0% found this document useful (0 votes)
10 views6 pages

Eletroválvula Rexhoth

Uploaded by

wesckeyrodrigues
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views6 pages

Eletroválvula Rexhoth

Uploaded by

wesckeyrodrigues
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

1/6

RE 18309-53/06.10
Replaces: RE 18309-53/04.10

3-Way heavy duty flow control,


with pressure compensated and
solenoid controlled priority flow
A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z

Description
The flow control valves series “A-VRFC3C-VEI-VS” are 3 way, with one inlet “P” and
two outlets “A” and “B”, the first outlet “A” being priority, pressure compensated type,
with pressure relief valve and available on demand through a solenoid cartridge; the
second outlet “B” is the by-pass for all flow in excess of what demanded by priority.
Both flows from “A” and “B” ports can be employed to power different functions of
the machine.
These valves provide a simple and efficient way to power hydraulic tools (such as
hydraulic hammers) from the existing hydraulic system, without any need to modify
the directional control valve.
They allow the simultaneous operations, independently from the respective working
pressures, of both the hydraulic actuator powered by the priority outlet “A”, and
of the normal functions of the machine (traction, slewing, cylinder motions, etc.)
supplied by the main directional valve through the by-pass outlet “B”.

Technical data
Hydraulic
Max. operating pressure bar (psi) 350 (5000)
Max. priority line pressure: limited by relief valve (6). See “priority pressure range”
table on page 5.
Back pressure at T port bar (psi) max 1.5 (20)
Drain from T, with
l/min (gpm) up to 1.5 (0.4)
solenoid valve non-energized

General
Manifold material Steel
Weight See “Dimensions”
Viscosity 20 to 380 mm2/s (cSt)
Fluid temperature range °C (°F) between -20 (-4) and +80 (176)
Other technical data see data sheet RE 18350-50

Note: for applications outside these parameters, please consult us.


2/6 Bosch Rexroth Oil Control S.p.A. 0M432080YZ RE 18309-53/04.10

Performance graphs

Priority Flow vs Pressure By-pass line pressure drop


RE 18309-53/04.10 0M432080YZ Bosch Rexroth Oil Control S.p.A. 3/6

Dimensions

32 5 70 86 54.5 62.5 88.5 48 76 190 68 18 90 14 92 41 34 130 9


(1.26) (0.2) (2.76) (3.39) (2.15) (2.46) (3.48) (1.89) (2.99) (7.48) (2.68) (0.71) (3.54) (0.55) (3.62) (1.61) (1.34) (5.12) (0.35) G 1-1/4 12.5 (27.5)
32 5 60 74.5 46.5 56.5 78 36.5 76 173 68 15 90 13.5 80.5 41 34 120 9
(0.35) G 1 9 (19.8)
(1.26) (0.2) (2.36) (2.93) (1.83) (2.22) (3.07) (1.44) (2.99) (6.81) (2.68) (0.59) (3.54) (0.53) (3.17) (1.61) (1.34) (4.72)
32 5 50 59 37 44 61 34 50 140 73 13.5 73 13 69.5 41 34 100 9
(1.26) (0.2) (1.97) (2.32) (1.46) (1.73) (2.4) (1.34) (1.97) (5.51) (2.87) (0.53) (2.87) (0.51) (2.74) (1.61) (1.34) (3.94) (0.35) G 3/4 4.8 (10.6)
32 5 40 54.5 35.5 38 56.5 29.5 50 130 76 8.5 73 12.5 60 41 34 90 8.5
(0.34) G 1/2 3.4 (7.5)
(1.26) (0.2) (1.58) (2.15) (1.4) (1.5) (2.22) (1.16) (1.97) (5.12) (2.99) (0.34) (2.87) (0.49) (2.36) (1.61) (1.34) (3.54)

S2 S1 S L6 L5 L4 L3 L2 L1 L I H6 H5 H4 H3 H2 H1 H F Port Weight
sizes kg (lbs)

