Download as PDF, TXT or read online on Scribd

NEW GARIA BIMAN BANDAR

A B C D E F G H J K L M N P Q R
STATION
CH: 25418.061

ENTRY STRUCTURE
ROOF BELOW

ANDS3-G-21TTM-AR-1705

ANDS3-G-21TTM-AR-1701
F

ANDS3-G-21TTM-AR-1703
A

ANDS3-G-21TTM-AR-1704
ANDS3-G-21TTM-AR-1702
C

ANDS3-G-21TTM-AR-1705
B D E
13670 14680 1250 18000 18000 16800 1250 13950 16800 12100 9500 1250 14680 14680 13390

29000 107600 43400


STAIRCASE: S-21TTM-21 STAIRCASE: S-21TTM-22
RISER 149.659 RISER 149.659
TREAD 300 TREAD 300
WIDTH 2800 WIDTH 2800

PHE FIRE & WATER RAIN WATER PHE


300MM WIDE CORRIDOR
SHAFT SUPPLY SHAFT DRAINAGE SHAFT SHAFT
GUTTER ROOF BELOW
7185 18547 6500 2500 6650 18397 7185
F.H.C. W3
44 37 36 25 24 13 12 1 1 12 13 24 25 36 37 44
SPACE FOR 17a

2150
D4 D4 D13

2800

2800
TERRACE
C v
SPACE 31c SPACE
C v DN OUTDOOR AC
5425

5425

5120
W B W B
DN
300MM WIDE
S
F
b
2 FOR DB D4 D4a
FOR DB
S
F
b
2
4000
UNITS
41 W6
300MM WIDE
GUTTER SPACE FOR 150MM RAISED GUTTER
PLATFORM FOR 4100

9925
WATER TANK

1750

1750
ELECTRICAL C v

32d ABOVE SHAFT 32e WG


S f
F 11
WATER TANK
D1

6575
F.H.C.
SPACE FOR ESCALATOR: E-21TTM-21 S&T
4500

4345
C v
C v
VIADUCT DB 19752 ESCALATOR: E-21TTM-22 C v C v

3740
C v WG
WG C v
LENGTH 19752 19752 SHAFTS EXPANSION
WG WG
S f
F 11
WG
S f
WG
S f
F 11 LENGTH 19752 SPACE FOR S f
F 11
S f
F 11
S f
F 11
F 11 HEIGHT 6585 JOINT VIADUCT DB
PLATFORM HEIGHT 6585

1475

3575
2100 2100
VIADUCT VIADUCT
27000
16150

4200
7150

3575
1475

ESCALATOR: E-21TTM-24 C v ESCALATOR: E-21TTM-23

3740
SPACE FOR

4345
WG
PLATFORM
4500

C v S f C v C v C v
C v
WG SPACE FOR
WG
S f
C v
WG
S f
LENGTH 19752
S&T
F 11 19752 LENGTH 19752 WG
S f EXPANSION
VIADUCT DB WG
S f
WG
S f

6575
S f
F 11 HEIGHT 6585 19752 HEIGHT 6585 F 11 F 11 F 11
F 11
VIADUCT DB F 11
SHAFTS JOINT
F.H.C.

1750

1750
9925
32f SPACE FOR
WATER TANK
ELECTRICAL 32g
SHAFT TERRACE
300MM WIDE ABOVE 300MM WIDE
5425

5425

44 37 36 25 24 13 12 1 1 12 13 24 25 36 37 44
4000
J

2800

2800
GUTTER TERRACE C v
SPACE SPACE C v GUTTER

2150
W B D4 D4a W B
DN
DN S
F
b
2 FOR DB 31d FOR DB S
F
b
2

F.H.C.
ANDS3-G-21TTM-AR-1706 D4 D4

7185 18547 6800 2500 6800 18547 7185


300MM WIDE FIRE & WATER RAIN WATER CORRIDOR
PHE GUTTER SUPPLY SHAFT DRAINAGE SHAFT ROOF BELOW PHE
SHAFT SHAFT
STAIRCASE: S-21TTM-24 STAIRCASE: S-21TTM-23
RISER 149.659 RISER 149.659
TREAD 300 TREAD 300
WIDTH 2800 WIDTH 2800

E F G H STATION
J K L GENERAL NOTE:-
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS OTHERWISE STATED.
CH: 25418.061 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED.

