Feature Comparison
Memory Population Rule
Risers
Thermal Components
Supported Operating System
Block Diagram
Lesson 1 of 6
Feature Comparison
Jason Lee
Feature HS5610 R470
2x Sapphire Rapids (SPR) CPU (Socket E) –
XCC/MCC 1x Intel SRF Processor LGA 4710 Socket E2, up to 350 W
CPU
Up to 250 W TDP with HW configuration (Max TDP)
restriction
PCH Chipset Emmitsburg PCH-less
16x DDR5 DIMMs @4800 MT/s, RDIMM, 128 16x DDR5 16 DIMM @ 6400 MT/s (1 DPC), 5200 MT/s (2
Memory
GB DPC)
Front: 3.5”, 2.5”
Front: E3.S
– 12Gb SAS, 6Gb SATA; 2.5”
– GEN5 EDSFF 2.5”
Storage – GEN3/4 NVMeRear: 2.5”
– 24 Gb SAS4, SATA; 2.5”
– 12 Gb SAS, 6 Gb SATA; 2.5”
– GEN4 NVMe
– GEN3/4 NVMe
Front: Up to 10x 2.5” NVMe
PCIe Storage Front: Up to 8x E3.S; Up to 8x 2.5” NVMe
Rear: Up to 2x 2.5” NVMe
Front: 1 port (USB 2.0), 1 (micro-USB, iDRAC Front:
Direct) – 1x HOST/BMC Direct (USB2.0 type C)
Rear: 1 port (Bottom: USB 3.0) + 1 port (Top: – 1x USB 2.0 type A (optional- LCP KVM)
USB
USB 2.0)
Internal: 1 port (USB 3.0) for IDSDM/internal Rear: DC-SCM two port (USB3.1 type A)
USB card up sell option. Internal: One port (USB 3.1)
Internal: (PERC11) HBA355i, H355, H755,
H755N
External: HBA355e Internal: PERC H965i with DC-MHS compliance
Storage
SW RAID: S160 (Chipset SATA/NVMe) None of SW RAID
Controller
BOSS-N1: Monolithic type for HS5610 6x2.5” BOSS-N1 DCMHS
only, other 1U configurations use Modular
type
Network 2x 1 GbE LOM OCP 3.0 x16
1 CPU: Up to 2 PCIe slots (1 x16 Gen4 + 1
PCIe Slots Up to 2 x16 FH Gen5 PCIe, up to 2x OCP x16
x8 Gen5)
AC (Platinum): 600 W (PE only), 800 W,
1400 W
PSU 800 W Platinum, 1500 W Titanium 60 mm M-CRPS
AC (Titanium): 700 W, 1100 W, 1800 W
LVDC @-48 VDC Input: 1100 W
System – iDRAC iDRAC 10
Management – (CSP only) OSM 2.1 (OpenBMC+)
– Hot plug redundant Hard drives, PSUs
Hot plug redundant Hard drives, Fans, PSUs, BOSS-N1
Hot Access – Cold-plug Redundant Cooling, Hot-plug
Flatbread’s Media (M.2 carrier)
for upsell
Security
15G-class Security (SPI interface) 17G-class Security TPM 2.0 (NPCT760JABYX)
(TPM)
GPU No L4 GPU card
Linux and Windows based OS, SLES, Ubuntu,
OS Linux, SLES, Ubuntu
VMware ESXi
Lesson 2 of 6
Memory Population Rule
Jason Lee
Supported RDIMM configurations (DIMMs per CPU)
1 DIMM (only 32 GB allowed during minimum to POST)
8 DIMMs
16 DIMMs (only 64 GB module is supported)
Sierra Forest 1x 4x 8x (1 DPC) 12x 16x (2 DPC)
Cell 1 Yes - Yes - -
Cell 6 - - Yes - Yes
Ranks per DIMM and Data Width Capacity 1 DPC Speed 2 DPC Speed
1Rx8 16 GB - -
2Rx8 32 GB 6400 -
2Rx4 64 GB 6400 5200
2Rx4 96 GB - -
2Rx4 128 GB - -
The figure below illustrates the high level DDR5 implementation plan for the 1-socket platform with two slots per channel.
Intel’s convention is to have DIMM slot0 further away from the CPU than slot1 within the same channel. The population
rule should follow DDR5 Memory diagram as shown as below.
Population rules for PowerEdge R470
Lesson 3 of 6
Risers
Jason Lee
Slot Mapping
Front Rear
Location Card Support RF1d R2q R4b
BOSS BOSS
PCIe Slot 31 (FLOP
n/a x16
OCP)
PCIe Slot 32 (FLOP
n/a x16
OCP)
PCIe Slot 34 (Front
n/a x4
BOSS)
Low Profile Half
PCIe Slot 1
Length
Full Height Half
PCIe Slot 1 x16
Length
PCIe Slot 2 (FLOP Full Height Half
OCP) Length
PCIe Slot 3 (Rear
n/a x4
BOSS)
Full Height Half
PCIe Slot 4 x16
Length
PCIe Slot 5 (Onboard
n/a
OCP)
Riser Configuration Slot Mapping
Slot Form Board
Configuration Riser/OCP/BOSS Category Bandwidth Power Port
# Factor Location
PCIe Gen4
RC0 BOSS (optional) BOSS 3 BOSS x4 (1C 25.2 W BOSS J_BOSS
connector)
Rear:
x4 optional
BOSS PCIe Gen5
and 1 x16 Onboard OCP x16 (OCP OCP_NIC
onboard OCP OCP 5 OCP 75 W J_OCPNIC
(optional) 4C+ 3.0
connector)
PCIe Gen5
31 OCP x16 (OCP J_SL1,
Flop OCP 75 W SL1, SL2
4C+ J_SL2
connector)
RC3 RF1d
PCIe Gen5
Front: 2 x16
32 OCP x16 (OCP SL11,
FLOP OCP Flop OCP 75 W J_R5
4C+ SL12
(Gen5) and x4
connector)
optional BOSS
PCIe Gen4
BOSS (optional) BOSS 34 BOSS x4 (1C 25.2 W BOSS J_BOSS
connector)
Hybrid Full PCIe Gen5 SL11,
R2Q 1 75 W J_R5
Riser Height x16 SL12
3 PCIe Gen4
RC6 BOSS (optional) BOSS BOSS 25.2 W BOSS J_BOSS
x4
Rear: 2 x16 FH
(Gen5) with x4
optional boss Full
and x16 R4b Cabled 4 PCIe Gen5 SL13,
75 W J_R4
onboard OCP Riser Height x16 SL14
OCP (optional) 5 OCP PCIe Gen4 OCP_NIC
OCP 75 W J_OCPNIC
x4 3.0
Riser Configuration
Riser Configuration for RC0, RC1, RC2 RC3 and RC4.