Fitting and connections


When positioning and tightening the valve, avoid any deflection of the body which could prevent the internal spool from sliding freely and
impair the metering performance; it is recommended to use the 3 available fixation holes as locating points and to fit 3 equal spacers
(metal washers), one on each point, between the valve body and the supporting structure.
Connections to the hydraulic system:
• Port “P” (inlet) to the main line from the pump.
• Port “A” (priority outlet) to the line feeding the hydraulic hammer, or the attachment. Important: for the correct metering of the
compensating spool the priority outlet shall be always pressurized, with a back-pressure of at least 8-9 bar (115-130 psi); if
necessary, fit a check valve with the needed cracking pressure.
• Port “B” (by-pass, or excess flow outlet) to the line delivering the oil to the main directional valve.
• Port “T” to a tank line. It is absolutely necessary that port “T” is connected to a low pressure tank line, 1-1.5 bar max (15-22 psi
max).

Sleeve type check valves Cracking


Port sizes Dimensions mm (inches)
pressure Ordering code
A-B C L L1
bar (psi)
043117000301000
G 1/2 8 (115) 30 (1.18) 57 (2.24) 14 (0.55)
R930000444
043117000401000
G 3/4 8 (115) 36 (1.42) 69 (2.72) 16 (0.63)
R930000445
043117000501000
G1 8 (115) 46 (1.81) 82 (3.23) 18 (0.71)
R930000446
043117000601000
G 1 1/4 8 (115) 55 (2.17) 102 (4.02) 20 (0.79)
R930000447

Adjustment of priority flow


The volume of priority flow from port “A” can be easily modified by turning the screw (1): the flow increases by turning the screw counter-
clockwise and, once adjusted to the desired level, it remains constant independently from the working pressure.

Adjustment of maximum priority pressure


The maximum pressure in the priority line “A” can be adjusted by turning the screw (5) of the small relief cartridge (6) which controls
the maximum pressure in the chamber (3): when this “pilot” cartridge opens, the pressure in chamber (3) drops and the priority flow is
stopped.
Note: the relief cartridge (6) controls only the maximum pressure in the priority outlet “A”, and does not control the pressure in the by-pass
and main line: the main line must be protected by another relief valve, capable to discharge the full oil flow.
4/6 Bosch Rexroth Oil Control S.p.A. 0M432080YZ RE 18309-53/04.10

Ordering code: OD.02.17 - X - Y - Z COILS Attention: indicated coils fit every hammer valve versions

TECHNICAL DATA
Weight: 0.180 kg (0.4 lbs)
Encapsulating material: IXEF
Heat insulation Class H: 180°C (356°F)
Ambient temperature range: -30/+60°C (-86/+140°F)
Inlet voltage fluctuations must not exceed ±10% of nominal voltage to obtain correct
operation and long life coils.

X Y Connections Circuit Voltage


01 30 DIN 43650 - ISO 4400 Standard DC-RAC
07 30 AMP JUNIOR Standard DC only
0G 03 SINGLE LEAD Standard DC only *
14 30 DIN 43650 - ISO 4400 Bidirectionl Diode DC only
15 30 AMP JUNIOR Bidirectional Diode DC only
0H 03 SINGLE LEAD Bidirectional Diode DC only *
* Length 300mm (11.8 inches). Ext. diameter 6.3mm (0.25 inches). External and internal Shealth Silicone rubber.

