HAD

Adsorption air dryers


HAD 7 ÷ 1300
Compressed Air

A compressor that operates


AIR INTAKE AIR PRESSURE COOLING SYSTEM
in an ambient temperature of 20 °C 10 bar 30 °C
70% UR 100% UR
20°C and 70% relative 760 mm Hg 10 bar
humidity, takes in 12 gr of water 12 grH2O/m3 2,8 grH2O/m3
for every Nm3 of air.

CONDENSATE DRAIN

Compressed air is cooled at 30°C and condensed water vapour is separated, while 2.8 gr of water for every Nm3 of air
that condense can remain in the air (compressed at 10 bar as in the example) in vapour form.

In the event of particularly rapid expansion and/or particular ambient conditions, compressed air for the application may
be cooled to such an extent that the temperature drops below its dew point.

If the temperature falls below its dew point (*), further condensation takes place resulting in separation of humidity and
formation of condensate.
(*) The Dew Point is the value of the temperature when we have the max. water vapour concentration in the air, at one specific pressure.

Over time, this may lead to:


- serious damage to the distribution network, the machines using the compressed air and the final product.
- plugs of ice forming in the tubing in certain situations.

Today compressed air is a primary and essential


COOLING SYSTEM DRYING PROCESS AIR DISTRIBUTION
D.P. – 40 °C 10 bar source of energy for most production processes,
30 °C
100% UR Relative pressure D.P. -40 °C from small businesses to large industries.
10 bar 10 bar
2,8 grH2O/m3 0,011 grH2O/m3 Filtered compressed air is no longer sufficient.
Modern industries require compressed air that
is increasingly filtered with low dew point and
condensate.

Maintaining the correct dew point for


compressed air ensures correct operation
throughout the production process.

ABAC has over 30 years’ experience in drying compressed air, and offers the optimum solution to satisfy any demand.
Drying process

+0 °C
+3 °C 10 bar
+30 °C 10 bar 0,48 /m3 H2O
10 bar 0,5 gr/m3 H2O
2,8 gr/m3 H2O
20°C
70% UR
12 gr/m3 H2O

The cooling process does not allow the temperature to fall below 0°C (solidification of water).
However, specific applications or particular ambient conditions require dew point temperatures of below 0°C.

Only adsorption dryers can achieve this, because condensate separation takes place WITHOUT lowering the
temperature of the compressed air or gas.

Principle
Drying phase:
Wet air from the compressors passes
through inlet filter 1 which removes the
oil and enters in to tower A.
The desiccant contained in it adsorbs
the water vapor molecules. *APF
After a fixed (STD) or variable time (CD)
the 3 way valve 2 deviates the airflow
from tower A to tower B and it becomes
the operative tower.

Regeneration phase:
During the drying phase in the tower A,
P max P max
some dry air is deviated into the top of
tower B, extracting the trapped water
vapor from the desiccant material. A B
During this phase, tower B is open to atm. atm.
the atmosphere, allowing the purge air
to expand.
The silencers 3 on the outlet ensure 1
quiet operation.
2
Pressurization phase: **AEF AHF
Once regeneration has taken place
and tower B is
pressurized, the 3 way valve 2 changes 3
air flow again.
Adsorbent material

Notes: Unsaturated Saturated 3 Way Discharge Prefilters Humidity


* On HAD 7-60 outlet filter is built inside of the desicant cartridges. valve silencer and Postfilter detector
** Recommended but not included on HAD 7-470. (CD)
HAD 7-60 / 115-470 range

HAD 7-60 STD Compact execution


• Versatile installation with multiport system and six • Aluminium head, base and cylinders prevent corrosion.
possible connections. • Easy to maintain:
• Compact, reduced footprint, simple design. - Maintenance operations can be performed without
• This module can be installed horizontally or vertically, disconnecting tubing.
can stand on the floor or be - Assorbent cartridge with built-in postfilter.
mounted on a wall (optional mounting kit available). • Automatic electronic control to manage the dryer and
• The inlet prefilter AHF is delivered loose with the dryer phase status with an automatic
but it can be directly fixed on it. fault diagnosis, including alarms.
• The outlet postfilters APF are integrated in the • Each tower is fitted with a high efficiency silencer for
dessicant cartridges. quiet operation.

Multiport inlet and outlet; 1 Prefilter removes particulates and coalesced


this arrangement ensures easy liquids from the air stream.
and fast installation. 1
2 Removable front panel allows for easy access for
servicing without disconnecting the pipe system. 3
3 Postfilters, integrated in the dryer, removes
particulate in the air stream. 4

4 Electronic control housed in an IP65 box,


3
which enables:
- regeneration cycle management
- regulation status 2
- default diagnosis
- remote default report

Technical Info
• Capacities from 114 up to 990 l/1’ at 7 bar. • Working pressure range 4 - 16 bar.
• Standard dew point - 40 °C. (-70°C. by derating the FAD). • Voltage: 12-24V DC 50/60Hz.
• Max. working pressure 16 bar. : 100-115-230V AC 50/60Hz.

