Accura 2500/2550 User Guide [AC] Notice
Notice
Symbols
Caution
Indicates the presence of dangerous voltage which can cause severe injury or death if proper
precautions are not followed.
Caution
Alerts users of the presence of hazards which can cause injury to persons, property damage
or damage to the device if proper precautions are not followed.
Note
Indicates major instructions for the installation, operation, and maintenance of the product.
Installation Considerations
The installation, operation, and maintenance of the product should be performed only by qualified,
competent personnel that have received appropriate training for high voltage and current devices.
Caution
If hazardous voltages are mishandled while installing and operating the product in the field, it can cause
serious injury or death.
◼ This device must be installed and serviced only by qualified personnel who have in-depth knowledge of
installing, commissioning and operating the device and have had appropriate training. He or she should
have read and understood the various safety measures and warnings stated in the instructions.
◼ Before carrying out any work on the device, switch off the power supply to the device.
◼ Always use an appropriate voltage detection device to confirm the absence of voltage.
◼ Always power the device with the correct rated voltage.
◼ Install the device in a suitable electrical cabinet by following recommended installation instructions.
Failure to take these precautions could cause serious injuries or death.
Caution
Observe the following instructions, or permanent damage may occur to the product.
In the absence of written agreements, Rootech Inc. assumes no liability for applications assistance,
customer’s system design, or infringement of patents or copyrights induced by third parties arising from
the use of the products described herein.
We are committed to providing accurate information in this document. However, we assume no responsibility
for any errors in the document and reserves the right to make changes without notice.
Limitation of Liability
Where applicable law allows and does not prohibit or restrict such limitation, Rootech, Inc’s liability for this
product shall be limited to the amount actually paid by customers for the product.
Warranty
Rootech Inc. provides a warranty for two years from the product receipt date, applicable only to the original
purchaser of the products and software sold or licensed by the company.
To obtain warranty service, the purchased products should be free from serious defects in material and
workmanship.
Software products are provided in an up-to-date version, therefore, we do not offer any warranty for software
product.
In order to make a product claim under the warranties described above, the original purchaser should
immediately contact Rootech headquarters. When we receive a claim, we will inspect the product either at
the purchaser's location or at the company’s facility after receiving the product from the customer. The
customer is responsible for the cost of shipping the product. After inspecting the product, we will provide
repair or replacement services for the product.
Rootech Inc. reserves the right to determine, at its discretion, whether to repair or replace the product or
issue a refund for the product when the warranty period has expired or issues are not covered by warranty
terms and conditions.
Limitation of Warranty
The warranty does not apply to the uninterrupted or error-free operation of the product and does not cover
normal wear and tear. It also does not cover costs associated with the removal, installation, or
troubleshooting of the customer's electrical systems.
Defects caused by any of the following factors are not covered under the warranty.
◼ Improper use(alteration, accident, misuse, abuse) or failure to act in accordance with installation,
operation or maintenance instructions
◼ Unauthorized modifications, changes or repair attempts
◼ Failure to comply with applicable safety standards and regulations
◼ Damages incurred during transportation or storage of the product
◼ Damages caused by the force majeure event, including fire, flood, earthquakes, storm damage,
overvoltage and lightning
◼ Defacing, altering, or removal of the original identification marks(trademark, serial number, etc.)
Rootech Inc. shall not be liable for any claims other than those made by customers, including the original
purchaser, their employees, agents, or contractors for any loss, damage, or expense incurred related to the
purchased product when the above warranty terms and conditions are not fulfilled.
Any technical assistance provided by Rootech's personnel or representatives in system design shall be
considered a suggestion. The original purchaser is responsible for determining the feasibility of such
suggestions and should conduct tests to verify their feasibility
It is the original purchaser’s responsibility to determine the suitability of any product and associated
documentation. The original purchaser should acknowledge that 100% uptime is not achievable due to
possible hardware or software defects. The original purchaser should also recognize that such defects and
failures may cause inaccuracies or malfunctions.
No agency, corporate entity, or employee of Rootech Inc. or any other companies has the authority to amend,
modify or extend the terms and conditions of this warranty in any way without express written authorization
from Rootech, Inc.
Standards Compliance
R-R-RTE-Accura2500
Revision History
The revision history of the Accura 2500/2550 User Guide[AC] is as follows.
Revision 1.70 April 12, 2024 Added CMZ-3P4W-250A, CMS/ZM, and CMM modules
Deleted CM-3P-630A-210/400A-145 modules
Added content on transient voltage events
Updated descriptions of the Aggregation section
Updated information on UL certifications
Added special modules, including Accura 2550SAL/VOL/GWM
Extended the setup range for the LCD screen of Accura 2500D
Added the image and description related to RS-485 shielded cables
Changed the low level range of the LCD backlight brightness
Added content on the residual current measurement function of all three-
phase modules.
Revision 1.80 June 28, 2024 Added Accura 2500M-AC220V/DC110V, Accura 2500M-DC24V options
Updated information on UL certifications
Changed measured voltage range
Changed terminal block torque of voltage input terminal
Updated the measurement parameters provided via communication
Added description of pickup event and changed definition of Duration
Changed range of backup/setup energy
Revision 1.90 October 25, 2024 Added CM-3P modules, which can connect an external ZCT (800A, 630A,
400A, 5A)
Added CMZ-3P-630A-155, CMMZ-3P-60A modules
Added DCM, IO Special purpose modules
Added installation method for CM[Z]-3P module without clear distance
between panels
Added a usage guide table for the leakage current measurement module by
load type
Added Status view description
Changed Appendix B module power consumption
Contents
Chapter 1 Introduction .................................................................................................................................................... 27
Overview .................................................................................................................................................................................................................. 27
Product Information ........................................................................................................................................................................................... 29
Smart Industrial Control Panel Digital Power Meter/Power & Leakage Current Measuring Modules ............. 29
Special-Purpose Modules ....................................................................................................................................................................... 33
Installation Example .................................................................................................................................................................................. 34
Product Features ......................................................................................................................................................................................... 36
Figures
Fig 1.1 Accura 2550 Modules Compatible with MCCBs with Various Ratings............................................................... 28
Fig 1.2 Through-Hole Type Current Sensing Structure of Accura 2550 Modules ........................................................ 28
Fig 1.3 Combined Installation of Accura 2500D and 2500M ................................................................................................. 34
Fig 1.4 Connection of Accura 2500D and 2500M Using Communication Cables ....................................................... 35
Fig 2.1 Accura 2500M Front ................................................................................................................................................................... 46
Fig 2.2 Accura 2500M Side ..................................................................................................................................................................... 46
Fig 2.3 Accura 2500M Rear .................................................................................................................................................................... 46
Fig 2.4 Accura 2500D Front .................................................................................................................................................................... 47
Fig 2.5 Accura 2500D Side...................................................................................................................................................................... 47
Fig 2.6 Accura 2500D Rear ..................................................................................................................................................................... 47
Fig 2.7 Accura 2550CM-3P/1P .............................................................................................................................................................. 48
Fig 2.8 Accura 2550CMZ-3P/1P ........................................................................................................................................................... 49
Fig 2.9 Accura 2550CMZ-3P4W............................................................................................................................................................ 49
Fig 2.10 Accura 2550CMS-3P4W/1P3F/1P2F ................................................................................................................................. 49
Fig 2.11 Accura 2550ZM-3P4W/1P3F/1P2F .................................................................................................................................... 50
Fig 2.12 Accura 2550CMM...................................................................................................................................................................... 50
Fig 2.13 Accura 2550CMMZ ................................................................................................................................................................... 50
Fig 2.14 TM-CM[Z]-3P............................................................................................................................................................................... 51
Fig 2.15 TM-CM[Z]-1P............................................................................................................................................................................... 51
Fig 2.16 TM-CM[Z]-BC-3P ....................................................................................................................................................................... 51
Fig 2.17 TM-CM[Z]-BC-3P4W ................................................................................................................................................................ 51
Fig 2.18 Accura 2500M Components ................................................................................................................................................ 52
Fig 2.19 Accura 2500D Components ................................................................................................................................................. 52
Fig 2.20 Accura 2550CM-3P-800A/630A/400A Components ................................................................................................ 52
Fig 2.21 Accura 2550CMZ-3P 800A/630A/400A Components .............................................................................................. 53
Fig 2.22 Accura 2550CM[Z]-3P-250A/125A/100A/60A Components................................................................................. 53
Fig 2.23 Accura 2550CM-3P-800A/630A/400A/5A-ZCT Components............................................................................... 54
Fig 2.24 Accura 2550CMZ-3P4W-250A Components ................................................................................................................ 54
Fig 2.25 Accura 2550CM[Z]-1P-250A Components .................................................................................................................... 55
Fig 2.26 Accura 2550CM[Z]-1P-125A/100A/60A Components ............................................................................................. 55
Fig 2.27 Accura 2550CMS-3P4W/1P2F Components................................................................................................................. 55
Fig 2.28 Accura 2550CMS-1P3F Components ............................................................................................................................... 56
Fig 2.29 Accura 2550ZM-3P4W Components ............................................................................................................................... 56
Fig 2.30 Accura 2550ZM-1P3F Components.................................................................................................................................. 56
Fig 2.31 Accura 2550ZM-1P2F Components.................................................................................................................................. 57
Fig 2.32 Accura 2550CMM Components ......................................................................................................................................... 57
Fig 2.33 Accura 2550CMMZ Components ...................................................................................................................................... 57
Fig 2.34 TM-CM[Z]-3P Components .................................................................................................................................................. 58
Fig 2.71 Mounting the Module on the Panel through Mounting Holes (Mounting Plate/Terminal Block) ..100
Fig 2.72 Mounting the Module on the Panel through Mounting Holes with the Terminal Block.....................102
Fig 2.73 Mounting Accura 2550CMS/ZM Modules on the Panel ......................................................................................104
Fig 2.74 Mounting the Modules on the Panel through Mounting Holes (Mounting Wings) ..............................105
Fig 2.75 Mounting the Modules on the Panel through Mounting Holes (Mounting Wings) ..............................105
Fig 2.76 Mounting the Modules on the Panel through Mounting Holes (Mounting Wings) ..............................106
Fig 2.77 Mounting Accura 2550CMM Modules on the Panel .............................................................................................107
Fig 2.78 Mounting Accura 2550CMMZ Modules on the Panel ..........................................................................................108
Fig 2.79 Mounting the Module on the Panel through Mounting Holes........................................................................109
Fig 2.80 Mounting the Accura 2550CMMZ-3P-60A Module on the Panel through Mounting Holes ............109
Fig 2.81 Voltage Wiring of Accura 2500M ....................................................................................................................................110
Fig 2.82 3P4W Connection with 3 PTs ............................................................................................................................................112
Fig 2.83 3P3W Connection with 2 PTs ............................................................................................................................................112
Fig 2.84 1P3W Connection with 2 PTs ............................................................................................................................................113
Fig 2.85 1P2W Connection with 1 PT ..............................................................................................................................................113
Fig 2.86 Accura 2500M Power Supply/Ground Wiring of Accura 2500M-AC220V/DC110V ................................114
Fig 2.87 Accura 2500M Power Supply/Ground Wiring of Accura 2500M-DC24V .....................................................115
Fig 2.88 DISPLAY Port on Accura 2500M ......................................................................................................................................116
Fig 2.89 Accura 2500D Rear .................................................................................................................................................................116
Fig 2.90 Connecting Accura 2500M to Accura 2500D Using the Communication Cable ......................................117
Fig 2.91 3P4W/3P3W Through-Hole Wiring ................................................................................................................................121
Fig 2.92 3P3W Through-Hole Wiring ..............................................................................................................................................121
Fig 2.93 3P4W/3P3W Through-Hole Wiring with 3CTs...........................................................................................................122
Fig 2.94 3P3W Through-Hole Wiring with 2 CTs .......................................................................................................................122
Fig 2.95 3P4W Through-Hole Wiring ..............................................................................................................................................123
Fig 2.96 Single-Phase Line-to-Neutral Through-Hole Wiring (250A)...............................................................................124
Fig 2.97 Single-Phase Line-to-Neutral Through-Hole Wiring ..............................................................................................124
Fig 2.98 Split-Core 3P4W Power/Leakage Current Measuring Module ..........................................................................125
Fig 2.99 Split-Core 1P3F Power/Leakage Current Measuring Module ............................................................................126
Fig 2.100 Split-Core 1P2F Power/Leakage Current Measuring Module ..........................................................................127
Fig 2.101 Three-Phase Power Measuring Module for MCBs................................................................................................128
Fig 2.102 Three-Phase Power/Leakage Current Measuring Module for MCBs ...........................................................128
Fig 2.103 Connecting the Cable for Connection with the ZCT to the External ZCT.................................................129
Fig 2.104 Connecting Accura 2550CM-3P Module with the External ZCT ....................................................................129
Fig 2.105 Connecting Accura 2500M to Accura 2550CM Using Internal Communication Cables ....................131
Fig 2.106 Ethernet Ports on Accura 2500M..................................................................................................................................132
Fig 2.107 Connecting Accura 2500M Modules via Ethernet Communication .............................................................133
Fig 2.108 RS-485 Port on Accura 2500M ......................................................................................................................................134
Fig 2.109 Connecting Accura 2500M Modules via RS-485 Communication................................................................134
Fig 3.1 Device Composition of Accura 2500M............................................................................................................................135
Chapter 1 Introduction
Overview
Voltage, Current, and Power Measurement in AC/DC Industrial Control Panels
Accura 2500M module measures both AC and DC voltage. However, Accura 2550 modules are divided into
the modules that measure AC current and DC current, respectively. Therefore, you should use the Accura
2550 module that suits your needs according to the AC/DC voltage specifications of industrial control panels.
A Variety of Data, including Dip(Sag)/Swell and PQ Curve Available for Power Quality Analysis
Accura 2500/2550 provide a wide variety of data, including Dip, Swell, PQ Curve, harmonics(up to the 50th
order), Crest factor, K-factor, and unbalance for power quality analysis. It allows energy managers to easily
identify changes in power quality in various industrial control panels at power facilities, enabling effective
power quality management.
Accurate Measurements of Voltage, Current, Active Power and Active Energy (IEC 61557-12
Class 0.5)
Recently, it has become essential to establish enterprise-wide energy management systems for efficient
energy usage at sites such as plants, factories, and buildings due to greenhouse gas emission regulations.
A key factor determining reliability of energy management systems is the measurement accuracy of meters.
Accura 2500/2550 meet the requirements of the IEC 61557-12 Class 0.5 standard for voltage/current/active
power/active energy measurement, enabling accurate analysis and diagnosis of various problems in energy
management at power facilities.
Fig 1.1 Accura 2550 Modules Compatible with MCCBs with Various Ratings
Through-Hole Type Current Sensing Structure for Easier and Safer Installation
Accura 2550 modules feature the through-hole type current sensing structure, which does not require
electrical contact with cables(busbars). Therefore, it ensures safety from electrical accidents, as well as easy
installations. TM-CM[Z]-3P/1P terminal blocks allow for easier electrical wiring.
Fig 1.2 Through-Hole Type Current Sensing Structure of Accura 2550 Modules
Product Information
Smart Industrial Control Panel Digital Power Meter/Power & Leakage Current Measuring
Modules
The Smart Industrial Control Panel Digital Power Meter product line consists of Accura 2500D(Industrial
Control Panel HMI Module) installed at the front of the industrial control panel, Accura 2500M(Main Industrial
Control Panel Module) installed inside the industrial control panel or at the rear of Accura 2500D, Accura
2550CM(Power Measuring Module) and Accura 2550CMZ(Power/Leakage Current Measuring Module),
Accura 2550CMS/ZM(Split-core Power/Leakage Current Measuring Module), Accura 2550CMM[Z](Three-
phase Power/Leakage Current Measuring Module for an MCB) installed at incoming/branch lines in the
industrial control panel.