Voltage V Resistance Ohm (±7%) Power W Current A ∆T °C (°F)


1 hour energized
Z Nominal Ta = 20-25°C (68-77°F) Cold coil Cold coil Hot coil
at Ta=20-25°C
(68-77°F)
Nominal voltage

OB 12 DC 7.4 20 1.62 1.19


OC 24 DC 28.5 20 0.85 0.61 105-110
(221-230)
OG 14 DC 20
AC 26 DC 34.3 20 0.76 0.54

X Y Connections Circuit Voltage


20 30 DEUTSCH DT04-2P-L Standard DC only
20 3P DEUTSCH DT04-2P-V Standard DC only
30 3P AMP SUPERSEAL-V Standard DC only
22 30 DEUTSCH DT04-2P-L Bidirectionl Diode DC only
22 3P DEUTSCH DT04-2P-V Bidirectional Diode DC only
32 3P AMP SUPERSEAL-V Bidirectional Diode DC only

Voltage V Resistance Ohm (±7%) Power W Current A ∆T °C (°F)


1 hour energized
Z Nominal Ta = 20-25°C (68-77°F) Cold coil Cold coil Hot coil
at Ta=20-25°C
(68-77°F)
Nominal voltage

OB 12 DC 7.4 20 1.62 1.19


105-110
OC 24 DC 28.5 20 0.85 0.61
(221-230)
AC 26 DC 34.3 20 0.76 0.54

Protection IP69 - DIN 40050 part 9


These coils have passed the THERMAL SHOCK DUNK TEST

Note: Please refer to data sheet RE 18325-90 for coils and


connectors readily available and for further details.

SPARE PARTS
SOLENOID CARTRIDGE RELIEF CARTRIDGE
Port size Ordering code Port size Ordering code
0M.43.20.80.03.20 0M.43.20.80.03.20
0M.43.20.80.03.35 OD1502181AS000 0M.43.20.80.04.20 041148035620000
0M.43.20.80.04.20 R901091102 0M.43.20.80.05.20 R901104097
0M.43.20.80.04.35 0M.43.20.80.06.20
0M.43.20.80.05.20 0M.43.20.80.03.35
0M.43.20.80.05.35 OD132067390000 0M.43.20.80.04.35 041148035635000
0M.43.20.80.06.20 R934000629 0M.43.20.80.05.35 R901104099
0M.43.20.80.06.35 0M.43.20.80.06.35
RE 18309-53/04.10 0M432080YZ Bosch Rexroth Oil Control S.p.A. 5/6

Ordering code
0M.43.20.80 Y Z

Priority pressure range


3-Way heavy duty flow control, with pressure Adj. pressure Pres. increase Std. setting
compensated and solenoid controlled priority flow range bar/turn Q=5 (l/min.)
bar (psi) (psi/turn) bar (psi)
50-210 48 200
= 20
(725-3000) (696) (2900)
100-350 95 350
= 35
(1450-5000) (1378) (5000)
Inlet flow
Port sizes Regulated priority flow
(max)
l/min (gpm) l/min (gpm)
P-A-B T l/min (gpm)
max per turn

= 03 G 1/2 G 1/4 100 (26) 85 (23) approx. 18 (4.8)

= 04 G 3/4 G 1/4 200 (53) 140 (37) approx. 20 (5.3)

= 05 G1 G 1/4 300 (79) 220 (58) approx. 26 (6.9)

= 06 G 1-1/4 G 1/4 400 (106) 300 (80) approx. 28 (7.4)

Type Material number Type Material number


0M432080032000C R930004377
0M432080033500C R930004378
0M432080042000D R930000028
0M4320800435000 R930006085
0M432080052000D R930004383
0M432080053500A R930006086
0M432080062000D R930004385
0M4320800635000 R930000353
6/6 Bosch Rexroth Oil Control S.p.A. 0M432080YZ RE 18309-53/04.10

Bosch Rexroth Oil Control S.p.A. © This document, as well as the data, specifications and other information set
Via Leonardo da Vinci 5 forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a.. It may
P.O. Box no. 5 not be reproduced or given to third parties without its consent.
41015 Nonantola – Modena, Italy The data specified above only serve to describe the product. No statements
Tel. +39 059 887 611 concerning a certain condition or suitability for a certain application can be
Fax +39 059 547 848 derived from our information. The information given does not release the user
from the obligation of own judgment and verification. It must be remembered that
[email protected] our products are subject to a natural process of wear and aging.
www.boschrexroth.com
Subject to change.