HAD 115-470 STD (CD: control dew point as option)


• Reliable operation with standard • The inlet prefilter AHF and the outlet
components tested for continuous service. postfilter APF, have to be mounted on the
• The compact dryer can be installed air distribution line. 4
on the floor (floor mounted kit as standard). • The filters are included but not pre-mounted.
5

2 3

1 Base frame makes it easy to transport by fork lift. 6

2 Pressure gauge – tower A.


3 Pressure gauge – tower B.
4 Stainless steel purge nozzle.
5 Air outlet connection.
6 Air intlet connection.

1 7 High efficiency silencers with integrated safety valve.

7
Technical Info
• Capacities from 1920 up to 7800 l/1’ at 7 bar. • Max. working pressure 14,5 bar. 7
• Standard dew point -40°C. • Working pressure range 4 - 14,5 bar.
(-70°C. as an option together with derating the FAD). • Voltage: 115-230V AC 50/60Hz.
HAD 650-1300 range

HAD 650-1300 STD: electronic timer control - CD: control dew point
Developed with high quality components, HAD dryers guarantee a stable dew point of -40°C. The use of an optimized desiccant
volume and a wide vessel, ensure a low air speed and a longer contact time.

Purge phases are controlled by an electronic timer on the standard (HAD/STD). There is also control dew point phase is dew point
dependent and is controlled by our electronic dew point management system. The two inlet prefilters AEF-AHF version (HAD/CD)
where the drying phases and the outlet postfilter APF have to be mounted on the air distribution line. The filters are included but not
pre-mounted.

1 Wide vessels for optimum air speed 4 Pressure Dew Point sensor (HAD/CD). 8 Galvanized piping with flanged
and reliable drying. connections.
Unit is rather low for its capacity due 5 Pressure Dew Point digital display
to flanges that are built into the (HAD/CD). 9 High efficiency silencers with
vessels. integrated safety valve.
6 Two manometers integrated in
2 Air outlet connection. the control panel to show 10 Air inlet connection.
pressure in the vessels A/B.
3 Robust frame, including fork lift slots 11 Stainless steel 3 way valve – long
for easy installation. 7 Stainless steel purge nozzle. service interval.

8 7
5
4

1 6

HAD/CD

11

HAD/STD

9 10 9

Technical Info
• Capacities from 10800 up to 21600 l/1’ at 7 bar. • Max. working pressure 11 and 14,5 bar.
• Standard dew point -40°C. • Working pressure range 4-11 bar and 11-14,5 bar.
(-70°C. an option together with derating the FAD). • Voltage: 230V AC 50/60Hz.
Control dew point - CD

How to decrease your consumption?


The electronic Pressure Dew Point control (CD) extends the
drying phase of the dryer’s cycle. It is done by measuring
PDP of compressed air on the dryer outlet and only switching
the columns when desiccant in the active tower is saturated.
The regeneration part of the cycle stays fixed.
As most of the time compressor and dryer runs < 100% load,
this results in a significant extension of the drying time and a
reduction in purge air consumption.
Typically the extra investment in a Pressure Dew Point control
is paid back in a few months by savings made on dryer
running costs.

Quality air with the HAD dryer


Particularly for:

• The chemical and Residual oil


-20 °C 0,01 mg/m3
pharmaceutical Industries. )
(1.1.3*
• Petrochemical plants. tories
Laborating
Pain
• Food industry.
Re
sidu
a
• Transportation of < l pa
hygroscopic materials. 1— rtic
m le
s
• Quality painting.
.1 °C
*)
(1 40
.2

en s
m ne

• Textile production.
ts
-

tru zo
Ins ld

• Semiconductors.
Co

ors
Semiconducts
Arctic zone

• Cable pressurization.
(1.1.1*)
-70 °C

• Beer and drinks production.

• Applications in low-temperature
environments.

* Quality class according to ISO 8573-1

Original parts fit the best.


Only they will guarantee the original performance of your machine.To ensure maximum working efficiency
and a long life time, every part must conform to specific technical standards. With the use of Original Parts
you are certain about the quality, life time, utilized material and the impact on other components. All these
aspects are important to make the right choice for spare parts. Only with original components can you be
sure about these factors. Therefore your best choice is an Original Part.
Technical Data

HAD
Type Max. Operating 1 Air treatment Standard AEF 2 AHF APF Intel / outlet Dimensions Weight
working pressure capacity dew 0,1 —m 0,01 —m 1 —m connections
Pressure point 0,1 mg/m 0,01 mg/mc n.a. mg/mc
bar psi bar l/1” m3/h cfm °C pre filters post filter gas LxWx H Kg
HAD 7 16 232 7,0 114 7 4,1 -40 n.a. AHF 60 3/8” 281x92x445 13
HAD 11 16 232 7,0 168 10 5,9 -40 n.a. AHF 60 3/8” 281x92x504 14