78900 FINISHING SCHEDULE


3. ALL GRID DIMENSIONS ARE MARKED FROM CENTER LINE.
4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL

1250 S.NO CEILING FINISH


SCHEDULE OF CUTOUT IN STRUCTURE RELEVANT ARCHITECTURAL, STRUCTURAL, PLUMBING, FIRE
FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWINGS.
18000 16800 13950 16800 12100 v NO CEILING FINISH.

S.NO WALL FINISH (INTERNAL) S. NO. CUTOUT NO.


SIZE OF
CUTOUT
5. LOCATION OF COLUMNS TO BE VERIFIED WITH CIVIL/STRUCTURE
DRAWINGS BEFORE EXECUTION.
6. FOR DIMENSION OF STRUCTURAL ELEMENTS PLEASE REFER
B 25MM THK. FLAMED GRANITE ON TREADS. 01 21TTM-C-CO-S-P1 200X200MM SLEEVE RELEVANT STRUCTURE DRAWINGS.
4500 7. ACTUAL SIZE OF CUTOUT AND OPENING AS PER SEM AND M/HVAC
G PLASTER WITH P.O.P CEMENT PRIMER AND TEXTURE PAINT. 02 21TTM-C-CO-S-P2 200X200MM SLEEVE DRAWING.
ELECTRICAL 150Ø SLEEVE 150Ø SLEEVE 150Ø SLEEVE ELECTRICAL 03 21TTM-C-CO-S-P3 200X200MM SLEEVE 8. MASONRY WORK ON THE EXTERNAL FACE OF THE STATION MAY
3830

3830

S.NO SKIRTING / DADO FINISH


SLOPE

SLOPE

SLOPE

SLOPE

SLOPE

IN BEAM IN BEAM IN BEAM VARY AS PER ARCHITECTURAL FEATURES OF THE STATION. THE
1:50

1:50

1:50

1:50

1:50

SHAFT SHAFT b 18MM THK. PREPOLISHED GRANITE ON RISERS. 04 21TTM-C-CO-S-P4 200X200MM SLEEVE
21TTM-C-CO-S-P1 21TTM-C-CO-S-P2 FIRE & WATER RAIN WATER 21TTM-C-CO-S-P3 21TTM-C-CO-S-P4 DETAIL DRAWINGS TO BE SUPPLIED BY RVNL DURING
11000 200X200MM 200X200MM SUPPLY SHAFT DRAINAGE SHAFT 200X200MM 200X200MM 4550 f 25MM THK. POLISHED GRANITE UP TO 1200MM.
ENTRY STRUCTURE CONSTRUCTION.
05 21TTM-C-CO-S-P5 200X200MM SLEEVE
SLEEVE FOR RWP SLEEVE FOR RWP SLEEVE FOR RWP SLEEVE FOR RWP ROOF BELOW 9. FRONT WALL AT ALL SHAFTS NOT TO BE CASTED UNTILL
AREA LEGEND 06

3
S.NO FLOORING FINISH 21TTM-C-CO-S-P6 200X200MM SLEEVE INSTALLATION HAS BEEN DONE.
3270 D10 D10 2 25MM THK. FLAMED GRANITE ON TREADS.
OPERATIONAL ROOMS 07 21TTM-C-CO-S-P7 200X200MM SLEEVE 10. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF RVNL
24 13 12 1
4000 2500 4000 1 12 13 24