Accura 2500M module receives measurement data from multiple Accura 2550 modules via internal
communication cables and provides the data through Accura 2500D. Accura 2500M can be combined with
Accura 2500D. Thus, users can install it by connecting it to the back of Accura 2500D, or it can be installed
separately in the industrial control panel.
Three-phase power Accura 2550CM-3P -800A -210 Basic current 800 A 1,500 g
measuring module -630A -145 Basic current 630 A 1,000 g
-400A -140 Basic current 400 A 1,000 g
-250A Basic current 250 A 140 g
-125A Basic current 125 A 130 g
-100A Basic current 100 A 115 g
-60A Basic current 60 A 115 g
-5A 1
Basic current 5 A 155 g
Single-phase power Accura 2550CM-1P -250A Basic current 250 A 125 g
measuring module -125A Basic current 125 A 85 g
-100A Basic current 100 A 80 g
-60A Basic current 60 A 80 g
Three-phase power/ Accura 2550CMZ-3P -800A -220 Basic current 800 A 2,500 g
-630A -155 Basic current 630 A 1,500 g
leakage current -400A -155 Basic current 400 A 1,500 g
measuring module 3 -250A Basic current 250 A 300 g
-125A Basic current 125 A 235 g
-100A Basic current 100 A 175 g
-60A Basic current 60 A 175 g
Three-phase 4-wire Accura 2550CMZ-3P4W -250A-145 Basic current 250 A 330 g
power/leakage current
measuring module
Single-phase power/ Accura 2550CMZ-1P -250A Basic current 250 A 270 g
leakage current -125A Basic current 125 A 155 g
measuring module -100A Basic current 100 A 125 g
-60A Basic current 60 A 125 g
Split-core power Accura -3P4W -60A Basic current 60 A 430 g
measuring module 2550CMS -1P3F -60A Basic current 60 A 430 g
-1P2F -60A Basic current 60 A 350 g
Leakage current Accura 2550ZM -3P4W -60A-DI Basic current 60 A 210 g
measuring module -1P3F -60A-DI Basic current 60 A 330 g
-1P2F -60A-DI Basic current 60 A 230 g
Three-phase power Accura -3P -60A Basic current 60 A 100 g
measuring module for 2550CMM
MCBs
Three-phase Accura -3P -60A Basic current 60 A 150 g
power/leakage current 2550CMMZ
measuring module for
MCBs
Three-phase terminal TM-CM-BC-3P 3 -105 Accura 2550CM-3P-250A terminal block 325 g
block
for Accura 2550CM 2 TM-CM-3P -105 Accura 2550CM-3P-250A terminal block 320 g
-90 Accura 2550CM-3P-125A terminal block 195 g
-75L Accura 2550CM-3P-100A terminal block 185 g
-75 Accura 2550CM-3P-60A terminal block 140 g
The abbreviated names of Accura 2500/2550 modules are shown in the table below.
Special-Purpose Modules
The following table shows special-purpose modules with other functions except for the power measuring
function. For details on special-purpose modules, refer to the User Guide for each module.
Installation Example
Combined Installation of Accura 2500D and 2500M
The following figure shows a commonly used example of installing the power measuring module in the
industrial control panel. Accura 2500D is installed at the front of the industrial control panel, and Accura
2500M is installed by being attached to the rear of Accura 2500D.
Installation
Front panel Accura 2500D/2500M Industrial control panel HMI module /
Main industrial control panel module
Incoming line Accura 2550CMZ-3P-800A-220 Three-phase power/leakage current measuring module
Branch line Accura 2550CMZ-3P Three-phase power/leakage current measuring module
Accura 2550CMZ-1P 1 Single-phase power/leakage current measuring module
Internal Internal cable 2 Dedicated communication with the measuring module
communication
External Ethernet cable Ethernet communication with the host system
communication
1. Accura 2550CMZ-1P modules measure leakage current from both line-to-neutral and line-to-line loads.
2. It is provided with the product. Additional cables needed for a ring topology are sold separately. The conducting wire
should be at least 0.205 mm2 (24 AWG). It is recommended to keep a distance of over 5 mm from power lines
generating high levels of noise.
Fig 1.4 Connection of Accura 2500D and 2500M Using Communication Cables
Installation
Front panel Accura 2500D Industrial control panel HMI module
Inside the panel Accura 2500M Main industrial control panel module
Incoming line Accura 2550CMZ-3P-800A-220 Three-phase power/leakage current measuring module
Branch line Accura 2550CMZ-3P Three-phase power/leakage current measuring module
Accura 2550CMZ-1P 1 Single-phase power/leakage current measuring module
Internal Internal cable for the display Communication with the HMI module
communication module 2
Internal cable 3
Communication with the measuring module
External Ethernet cable Ethernet communication with the host system
communication
1. Accura 2550CMZ-1P modules measure leakage current from both line-to-neutral and line-to-line loads
2. It is provided with the product.
3. It is provided with the product. Additional cables needed for a ring topology are sold separately. The conducting wire
of the communication cable should be at least 0.205 mm2 (24 AWG). It is recommended to keep a distance of over
5 mm from power lines generating high levels of noise
Product Features
Installed at the incoming line of the industrial control panel, Accura 2500M module performs the main
function of the industrial control panel. It senses the voltage of the incoming line in the industrial control
panel and sends the sampled voltage data to all Accura 2550 modules connected with internal
communication cables, enabling to measure power at each branch line. Accura 2500M shows measurement
and operational status data collected from multiple Accura 2550 modules through Accura 2500D module’s
TFT LCD screen. Accura 2500M connects with the host system via Ethernet or external RS-485 communication.
Because Accura 2500M module can be combined with Accura 2500D module, it can be installed by being
attached to the back of Accura 2500D. It can also be installed separately in the industrial control panel.
Power Quality
Dip/Swell 1
RMS voltage refreshed every cycle
PQ Curve 1
RMS voltage refreshed every cycle
Supports SEMI F47-0706, IEC 61000-4-11/34 Class 3, and ITIC
Harmonics Harmonics up to the 50th order 1
Sends measurement data collected from multiple Accura 2550 modules to the host system
Power Supply
Power supply AC 100 – 240 V 50/60 Hz, DC 100 – 300 V, CAT II Accura 2500M-AC220V/DC110V 8
Accura 2500D is installed at the front of the industrial control panel. Users can install it either by connecting
with Accura 2500M using a communication cable or by attaching Accura 2500M to the back of the device.
The 5" TFT Color LCD screen on the front of the device provides users with measurement and operational
status data collected from multiple Accura 2550 modules. In addition, all functions of Accura 2500M and
Accura 2550 can be set through the TFT Color LCD screen, which has the touch function.
Accura 2550CM[Z]-3P/CMZ-3P4W modules are installed on the incoming/branch lines in industrial control
panels and sense currents. It measures various power characteristics of individual loads based on the voltage
data of the incoming line received from Accura 2500M module, as well as current data.
Accura 2550CMZ-3P/CMZ-3P4W modules have built-in ZCTs(Zero-sequence Current Transformers) and
directly measure the leakage current of three-phase 3-wire or three-phase 4-wire loads.
-630A-145-ZCT 630 A
-400A-140-ZCT 400 A
-5A-ZCT 1 5A
Accura 2550CMZ-3P -800A-220 800 A Leakage current is measured for three-phase
-630A-155 630A 3-wire loads.
-400A-155 400 A
-250A 250 A
-125A 125 A
-100A 100 A
-60A 60 A
Accura 2550CMZ-3P4W -250A-145 250A Leakage current is measured for three-phase
4-wire loads.
Measurement Parameters
Current RMS, Fundamental, Harmonics, THD, TDD, Vector diagram (phasor), Current waveforms
Symmetrical components, Unbalance according to symmetrical components, Current
unbalance, Crest factor, K-factor
Residual current (RMS, fundamental)
Leakage current Measured by the built-in ZCT Accura 2550CM-3P modules, which can
connect an external ZCT
Accura 2550CMZ modules
Power Active power, Reactive power, Apparent power
Energy Received/Delivered active energy, 4-quadrant reactive energy, Apparent energy
Power factor Power factor, Displacement power factor 3
1. Accura 2550CM-3P-5A module can be used by externally installing CTs (the rated secondary current: 5 A).
2. Accura 2550CM-3P, which can connect an external ZCT, module measures leakage current by connecting an externally
installed voltage-type ZCT to its ZCT connection port. The user must purchase the ZCT separately from the
ZCT manufacturer.
3. The data are available only via communication.
4. The number of modules that can be connected varies by module type. Refer to 「Appendix B Module Connection」
for details about module connection.
Accura 2550CM[Z]-1P modules are installed on the single-phase branch line of the industrial control panel
to sense currents. It measures various power characteristics of individual loads based on the measured
current values and the voltage data on the incoming line received from Accura 2500M module. Accura
2550CMZ-1P modules have built-in ZCTs(Zero-sequence Current Transformers) and directly measure leakage
current in a line-to-line or line-to-neutral configuration for single-phase loads.
-60A 60 A
Accura 2550CMZ-1P -250A 250 A Leakage current is directly measured with
-125A 125 A the built-in ZCT.
-100A 100 A
-60A 60 A
Measurement Parameters
Current RMS, Fundamental, Harmonics, THD, TDD, Vector diagram (phasor), Current waveforms
Crest factor, K-factor
Leakage current Measured by the built-in ZCT Accura 2550CMZ modules
Power Active power, Reactive power, Apparent power
Energy Received/Delivered active energy, 4-quadrant reactive energy, Apparent energy
Power factor Power factor, Displacement power factor 1
Power Supply
Power supply voltage Receives power from Accura 2500M
1. The data are available only via communication.
2. The number of modules that can be connected varies by module type. Refer to 「Appendix B Module Connection」
for details about module connection.
Accura 2550CMS-3P4W modules are installed on branch lines in a three-phase 4-wire configuration in
industrial control panels and sense three-phase currents. Accura 2550CMS-1P3F/1P2F split-core power
measuring modules are installed on consecutive branch lines in a single-phase configuration and sense
single-phase currents in three or two feeders in industrial control panels. The modules measure various
power characteristics based on the sensed current information and incoming voltage information received
from the Accura 2500M Main module.
Accura 2550ZM-3P4W/1P3F/1P2F leakage measuring modules are equipped with Zero-phase Current
Transformers(ZCTs) for individual feeders to measure leakage currents from three-phase or three or two
single-phase loads. They also have digital input terminals to monitor the operation and trip status of the
MCCBs(Molded Case Circuit Breakers) for each feeder. The Accura 2550ZM-3P4W leakage current measuring
module is connected to the Accura 2550CMS-3P4W split-core power measuring module, and the Accura
2550ZM-1P3F leakage current measuring module is connected to the Accura 2550CMS-1P3F split-core power
measuring module using communication cables. Also, the Accura 2550ZM-1P2F leakage current measuring
module is connected to the Accura 2550CMS-1P2F split-core power measuring module.
The Accura 2550CMM-3P module is installed at either the main or branch lines of the industrial control
panel to sense the current. Based on the incoming voltage information received from the Accura 2500M,
it measures various power characteristics of the corresponding load. The Accura 2550CMM-3P module
supports measurements of multiple single-phase feeders. When connecting the module to the load, the hot
line should pass through the main hole(Ø 10.4) of the module, and the Neutral line should pass through
its sub-hole(Ø 5.9). Accura 2550CMMZ-3P module is equipped with a built-in ZCT (Zero-sequence Current
Transformer), allowing it to directly measure the leakage current of three-phase 3-wire or three-phase 4-
wire loads. Additionally, the Accura 2550CMMZ-3P with a built-in ZCT does not support multi-feeder
measurement functionality.
Chapter 2 Installation
Conditions for Installation
Accura 2500/2550 should be installed at the locations that are not affected by high temperatures and high
electric fields. To operate the products properly, you should install it under the environmental conditions as
below.
Caution
The meter should be installed in an industrial control cabinet or similar enclosure to prevent users from
accessing the terminal strips on the meter and to minimize exposure to external environments after
installation. Install the product in a dry location free from dirt, oil and corrosive vapors. When installing
the product, there is no need to clean it.
Before installing Accura 2500/2550, observe the following instructions and safety precautions.
Caution
You should power up the device after voltage and current wiring is completed.
Product Appearance
Fig 2.1 Accura 2500M Front Fig 2.2 Accura 2500M Side
Fig 2.4 Accura 2500D Front Fig 2.5 Accura 2500D Side
A2550CM-3P-800A/630A/400A A2550CM-3P-800A/630A/400A-ZCT
A2550CM-3P-250A/125A/100A/60A/5A A2550CM-3P-5A-ZCT
A2550CM-1P-250A/125A/100A/60A
1. The Accura 2550CM-3P-5A-ZCT module, which allows for external ZCT connections, has the same dimensions as the
Accura 2550CM-3P-5A module but features an additional external ZCT connection terminal on the side.