Riser Configuration for RC5, RC6, RC7 and RC8.
Front Riser Types
R1d
R1d is created for front OCP cards.
RF1c
RF1c is created for front PCIe cards.
Riser 2 Types
R2K Riser
R2U
R2V
R2q
R2t
Riser 4 Types
R4a
R4b
Lesson 4 of 6
Thermal Components
Jason Lee
Fan Type
Fan Type DPN Description Usage
4056 VHP fan (HPR Silver) J7DTN ASSY,FAN,HPR,SLVR,40X56,1U,17G CPU TDP <=350 W
4056 STD fan (Brickfielder) 9P02K ASSY,FAN,STD,40X56,1U,17G CPU TDP <= 250 W
(Left) VHP fan and (Right) STD fan
Air Shroud Type
Air Shroud Type DPN Description Usage
EXT HSK front shroud 5PTF0 SHRD,FRONT,EXT,R470 Bundled with EXT HSK configuration
Remote HSK front shroud FFX7G SHRD,FRONT,REMOTE,R470 Bundled with Remote HSK configuration
(Left) EXT HSK air shroud and (Right) Remote HSK air shroud.
Thermal Restriction
Configuration
8x E3.S (Cold Aisle Front 8x 2.5" SAS/SATA; NVMe
Front Storage 10x 2.5" SAS/SATA
Node) RAID/Direct
Fan Type and VHP/Brickfielder fan
VHP/Brickfielder fan x8 VHP/Brickfielder fan x8
Quantity x8
Extended HSK Extended HSK Extended HSK
200 W
Brickfielder Fan Brickfielder Fan Brickfielder Fan
Extended HSK Extended HSK Extended HSK
205 W
Brickfielder Fan Brickfielder Fan Brickfielder Fan
Extended HSK Extended HSK Extended HSK
225 W
Brickfielder Fan Brickfielder Fan Brickfielder Fan
Extended HSK Remote HSK Extended HSK
250 W
Brickfielder Fan VHP Fan Brickfielder Fan
Remote HSK Remote HSK Remote HSK
300 W
VHP Fan VHP Fan VHP Fan
Remote HSK Remote HSK Remote HSK
330 W
VHP Fan VHP Fan VHP Fan
Remote HSK Remote HSK Remote HSK
350 W
VHP Fan VHP Fan VHP Fan
Legend:
Supported at 35 °C
Maximum 30 °C support
Maximum 25 °C support
Not supported
Extended HSK and VHP fan is required for a 350 W CPU TDP supporting at
35 °C ambient.
Supports CPU TDP up to 250 W with extended HSK and Brickfielder fan in
8x E3.S cold aisle config and 8x2.5” SAS/SATA (NVMe RAID/direct) config
at 35 °C ambient.
Supports CPU TDP up to 225 W with extended HSK and Brickfielder fan on
the 10x 2.5” SAS/SATA configuration at 35 °C ambient.
Lesson 5 of 6
Supported Operating System
Jason Lee
Red Hat Enterprise Linux (RHEL) 9.4
Ubuntu 22.04
SUSE Linux Enterprise Server (SLES) 15 SP6 support for 17G
Lesson 6 of 6
Block Diagram
Jason Lee
System Block Diagram
System block diagram of Sierra Forest (SRP)
PCIe Connection Diagram
PCIe connection diagram
Block Diagram – 8xE3.S NVMe Direct (Cold Aisle)
Storage Block Diagram 01 - 8xE3.S NVMe Direct (Cold Aisle)
Block Diagram – 8xE3.S NVMe Direct
Storage Block Diagram 02 - 8xE3.S NVMe Direct
Block Diagram – 8x2.5” NVMe Direct
Storage Block Diagram 03 - 8x2.5” NVMe Direct
Block Diagram – 8x2.5” NVMe Direct
Storage Block Diagram 04 - 8x2.5” NVMe Direct
Block Diagram – 8x2.5” NVMe RAID
Storage Block Diagram 05 - 8x2.5” NVMe RAID
Block Diagram – 8x2.5” NVMe RAID
Storage Block Diagram 06 - 8x2.5” NVMe RAID
Block Diagram – 8x2.5” SAS/SATA
Storage Block Diagram 07 - 8x2.5” SAS-SATA
DDR Connection Diagram
DDR connection diagram
CPU Memory Architecture Comparison
CPU memory architecture comparison