19
2150

BEFORE EXECUTION.
2800

2800

2800

SPACE FOR 08
13 31c 07 20 11 21TTM-C-CO-S-P8 200X200MM SLEEVE 11. POSITION OF STUB COLUMNS AS PER ESCALATOR
4965

18MM THK. POLISHED GRANITE STONE &


5000

UP UP BAGGAGE
D1a
PROPOSED
22 SPACE
21 50b D1b SCANNER D1a S.NO. ROOM AREA (SQM)
MANUFACTURE'S DETAIL.
12. TENDER DRAWING INDICATES THE EXTENT OF WORK INVOLVED
5000 3430 REFERENCE DRAWINGS:- HOWEVER THE ACTUAL WORK SHALL BE EXECUTED AS PER
FOR DB S&T ELECTRICAL 18 17a UNISEX TOILET ROAD LEVEL PLAN - ANDS3-C-21TTM-AR-1101
1750

1750

2.49 (2.25 X 1.11) DETAILED DRAWINGS/SPECIFICATIONS FOR WHICH NO


D1b 32d SHAFTS SHAFT
32e D1b D1b G H J 31a - 31c LIFTS CONCOURSE LEVEL PLAN - ANDS3-C-21TTM-AR-1301 ADJUSTMENT FOR PRICE BE ADMISSIBLE AND THE PAYMENT
ROOF LEVEL PLAN - ANDS3-C-21TTM-AR-1501 SHALL BE AS PER RESPECTIVE ITEM IN PRICING DOCUMENT.
32a - 32g ESCALATOR SECTION AA - ANDS3-C-21TTM-AR-1701 13. OPENING SIZE MAY VARY DUE TO SITE CONDITION.
SECTION BB - ANDS3-C-21TTM-AR-1702 14. LIFT SHAFT PIT AND ESCALATOR PIT SIZES ARE AS PER THE
1250 13950 41 SIGNAL PANEL ROOM 18.09 (4.10 X 5.12)
PASSAGE ROOF PLAN SECTION CC
SECTION DD
- ANDS3-C-21TTM-AR-1703
- ANDS3-C-21TTM-AR-1704
INFORMATION PROVIDED BY GM/ELECT/III KOL-PIU.
15. WORKING DRAWING SHALL BE BASED ON CRD, SITE INFORMATION
S&T ELECTRICAL SECTION EE & FF - ANDS3-C-21TTM-AR-1705 PROVIDED AND INSTRUCTIONS FROM RVNL.
SHAFT SHAFT LONG SECTION JJ - ANDS3-C-21TTM-AR-1705
LADDER WATER
TANK SYMBOL LEGEND
E F G H J K L

2150
2890
31d S.NO. SYMBOL SYMBOL DESCRIPTION
STATION
CH: 25418.061 1 01 ESCALATOR WITH DIRECTION OF MOVEMENT

78900 3730 2500 02 R GRID LINE WITH GRID NUMBER

1250 300MM WIDE


GUTTER
FIRE & WATER
SUPPLY SHAFT
RAIN WATER
DRAINAGE SHAFT
03 LEVEL IN PLAN

18000 16800 13950 16800 12100 WATER TANK LEVEL PLAN


04 SECTION LINE
NOTES:

A
1. ACID PROOF TILES APPROVAL VIDE LETTER NO. RVNL-KOL-METRO-ANS3-1-74 -604 dt. 26.05.21
05 ANDS3-G-21TTM-AR-1701 SECTION LINE WITH SECTION NO & SHEET NO.
S&T ELECTRICAL
G H J 06 DRAIN PIPE
2. VITRIFIED TILES APPROVAL VIDE LETTER NO. RVNL-KOL-METRO-ANS3-1-74 -614 dt. 28.05.21
1750

1750

1830

SHAFTS SHAFT
32f 32g D1b D1b
07 PLATFORM AREA 3. INCORPORATION OF DOOR ''D1f" INSTEAD OF D3 IN A.S.S/ T.S.S ROOM AS PER LETTER No. RVNL-KOL-METRO-ANS3-1-1183
dated 21.03.22
22 40 09 08 06 1250 13950
5215