A2550CMZ-3P4W-250A-145
A2550CMS-3P4W/1P3F/1P2F-60A
A2550CMM-3P-60A
A2550CMMZ-3P-60A
TM-CM[Z]-BC-3P-105 TM-CM[Z]-BC-3P4W-140
Components
Fig 2.18 Accura 2500M Components
3 m x 1 EA, 75 cm x 1 EA
Accura 2500M Mounting 2 bolt caps 4 mounting screws Internal communication cables 1
wings(L/S)
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
3 m x 1 EA
Accura 2500D Mounting wheel Internal cable for the display module
30 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
30 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
10 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
10 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
10 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
10 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
10 cm x 1 EA
125A/100A/60A
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
10 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
20 cm x 1 EA
1. Additional cables for connection with Accura 2550 modules in a ring topology are sold separately.
20 cm x 1 EA
50 cm x 1 EA
Accura 2550ZM-3P4W Mounting plate 2 mounting screws RJ12 Internal Digital input cables
communication cable
20 cm x 1 EA
50 cm x 3 EA
Accura 2550ZM-1P3F Mounting plate 2 mounting screws RJ12 Internal Digital input cables
communication cable
20 cm x 1 EA
50 cm x 2 EA
Accura 2550ZM-1P3F Mounting plate 2 mounting screws RJ12 Internal Digital input cables
communication cable
20 cm x 1 EA
Accura 2550CMM Standard DIN rail mounting 2 mounting RJ12 Internal communication cable
mounting plate plate screws
50 cm x 2 EA
20 cm x 1 EA
Accura 2550CMMZ mounting plate 2 mounting RJ12 Internal communication Digital input cables
screws cable
Dimensions
Product Type Model Dimensions [mm] Weight
W x H x D
Main industrial control panel Accura 2500M 148.6 x 126.8 x 60.8 500 g
module
Industrial control panel HMI Accura 2500D 151.5 x 129.6 x 32.6 400 g
module
Three-phase power Accura 2550CM-3P -800A-210 45.0 x 210.0 x 93.7 1,500 g
measuring module -800A-210-ZCT 45.0 x 210.0 x 93.7 1,500 g
-630A-145 45.0 x 145.0 x 93.7 1,000 g
-630A-145-ZCT 45.0 x 145.0 x 93.7 1,000 g
-400A-140 45.0 x 140.0 x 93.7 1,000 g
-400A-140-ZCT 45.0 x 140.0 x 93.7 1,000 g
-250A 25.0 x 105.0 x 61.7 140 g
-125A 25.0 x 90.0 x 61.7 130 g
-100A 25.0 x 75.0 x 61.7 115 g
-60A 25.0 x 75.0 x 61.7 115 g
-5A 1 25.0 x 75.0 x 61.7 155 g
-5A-ZCT 1 25.0 x 75.0 x 61.7 155 g
Single-phase power Accura 2550CM-1P -250A 25.0 x 105.0 x 61.7 125 g
measuring module -125A 25.0 x 60.0 x 61.7 85 g
-100A 25.0 x 50.0 x 61.7 80 g
-60A 25.0 x 50.0 x 61.7 80 g
Three-phase Accura 2550CMZ-3P -800A-220 80.0 x 219.6 x 94.2 2,500 g
power/leakage current -630A-155 80.0 x 154.6 x 94.2 1,500 g
measuring module -400A-155 80.0 x 154.6 x 94.2 1,500 g
-250A 45.0 x 105.0 x 61.7 300 g
-125A 40.0 x 90.0 x 61.7 235 g
-100A 35.0 x 75.0 x 61.7 175 g
-60A 35.0 x 75.0 x 61.7 175 g
Accura 2550CMZ-3P4W -250A-145 45.0 x 140.0 x 61.7 330 g
Single-phase power/leakage Accura 2550CMZ-1P -250A 45.0 x 105.0 x 61.7 270 g
current measuring module -125A 35.0 x 60.0 x 61.7 155 g
-100A 35.0 x 50.0 x 61.7 125 g
-60A 35.0 x 50.0 x 61.7 125 g
Split-core Accura 2550CMS -3P4W -60A 53.0 x 100.0 x 85.0 430 g
power measuring module -1P3F -60A 53.0 x 100.0 x 85.0 430 g
-1P2F -60A 53.0 x 100.0 x 85.0 430 g
Leakage current Accura 2550ZM -3P4W -60A-DI 49.9 x 100.0 x 79.9 210 g
measuring module -1P3F -60A-DI 49.9 x 150.0 x 64.9 330 g
-1P2F -60A-DI 49.9 x 100.0 x 64.9 230 g
Three-phase power Accura 2550CMM -3P -60A 25.0 x 52.5 x 54.3 100 g
measuring module for MCBs
Three-phase power/leakage Accura 2550CMMZ -3P -60A 25.0 x 57.0 x 83.9 150 g
current measuring module for
MCBs
Three-phase terminal block for TM-CM-BC-3P -105 68.8 x 105.0 x 54.0 325 g
CM modules TM-CM-3P -105 68.8 x 105.0 x 54.0 320 g
(The weight includes the cover -90 62.8 x 90.0 x 54.0 195 g
for the terminal block.) -75L 62.5 x 75.0 x 54.0 185 g
-75 57.2 x 75.0 x 54.0 140 g
Single-phase terminal block TM-CM-1P -105 68.8 x 105.0 x 54.0 240 g
for CM modules -60 62.8 x 60.0 x 54.0 135 g
(The weight includes the cover -50L 62.5 x 50.0 x 54.0 125 g
for the terminal block.) -50 57.2 x 50.0 x 54.0 90 g
Three-phase terminal block for TM-CMZ-BC-3P -105 88.8 x 105.0 x 54.0 390 g
CMZ modules TM-CMZ-3P -105 88.8 x 105.0 x 54.0 385 g
(The weight includes the cover -90 77.8 x 90.0 x 54.0 220 g
for the terminal block.) -75L 72.5 x 75.0 x 54.0 200 g
-75 67.2 x 75.0 x 54.0 150 g
Three-phase 4-wire TM-CMZ-BC-3P4W 2, 3
-140 88.8 x 140.0 x 54.0 510 g
terminal block for CMZ
modules
Single-phase terminal block TM-CMZ-1P -105 88.8 x 105.0 x 54.0 310 g
for CMZ modules -60 72.8 x 60.0 x 54.0 145 g
(The weight includes the cover -50L 72.5 x 50.0 x 54.0 135 g
for the terminal block.) -50 67.2 x 50.0 x 54.0 100 g
1. Accura 2550CM-3P-5A module can be used by externally installing CTs (the secondary current rating: 5 A).
2. The weight of the terminal block includes its cover.
3. The 250A terminal block allows for the insertion of barriers.
Accura 2500D/2500M
Front Rear
Accura 2550CM-3P
Accura 2550CM-3P-5A-ZCT
Accura 2550CM-1P
Accura 2550CM-1P-250A 1
Accura 2550CM-1P-125A
Accura 2550CM-1P-100A/60A
1. The hole in the middle of the module is not used when passing cables through the holes of the module.
Accura 2550CMZ-3P
Accura 2550CMZ-3P4W
Accura 2550CMZ-3P4W-250A-145
Accura 2550CMZ-1P
Accura 2550CMZ-1P-250A 1
Accura 2550CMZ-1P-125A
Accura 2550CMZ-1P-100A/60A
1. The hole in the middle of the module is not used when passing cables through the holes of the module.
Accura 2550CMS
Accura 2550CMS-3P4W/1P3F/1P2F-60A
Accura 2550ZM
Accura 2550ZM-1P2F-60A-DI
Accura 2550CMM
Accua 2550CMMZ
Accura 2550CMMZ-3P-60A
TM-CM-3P
TM-CM-BC-3P-105 1
TM-CM-BC-3P-105 Cover
TM-CM-1P
TM-CMZ-3P
TM-CMZ-3P4W
TM-CMZ-1P
Installation Example
Installation of Accura 2500M/2500D/2550 Power Measuring Modules
The following figure shows an example of the installation method frequently used in industrial control panels.
Installation
Front panel Accura Main industrial control panel
2500M/2500D /HMI module
Incoming line Accura 2550CMZ- Three-phase power/leakage
3P-800A-220 current measuring module
Branch line Accura 2550CMZ-3P Three-phase power/leakage
current measuring module
Accura 2550CMZ-1P Single-phase power/leakage
current measuring module
Auxiliary device TM-CMZ-3P 3-phase terminal block
TM-CMZ-1P 1-phase terminal block
Internal Internal cable 1 Communication with power
communication measuring modules
1. Accura 2550CMZ-1P modules measure leakage current from both line-to-neutral and line-to-line loads.
2.It is provided with the product. Additional cables needed for a ring topology are sold separately. Its conducting wire
should be at least 0.205 mm2(24 AWG). It is recommended to keep a distance of over 5 mm from the power lines
generating high levels of noise.
The following figure shows an example of installing Accura 2550CMM[Z]-3P modules with MCBs(Miniature
Circuit Breakers) in an industrial control panel at a data center.
Step 1: Installation
Accura 2500D module is installed at the front of the industrial control panel.
① Fit the module into the panel cutout.
② Cover the back of the module with the mounting wheel.
③ Fix the module onto the panel by turning the mounting wheel.
① Place the mounting plate on the location where you want to install the device.
② Tighten screws on the mounting plate diagonally.
③ Attach Accura 2550CM[Z]-3P module to the mounting plate.
④ Connect the three-phase terminal block with Accura 2550CM[Z]-3P module.
⑤ Fix the three-phase terminal block.
⑥ Connect the busbar with the MCCB.
⑦ Attach the cover to the three-phase terminal block.
Accura 2550CM[Z]-3P modules with the basic current ≥ 400 A can be fixed to the panel using mounting
wings instead of the mounting plate.
A tolerance of 0.5 mm
between devices is required.
Fig 2.62 Mounting Accura 2550CM-3P Module on the Panel through Mounting Holes (Mounting Wings) /
clear distance exists
Applied Model
Accura 2550CM-3P-800A-210
Applied Model
Accura 2550CM-3P-630A-145
Applied Model
Accura 2550CM-3P-400A-140
Fig 2.63 Mounting Accura 2550CM-3P Module on the Panel through Mounting Holes (Mounting Wings) /
without clear distance
Applied Model
Accura 2550CM-3P-800A-210
Applied Model
Accura 2550CM-3P-630A-145
Applied Model
Accura 2550CM-3P-400A-140
Fig 2.64 Mounting the Module on the Panel through Mounting Holes (Mounting Plate/Terminal Block)
Applied Model
Accura 2550CM-3P-250A
TM-CM-3P-105
Applied Model
Accura 2550CM-3P-125A
TM-CM-3P-90
Applied Model
Accura 2550CM-3P-100A
TM-CM-3P-75L
Applied Model
Accura 2550CM-3P-60A
TM-CM-3P-75
Fig 2.65 Mounting the Module on the Panel through Mounting Holes (Mounting Wings) / clear distance
exists
Applied Model
Accura 2550CMZ-3P-800A-220
Applied Model
Accura 2550CMZ-3P-630A-155
Applied Model
Accura 2550CMZ-3P-400A-155
Fig 2.66 Mounting the Module on the Panel through Mounting Holes (Mounting Wings) / without clear
distance
Applied Model
Accura 2550CMZ-3P-800A-220
Applied Model
Accura 2550CMZ-3P-630A-155
Applied Model
Accura 2550CMZ-3P-400A-155
Fig 2.67 Mounting the Module on the Panel through Mounting Holes (Mounting Plate/Terminal Block)
Applied Model
Accura 2550CMZ-3P-250A
TM-CMZ-3P-105
Applied Model
Accura 2550CMZ-3P-125A
TM-CMZ-3P-90
Applied Model
Accura 2550CMZ-3P-100A
TM-CMZ-3P-75L
Applied Model
Accura 2550CMZ-3P-60A
TM-CMZ-3P-75
① Place the mounting plate on the location where you want to install the device.
② Tighten screws on the mounting plate diagonally.
③ Attach Accura 2550CMZ-3P4W module to the mounting plate.
④ Connect the three-phase 4-wire terminal block with Accura 2550CMZ-3P4W module.
⑤ Fix the three-phase 4-wire terminal block.
⑥ Connect the busbar with the MCCB.
⑦ Attach the cover to the three-phase terminal block.
Fig 2.69 Mounting the Module on the Panel through Mounting Holes
Applied Model
Accura 2550CMZ-3P4W-250A-145
TM-CMZ-BC-3P4W-140
① Place the mounting plate on the location where you want to install the device.
② Tighten screws on the mounting plate diagonally.
③ Attach Accura 2550CM[Z]-1P module to the mounting plate .
④ Connect the single-phase terminal block with Accura 2550CM[Z]-1P module.
⑤ Fix the single-phase terminal block.
⑥ Connect the busbar with the MCCB.
⑦ Attach the cover to the terminal block.
A tolerance of 0.5 mm
between devices is required.
Fig 2.71 Mounting the Module on the Panel through Mounting Holes (Mounting Plate/Terminal Block)
Applied Model
Accura 2550CM-1P-250A
TM-CM-1P-105
Applied Model
Accura 2550CM-1P-125A
TM-CM-1P-60
Applied Model
Accura 2550CM-1P-100A
TM-CM-1P-50L
Applied Model
Accura 2550CM-1P-60A
TM-CM-1P-50
Fig 2.72 Mounting the Module on the Panel through Mounting Holes with the Terminal Block
Applied Model
Accura 2550CMZ-1P-250A
TM-CMZ-1P-105
Applied Model
Accura 2550CMZ-1P-125A
TM-CMZ-1P-60
Applied Model
Accura 2550CMZ-1P-100A
TM-CMZ-1P-50L
Applied Model
Accura 2550CMZ-1P-60A
TM-CMZ-1P-50
① Place the Accura 2550ZM’s mounting wings on the location where you want to install the device.
② Tighten screws on the mounting plate diagonally.
③ Place the Accura 2550CMS’s mounting wings on the location where you want to install the device.
④ Tighten screws on the mounting plate diagonally, and then connect Accura 2550CMS modules to
Accura 2550ZM modules using communication cables.
⑤ Connect the Accura 2550CMS and Accura 2550ZM using a communication cable.
Fig 2.74 Mounting the Modules on the Panel through Mounting Holes (Mounting Wings)
Applied Model
Accura 2550CMS-3P4W-60A
Accura 2550ZM-3P4W-60A-DI
* A clearance of 30 mm is
required for cable installation.
Fig 2.75 Mounting the Modules on the Panel through Mounting Holes (Mounting Wings)
Applied Model
Accura 2550CMS-1P3F-60A
Accura 2550ZM-1P3F-60A-DI
* A clearance of 30 mm is
required for cable installation.
Fig 2.76 Mounting the Modules on the Panel through Mounting Holes (Mounting Wings)
Applied Model
Accura 2550CMS-1P2F-60A
Accura 2550ZM-1P2F-60A-DI
* A clearance of 30 mm is
required for cable installation.
Fig 2.79 Mounting the Module on the Panel through Mounting Holes
Applied Model
Accura 2550CMM-3P-60A
Fig 2.80 Mounting the Accura 2550CMMZ-3P-60A Module on the Panel through Mounting Holes
Applied Model
Accura 2550CMMZ-3P-60A
* A clearance of 30 mm is
required for cable installation.
Voltage Input
Item Description
Port name V1, V2, V3, VN
Connector type Terminal block 1 (M4/bolt head Ø7)
Wire specification 0.75 – 6.0 mm2 (18 – 10 AWG), copper
Wire temperature rating Above 70 ˚C
Measuring range (accuracy guaranteed)
2 AC 35 – 347 V L-N (Line-to-neutral)
AC 60 – 600 V L-L (for unearthed Delta & Y systems)
Measurement accuracy IEC 61557-12 Class 0.5 ±0.5 % Reading
Minimum measured value 5 V Line-to-neutral
Frequency range 42 – 65 Hz
Voltage wiring method 3P4W, 3P3W, 1P3W, 1P2W
Burden 0.01 VA/phase @ 220 V
Withstand voltage AC 3,000 V RMS, 60 Hz for 1 minute
Impedance 10 MΩ/phase
Measurement category Category Ⅲ
1. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.8 Nm(18.4 kgf-cm, 16 lbf-in).
2. It indicates the input voltage range of the device. Thus, when a PT is used externally, primary voltage is calculated by
multiplying it by the PT ratio.
Note
If the voltage input gets out of the measurement range, it can affect accuracy. External PTs(Potential
Transformer) should be used when measuring voltages greater than voltage input specifications.
Caution
When installing fuses on the power line, it is recommended to use fuses that are UL-listed with an RK5
class or higher and are rated at 2 A/500 V. In case of using external PTs, a fuse should be installed at the
PT secondary.
Wiring Considerations
Caution
Failure to observe the following instructions may result in severe injury or death.
◼ During normal operation of Accura 2500, hazardous voltages are present on its terminal strips that
connect the PT(Potential Transformer), voltage input, power, and external I/O circuits. The secondary of
the PT may generate fatal voltages/currents resulting from the primary of the PT.
◼ Standard safety precautions should be followed while installing or maintaining the product, including
removing PT fuses.
◼ Install the product in a panelboard to prevent users from accessing terminal strips after completing
wiring of the product.
Caution
Observe the following instructions, or permanent damage may occur to the product.
◼ Do not apply voltages and currents that exceed the input ratings of the PT to the product.
◼ Using the device for purposes not specified by the manufacturer can cause severe damage to the
product.
◼ Connect the ground terminal to the earth ground to protect the device from noise and surge. Failure
to properly connect the chassis ground will void the warranty of the product.
3P4W Connection
Set the voltage wiring mode to 3P4W. If the voltage value is within the measuring range, it allows for direct
wiring without the need for a PT.