IN THE DRYER
INTEGRATED
HAD 18 16 232 7,0 282 17 10 -40 n.a. AHF 60 3/8” 281x92x635 17
HAD 25 16 232 7,0 426 26 15,3 -40 n.a. AHF 60 3/8” 281x92x815 20
HAD 40 16 232 7,0 708 42 24,7 -40 n.a. AHF 60 3/8” 281x92x1065 24
HAD 60 16 232 7,0 990 59 34,7 -40 n.a. AHF 60 3/8” 281x92x1460 31
HAD 115 14,5 210 7,0 1920 115 67,7 -40 n.a. AHF 120 APF 120 3/4” 550x177x998 50
HAD 145 14,5 210 7,0 2400 144 84,8 -40 n.a. AHF 120 APF 120 3/4” 550x177x998 50
HAD 160 14,5 210 7,0 2700 162 95,3 -40 n.a. AHF 200 APF 200 3/4” 550x177x1243 60
HAD 215 14,5 210 7,0 3600 216 127 -40 n.a. AHF 200 APF 200 1” 550x378x999 100
HAD 250 14,5 210 7,0 4200 252 148 -40 n.a. AHF 340 APF 340 1” 550x378x999 100
HAD 325 14,5 210 7,0 5400 324 191 -40 n.a. AHF 340 APF 340 1” 550x378x1243 120
HAD 360 14,5 210 7,0 6000 360 4,1 -40 n.a. AHF 340 APF 340 1 ½” 550x540x998 150
HAD 470 14,5 210 7,0 7800 468 275 -40 n.a. AHF 510 APF 510 1 ½” 550x540x1243 180
11 159 7,0 10800 648 381
HAD 650 -40 AEF 800 AHF 800 APF 800 1 ½” 960x754x1716 445
14,5 232 12,5 12900 774 456
11 159 7,0 13200 792 466
HAD 800 -40 AEF 800 AHF 800 APF 800 1 ½” 960x754x1716 445
14,5 210 12,5 15900 954 561
11 159 7,0 18000 1.080 636
HAD 1080 -40 AEF 1000 AHF 1000 APF 1000 2” 1064x833x1832 600
14,5 210 12,5 21600 1.296 763
11 159 7,0 21600 1.296 763
HAD 1300 -40 AEF 1500 AHF 1500 APF 1500 2” 1118x859x1869 650
14,5 210 12,5 25800 1548 911

Notes
1 Reference conditions: 2 Filters are delivered loose with the dryer:
- Operating pressure: see the technical - HAD 7-60: the filters can be directly fixed
data table. on the dryer. H
- Operating temperature: 35°C. - HAD 115-1300: the filters have to be
- Relative humidity: 100% mounted on the air distribution line.

For working pressure different from “ operating pressure “ use the correction factors table.

W
L

Correction factors HAD/16 design pressure


Air Inlet Pressure - bar 4 5 6 7 8 9 10 11 12 13 14 14,5 15 16
HAD7 up to HAD60 0,62 0,75 0,87 1 1,12 1,25 1,37 1,5 1,62 1,75 1,87 1,93 2 2,12
HAD115 up to HAD470 0,62 0,75 0,87 1 1,12 1,25 1,37 1,5 1,62 1,75 1,87 1,93 - -

Correction factors HAD/11 design pressure HAD/16 design pressure


Air Inlet Pressure - bar 4 5 6 7 8 9 10 11 11 12,5 13 14 14,5 -
HAD650 up to HAD1300 10 145 0,47 1 1,1 1,2 1,3 1,38 0,89 1 1,04 1,11 1,15 -

Correction factors
Air Inlet Temperature °C. 20 25 30 35 40 45 50 - - - - - - -
HAD7 up to HAD60 1,07 1,06 1,04 1 0,88 0,78 0,55 - - - - - - -
HAD20 up to HAD1300 1 1 1 1 0,84 0,71 0,55 - - - - - - -

Correction factors
Pressure Dew Point °C. -40 -70 - - - - - - - - - - - -
HAD7 up to HAD1300 1 0,7 - - - - - - - - - - - -
CUSTOMER SERVICE ABAC product range

Cod. 6999860020 - 10/2009


A full product support package is available ROTARY SCREW COMPRESSORS
to all of our customers throughout the world. From 2.2 to 55 kW ( from 3,0 to 75 Hp),
Qualified technical advice and support from 8 to 13 bar
is provided in strategic locations and in VARIABLE SPEED VERSION
all major countries. Advice on installation, From 11 to 22 kW ( from 15 to 30 Hp),
selection, additional equipment, maintenance from 6 to 13 bar
management and environmental issues is
available on request.
PISTON COMPRESSORS
•Direct drive oilfree and lubricated
from 1,5 to 3 Hp, up to 100 liter air receiver,
working pressure from 1 to 10 bar
•Belt driven, lubricated, single stage,
two stage from 2 to 25 Hp, from 27 to
1000 liter air receiver, max pressure 15 bar
•Silenced, belt driven, single stage, two
stage from 2 to 10 hp, up to 500 liter air
receiver, working pressure from 1 to 11 bar

COMPRESSED AIR TREATMENT


•Refrigeration dryer from 20 to 1.260 m3/h
•Oil filters from 3 to 0,01 micron and carbon filter
from 2.000 to 41.000 l/min
•Cyclonic separators from 126 to 8.500 m3/h
•Oil-water separators from 120 to 8.500 m3/h
•Air receiver from 100 to 5.000 liter