DOOR & WINDOW SCHEDULE 4. APPROVAL OF 'D1f' DOOR AS PER LETTER No. 1103 dated 15.02.22
50c D1 D1b
2800

2800

11
2570

300MM WIDE FIRE & WATER RAIN WATER


2150

14 UP
4000
31d 4000
UP GUTTER SUPPLY SHAFT DRAINAGE SHAFT
D/W
NO.
OPENING
CILL LEVEL LINTEL LEVEL PARTICULARS
5. APPROVAL OF P.O.P TO PUTTY& PAINTING AS PER LETTER No. ITDCEM/RVNL/ANS3/2021/DW/556
3270 4000 2002 24
13 12 1 2500 1 12 13
24 5900 4000 2900 3540 3730 2500 *WIDTH HEIGHT
6. APPROVAL OF GRANITE FLOORING IN PLACE OF KOTA FLOORING AS PER LETTER No. RVNL/KOL/METRO/ANS3/1/28/76
1 200X200MM
D10

200X200MM 200X200MM
D10

200X200MM 3
D1

D4
1050
750
2100
1800 300
- 2100
2100
METAL DOOR
METAL DOOR
DATED-19.08.2020
7. APPROVAL OF USE HONED GRANITE STONE IN TREADS AND LANDING OF STAIRCASE,ALL FLOORS & FLAMED GRANITE
2890
SLOPE

SLOPE

SLOPE

SLOPE

SLOPE
2900

2900

FIRE & WATER RAIN WATER


2150

SLEEVE FOR RWP SLEEVE FOR RWP SLEEVE FOR RWP SLEEVE FOR RWP
1:50

1:50

1:50

1:50

1:50

D4a 750 1800 300 2100 FIRE RATED DOOR


ELECTRICAL
21TTM-C-CO-S-P5 21TTM-C-CO-S-P6 SUPPLY SHAFT DRAINAGE SHAFT 21TTM-C-CO-S-P7 21TTM-C-CO-S-P8
ELECTRICAL 31c D10 1000 1485 3600 5085 METAL DOOR
AT PLATFORM COPING FOR ALL ATATIONS LETTER No. RVNL/KOL/METRO/ANS3/1/74/699
SHAFT SHAFT
PRE LAMINATED PARTICLE BOARD
8. APPROVAL OF 18MM THK. POLISHED GRANITE FOR WALL FINISH AS PER DRAWING No. ANDS2/W/15SC1/AR/2303
D13 750 2100 ±0.00 2100
150Ø SLEEVE 150Ø SLEEVE 150Ø SLEEVE 4500 WATER
IN BEAM IN BEAM IN BEAM TANK W3 600 1350 900 2250 FIXED WINDOW WITH EXHAUST FAN 9.APPROVAL OF 30MM THK. POLISHED GRANITE FOR FLOOR FINISH AS PER DRAWING No. RVNL/ITDC/ANS-3/1/21TTM/AR/02A
PASSAGE ROOF PLAN LADDER
S&T
SHAFT
ELECTRICAL
SHAFT
W6 2000 1200 900 2100 OPENABLE WINDOW 10.APPROVAL OF INTIMATION 60MM FLAME GRANITE STONE AT PLATFORM EDGE LETTER No. RVNL/KOL/METRO/ANS-3/1/74/825
NOTE :- ALL HEIGHTS ARE TO BE MEASURED FROM HIGHEST FINISHED FLOOR LEVELS.
* WIDTHS MENTIONED ARE ROUGH MASONARY OPENINGS.
WATER TANK LEVEL PLAN

PROJECT MANAGERS: DETAILED DESIGN CONSULTANT RAIL VIKAS NIGAM LIMITED


Cem ITD Cementation India Limited
TANDON CONSULTANTS PVT. LTD. - FOUNTAINHEAD - JV METRO RAILWAY, KOLKATA (A Government of India Enterprise)
1ST FLOOR, AUGUST KRANTI BHAWAN, PLOT NO. 25, BHIKAJI CAMA PLACE, R.K. PURAM, NEW DELHI - 110066
THIS DRAWING IS THE PROPERTY

TCPL-FH JV'S SCOPE OF WORKS DOES NOT INCLUDE SUPERVISION OF CONSTRUCTION FOR THIS PROJECT. THESE
DRAWING REPRESENT THE "AS-BUILT"STATUS OF CONSTRUCTION ON SITE AS CONFIRMED BY THE
"Godrej Waterside", Tower No. 1, Office #803, 8th Floor, Plot No. 5,
OF RAIL VIKAS NIGAM LTD.