3P3W Connection
Set the voltage wiring mode to 3P3W. If the voltage value is within the measuring range, it allows for direct
wiring without the need for a PT.
1P3W Connection
Set the voltage wiring mode to 1P3W. The L1 and L2 line voltages should be connected to the V1 and V3
ports, and the N line should be connected to the VN port. If the voltage value is within the measuring range,
it allows for direct wiring without the need for a PT.
Fig 2.84 1P3W Connection with 2 PTs
1P2W Connection
Set the voltage wiring mode to 1P2W. The L1 line voltage should be connected to the V1 port, and the N
line should be connected to the VN port. If the voltage value is within the measuring range, it allows for
direct wiring without the need for a PT.
Fig 2.85 1P2W Connection with 1 PT
Item Description
Port name L+, N-, (Ground)
Connector type Terminal block 1 (M3.5/bolt head Ø6)
Wire specification 0.34 – 4.0 mm2 (22 – 12 AWG), copper
Wire temperature rating Above 70 ˚C
Power supply voltage (Us) 2
AC 100 – 240 V 50/60 Hz, DC 100 – 300 V, CAT II
Operating voltage range 0.9 x Us – 1.1 x Us
Power consumption 3
Maximum 20 W
Inrush current 4 Peak 31 A, duration : no more than 1 msec (AC 220 V)
Peak 11 A, duration : no more than 0.2 msec (DC 110 V)
1. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.4 Nm(14 kgf-cm, 12 lbf-in).
2. The device conforms to UL standards for the tested AC power supply voltage.
3. It refers to the maximum power consumption based on the power supply input voltage when Accura 2500D is
connected with Accura 2550 modules.
4. When installing fuses on the power line, it is recommended to use fuses that are UL-listed with an RK5 class or
higher and are rated at 2 A/500 V.
Note
The ground terminal of Accura 2500M is connected to the earth ground of the panel.
Item Description
Port name L+, N-, (Ground)
Connector type Terminal block 1 (M4.0/bolt head Ø7)
Wire specification 0.75 – 6.0 mm2 (18 – 10 AWG), copper
Wire temperature rating Above 70 ˚C
Power supply voltage (Us) DC 24 V, CAT II
Operating voltage range DC 20 – 30 V
Power consumption 2 Maximum 20 W
Inrush current 3
Peak 6 A, duration : no more than 1 msec (DC 24 V)
1. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.2 Nm(12 kgf-cm, 10.6 lbf-in).
2. It refers to the maximum power consumption based on the power supply input voltage when Accura 2500D is
connected with Accura 2550 modules.
3. When installing fuses on the power line, it is recommended to use fuses that are UL-listed with an RK5 class or
higher and are rated at 2 A/500 V.
Note
The ground terminal of Accura 2500M is connected to the earth ground of the panel.
Item Description
Port name Accura 2500M DISPLAY
Accura 2500D DISPLAY
Communication cable Internal communication cable for the display module 1 (Cat 5e 24 AWG FTP)
Protocol Internal protocol
Communication cable length Up to 3 m
Power supply Supplies power via the communication cable
1. It is provided with the product.
Fig 2.90 Connecting Accura 2500M to Accura 2500D Using the Communication Cable
MCBs
Accura -3P -60A Ø 10.5 150
2550CMMZ
1. Accura 2550CM-3P-5A module can be used by externally installing CTs (the secondary current rating: 5 A).
2. The split-core module refers to the split-core CMS module whose core part is separated vertically.
3. The split-core CMS module has been calibrated under the condition where the power line passes through the top
center position of its hole. As the location of the power line is away from the top center position of the hole, errors in
current, power, and energy measurements can increase by up to 1 %.
4. Install the module by passing the Hot line through its main hole(Ø 10.4) and passing the Neutral line through its
subhole(Ø 5.9).
5. It is only supported in Accura 2550CM-3P module, which can connect to an external ZCT. And It indicates the
measurement accuracy when the measurement error of an external ZCT is zero.
Caution
It is recommended you should use CTT terminal blocks in order to prevent accidents caused by current
transformers and identify device failures in advance. If current is flowing in the primary winding of a CT,
opening the CT secondary can cause serious accidents resulting from high voltages.
Accura 2550CM[Z]-3P
The phase sequence in which the current passes through the cable can be set to A-B-C or C-B-A, and the
direction of current flow to the load can be set to ▶ or ◀.
Applied Model
Three-phase power measuring module
Accura 2550CM-3P-800A-210
Accura 2550CM-3P-800A-210-ZCT
Accura 2550CM-3P-630A-145
Accura 2550CM-3P-630A-145-ZCT
Accura 2550CM-3P-400A-140
Accura 2550CM-3P-400A-140-ZCT
Accura 2550CM-3P-250A
Accura 2550CM-3P-125A
Accura 2550CM-3P-100A
Accura 2550CM-3P-60A
Applied Model
Three-phase power/leakage current measuring module
Accura 2550CMZ-3P-800A-220
Accura 2550CMZ-3P-630A-155
Accura 2550CMZ-3P-400A-155
Accura 2550CMZ-3P-250A
Accura 2550CMZ-3P-125A
Accura 2550CMZ-3P-100A
Accura 2550CMZ-3P-60A
Applied Module
Three-phase power measuring module
Accura 2550CM-3P-5A 1
Accura 2550CM-3P-5A-ZCT 1, 2
1. Accura 2550CM-3P-5A module can be used by externally installing CTs (the secondary current rating: 5 A).
2. Accura 2550CM-3P, which can connect an external ZCT, module measures leakage current by connecting an
externally installed voltage-type ZCT to its ZCT connection port. The user must purchase the ZCT separately from
the ZCT manufacturer.
Applied Model
Three-phase power measuring module
Accura 2550CM-3P-5A 1
Accura 2550CM-3P-5A-ZCT 1, 2
1. Accura 2550CM-3P-5A module can be used by externally installing CTs (the secondary current rating: 5 A).
2. Accura 2550CM-3P, which can connect an external ZCT, module measures leakage current by connecting an externally
installed voltage-type ZCT to its ZCT connection port. The user must purchase the ZCT separately from the ZCT
manufacturer.
Accura 2550CMZ-3P4W
The phase sequence in which the current passes through the cable can be set to A-B-C or C-B-A (The N line
should pass through the fourth hole of the module), and the direction of current flow to the load can be set
to ▶ or ◀.
Applied Model
Three-phase 4-wire power/leakage current
measuring module
Accura 2550CMZ-3P4W-250A-145
Caution
When wiring the CMZ-3P4W module through its holes, the N line should pass through the fourth hole at
the bottom of the module.
Accura 2550CM[Z]-1P
When wiring the module, the cable should pass through the first hole of the module because the hole has
the built-in current sensor. The phase sequence in which the current passes through the cable can be selected
among AN / BN / CN / AB / BC / CA. The direction of current flow to the load can be set to ▶ or ◀.
Applied Model
Single-phase power measuring module
Accura 2550CM[Z]-1P-250A
(The cable does not pass through the hole located
in the middle of the device.)
Applied Model
Single-phase power/leakage current
measuring module
Accura 2550CM[Z]-1P-125A
Accura 2550CM[Z]-1P-100A
Accura 2550CM[Z]-1P-60A
Accura 2550CMS/ZM-3P4W
The split-core CMS-3P4W module senses three-phase current to measure the power of three-phase 4-wire
feeders. The ZM-3P4W module connected to the CMS-3P4W module via communication cables measures
the leakage current of three-phase 4-wire feeders using its built-in ZCT. It is also equipped with digital input
terminals for receiving data on the On/Off/trip status of the MCCB.
The phase sequence in which the current passes through the cable can be set to A-B-C or C-B-A(The N line
should pass through the fourth hole of the module), and the direction of current flow to the load can be set
to ▶ or ◀.
Applied Model
Split-core 3P4W power/leakage current
measuring module
Accura 2550CMS-3P4W-60A
Accura 2550ZM-3P4W-60A-DI
Caution
When wiring the CMS-3P4W module through its holes, the N line should pass through the fourth hole
at the bottom of the module.
Accura 2550CMS/ZM-1P3F
The split-core CMS-1P3F module senses the current of three single-phase feeders and measures the power
of each of the three feeders separately. The ZM-1P3F module connected to the CMS-1P3F module via
communication cables measures the leakage current of three single-phase feeders individually using its three
built-in ZCTs. It is also equipped with digital input terminals for each feeder for receiving data on the
On/Off/trip status of each MCCB.
The phase sequence in which the current passes through the cable can be set to AN / BN / CN / AB / BC /
CA, and the direction of current flow to the load can be set to ▶ or ◀.
Applied Model
Split-core 1P3F power/leakage current
measuring module
Accura 2550CMS-1P3F-60A
Accura 2550ZM-1P3F-60A-DI
Accura 2550CMS/ZM-1P2F
The split-core CMS-1P2F module senses the current of two single-phase feeders and measures the power
of each of the two feeders separately. The ZM-1P2F module connected to the CMS-1P2F module via
communication cables measures the leakage current of the two single-phase feeders individually using its
two built-in ZCTs. It is also equipped with digital input terminals for each feeder for receiving data on the
On/Off/trip status of each MCCB.
The phase sequence in which the current passes through the cable can be set to AN / BN / CN / AB / BC /
CA, and the direction of current flow to the load can be set to ▶ or ◀.
Applied Model
Split-core 1P2F power/leakage current
measuring module
Accura 2550CMS-1P2F-60A
Accura 2550ZM-1P2F-60A-DI
Accura 2550CMM-3P-60A
The phase sequence in which the current passes through the cable can be set to A-B-C or C-B-A, and the
direction of current flow to the load can be set to ▶ or ◀.
Applied Model
Three-phase power measuring module
for MCBs
Accura 2550CMM-3P-60A
Accura 2550CMMZ-3P-60A
The phase sequence in which the current passes through the cable can be set to A-B-C or C-B-A, and the
direction of current flow to the load can be set to ▶ or ◀.
Applied Model
Three-phase power/leakage current
measuring module for MCBs
Accura 2550CMMZ-3P-60A
Item Description
Leakage current input External voltage-output ZCT 200 mA/100 mV @1.2 kΩ burden
Measurement accuracy /range
1 ±2 % Reading + 2 mA Up to 2 A
1. It is the accuracy when the measurement error of the external ZCT is zero.
Fig 2.103 Connecting the Cable for Connection with the ZCT to the External ZCT
Fig 2.104 Connecting Accura 2550CM-3P Module with the External ZCT
Accura 2550
Note
Check connectivity of modules in advance by referring to 「Appendix B Module Connection」 due to
limitations in the length of the communication cable and the number of connectable modules according
to the power consumption of modules.
Fig 2.105 Connecting Accura 2500M to Accura 2550CM Using Internal Communication Cables
in a group
Number of connectable modules Maximum 40
in two groups
Cable length in each group Total length: up to 50 m
(Each cable: up to 10 m)
Installation
Front panel Accura 2500M Industrial control panel digital
power meter
Incoming line Accura 2550CM-3P-5A Three-phase power measuring
module Ring topology
Branch line Accura 2550CM-3P Three-phase power measuring
module
Accura 2550CM-1P Single-phase power measuring
module
Internal Internal cable Internal communication cable 2
communication
1. The number of modules that can be connected varies by module type. Refer to 「Appendix B Module Connection」
for details on module connection.
2. It is provided with the product. Additional cables needed for a ring topology are sold separately. The conducting wire
of the communication cable should be at least 0.205 mm2 (24 AWG). It is recommended to keep a distance of
over 5 mm from power lines generating high levels of noise.
1. It varies by module type. Refer to 「Appendix B Module Connection」 for details on module connection.
2. The RJ45A and RJ45B ports have the same function.
Ethernet Communication
Accura 2500M supports communication with the host system using Ethernet cables for high-speed
transmission of large-capacity measurement data received from multiple Accura 2550 modules. The built-in
Ethernet switch of Accura 2500M enables Ethernet connectivity between Accura 2500M modules using two
Ethernet ports, without the need for a separate external switch. Up to 20 Accura 2500M modules can be
connected in star, daisy chain, and ring topologies. It supports Modbus TCP, the standard protocol for
transmission of measurement data.
Since Accura 2500M supports RSTP(Rapid Spanning Tree Protocol), devices can be connected in a ring
topology. Thus, even if one end of the line is disconnected in a ring topology, communication can be
resumed in the other end of the line within a short period of time, minimizing data loss.
Note
When wiring devices in a ring topology, use the Ethernet switch supporting the RSTP(Rapid Spanning Tree
Protocol) for quick recovery from communication failures, and the switch should be used as the main route
for communication.
Note
Accura 2500 provides a lower bridge priority value of 49152(C000h) instead of a default bridge priority
value of 32768(8000h). If the bridge priority value of a switch is configured as 32768(8000h), the switch
has a higher priority over Accura 2500.
Caution
At sites where industrial control panels are installed, a large number of electromagnetic waves are emitted
due to multiple power cables. This can have a serious impact on Ethernet communication quality.
Therefore, you should use shielded cables.
RS-485 Communication
Device Composition
Fig 3.1 Device Composition of Accura 2500M
Power Supply
Accura 2500M uses power supply generated by receiving AC or DC power. It supplies power to Accura
2500D using the built-in connector or communication cable.
Item Description
Port name L+, N-, (Ground)
Connector type Terminal block 1 (M3.5/bolt head Ø6)
Wire specification 0.34 – 4.0 mm2 (22 – 12 AWG), copper
Wire temperature rating Above 70 ˚C
Power supply voltage (Us) 2
AC 100 – 240 V 50/60 Hz, DC 100 – 300 V, CAT II
Operating voltage range 0.9 x Us – 1.1 x Us
Power consumption 3 Maximum 20 W
Inrush current 4 Peak 31 A, duration : no more than 1 msec (AC 220 V)
Peak 11 A, duration : no more than 200 μsec (DC 110 V)
1. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.4 Nm (14 kgf-cm, 12 lbf-in).
2. The device conforms to UL standards for the tested AC power supply voltage.
3. It refers to the maximum power consumption based on the power supply input voltage when Accura 2500D is
connected with Accura 2550 modules.
4. When installing fuses on the power line, it is recommended to use fuses that are UL-listed with an RK5 class or
higher and are rated at 2 A/500 V.
Item Description
Port name L+, N-, (Ground)
Connector type Terminal block 1 (M4.0/bolt head Ø7)
Wire specification 0.75 – 6.0 mm2 (18 – 10 AWG), copper
Wire temperature rating Above 70 ˚C
Power supply voltage (Us) DC 24 V, CAT II
Operating voltage range DC 20 – 30 V
Power consumption 2
Maximum 20 W
Inrush current 3 Peak 6 A, duration : no more than 1 msec (DC 24 V)
1. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.2 Nm (12 kgf-cm, 10.6 lbf-in).
2. It refers to the maximum power consumption based on the power supply input voltage when Accura 2500D is
connected with Accura 2550 modules.
3. When installing fuses on the power line, it is recommended to use fuses that are UL-listed with an RK5 class or
higher and are rated at 2 A/500 V.
Item Description
Port name V1, V2, V3, VN
Connector type Terminal block 1 (M4/bolt head Ø7)
Wire specification 0.75 – 6.0 mm2 (18 – 10 AWG), copper
Wire temperature rating Above 70 ˚C
Withstand voltage AC 3,000 V RMS, 60 Hz for 1 minute
Impedance 10 MΩ (V1 / V2 / V3 / VN)
Burden 0.01 VA/phase @220 V
Measurement category Category III
Accura 2500M has built-in Ethernet switches, and it enables a daisy-chain connection between Accura 2500M
modules with two Ethernet ports. It eliminates the need for an additional external switch. Ethernet connection
can be made through star, daisy-chain, ring topologies. Up to 20 Accura 2500M modules can be connected
in a daisy chain.
