Specification

Product name: Economic High Efficiency 3-LED Module

Product model: PWM7816-3YL2835-12V

formulate verify approve

UL CE RoHS LED
module
DC
12V
2835
SMD
IP
65 5
warranty

page 1 of 7
Part No.:
PWM7816-3YL2835-12V 78.4x15.5x7.6mm 3-LED SMD2835 175° Waterproof DC12V Constant Voltage
LED Module

Product picture:

Features:
1、 High light efficiency SMD2835 Chip, can reach 140Lm / W

2、 Large beam angle 175 degrees, uniform light;

3、 Using aluminum PCB board, good heat dissipation;

4、 Injection on the back of the module, the module thickness is thin and lightweight;

5、 CE & RoHS approved

Application:
Suitable for 5-15cm sign letter or airports, subways, banks, buildings, shopping malls and other advertising etc single side light box.

page 2 of 7
Parameters:

Input
Color Bean Luminous Lighting
CCT(K) Voltage Current
Item No. LED CRI Power
Wavelength tolerance Angle Flux effect
Color Ra (VDC (mA) (W/pcs)
(nm) SDCM (°) (lm) (lm/W)

3000
PWM7816- 4000
White ≥80 ≤5 175 200 135 12 120 1.44
3YL2835-12V 6500
10000

Other parameters:

Working Standard Max Cascade Max Cascade


Storage
Item No. IP cascade number from one number from two weight
temperature temperature
Rank number end of power end of power (g/pc)
(℃) (℃)
(pcs) supply (pcs) supply(pcs)
PWM7816-
IP65 -25~+60 -25~+70 20 20 40 10.3
3YL2835-12V

Remark:
(1)Test environment temperature is 25±2℃ (normal temperature);
(2)The above data is typical, the actual parameters of the product may differ from the typical data; the data is subject to change
without notice;
(3)The above "-" indicates that the parameters of this product are not required at the moment.

Dimensions:

page 3 of 7
Light distribution curve / isolux diagram:

Module Layout Density Guidelines:

Installation Watts per square


Light box thickness LED Spacing Surface illumination
density
(mm) (mm) (lux) (W/㎡)
(PCS/m²)

40mm Dx=110mm,Dy=65mm 140 7000-12000 207

50MM Dx=130mm,Dy=80mm 96 7000-8000 138

Dx=150mm,
60MM 66 5000-6500 96
Dy=100mm

Dx=160mm,
80MM 52 3500-5000 74
Dy=120mm

Dx=160mm,
100MM 44 2500-3500 64
Dy=140mm

Dx=160mm,
120MM 39 2000-3000 56
Dy=160mm

page 4 of 7
Installation:

Installation Steps:

◎ When the wire of the end module is


◎ Clean up debris on the mounting ◎ To Peel off the adhesive tape on exposed, first peel the wire for about 10mm,
surface to ensure surface cleaning. the back of the module, and lightly stick then screw the positive and negative wires into
to installation slot for initial positioning. the terminal separately and do waterproof and
insulation protection and treatment.

◎ When the modules are connected in


◎ After adjusting the module to the ◎ The positive and negative wire need
series, the positive and negative wires of
optimal installation position, squeeze the to be correctly connected to the positive
the modules are peeled separately for
double-sided adhesive and fix it with and negative terminals of the power
10mm and then connected with terminal,
neutral glass adhesive.
and do waterproof, insulation, anti - short supply output.
circuit and anti - corrosion treatment. ◎

page 5 of 7
Packaging:

Dimension of outer carton


Qty per roll Qty per Total qty Total Weight
Item No,. (mm)
(pcs) carton(bag) (PCS) (KG)
Length Width Height
PWM7816-
200 15 3000 32.1 520 300 280
3YL2835-12V

20 pcs per string Label stick on ESD bag


200pcs/bag

Sealing 3200pcs per carton

page 6 of 7
Common faults of products and troubleshooting methods:

Fault phenomenon Potential causes Solution

1. The power is off. Power transmission


2. Automatic protection of the power supply after
All LEDs are off the output of the switching power supply is open Trouble shooting and recovering the power supply
or shorted.
3. LED modules with power supply terminal Check the wire connection status to ensure that the
polarity reverse positive and negative connections are correct
1. Part of the switching power supply is not
powered Check the power supply system and troubleshoot
Some of the LEDs are
2. Part of the electricity supply line error
off
3. Partial led module with reverse polarity
Correct connection
connection
Replace the power supply with a larger power according
1. Power overload
to the load
Ensure that the operating voltage of the led strips is
within ±5% of the rated voltage
LED brightness is not 1. Cut the length of the wire between the strip and the
2. Switching power supply line or circuit loss is power cord or use wires with larger diameter
the same or the
too large 2. Ensure that the number of each led module is less than
brightness is not
or equal to the maximum allowable cascade and make
enough
each module with a similar connection.
Adjust the number of modules for each power supply and
3. Over connection of LED module to meet the maximum connection requirements for each
power supply
1. Poor contact at the wiring point Find out the poor contact and troubleshoot.
LED flashing
2. Switching power supply failure Replace the switching power supply