(Summary) Control System Introduction
(Summary) Control System Introduction
Integrated
Individual control Centralized
Management BMS Gateway Others
system control system
system
Integrated
Individual control Centralized
Management BMS Gateway Others
system control system
system
BMS Gateway
· BMS gateway to enable a connection between Samsung
system air conditioner and BMS (Building Management System)
which controls all facilities and managements of an entire
building.
Others
· Additional devices used for other purposes to enhance
the control and management of Samsung system air conditioners.
· They can provide special solutions for users who have specific
requirements.
DMS Bnet DMS Lnet ※ Control layer : Controller can control multiple outdoor units and their indoor units.
Ethernet
Set layer : Controller can control one outdoor unit and its indoor unit.
F1/F2
F3/F4
R1/R2
CH1
Touch On/Off Wi-Fi kit
R1/R2 centralized controller
controller
Wi-Fi kit Local layer
F1/F2
R1/R2
ERV I/M ERV
CH2
F3/F4
F3/F4
F1/F2
F3/F4
3rd party FCU
PIM
CH4 R1/R2
Samsung FCU
R1/R2
FCU Kit F1/F2 OF1/OF2
FCU I/M (High level
(IDU) (ODU) controller)
AR-KH00E
- 360 cassette air flow direction control
- Simple schedule control(On timer / Off timer)
- On/off, operation mode, fan speed, Airflow, temperature setting
- Filter replacement alarm reset
- Zone selecting control (Max. 4 zones)
- Buzzer sound mute
- Address and option setting
12/100 This Document can not be used without Samsung's authorization
Wireless remote controller
■ Main function & feature
Zone selecting control
- You can select the indoor unit
- Use the Zone function to choose the indoor unit you want to operate individually
- This function prevents indoor unit mix-up. (Up to 4 channels can be set.)
1 2 1 1
MWR-WE11N
MWR-SH00N
MWR-SH10N
MWR-SH10N
- Touch screen
- Intuitive UI/UX
- Built-in room temperature sensor and IR receiver
- Outing operation
(81℉)
(72℉)
Stop
Set time
(0~12 hours)
360 CST
1way
In the office
“Turn it on now,
Cool home before I get there” 4way
“No need to look for
the remote controller”
Ducted
Ceiling
EHS
Easy settings
for 7 day weekly schedule
Shop manager
“Easy-to-use timer for cooling”
Shop manager
“One click to turn on all indoors of
desired zone at home”
Group 1
Enable to check Outdoor unit energy consumption pattern (daily, weekly and monthly)
outdoor unit is
Shop owner
“How much energy is used
compared with last month?
※ Caution
- Energy monitoring displays power output which is different from power consumption shown on electricity bills
- When it is connected to two or more outdoor units, some functions including energy monitor can be restricted.
- Energy monitoring can be used through the outdoor unit that support energy monitoring.
32/100 This Document can not be used without Samsung's authorization
Wi-Fi Kit
■ Main function & feature
Multi tenant function
- Controlling and monitoring of indoor units assigned to one group channel address(RMC1)
by identical tenant address of Wi-Fi kit.
Office
T/F room
Dining room
Office
Main conference
Conference
EX Emergency stop
R1/R2 Emergency
F1/F2 F1/F2
B zone
A zone
FCU
(Field supply)
Water Pump
(Field supply)
Manager
Administrator
ㆍUser can monitor the
Manager entire building’s units
ㆍUser can control the
Administrator entire on/off system
ㆍUser can monitor the
entire building’s units
ㆍUser can control the
entire on/off system
ㆍUser can monitor the
total power used
User
ㆍEach user can control
and monitor the allowed
unit only
Save history
DMS2.5
2 Data extract - Excel format
Operation Emergency
Error
Out
PIM DMS2.5
Supports
16 DMSs
▶ Class zone
137 kWh
3 Floor (office)
171 kWh
2 Floor (restaurant )
125 kWh
1 Floor (shop)
240 kWh
BMS SAC
Modbus Gateway
KNX Gateway
DMS BACnet Gateway DMS LonWorks Gateway Modbus Gateway KNX Gateway
BMS (BACnet)
Set Layer(F1/F2)
ODU
IDU IDU IDU IDU IDU Touch On/Off
centralized controller
controller
Set Layer(F1/F2)
ODU
IDU IDU IDU IDU IDU Touch On/Off
centralized controller
controller
Intesis gateway
※ One gateway can connect multiple outdoor units.
Control Layer(R1/R2)
Modbus / KNX
Gateway
ㆍOn/Off control
ㆍOperation indication
ㆍError Indication
ㆍFilter replacement sign
ㆍUse with receiver wire
(81℉)
(72℉)
3) Window Control
No
MTFC
OFF
Comm.
Case1 )
- Each tenant uses individual power breaker.
Even one tenant cuts power,
other tenants can use air-conditioner.
Case2 )
- Each card key tag is connected to power line.
Even a card key is removed,
other room can use air-conditioner.
FCU
(Field supply)
Water Pump
(Field supply)