It supports Modbus TCP as the standard communication protocol for data transfer. The ETHERNET1 and
ETHERNET2 ports have the same function. It allows for the redundant device configuration of the host
system by connecting two host systems at the same time.
Item Description
Port name ETHERNET1, ETHERNET2
Connector type RJ45 connector
Communication cable Ethernet cable Cat 5e FTP, STP, SFTP 1
Fig 3.6 Connecting Accura 2500M Modules with Ethernet Cables for External Communication
(Daisy-Chain & Ring Topology)
Daisy-chain &
Ring topology (RSTP protocol)
Item Description
Port name Ta(TRX+), Tb(TRX-)
Connector type Terminal block 1 (M3.5/bolt head Ø6) Accura 2500M-AC220V/DC110V
connectable modules
1. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.4 Nm(14 kgf-cm, 12 lbf-in).
2. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.2 Nm(12 kgf-cm, 10.6 lbf-in).
3. At 115,200 bps, a master can communicate with up to 16 slave devices, and the maximum distance between
the master and the slave is 600 m.
Fig 3.8 Connecting Accura 2500M Modules with RS-485 Cables for External Communication
Accura 2500M allows users to perform setup for Accura 2550 modules on Accura 2500D via internal
communication. Measured values of each module are shown on the screen of Accura 2500D module. It also
supplies power to Accura 2500D using the built-in connector or internal cable for the display module.
Fig 3.10 Connecting Accura 2500M to Accura 2500D Using the Communication Cable
Item Description
Port name DISPLAY
Connector type RJ45 connector
Communication cable Internal cable for the display module 1 (Cat 5e 24 AWG FTP)
Protocol Internal protocol
Communication cable length Up to 3 m
Power supply Supplies power to Accura 2500D module using the communication cable
1. It is provided with the product.
Accura 2500M is connected to Accura 2550 modules using two groups of RJ-45 ports (Group 1: RJ45-1/RJ45-
2, Group 2: RJ45-3/RJ45-4). Devices can be connected in a ring topology using two ports in a group, which
have the same functions. The ring topology supports communication redundancy and therefore increases
reliability of communication.
Up to 30 Accura 2550 modules can be connected in a single group. The number of modules that can be
connected varies by module type since the power consumption of each module is different. If modules
cannot be connected in a single group, they should be connected using ports in two groups.
Note
Check connectivity of modules in advance by referring to 「Appendix B Module Connection」 due to
limitations in the length of the communication cable and the number of connectable modules according
to the power consumption of modules.
Fig 3.11 Connection Example of Accura 2500 and Accura 2550 Modules
Ring Topology
(Communication Redundancy)
Item Description
Port name Group 1: RJ45-1/RJ45-2, Group 2: RJ45-3/RJ45-4
(communication redundancy supported via a ring topology)
Connector type RJ45 connector
Protocol Internal protocol
Communication cable Internal communication cable 1
The following table shows the three LED functions indicating the operational status of the main industrial
control panel module.
Functions
Accura 2500M supports two Ethernet ports and one RS-485 port for external communication with the host
system.
Measurements
Accura 2500M monitors voltage dip(sag)/swells by sensing the voltage of the incoming line in the industrial
control panel. It enables power measurement of each branch line by sending the sampled voltage data to
all Accura 2550 modules connected with the internal communication cable.
Voltage sensing supports 3P3W, 3P4W, 1P3W, and 1P2W connections. When measuring voltage greater than
the measuring range, an external PT should be used for voltage wiring. For details regarding voltage
measurement, refer to 「Chapter 6 Functions> Measurement > Voltage Wiring」.
Measurement Description
Parameters
Voltage wiring method 3P4W, 3P3W, 1P2W, 1P3W
Frequency 50/60 Hz
Sampling rate 512 samples/cycle
Measurement cycle Basic measurement Frame: 0.2 sec (12 cycles @60 Hz, 10 cycles @50 Hz)
(gapless) Dip/Swell measurement 1 1 cycle
PQ Curve measurement 1
Voltage Measuring range AC 35 – 347 V L-N (Line-to-neutral)
Power Quality
Accura 2500M monitors Dip(Sag)/Swell voltages by sensing the voltage of the incoming line in industrial
control panels. It also supports power quality standards, including SEMI F47-0706, IEC 61000-4-11/34 Class
3, and ITIC Curve for power quality evaluation of voltages. For details regarding the PQ(Power Quality) curve,
refer to 「Chapter 6 Functions> Measurements > Power Quality Events」.
Item Description
Dip/Swell 1 Measured values / RMS voltage (refreshed every cycle) Threshold set by users
Threshold
PQ Curve 1 Measured values / RMS voltage (refreshed every cycle) Dip/swell threshold: 90 % /
Threshold 110 % of Vref
Curve type SEMI F47-0706, IEC 61000-4-11/34 Class 3, ITIC
Transient voltage Measured values / Differences between sampled voltage Threshold set by users
Threshold values (512 samples/cycle)
THD, voltage harmonics 1
Harmonic order Up to the 50th order
Events
All events that occur in Accura 2500M/2550 modules are managed by Accura 2500M module. Each event is
recorded in event logs. Events are divided into power quality, measurement, and system events.
For power quality and measurement events, the last 100 events are stored respectively. For system events,
the last 1,000 events are stored, and the event index for each event is indicated with numbers from 0 to
9,999, allowing users to check recent events with ease.
When an event occurs, the EVENT LED at the bottom left corner of Accura 2500D flashes, and the color of
the bell icon on the upper right side of the screen changes to give notifications. The number of new events
that occur also appears with the bell icon.
Once you press the EVENT button at the bottom right corner of the device or the bell icon on the screen,
you can enter the event mode, and the EVENT LED is reset. In the event mode, you can check detailed event
information by selecting individual events, and the bell icon is reset.
Item Description
Power quality Dip/Swell, Type PQ Curve (SEMI F47, IEC 61000-4-11/34 Class 3, ITIC)
events 1 PQ Curve Measured value RMS data measured over 1 cycle
Transient voltage Measured value Differences between sampled voltage values
(512 samples/cycle)
Measurement Voltage connection Type Phase open/Fuse fail events 2
events events Measured value RMS data measured at 0.2 sec intervals
Time delay 1 second
Current events Measured value RMS data measured at 0.2 sec intervals
Leakage current Measured value RMS data measured at 0.2 sec intervals
events
User-defined Input data Data measured at 0.2 sec intervals, selectable among
events 3 voltage/current/power/leakage current / Etc.
Number of event 40
channels
1. It is calculated with line-to-line voltage in 3P3W mode and with line-to-neutral voltage in 3P4W mode.
2. When connected to a grounded 3P3W system, the device does not detect phase open and fuse fail events.
3. The event can be configured only via communication.
The following table shows items for measurement events provided via communication and Accura 2500D.
Measurement Events
There are voltage connection, current, leakage current, and user-defined events in measurement events.
Voltage connection events include phase open and fuse fail events. When connected with a grounded 3P3W
system, the device does not detect phase open and fuse fail events.
Current events refer to the events on the current values measured by Accura 2550 modules, and leakage
current events refer to the events on the leakage current values measured by Accura 2550CMZ modules.
Users can set up the event detection function, threshold, and hysteresis values for the events on each module
from Accura 2500D’s screen. For user-defined events, users can configure input data and event operation
methods via communication. Up to 40 user-defined events are supported with channels ranging from 1 to
40. User-defined event data for each channel is as shown below. For details about user-defined events, refer
to 「Chapter 6 Functions> Events > Measurement Events > User-Defined Events」.
System Events
System events include events on module management, communication status, and setup changes and are
recorded in event logs. When an event requiring inspection occurs, the device provides users with
notifications through the EVENT LED.
Accura 2500M automatically detects the connection status of all Accura 2550 modules connected with the
internal communication cable. It can also assign a communication ID to each module. The IDs of Accura
2550 modules connected to Accura 2500M should be set to enable communication with numbers ranging
from 0 to 39, and they should not be duplicated.
Accura 2500M sends the sampled voltage data to all Accura 2550 modules connected, enabling users to
measure power at individual branch lines. With internal communication cables, Accura 2500M receives
measurement data from multiple Accura 2550 modules.
Accura 2500D shows data on Accura 2500M, as well as measurement and operational status data of multiple
2550 modules collected by Accura 2500M. It enables users to check the entire operational status of the
devices in front of the industrial control panel via Accura 2500D’s TFT Color LCD screen. Users can set all
functions of Accura 2500M and Accura 2550 on the TFT Color LCD screen with the touch functionality.
Device Composition
The device composition of Accura 2500D is as follows.
The front panel of Accura 2500D consists of a 5” TFT LCD display, 4 LEDs, and 4 buttons. Accura 2500D has
one communication port and a built-in connector located at the back. Accura 2500D can be connected to
Accura 2500M by either using its built-in connector or the internal communication cable for the display
module.
LCD Display
Module LCD
Accura 2500D 5” (108.0 x 64.8 mm) Color TFT LCD (touch panel and backlight), 800 x 480 pixels
Button Functions
Item Operation Description
HOME Press Used to move to HOME>SUMMARY measurement screen.
SETUP Press Used to move to SETUP> SUMMARY setup screen.
EVENT Press Used to move to EVENT>SUMMARY event screen.
BACK Press Used to move to the previous screen.
Communication Port
Item Description
Port name DISPLAY (1 port)
Connector type RJ45 connector
Communication cable Internal communication cable for the display module 1 (Cat 5e 24 AWG FTP)
Protocol Internal protocol
Communication cable length Up to 3 m
Power supply Receives power from Accura 2500M through the built-in connector or
communication cable
1. It is provided with the product.
Device Connection
Accura 2500D receives power from Accura 2500M through its built-in connector or internal communication
cable for the display module.
DISPLAY(HOME) Mode
Screen Composition
Main Menu/Submenu
The main menu is located right below the top menu bar. Sub-menus for the main menu are provided on
the left in the vertical direction, allowing users to select the detail screen. Sub-menus are unavailable on the
SUMMARY measurement screen accessed by pressing the HOME button. By tapping each of six individual
sections on the measurement screen, users can directly move to the detail screen of the selected
measurement parameter and check detailed measurement data.
Measured Values
Accura 2500M/2550 perform gapless measurements of voltage and current at intervals of 0.2 seconds,
generating data for each time frame. Measured values for 1-second aggregation intervals are provided by
aggregating data from 5 consecutive frames. For details on Aggregation, refer to 「Chapter 6 Functions>
Aggregation」.
Maximum/Minimum Values
The maximum and minimum values and timestamp data for the values appear on the screen with the
Max/Min buttons on the upper right side of the device. The Max and Min values indicate the maximum
and minimum values among the measured values for each 0.2-second frame after the data have been cleared.
If the maximum and minimum values have never been updated since initialization, the timestamp data for
the values at the time of initialization are provided.
When you press the middle part of the module selection screen, you will navigate to the module connection
screen where you can check the connection status and operation status of all modules connected in the
daisy chain. From this screen, you can directly move to the measurement screen of the desired module by
pressing the desired module.
When modules are connected properly and communication IDs are successfully assigned for normal
communication, users can save the modules’ connection status. If the saved status differs from the current
connection status, the screen displays the difference, enabling inspection.
When the leakage current measurement module is connected, the connection status and leakage current
measurement values of the module can be monitored through the Status View. You can directly navigate
to the leakage current measurement screen of the desired module by pressing the corresponding module
ID on the screen, and the module IDs are displayed in ascending order within the Group. If the connection
status of the leakage current measurement module is good and the communication ID is correctly assigned,
the leakage current measurement values will be displayed. The digital input status is only shown for the
CMS/ZM split-core measurement module and the CMMZ MCB three-phase power/leakage measurement
module. Additionally, the feeder name is displayed as the string set in "SETUP > SYSTEM > Description >
User-Defined Info"; if not set, it will appear blank.
If there is a problem with the connection status of the leakage current measurement module, a warning
will be displayed in other areas to facilitate inspection. At this time, the ID number of the module with the
issue will blink in red, allowing the user to immediately identify and address the problem. Additionally, if
the ZM leakage measurement module is not connected and only the CMS split-core power measurement
module is connected, the module status will not be displayed in the Status View.
The table below shows the statuses displayed in the Status View. Users should review this information and
take appropriate action.
Display
It indicates the measurement screen that appears when AC is selected as voltage type on the main module
(indicated as Main) via 「SETUP > MEASUREMENT > AC/DC > Mode」 menu.
Once the HOME button is pressed, the SUMMARY measurement screen of the selected module appears.
When you press measurement parameters or measured values on the screen, you can move to the detail
screen of the relevant measurement parameter. By pressing the BACK button on the bottom of the device,
you can return to the SUMMARY measurement screen. Measurement parameters unavailable in certain
modules appear as “–“.
If you activate the 「Main A2550CM Assignment」 item and set “Main A2550CM ID” on the screen via
「SETUP > DEVICE > Main CM> Main A2550CM Assignment」 menu, the voltage measurement parameters
of the main module and the current/power/energy measurement parameters of the selected Accura 2550
power measuring modules appear on the measurement screen of the main module.
1. They indicate the Max/Min values when the sign of the power factor is removed.
2. Users can clear demand values of all Accura 2550 modules via the 「SETUP > CONTROL > Reset > Demand」 menu.
3. Users can clear peak demand values of all Accura 2550 modules via the 「SETUP > CONTROL > Reset > Peak
Demand」 menu.
ANALYSIS Screen
Fig 4. 14 Phasor Screen
Submenu Description
Description Indicates the device name, installation location and date, and description of the device
Local Time Indicates the local time and GMT offset
Network State Indicates the ethernet communication state
A2500M Indicates information on Accura 2500M module
A2500D Indicates information on Accura 2500D module
A2550CMZ Indicates information on Accura 2500CMZ module
SETUP Mode
Screen Composition
Main Menus/Submenus
The main menus are located right below the top menu bar. Sub menus for the main menus are provided on
the left in the vertical direction, allowing users to select the detail screen. Sub menus are unavailable on the
SUMMARY measurement screen accessed by pressing the SETUP button. By tapping each of six individual
sections on the measurement screen, users can directly move to the detail screen of the selected
measurement item and check detailed measurement data.
If users select MAIN on the module selection window in the menu bar at the top, the setup screen of the
main module appears. By tapping setup items on the screen, users can change preset values.
MEASUREMENT Setup
The MEASUREMENT setup screen consists of Voltage, Demand, Power, and AC/DC setup items.
When changing a value by selecting a setup item, the changed setup item is stored in the temporary
memory, and the Apply/Cancel button appears at the top right side of the screen.
EVENT Setup
The EVENT Setup screen consists of Dip(Sag), Swell, PQ Curve, Volt. Connection, and Transient Volt. setup
items.
Fig 4.19 Dip Event Setup Screen
NETWORK Setup
The NETWORK setup screen consists of Ethernet, RS-485, and Advanced setup items.
DEVICE Setup
The DEVICE setup screen consists of Main CM, Module ID and MCCB Status setup items.
CONTROL Setup
The CONTROL setup screen consists of Data Reset, Demand Sync and Test Mode setup items.
