E43e E3f2 - Z Photoelectric Sensor For Ac Power Supply, m18 Datasheet en
E43e E3f2 - Z Photoelectric Sensor For Ac Power Supply, m18 Datasheet en
E3F2-@Z
• 24 to 240 VAC power supply
• UL and CSA approved
Selection Guide
Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the length of the cable
(e.g. E3F2-R2Z1 2M or E3F2-R2Z1 5M). For other cable length please contact your OMRON sales representative.
* Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the length of the cable
(e.g. E3F2-R2Z1 2M or E3F2-R2Z1 5M). For other cable length please contact your OMRON sales representative.
E3F2-@Z 1
Specifications
Ratings / Characteristics of AC Switching Models
E3F2-3Z1 E3F2-R2Z1 E3F2-DS10Z1
Item
E3F2-3Z2 E3F2-R2Z2 E3F2-DS10Z2
Diffuse reflective
Sensing method Through-beam Non-polarizing Retroreflective (wide-beam characteristic)
Power supply voltage 24 to 240 VAC ±10 %, 50 / 60 Hz
Current consumption 10 mA max. 5 mA max.
*1 0.1 - 2 m 0.1 m
Rated sensing distance 3m
(with reflector E39-R1) (5 x 5 cm white mat paper)
E39-R1: 3,4 m
Typical sensing distance for dif-
– E39-R7: 3,9 m –
ferent reflector types *2
E39-R8: 5,2 m
Detectable object Opaque object: 11 mm min. Opaque object: 56 mm min. Opaque objects
Directional angle 3° to 20° –
Differential travel – 20 % max.
Response time 30 ms max.
Control output AC solid state (SCR) 200 mA max.; residual voltage: 5 V max. at 200 mA
Power reset time 100 ms
Ambient illumination Incandescent lamp: 3000 lx max. Sunlight: 10000 lx max.
Ambient temperature*3 Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation)
Ambient humidity Operating: 35% to 85% / Storage: 35% to 95% (without condensation)
Insulation resistance 20 M min. at 500 V DC between energized parts and case
Dielectric strength 1500 VAC, 50 / 60 Hz for 1 min between energized parts and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z)
Shock resistance 500 m/sqr (approx. 50 g) for each direction (X, Y, Z)
Enclosure rating IP67 *4; NEMA 1, 2, 4; IP69k after DIN 40050 part 9
Light source Infrared LED (880 nm)
Indicators Light incident/power indicator for light source (red)
Sensitivity adjustment Fixed
Connection method 2 m, 5 m pre-wired cable (PVC dia. 4 mm (14 / 0.15) *5)
Operation mode Light-ON or Dark-ON (fixed)
Circuit protection None
Weight (approx.) 110 g (pre-wired 2 m cable)
Housing materials Plastic (case: ABS; lens: PMMA)
*1
For stable sensing distance in detail, please refer to ”Engineering Data”
*2 Typical sensing distance corresponds to 80 % of the max. sensing distance.
*3
*4
The enclosure rating IP67 of OMRON internal standards correspond to stricter test requirements than the standard IEC 60529 (refer to chapter “Precautions”)
*5 For other cable materials (e.g. PUR) please contact your OMRON sales representative.
Distance Y (mm)
Distance Y (mm)
Distance Y (mm)
100 100
10
0 0 white paper
0
(50 x 50 mm)
–100 –100
–10
–200 –200
–20
Reflector Object
Y Y Y
X X X
–300 –300
–30
0 1 2 3 4 5 0 1 2 3 4 5 6 7 8
0 20 40 60 80 100 120 140
Distance X (m) Distance X (m) Distance X (mm)
Sensing object:
50 x 50 mm
10 10 10
Excess gain
Excess gain
Excess gain
White paper
reflector E39-R1 (90% reflectivity)
1 1 reflector E39-R7 1
Grey paper
(18% reflectivity)
reflector E39-R8
Operation
Output Connection
Model transistor status Timing chart method Output circuit
Through-beam emitter
Brown
Power
indicator
(red)
Blue
Incident
Interrupted
Output
E3F2-3Z1 ON when light is indicator
ON
OFF
E3F2-R2Z1 incident. (red) –
Output ON
E3F2-DS10Z1-N (Light-ON) transistor OFF Light
Brown
indicator
200 mA
Load Operate max. Load
Red
(relay) Release Black
Main
circuit 24 to 240 VAC
Blue
Incident
Interrupted
Output
E3F2-3Z2 ON when light is indicator
ON
OFF
E3F2-R2Z2 interrupted. (Dark- (red) –
ON) Output ON
E3F2-DS10Z2-N transistor OFF
Load Operate
(relay) Release
E3F2-@Z 3
Dimensions
Cable type
Without potentiometer
E3F2-3Z# 90
E3F2-R2Z#
67.3
E3F2-DS10Z#-N 62
8 5 dia.
M18 x 1 6g
24
3.1
Light indicator 16.8 dia.
22
Precautions
The E3F2 Photoelectric Sensor is not a safety component for ensur- When using the photoelectric sensor in the vicinity of an inverter
ing the safety of people which is defined in EC directive (91/368/ motor, ensure to connect the protective earth ground wire of the
EEC) and covered by separate European standards or by any other motor to earth. Failure to ground the motor may result in malfunction
regulations or standards. of the sensor.
Degree of protection When you use the photoelectric sensor at temperatures exceeding
45 °C, the load current must be within the described values as
The E3F2 photoelectric sensors have a degree of protection rated shown in the figure below.
with IP67. In this case, the sensors have passed the OMRON heat
shock test before the IP67-test of IEC 60529 (submersion at 1m
water depth for 30 min). Afterwards the sensors have been tested 200
according to the OMRON waterproof test.
Load current (mA)
Load
Blue
Cat. No. E43E-EN-01 In the interest of product improvement, specifications are subject to change without notice.
E3F2-@Z 4