
a. 20.8 W
b. 25 W
c. 30 W
d. 36 W
65. In a transformer, the exciting current will be in phase quadrature with the impressed voltage provided
67. A transformer is to be tested at full-load conditions consuming only losses from the mains. We do
a. Load test
b. Open circuit and short circuit tests
c. Back-to-back test
d. None of these
68. In a transformer operating at constant voltage if the input frequency increases the core loss will
a. Increase
b. Decrease
c. Remain constant
d. Increase as the square of the frequency
a. Copper loss
b. Eddy current loss
c. Hysteresis loss
d. None of above
70. R1 is the resistance of the primary winding of a transformer. The turns ratio in terms of primary to secondary
is a, the equivalent resistance of the primary referred to as secondary is
a. R1/a
b. a2*R1
c. R1/a^2
d. None of these
71. Choose the correct statement:
a. emf per turn in high-voltage winding is more than the emf per turn in low-voltage winding
b. emf per turn in both the winding are equal
c. emf per turn in both the windings are not equal
d. None of these
72. If E2 be the induced emf in secondary winding and V2 be the terminal voltage during load, the regulation
of the transformer is given by
a. (A)
b. (B)
c. (C)
d. (D)
73. One transformer has leakage impedance of 1 + j 4 Ω and 3 + j 4 Ω for its primary and secondary windings,
respectively. The transformer has
74. A single-phase transformer has its maximum efficiency at 60 percent of full load. At full load copper loss
will be
75. The flux in a magnetic core is alternating sinusoidally at a frequency of 600 Hz. The maximum flux density
is 2 T and eddy current loss is 15 W. If the frequency is raised to 800 Hz and maximum flux density reduced
to 1.5 T, the eddy current loss will be
a. Same
b. Reduced to half
c. Doubled
d. Increased by 50%
a. Supply voltage
b. Supply voltage and frequency
c. Supply voltage, frequency and load
d. Supply voltage and load but independent of frequency
77. If the signal is power doubled at a given transmitter, what is the decibel (dB) increase?
a. 0.5 db
b. 2 db
c. 3 db
d. 4 db
78. HDL design is having inputs and outputs. Who should be giving the inputs and outputs in VHDL?
a. Architecture Declaration
b. Entity Declaration
c. Both Architecture and Entity
d. d. …..
a. 10 A
b. 15 A
c. 20 A
d. 30 A
80. Three resistors are connected in series l parallel combination what are the possibilities to get different total
resistance:
a. 3
b. 4
c. 5
d. 6
a. Waveguide
b. Antenna dish
c. …
d. …
82. Two test terminals: f short circuit 3 A, Connected to conductance of 0.2 S across 5 V (Check question)
83. Permanent magnet moving coil instrument (PMMC) type instruments normally use:
87. The total resistance of a circuit is 680 ohms, the percentage of the volt appearing across 47 ohm resistance
that makes as part of the total series resistance is:
a. 68 %
b. 47 %
c. 69 %
d. 6.9 %
a. Ceramic
b. Copper
c. Aluminum
d. Silver
a. Carbon
b. Aluminum
c. nickel
d. tungsten
91. certain communication channel has a signal to noise ratio of 7 and bandwidth of 10 KHZ what is the channel
capacity?
a. 30 bps
b. 80 bps
c. 3000 bps
d. 30,000 bps
92. An antenna has effective aperture of 10 m2 what is the additional information required to determine
delivered power?
a. Power density
b. Power losses
c. Space losses
d. Total torque
93. Radio station 50 KW power emitter and gain 1.5, at 10 KM what will be the output power density? (Check
question)
a. 75 mW/m2
b. 33 mW/m2
a. 20 km
b. 30 km
c. 40 km
d. 80 km
96. A digital signal processor (DSP) is design to perform FFT operations for a digital
oscilloscope that utilizes a 12-bit A/ D Converter. The most cost effective ALU
architecture for this CPU is a:
99. Talk about session hijacking and the methods hackers use to do hijack and how
to prevent the network from such attack?