Demand Sync
Demand Sync 2 Confirm / Cancel 1
Test Mode
Test Mode Off / Balance / Unbalance Off
Timeout [min] 1 – 1440 min / Infinite 3 60 min
Fault Test Mode Off / Measurement / Module 1 / Off
Module 2 / Module 3 / Module 4 /
Ethernet 1 / Ethernet 2 / Loop / NTP
/ Heart Beat
1. A confirmation window asking to choose “Confirm” or “Cancel” appears on the screen.
2. If the Demand Sync mode accessed via 「SETUP > MEASUREMENT > Demand > Sync Mode」 is set to
“Manual Sync”, the starting time of the demand subinterval is synchronized to the time users issue
a sync command.
3. If the Timeout value is set to “Infinite”, the test mode continues.
SYSTEM Setup
The SYSTEM setup screen consists of Description, Local Time, Summer Time, NTP, LED, LCD & Buzzer, Module
LCD, and Locale setup items.
If you select the three-phase or single-phase power measuring module on the module selection window at
the top menu bar, the setup screen of the selected module appears. By pressing a setup item on the screen,
you can change values.
MEASUREMENT Setup
The MEASUREMENT setup screen consists of Current, Leakage and Load Wiring setup items.
EVENT Setup
The EVENT setup screen consists of Current and Leakage setup items.
Current
SYSTEM Setup
The SYSTEM setup screen consists of the Description setup item.
EVENT Mode
Screen Composition
Main Menus/Submenus
There are main menus, including MEASUREMENT, POWER QUALITY , and SYSTEM right below the top menu
bar. The submenus for the main menus are provided on the left in the vertical direction, allowing users to
easily check event data by filtering each event.
Events Subcategory
Measurement events
1 Voltage / Current / Power / Leakage Current / Etc.
Power Quality events Dip / Swell / SEMI F47 / IEC 61000 / ITIC / Transient Volt
System events Module / Communication / Setup / Etc.
1. Phase open and fuse fail events are categorized into voltage parameters.
MEASUREMENT Events
Accura 2500M saves the last 100 measurement events. If the number of events exceeds 100, the oldest
event gets deleted first. Each index for measurement events is indicated with the number from 0 to 9,999
(a greater index number indicates a more recent event). Thus, through the index number, users can check
the time the event occurred, as well as detailed event data. Using the sub-menus located on the left side of
the screen, users can easily check event data by filtering different types of events. Line open and fuse fail
events are categorized into voltage parameters. If users select one event from the events list, the Trend and
Read All button appear on the upper right side of the screen.
If users press the Trend button after selecting an event, the RMS trend screens indicating the data obtained
before and after the event occurred are shown. RMS trend data indicate RMS data measured over 1 cycle
for 3 frames before and after the event occurred. A frame consists of 12 cycles of RMS data at 60 Hz and
10 cycles of RMS data at 50 Hz. By using the submenus on the left, users can return to the desired event
list screen.
Accura 2500M saves the last 100 power quality events. If the number of events exceeds 100, the oldest event
gets deleted first. Each index for events is indicated with the number from 0 to 9,999 (a greater index number
indicates a more recent event). Through the index number, users can check the time an event occurred, as
well as detailed event data.
Using the submenus located on the left side of the screen, users can easily check event data by filtering
different types of events. If users select one event from the events list, the Trend and Read All button appear
on the upper right side of the screen. If users select one of SEMI F47-0706, IEC 61000-4-11/34 Class 3, and
ITIC events, the PQ Curve button also appears on the upper right side of screen. For Transient voltage events,
the Waveform button appears instead of the Trend button.
If users press the Trend button after selecting an event, the RMS trend screen indicating the data obtained
before and after the event occurs is shown. RMS trend data indicate RMS data measured over 1 cycle for 3
frames before and after the event occurred. A frame consists of 12 cycles of RMS data at 60 Hz and 10
cycles of RMS data at 50 Hz. By using the submenus on the left, users can return to the desired event list
screen.
If users select one of SEMI F47-0706, IEC 61000-4-11/34 Class 3, ITIC events and press the PQ Curve button,
all power quality events that have occurred, including the selected event appear with dots on the graph as
shown below. It enables users to statistically analyze trends in the occurrence of events at a glance. The
selected event appears red on the screen. By using the submenus on the left, users can return to the desired
event list screen.
SYSTEM Events
Accura 2500M saves the last 1,000 system events. If the number of events exceeds 100, the oldest event
gets deleted first. Each index for events is indicated with the number from 0 to 9,999 (a greater index number
indicates a more recent event). Thus, through the index number, users can check the time the event occurred,
as well as detailed event data. Using the submenus located on the left side of the screen, users can easily
check event data by filtering different types of events.
Users should select AC for the measured voltage type of AC industrial control panels. Accura 2550 modules
supporting AC measurement should be used in AC industrial control panels.
How to set up the measured voltage type on Accura 2500D screen is as follows.
▶ Main module (Main): 「SETUP > MEASUREMENT > AC/DC > Mode」
Step 2: Setup for the Voltage Wiring of Accura 2500M, PT Rating, and Reference Voltage
Users should set a voltage wiring mode according to the measured voltage type. Refer to 「Chapter 6
Functions> Measurements > Voltage Wiring」 for details on voltage wiring.
How to set up voltage wiring on the Accura 2500D screen is as follows.
▶ Main module (Main): 「SETUP > MEASUREMENT > Voltage > Wiring」
When using external PTs, users should set the primary voltage and the secondary voltage of the PT. The
ratio of the primary to secondary values is used as the conversion ratio for the primary voltage of the PT.
Regardless of voltage wiring modes, line-to-line voltage values should be entered. In case of 1P2W
connection, the line-to-line voltage is the same as the line-to-neutral voltage. When external PTs are not
used, set the primary voltage and the secondary voltage values of the PT to the same values.
How to set up the reference voltage on the Accura 2500D screen is as follows.
▶ Main module (Main): 「SETUP > MEASUREMENT > Voltage > PT Primary Voltage / PT Secondary Voltage」
Users should also set up the reference voltage used for Dip(Sag)/Swell detection and the evaluation of the
PQ Curve. The reference voltage is the primary voltage of the PT.
▶ Main module (Main): 「SETUP > MEASUREMENT > Voltage > Reference Primary Voltage」
The IDs of Accura 2550 modules connected to Accura 2500M should be set to the ID numbers that enable
communication. The ID numbers of Accura 2550 modules should be selected from 0 to 39 and should not
be duplicated. Users can set up the ID with the SET button on Accura 2550 module. Refer to 「Chapter 5
Accura 2550 > Accura 2550CM[Z]-3P/1P Module > Setup Mode> ID Setup」 for details about Module ID
Setup.
▶ Accura 2550 > SET button
Users can also set up the IDs of all Accura 2550 modules at once on the setup screen of Accura 2500D
module. For details about the module ID setup, refer to 「Chapter 4 Accura 2500D > Setup Mode > Setup
of Accura 2500M > DEVICE Setup」. How to set up module IDs on Accura 2500D screen is as follows.
▶ Main module (Main): 「SETUP > DEVICE > Module ID > Auto Assignment」
IP Address, Subnet Mask, and Gateway should be set up for Ethernet communication with the host system.
How to perform Ethernet setup on the Accura 2500D screen is as follows.
▶ Main module (Main): 「SETUP > NETWORK > Ethernet」
Operation Mode
The front panel of Accura 2550 module consists of an LCD screen displaying measured values and setup
data, as well as one SET button. The LCD screen features the following two operation modes.
Mode Description
Display mode Indicates IDs and measured values (current, power, etc.) in sequence. By setting up the display
mode of Accura 2500D device, users can make specific measured values appear on the screens
of all Accura 2550 modules.
Setup mode In this mode, users can set up IDs, the rated current, and various timeouts. If there is no
button operation for 30 seconds (the operating time can be set), the operation mode
automatically changes to the display mode.
Button Operation
Button Description
Display Mode
Short press 1 Move between screens manually (Each time the button is pressed, the
display screen changes to the next screen).
Long press 2
Enter the setup mode.
Setup Mode
Short press 1 Move between setup screens (Each time the button is pressed, the setup
screen is selected in sequence.)
Long press 2 Enter the edit mode in which you can change settings
A preset value blinks, and you can change it.
Long press 2 Save the selected set value (blinking stops) and return to the setup mode.
(Long press the button to change the setting of the next digit.)
1. Short press the button to move to the previous screen. Double press the button within 0.25 seconds to move to
the next screen.
2. Release the button after pressing it for one second.
Note
If there is no button operation for 30 seconds (the operating time can be set) in the setup mode or the
edit mode, the screen automatically returns to the display mode.
Applied Models
Model Basic Current Measurement Range Minimum
(lb) (Accuracy Guaranteed) Measured Value
Accura 2550CM-3P -800A-210 800 A 16.0 A − 960 A 0.80 A
-5A-ZCT 1
5A 0.1 A − 6A 0.01 A
1. Accura 2550CM-3P-5A module can be used by externally installing CTs (the secondary current rating: 5 A).
2. Accura 2550CM-3P, which can connect an external ZCT, module measures leakage current by connecting an externally
installed voltage-type ZCT to its ZCT connection port. The user must purchase the ZCT separately from the ZCT
manufacturer.
Item Specification
Current Measurement accuracy IEC 61557-12 Class 0.5 ±0.5 % Reading
Leakage current 1
Fundamental current CM-3P-800A/630A/400A/5A-ZCT ±2 % Reading ± 2 mA
measurement accuracy CMZ-3P-800A ±0.5 % Reading ± 60 mA
CMZ-3P-630A/400A/250A ±0.5 % Reading ± 30 mA
CMZ-3P-125A/100A/60A ±0.5 % Reading ± 20 mA
LCD Display
Indication
ID Module ID 1
Module ID ID Description
Display Mode
Accura 2550CM[Z] module shows the display screen in the following sequence. By short pressing the SET
button, you can manually change the automatic display screen. Long press the SET button to enter the
setup mode.
Average
A Current/ B Current/ C Current/ Leakage
ID Current/
Power Power Power Current 1
Total Power
1. The data are available with Accura 2550CMZ modules and Accura 2550CM-3P modules, which can connect to an
external ZCT.
Setup Mode
Setup Menu
If users short press the SET button, the setup menu appears in the following sequence.
Phase
ID Rated Current Load Direction Load Mode 1 CT Ratio 3
Sequence 2
Note
If there is no button operation for 30 seconds(the operating time can be set) in the setup mode or the edit
mode, the operation mode automatically returns to the display mode.
ID Setup
Item Range Description
ID [d][d] 1
Module ID 2
setup
0 – 39 (default 255)
1. d → decimal number
2. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Conflict ID Duplicate IDs There are more than 2 identical IDs.
Communication unavailable
1. d → decimal number
2. The basic current of the three-phase power measuring module is as follows. The value set by users cannot exceed
the basic current value.
Single-phase load
Negative sequence
Phase selection
(When the load mode is set
to single-phase load)1
1. Phase selection data for a single-phase load are indicated with two letters. The letter indicating the phase of
the cable passing through the hole of the module comes first.
CT Ratio Setup
The setup screen is available only on Accura 2550CM-3P-5A model that can be used by externally installing
CTs(the secondary current rating: 5 A).
1. d → decimal number
Applied Models
Item Specification
Current Measurement accuracy IEC 61557-12 Class 0.5 ±0.5 % Reading
Leakage current 1 Fundamental current CMZ-1P-250A ±0.5 % Reading ± 30 mA
measurement accuracy CMZ-1P-125A/100A/60A ±0.5 % Reading ± 20 mA
Measuring range 1 mA – 2 A
Active power Measurement accuracy IEC 61557-12 Class 0.5
Active energy Measurement accuracy IEC 62053-21 Class 0.5
1. The data are available with Accura 2550CMZ modules.
LCD Display
Indication
ID Module ID 1
Accura 2550CM[Z]-1P-250A
Accura 2550CM[Z]-1P-125A/100A/60A
1. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Conflict ID Duplicate IDs There are more than 2 identical IDs.
Communication unavailable
Standby ID ID 255 Module ID for checking connection status.
Communication unavailable
Display Mode
Accura 2550CM[Z]-1P-250A module shows the display screen in the following sequence.
Accura 2550CM[Z]-1P-125A/100A/60A module shows the display screen in the following sequence.
By short pressing the SET button, you can manually change the automatic display screen. Long press the
SET button to enter the setup mode.
Setup Mode
Setup Menu
The setup mode screen of Accura 2550CM[Z]-1P-250A module is as follows. If users short press the SET
button, the setup menu appears in the following sequence.
The setup mode screen of Accura 2550CM[Z]-1P-125A/100A/60A module is as follows. If users short press
the SET button, the setup menu appears in the following sequence.
Note
If there is no button operation for 30 seconds(the operating time can be set) in the setup mode or the edit
mode, the operation mode automatically returns to the display mode.
ID Setup
Item Range Description
ID [d][d] 1 Module ID 2 setup
0 – 39 (default 255)
1. d → decimal number
2. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Conflict ID Duplicate There are more than 2 identical IDs.
IDs Communication unavailable
Standby ID ID 255 Module ID for checking connection status.
Communication unavailable
1. d → decimal number
2. The basic current of the single-phase power measuring module is as follows. The value set by users cannot exceed
the basic current.
Select Line-to-Neutral.
(default)
Select Line-to-Line.
1. The phase selection data of a single-phase load are indicated with two letters. The letter indicating the phase of
the cable passing through the first hole of the module comes first.
Applied Models
Module Basic Current Measuring Range Minimum
(Ib) (Accuracy Guaranteed) Measured Value
Item Specification
Current Measurement accuracy 1 IEC 61557-12 Class 0.5 ±0.5 % Reading
Leakage current 2, 3
Fundamental current ZM-3P4W-60A-DI ±0.5 % Reading ± 10 mA
measurement accuracy
Measuring range 1 mA − 2 A
Active power Measurement accuracy 1
IEC 61557-12 Class 0.5
LCD Display
Indication
ID Module ID 1
1. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Display Mode
Accura 2550CMS module shows the display screen in the following sequence. By short pressing the SET
button, you can manually change the automatic display screen. Long press the SET button to enter the
setup mode.
Average
A Current / B Current / C Current / Leakage
ID Current /
Power Power Power Current 1
Total Power
1. Accura 2550CMS module displays leakage current data when Accura 2550ZM module is connected.
Setup Mode
Setup Menu
If users short press the SET button, the setup menu appears in the following sequence.
Note
If there is no button operation for 30 seconds(the operating time can be set) in the setup mode or the edit
mode, the operation mode automatically returns to the display mode.
ID Setup
Item Range Description
ID [d][d] 1
Module ID 2
setup
0 – 39 (default 255)
1. d → decimal number
2. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
1. d → decimal number
2. The basic current of the three-phase power measuring module is as follows. The value set by users cannot exceed
the basic current value.
Negative sequence
Applied Models
Item Specification
Current Measurement accuracy 1 IEC 61557-12 Class 0.5 ±0.5 % Reading
Leakage current 2
Fundamental current ZM-1P3F/1P2F-60A ±0.5 % Reading ± 5 mA
measurement accuracy
Measuring range 1 mA − 2 A
Active power Measurement accuracy 1
IEC 61557-12 Class 0.5
Active energy Measurement accuracy 1 IEC 62053-21 Class 0.5
1. The split-core CMS module has been calibrated under the condition where the power line passes through the top
center position of its hole. As the location of the power line is away from the top center position of the hole, errors in
current, power, and energy measurements can increase by up to 1 %.
