4CA2-T10049 01 Dang
4CA2-T10049 01 Dang
SIME Brakes
Caliper 4CA2
Fail safe braking Working conditions: Options:
Braking by spring application • Ambient température: -10°C to +60°C • Manual release lever
Electromagnetic release • Relative humidity ≤ 70% • Hydraulic release
Automatic wear compensation • Dust in atmosphere ≥ 65µ • Manual wear compensation
Opening proving switch Other conditions, consult us. • Flameproof protection
Brake pads with wear indicator • Marine protection
Use: • Closing proving switch
Any application up to 1000act/h • Switch on release nut
17°30 350
G 20
l
355
Opening switch
Cable gland PG16
260 E F
50
135 117.5
4 × Ø 22 Ød
Weight: 120kg
Response time at nominal torque : see the leaflet of the associated electrical power supply.
Technical data :
Discs 445 495 550 625 705 795
Nominal torque for 1 caliper Opening proving switch :
N.m 950 1100 1270 1500 1750 2000
adjustable from -30 to +20% 250VAC maxi., 5A maxi., with interrupting
Maximum disc speed for capacity : 50VA maxi.
r.p.m. 2100 1900 1800 1500 1300 1200
nominal torque 220VDC maxi., 5A maxi., with interrupting
capacity : 50W maxi.
D mm 445 495 550 625 705 795
d mm 0-70 0-100 0-100 0-100 0-120 0-130 Compatible with PLC (Programmable Logic
E mm 130 160 180 215 255 295 Controllers).
F mm 110 140 160 195 235 275 An opening switch used with other equipment
G mm 225 235 240 250 260 275 than PLC must not be reused with a PLC.
l (approx. dimension) mm 90 125 145 180 225 265
Due to continuous development and improvement, all dimensions and characteristics are subject to change without notice.