CONTRACTOR/SUPERVISION AGENCY.ALL THE SKETCHES, FCR, OTHER CHANGES INFORMED VIDE EMAIL'S SITE
Commitment , Reliability & Quality
Block -DP, Sector - V, Salt Lake City, Kolkata -700091 METRO CORRIDOR - NEW GARIA TO BIMAN BANDAR, KOLKATA
INSTRUCTION REGISTER ETC.PREPARED AND ISSUED DURING CONSTRUCTION STAGES OF THE PROJECT AND AS
SUPPLIED BY CONTRACTOR HAVE BEEN INCORPORATED IN "AS BUILT"DRAWING.
PH. +033-23412400 FAX: +033-23412410

21TTM
METRO RAILWAY STAMP

20SC2
CONTRACT: ANS3: CONSTRUCTION OF 7 ELEVATED METRO STATIONS
TANDON CONSULTANTS PVT. LTD. WITHOUT FIELD CHANGE REQUEST
23VPR
22RBT
19CVC
INCLUDING RELATED WORKS FROM SUB CBD1 TO TITUMIR
17, LINK ROAD, JANGPURA EXTN. NEW DELHI-110014. PH. +91-11-24317684, 24319288, 24310509 FAX:
IN NEW GARIA-AIRPORT CORRIDOR OF KOLKATA

14BDN
18NTN

13TNP
+91-11-24316057 EMAIL: tandon@tcpl.com, tcpl_123@yahoo.com 17CB2
1ST FLOOR, AUGUST KRANTI BHAWAN, PLOT NO. 25, BHIKAJI CAMA PLACE, R.K. PURAM, NEW DELHI - 110066 WITH FCR BUT NO CHANGE IN DESIGN 12SLV
ARCHITECT & SERVICE CONSULTANTS 16CB1

15SC1
11NCO

FOUNTAINHEAD

ARCHITECTURE
10GKG
RVNL'S SCOPE OF WORKS INCLUDE DESIGN COORDINATION AND CONSTRUCTION SUPERVISION FOR THIS PROJECT.THESE DRAWING WITH FCR AND CHANGE IN DESIGN TITUMIR
09BLG STATION:
REPRESENT THE "AS BUILT"STATUS OF CONSTRUCTION ON SITE. FAX: C-9/9148, VASANT KUNJ, NEW DELHI - 110070. TEL: +91 11 26891534 +91-11-26898459 08BSG N
EMAIL: office@studiofountainhead.com 07RWG
06VBZ
NAME & DESIGNATION SIGN & DATE NAME & DESIGNATION SIGN & DATE
METRO RAILWAY DRAWING NO:
05HMJ
04KSK
03JNN
TITLE: PLATFORM LEVEL PLAN
AB
MR. N.K.SINGH MRS.S.KASHYAP MR. H.SINGH MR.KAMALESH CHAKRABORTY MR. S.K.MUKHOPADHYAY MR.R.KRISHNA DATE:
MR.PRAVEEN KUMAR MR.RAJAT MATHUR
SHAULI CHAKRABORTY MOUSUMI CHAUDHURI MR.ANIRUDDHA GHOSAL MR.SUKHAMOY MAHADANI
02SRY REV. SCALE STATUS
GM / METRO-CIVIL / CO. SR / DGM / ARCHITECTURE CPM / KOL-II AGM / CIVIL / EXPERT / KOL-II AGM / ELECTRICAL / KOL. GM/S&T/KOL. (VICE PRESIDENT) (CHIEF ARCHITECT) 01KSU DWG NO : RVNL-ANS3-ITD-AB -21TTM-AR-1401 AB-0 1:250 08.12.23 AS BUILT
PREPARED BY (CAD OPERATOR) CHECKED BY (DY.PROJECT MANAGER) PEER CHECKED BY (CHIEF SURVEYOR) APPROVED BY (PROJECT MANAGER) STATION LOCATION