2. The data are available with Accura 2550ZM modules.
LCD Display
Indication
ID Module ID 1
1. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Display Mode
Accura 2550CMS module shows the display screen in the following sequence. By short pressing the SET
button, you can manually change the automatic display screen. Long press the SET button to enter the
setup mode.
Setup Mode
Setup Menu
If users short press the SET button, the setup menu appears in the following sequence.
1. The Accura 2550CMS-1P2F module only displays the rated current setup data for Feeder 1 and Feeder 2.
2. The load direction setting applies to feeders 1, 2, and 3.
Note
If there is no button operation for 30 seconds(the operating time can be set) in the setup mode or the edit
mode, the operation mode automatically returns to the display mode.
ID Setup
Item Range Description
1. d → decimal number
2. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Conflict ID Duplicate IDs There are more than 2 identical IDs.
Communication unavailable
Standby ID ID 255 Module ID for checking connection status,
Communication unavailable
1P3F 1P2F
1P3F 1P2F
Line-to-Neutral selected
(default)
Line-to-Line selected
In the 1P2F module, current sensors for individual feeders are located in its first and third holes. The two
current sensors measure forward currents, and when wiring the module, the Hot line should pass through
the first and third holes of the module. The phase selection mode of the module for each feeder can be set
to line-to-neutral or line-to-line.
Line-to-Neutral selected
(default)
Line-to-Line selected
Applied Model
Item Specification
Current Measurement accuracy IEC 61557-12 Class 0.5 ±0.5 % Reading
Leakage current 1 Fundamental current CMMZ-3P-60A ±0.5 % Reading ± 10 mA
measurement accuracy
Measuring range 1 mA − 2 A
Active power Measurement accuracy IEC 61557-12 Class 0.5
Active energy Measurement accuracy IEC 62053-21 Class 0.5
1. It is only supported on Accura 2550CMMZ-3P module.
LCD Display
Indication
ID Module ID 1
1. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Conflict ID Duplicate IDs There are more than 2 identical IDs.
Communication unavailable
Standby ID ID 255 Module ID for checking connection status,
Communication unavailable
Display Mode
Accura 2550CMM[Z] module shows the display screen in the following sequence. By short pressing the SET
button, you can manually change the automatic display screen. Long press the SET button to enter the
setup mode.
Setup Mode
Setup Menu
If users short press the SET button, the setup menu appears in the following sequence. Accura 2550CMM[Z]
module allows users to select and utilize three-phase multi-feeder functionality depending on the load type.
ID Rated Current Load Direction 1
Phase Selection
Note
If there is no button operation for 30 seconds(the operating time can be set) in the setup mode or the edit
mode, the operation mode automatically returns to the display mode.
ID Setup
Item Range Description
1. d → decimal number
2. Module IDs are divided into three types of IDs as follows. The standby ID 255 is assigned to all Accura 2550 modules
as a factory default value.
Module ID ID Description
Communication ID ID 0 – 39 ID of the module available for communication
Conflict ID Duplicate IDs There are more than 2 identical IDs.
Communication unavailable
Standby ID ID 255 Module ID for checking connection status,
Communication unavailable
1. The basic current of the three-phase power measuring module is as follows. The value set by users cannot exceed
the basic current value.
Single-phase load
Negative sequence
Phase selection
(When the load mode is set
to single-phase load) 1
Chapter 6 Functions
Voltage/Current Sampling
Accura 2500M module measures both AC and DC voltage. However, Accura 2550 modules are divided into
the module that measures AC current and the module that measures DC current. Therefore, you should use
the Accura 2550 module that suits your needs according to the AC/DC voltage specifications of the industrial
control panel.
Voltage Sensing
In Accura 2500M module, voltages drop due to the industrial control of resistance and are converted to the
ADC values through the AAF(Anti-Aliasing Filter). Obtained voltage data are converted into voltage
harmonics up to 50th order with the FFT(Fast Fourier Transform) algorithm. The processed voltage data are
sent to all the three-phase/single-phase power measuring modules connected with internal communication
cables.
Current Sensing
In Accura 2550 module, current values are converted through a Hall-Effect sensor or CT(Current Transformer)
and converted to ADC values through the AAF(Anti-Aliasing Filter). Obtained current data are converted into
current harmonics up to the 50th order with the FFT algorithm. Data on power and energy are obtained
based on the processed current data and the voltage data received from Accura 2500M module.
Measuring Time
Gapless sampling and calculation of measured signals are performed per cycle. Frame data are generated
by collecting data obtained over a period of 12 or 10 cycles. These data are aggregated, creating the data
for a period of longer than 0.2 seconds. For details about aggregation, refer to 「Chapter 6 Functions>
Aggregation」.
The frequency of the power source is automatically detected. For frequencies higher than 55 Hz,
measurements are performed at 60 Hz, and for those lower than 55 Hz, measurements are performed at 50
Hz. A frame refers to 0.2 seconds. It consists of 12 cycles at 60 Hz and 10 cycles at 50 Hz.
Gapless processing of voltage and current signals is performed per cycle. Voltage sampling includes 512
samples per cycle while current sampling includes 256 samples per cycle. For each cycle, an FFT is performed
for voltage and current signals, and DC, RMS, fundamental, power and energy values are calculated based
on the values obtained during subsequent cycles.
50
50
Measurements
Measurement Parameters
The following table shows measurement parameters. Some of measurement data are provided only via
communication. Measured values displayed on Accura 2500D module are values obtained for 1-second
aggregation intervals generated by aggregating data from 5 frames. Measured values provided via
communication are values obtained for the aggregation intervals of 0.2, 1, and 5 seconds, 1 and 5 minutes,
1 and 6 hours. Users can choose the aggregation interval via communication. The default aggregation
interval is set to 1 second.
The maximum and minimum values provided on the Accura 2500D screen after resetting the max/min values
are stored in non-volatile memory. Thus, the data are maintained even when Accura 2500M is turned off.
▣ Displayed on Accura 2500D and provided via communication □ Available only via communication
Voltage Wiring
V1 VB = V2
VC = V3
There is no actual neutral point in three-phase, three-wire voltage connection mode. Thus only line-to-line
voltage and the total power can be measured, but the actual voltage and power for each phase cannot be
measured. However, by using a virtual neutral point where the residual voltage value of three phase voltages
becomes zero, voltage and power values for each phase can be calculated.
A phase VA 0 IA (I1) PA QA SA
B phase 0 0 0 0
A phase VA VA IA (I1) PA QA SA
B phase 0 0 0 0
C phase 0 0 0 0
Average/Total VA VA IA PA QA SA
Residual Voltage
For three-phase voltage measurement, line-to-neutral voltage for each phase is calculated with the following
formula including harmonic voltages up to the 50th order.
50
Residual voltage is generated by adding up each line-to-neutral voltage for each harmonic order, and the
RMS values are provided.
𝑣𝑟𝑠𝑑 = ∑ 𝑣𝑚 (𝑡)
𝑚=𝑎,𝑏,𝑐
The fundamental residual voltage is calculated by summing up the fundamental voltage of line-to-neutral
voltage on each phase.
Residual Current
For three-phase current measurement, line-to-neutral current for each phase is calculated with the following
formula including harmonic currents up to the 50th order.
.
50
Residual current is generated by adding up each line-to-neutral current for each harmonic order, and the
RMS values are provided.
𝑖𝑟𝑠𝑑 = ∑ 𝑖𝑚 (𝑡)
𝑚=𝑎,𝑏,𝑐
Leakage Current
Accura 2550CMZ power/leakage current measuring modules and Accura 2550ZM leakage current measuring
module have built-in ZCTs. The leakage current sensed by the ZCT is calculated with the following formula
including harmonic currents up to the 50th order. The RMS and fundamental values are provided for the
leakage current.
50
AC Three-Phase Load
Load Module Note
Current 3P4W 3P3W
800A A2550CM-3P-800A-210-ZCT + external ZCT A2550CMZ-3P-800A-220 Caution 1
125A A2550CMZ-3P-125A
100A A2550CMZ-3P-100A
60A - A2550CMZ-3P-60A For general
A2550CMZ-3P-60A For MCB
A2550CMS-3P4W-60A + A2550ZM-3P4W-60A-DI Split-core
(Connection of the leakage current measurement module)
5A A2550CM-3P-800A-210-ZCT + external ZCT Caution 1, 3
1. Accura 2550CM-3P module, which can connect an external ZCT, measures leakage current by connecting an externally
installed voltage-type ZCT to its ZCT connection port. The user must purchase the ZCT separately from the
ZCT manufacturer.
2. When applying the 250A leakage current measurement module to a 125A or 100A MCCB, caution is required during
installation because the width of the MCCB and the module do not match.
3. Leakage current measurement modules designed for three-phase 4-wire systems can also be applied to three-phase
3-wire systems during leakage current measurement.
AC Single-Phase Load
Load Module Note
Current
250A A2550CMZ-1P-250A -
125A A2550CMZ-1P-125A
100A A2550CMZ-1P-100A
60A A2550CMZ-1P-60A For general
A2550CMS-1P2F-60A + A2550ZM-1P2F-60A-DI Split-core,
(Connection of the leakage current measurement module) 2 feeder
A2550CMS-1P3F-60A + A2550ZM-1P3F-60A-DI Split-core,
(Connection of the leakage current measurement module) 3 feeder
The average active power per phase is calculated by multiplying voltage by current.
50
There are two methods for calculating the reactive(Q) and apparent power(S) per phase.
1) Calculation from fundamental frequency components: Reactive power is calculated based on the
fundamental voltage and current values.
2) Calculation from RMS values: Reactive power is calculated based on the RMS voltage and current values
(including harmonics).
Reactive power and apparent power values can vary according to the method of calculating reactive power.
As the apparent power value changes, the power factor also changes.
Apparent power per phase is calculated with the vector sum of active power and reactive power.
𝑆𝑚 = √𝑃𝑚2 + 𝑄𝑚
2
𝑤ℎ𝑒𝑟𝑒 𝑚 = 𝑎, 𝑏, 𝑐
50 50
2 2 2 2
𝑉𝑟𝑚𝑠,𝑚 = √𝑉𝑑𝑐,𝑚 + ∑ 𝑉𝑘,𝑚 𝐼𝑟𝑚𝑠,𝑚 = √𝐼𝑑𝑐,𝑚 + ∑ 𝐼𝑘,𝑚 𝑤ℎ𝑒𝑟𝑒 𝑚 = 𝑎, 𝑏, 𝑐
𝑘=1 𝑘=1
𝑆𝑚 = 𝑉𝑟𝑚𝑠,𝑚 𝐼𝑟𝑚𝑠,𝑚
The magnitude of reactive power per phase is calculated based on apparent power and active power values
including harmonics. The sign of reactive power is the same as the sign of reactive power calculated with
fundamental frequency components.
2 − 𝑃2
𝑄𝑚 = ±√𝑆𝑚 𝑚
Three-Phase Power
There are two methods for calculating the total three-phase reactive power(Qt) and apparent power(St).
1) Vector sum: The total apparent power is calculated based on the vector sum of three phase power.
2) Arithmetic sum: The total apparent power is calculated based on the arithmetic sum of three phase
power.
Total apparent and reactive power values can vary according to the method of calculating the total three
phase apparent power. As the total apparent power value changes, the total PF also changes.
The total reactive power is calculated by adding up the reactive power for each phase.
𝑄𝑡 = 𝑄𝑎 + 𝑄𝑏 + 𝑄𝑐
The total apparent power is calculated based on the vector sum of the total active power and reactive power.
𝑆𝑡 = √𝑃𝑡2 + 𝑄𝑡2
Qt Qc St
Sc Qc
Pc
Qb
Sb Qb
Pb
Qa
Qa
Sa
Pa Pb Pc
Pt | St |
The total apparent power is calculated with the arithmetic sum of three phase apparent power vectors.
𝑆𝑡 = |𝑆𝑎 | + |𝑆𝑏 | + |𝑆𝑐 |
The magnitude of the total reactive power is calculated by calculating the magnitude of vector difference
between the total apparent power and active power. The sign of the total reactive power is the same as that
of the total reactive power calculated with the vector sum calculation method.
𝑄𝑡 = ±√𝑆𝑡2 − 𝑃𝑡2
Qt St
Sc Qc
Pc
Sb Qb
Pb
Qa
Sa
Pa Pb Pc
Pt | St |
Power Factor(PF)
PF
Power Factor is the ratio of active power to apparent power. The sign of a power factor value is a positive
or negative value according to the sign of active power. A positive PF indicates the power is in received
status, and a negative PF indicates the power is in delivered status. If the apparent power is 0, the power
factor cannot be calculated. In this case, it can be set to 1.0 or 0.0, and the default value is 1.0.
𝑃𝑎 𝑃𝑏 𝑃𝑐
𝑃𝐹𝑎 = , 𝑃𝐹𝑏 = , 𝑃𝐹𝑐 =
𝑆𝑎 𝑆𝑏 𝑆𝑐
𝑃𝑡
𝑃𝐹𝑡 =
𝑆𝑡
The sign of the power factor can be removed through configuration. In this case, the received/delivered
status cannot be identified only through the power factor. How to calculate the PF when its sign is removed
is as follows.
𝑃𝑎 𝑃𝑏 𝑃𝑐
𝑃𝐹𝑎 = | |, 𝑃𝐹𝑏 = | |, 𝑃𝐹𝑐 = | |
𝑆𝑎 𝑆𝑏 𝑆𝑐
𝑃𝑡
𝑃𝐹𝑡 = | |
𝑆𝑡
PF Angle (Lead/Lag)
The following figure shows the relationship between the sign of the power factor and Leading/Lagging
power factors for phase angles of voltage and current in the 4 quadrants. When reactive power(Q) is zero,
it is neither in leading nor lagging status.
Energy
Active Energy
Active power is accumulated in the unit of Wh for each sign. Active power data are displayed on the screen
of Accura 2500D and provided via communication in the unit of kWh. If the unit of energy is changed from
kWh to Wh through device setup, active energy is displayed on the screen of Accura 2500D and also
provided via communication in the unit of Wh.
The accumulated value for positive active power refers to received active energy, indicating power is
consumed. However, the accumulated value for negative active power refers to delivered active energy,
indicating power is supplied. Sum(Total) energy refers to the value obtained by adding delivered energy to
received energy. Net energy is the value obtained by subtracting delivered energy from received energy.
Active Energy Integer of the Accumulated Value Unit of Accumulation Available Data
Received 123,456 Wh 123 kWh
Delivered 11,222 Wh 11 kWh
Sum (Total) 134,678 Wh 134 kWh
Net 112,234 Wh 112 kWh
Reactive Energy
Reactive power is accumulated in the unit of VARh for each of the four quadrants. The screen of Accura
2500D displays reactive energy in the unit of kVARh. If the unit of energy is changed from kWh to Wh
through device setup, reactive energy is displayed on the screen of Accura 2500D and also provided via
communication in the unit of VARh.
The accumulated values for positive reactive power in quadrants 1 and 2 indicate positive reactive energy.
The accumulated values for negative reactive power in quadrants 3 and 4 indicate negative reactive energy.
Reactive Energy Integer of the Accumulated Value Unit of Accumulation Available Data
Quadrant 1 123,456 VARh 123 kVARh
Quadrant 2 22,000 VARh 22 kVARh
Quadrant 3 33,000 VARh 33 kVARh
Quadrant 4 44,000 VARh 44 kVARh
Apparent Energy
Apparent power is accumulated in the unit of VAh. The screen of Accura 2500D module displays apparent
energy in the unit of kVAh. If the unit of energy is changed from kWh to Wh through device setup, apparent
energy is displayed on the screen of Accura 2500D and also provided via communication in the unit of VAh.
Apparent Energy Integer of the Accumulated Value Unit of Accumulation Available Data
- 123,456 VAh 123 kVAh
Demand
Demand Measurement
Demand time(Tdmd) is determined by multiplying a demand subinterval(Tsub) by the number of demand
subintervals. The average value of the demand time(Tdmd) is calculated over the sliding demand subinterval.
Peak demand is the maximum value obtained after the reset of the maximum and minimum values.
Demand time(Tdmd) [minute] = demand subinterval (Tsub) x the number of demand subintervals
E.g.) In Korea, 15 minutes is used as a demand subinterval, and the number of demand subintervals is 1.
Avg 2.6 Avg 3.0 Avg 4.0 Avg 4.8 Avg 4.3 Avg 2.5
demand output 3.47 3.20 3.93 4.37 3.87 (updated every Tsub)
Thermal Demand
The thermal demand(Pth) is calculated through the 1st-order LPF(low-pass-filter) as shown in the following
formula that includes the demand value(P) and the t value. The thermal demand(Pth) value is used to calculate
predicted demand.
1 1
𝑃𝑡ℎ [𝑛] = (1 − ) ∙ 𝑃𝑡ℎ [𝑛 − 1] + ∙ 𝑃[𝑛]
𝜏 𝜏
Here, τ refers to the thermal time constant, and it is calculated through the following formula, including the
thermal response index.
Predicted Demand
Predicted demand indicates that the demand at the end of the demand subinterval(Tsub) is predicted every
second while the subinterval continues. The average value of the current demand subinterval is calculated
every second, assuming that the thermal demand value remains constant during the remaining subinterval
while the current demand subinterval continues. Based on the average value, the predicted demand value
at the end of the demand subinterval is calculated.
Demand Sync
Accura 2500 supports two methods for synchronizing the starting time of a demand subinterval.
1) Hourly Auto Sync: automatically synchronizes the starting time of a demand subinterval every hour
2) Manual Sync: synchronizes the starting time of a demand subinterval at the time users issue a sync
command
For Hourly Auto Sync, synchronization is performed every 60 minutes. Thus, demand calculation is performed
only when the demand subinterval is an integer divided by 60. (demand subinterval(Tsub) = 1 minute, 2
minutes, 3 minutes, 4 minutes, 5 minutes, 6 minutes, 10 minutes, 12 minutes, 15 minutes, 20 minutes, 30
minutes, 60 minutes). A sync command for Manual Sync can be issued via 「SETUP > CONTROL > Reset >
Demand Sync」 menus or communication.
Avg 2.9 Avg 4.6 Avg 4.8 Avg 2.6 Avg 3.9 Avg 3.1
Avg 4.3 Avg 4.7 Avg 2.9 Avg 3.4 Avg 3.2
Harmonics
Voltage Harmonics
Voltage sampling includes 512 samples per cycle, and the THD is calculated using harmonics up to the 50th
order.
50
The following formula shows how to calculate voltage THD for each phase.
√∑50 2
𝑘=2 𝑉𝑘,𝑚
𝑇𝐻𝐷𝑉,𝑚 =
𝑉1,𝑚
Current Harmonics
Current sampling includes 256 samples per cycle, and THD is calculated using harmonics up to the 50th
order.
50
The following formula shows how to calculate current THD for each phase.
√∑50 2
𝑘=2 𝐼𝑘,𝑚
𝑇𝐻𝐷𝐼,𝑚 =
𝐼1,𝑚
𝑀𝑎𝑥(𝛥𝑉𝑝ℎ)
𝑃ℎ𝑎𝑠𝑒 𝑉𝑜𝑙𝑡𝑎𝑔𝑒 𝑈𝑛𝑏𝑎𝑙𝑎𝑛𝑐𝑒 = × 100 [%]
𝑉𝑝ℎ, 𝑎𝑣𝑔
𝑀𝑎𝑥(𝛥𝑉𝐿𝐿)
𝐿𝑖𝑛𝑒 𝑡𝑜 𝐿𝑖𝑛𝑒 𝑉𝑜𝑙𝑡𝑎𝑔𝑒 𝑈𝑛𝑏𝑎𝑙𝑎𝑛𝑐𝑒 = × 100 [%]
𝑉𝐿𝐿, 𝑎𝑣𝑔
Current Unbalance
It indicates the maximum current deviation from the average value of three-phase currents. Even when the
magnitudes of currents are the same and current unbalance occurs between phases, the current unbalance
value is zero.
𝑀𝑎𝑥(𝛥𝐼𝑝ℎ)
𝐶𝑢𝑟𝑟𝑒𝑛𝑡 𝑈𝑛𝑏𝑎𝑙𝑎𝑛𝑐𝑒 = × 100 [%]
𝐼𝑝ℎ, 𝑎𝑣𝑔
Negative-Sequence/Zero-Sequence Unbalance
The fundamental components of three-phase currents and voltages can be divided into zero-sequence,
positive-sequence and negative-sequence components.
Zero-sequence component(U0): the component with the same magnitude and phase angle
Positive-sequence component(U1): three-phase symmetrical components with the phase sequence of A-B-C
Negative-sequence component(U2): three-phase symmetrical components with the phase sequence of
A-C-B
𝑈0 1 1 1 1 𝑈𝑎 2𝜋
𝑗∙
[𝑈1 ] = ∙ [1 𝑎 𝑎2 ] ∙ [𝑈𝑏 ] , 𝑤ℎ𝑒𝑟𝑒 𝑎 = 𝑒 3
3
𝑈2 1 𝑎2 𝑎 𝑈𝑐
Negative-Sequence Unbalance
It is the ratio between the magnitudes of the negative-sequence component and the positive-sequence
component. The negative sequence unbalance of line-to-line voltages is always the same as the negative
sequence unbalance of line-to-neutral voltages.
𝑈2
𝑁𝑒𝑔𝑎𝑡𝑖𝑣𝑒 𝑠𝑒𝑞𝑢𝑒𝑛𝑐𝑒 𝑢𝑛𝑏𝑎𝑙𝑎𝑛𝑐𝑒 = × 100 [%]
𝑈1
Zero-Sequence Unbalance
It is the ratio between the magnitudes of the zero-sequence component and the positive-sequence
component. The zero-sequence component of line-to-line voltages is always 0.
𝑈0
𝑍𝑒𝑟𝑜 𝑠𝑒𝑞𝑢𝑒𝑛𝑐𝑒 𝑢𝑛𝑏𝑎𝑙𝑎𝑛𝑐𝑒 = × 100 [%]
𝑈1
Events
Power Quality Events
Factories, including semiconductor manufacturing plants need high quality power due to sensitive
manufacturing equipment and demanding manufacturing process control. For assessment of the power
quality of the supplied power, Accura 2500M supports Dip/Swell detection functions and three PQ curves,
such as SEMI F47-0706, IEC 61000-4-11/34 Class 3 and ITIC. It continuously generates RMS voltage values per
cycle to assess power quality. It generates RMS values of line-to-neutral voltages and line-to-line voltages
in 3P4W mode and in 3P3W mode, respectively. For power quality(PQ) events, it provides RMS trend data
measured over 1 cycle, as well as data on depth and duration.
Users can check power quality events through the events list in the event mode on Accura 2500D module.
The graph screen provides data on depth and duration, enabling users to view data on the power quality
events that have occurred at a glance. Also, it offers 1-cycle RMS trend data for three frames (before/when/
after the event occurs), which allows for detailed analysis of the event.
Accura 2500M also supports the function of detecting transient voltage events to monitor voltage transients
measured in three phases. It performs voltage sampling at a rate of 512 samples per cycle and monitors
differences between sampled voltage values. By providing waveform data measured over one half cycle
before and after a transient voltage event occurs, it allows for analysis of transient voltages. Accura 2500M
monitors line-to-neutral voltages and line-to-line voltages in 3P4W mode and 3P3W mode, respectively.
Dip(Sag)/Swell
Dip/swell functions operate based on the threshold and hysteresis set by users.
Fig 6.16 Voltage Dip Detection
PQ Curve
Accura 2500M provides assessment of PQ curves, including standards such as SEMI F47-0706, IEC 61000-4-
11/34 Class 3 and ITIC. The thresholds of the PQ curve are 90 %/110 % of the reference voltage, and the
hysteresis level is 2 % of the reference voltage. Users can set up the reference voltage of Accura 2500M.
PQ Curve Organization
SEMI F47-0706 SEMI(Semiconductor Equipment and Materials Institute)
IEC 61000-4-11/34 Class 3 IEC(International Electrotechnical Commission)
ITIC ITIC(Information Technology Industry Council)
SEMI F47-0706
The following table and Fig 6.17 indicate the depths and durations of voltage dips.
90
Percentage of Reference Voltage (% Vref)
80
70
60
50
40
30
20
10
0
0.6 c 1 c 6 c 12 c 30 c 60 c 600 c 6000 c
0.01 s 0.0167 s 0.1 s 0.2 s 0.5 s 1 s 10 s 100 s
Duration
90
Percentage of Reference Voltage (% Vref)
80
70
60
50
40
30
20
10
0
0.6 c 1c 6c 12 c 30 c 60 c 300 c 6000 c
0.01 s 0.0167 s 0.1 s 0.2 s 0.5 s 1s 5s 100 s
Duration
ITIC
The ITIC curve contains transients shorter than one cycle for voltage swells as shown in the table below.
However, Accura 2500M evaluates voltage swells based on RMS values measured over one cycle, thus, it
does not support measurements of transients.
180
Percentage of Reference Voltage (% Vref)
160
140
120
100
80
60
40
20
0
0.6 c 1 c 6 c 12 c 30 c 60 c 600 c 6000 c
0.01 s 0.0167 s 0.1 s 0.2 s 0.5 s 1 s 10 s 100 s
Duration
Transient Voltage
Accura 2500M supports the function of detecting transient voltage events to monitor voltage transients
measured in three phases. It performs voltage sampling at a rate of 512 samples per cycle and monitors
differences between sampled voltage values. By providing waveform data measured over one half cycle
before and after a transient voltage event occurs, it allows for analysis of transient voltages. Accura 2500M
monitors line-to-neutral voltages and line-to-line voltages in 3P4W mode and 3P3W mode, respectively.
Measurement Events
Measurement events include voltage connection, current, leakage current, and user-defined events. There
are phase open and fuse fail events in voltage connection events. When connected to a grounded 3P3W
system, the device does not detect phase open and fuse fail events.
Current events refer to events on the current values measured by Accura 2550 modules while leakage current
events refer to events on the leakage current values measured by the 2550CMZ module. Users can configure
event detection modes, thresholds, and hysteresis values for current and leakage current events occurring
in each module on the Accura 2500D’s setup screen.
For user-defined events, users can set up input data and event detection methods via communication. Up
to 40 user-defined events are supported and can be set up with channels ranging from 1 to 40.
Accura 2500M module manages all events including events on Accura 2550 modules. Users can check event
data through the events list in the event mode on Accura 2500D module. Since RMS trend data measured
over one cycle are provided for three frames at the time an event occurs(before/when/after the event occurs),
users can conduct detailed analysis of events.
Current Events
Current events are divided into “Over” or “Under” events according to the current values measured by Accura
2550 modules at 0.2-second intervals. Users can configure threshold and hysteresis values for each 2550CM[Z]
module on the Accura 2500D’s setup screen. For details about event detection modes, refer to 「Chapter 6
Functions> Events > Measurement Events > User-Defined Events > Event Detection」.
User-Defined Events
The following figure shows the block diagram of user-defined events for a channel. A total of 40 channels
can be set up via communication. User-defined events feature “Event Input Data” related to selecting event
input data, “Event Detection” related to processing events, and “Event Notification” sections related to
notifying users of the occurrence of events.
Event Detection
Event detection modes support “Over/Under/Off” items. “Over” refers to detecting events with values greater
than “Threshold” while “Under” refers to detecting events with values smaller than “Threshold”. “Off” refers
to deactivating the event detection function.
When “Over” is selected, if an event input value exceeds the Threshold in steady state, a Pickup Event occurs.
If it remains during “Time delay”, a Start Event occurs. If the input value drops below the “Threshold –
Hysteresis” level and returns to the normal mode, an End Event occurs.
When “Under” is selected, if an event input value exceeds the “Threshold” in steady state, a Pickup Event
occurs. If it remains above the “Low Limit” level during “Time delay”, a Start Event occurs. If the input value
gets back above the “Threshold + Hysteresis” level and returns to the normal mode, an End Event occurs.
If an event input value gets smaller than the “Threshold” and drops below the “Low Limit” within “Time
delay”, a Start Event does not occur. However, if the event input value gets back to the steady state, a Start
Event occurs.
Start, End, and Pickup events are supported by default. However, users can deactivate the function to detect
pickup events only via communication.
Threshold Hysteresis
Input data
(0.2 sec data) δ
Time delay
Low Limit
Pickup signal
Start event
End event
Threshold Hysteresis
Input data
(0.2 sec data) Time delay δ
δ
δ
Low Limit
Pickup signal
Start event
End event
Event Notifications
When a user-defined event occurs, it is recorded into an event log, and the device provides users with
notifications. In case of occurrence of an event, the EVENT LED flashes, and the color of the bell icon on the
upper right side of the screen is changed.
System Events
System events include events on module controls, communication status, and setup change. System events
are recorded into event logs, and when an event requiring inspection occurs, the device provides users with
notifications through the EVENT LED.
Setup for the EVENT LED can be performed via the following menu options.
▶ Main: 「SETUP > SYSTEM > LED」
Aggregation
Accura 2500M/2550 modules perform gapless sampling of voltage and current and generate one-cycle data
for each cycle. It also aggregates the data over either 12 cycles (for 60 Hz) or 10 cycles (for 50 Hz) to
generate 0.2-second frame data. Based on the 0.2-second data(Aggregation 0), it provides data aggregated
over intervals of 1 second or longer.
For general measurement parameters including voltage, current, power, and IO modules’ analog input and
output data, Accura 2500M provides the average/maximum/minimum values, and timestamp data for the
maximum/minimum values within an aggregation interval. It enables statistical analysis of measurement data.
The average value indicates the average of the values measured for 0.2 seconds within an aggregation
interval. The maximum and minimum values indicate the maximum and minimum values among the values
measured for 0.2 seconds during the aggregation interval. The timestamp data for the maximum/minimum
values indicate the time difference between the start time of the aggregation interval and the occurrence
time of the maximum/minimum values. Therefore, the actual time data can be obtained by adding the start
time of the aggregation interval to the time difference.
For specific measurement parameters including energy, demand, and IO modules’ digital input/output data,
the device provides the data measured for the last 0.2 seconds by latching the data. It enables users to
collect accurate data measured for the last 0.2 seconds within an aggregation interval with flexibility in time.
Accura 2500M provides six fixed aggregation intervals, as well as five user-defined aggregation intervals that
enable users to set up the aggregation interval and the offset time for the start of the aggregation interval.
Fixed Aggregation
Accura 2500M provides six fixed aggregation intervals from Aggregation 1 through 6 (1 second, 5 seconds,
1 minute, 5 minutes, 1 hour, and 6 hours). For fixed aggregation intervals, the offset time for the start time
of the aggregation interval is fixed to zero. That is, the start time of the aggregation interval is set to start
at 0 hours 0 minutes 0 seconds. To set the offset time to a non-zero value, you should use the user-defined
aggregation function.
The displayed values on the LCD screen of Accura 2500D module are values measured during the 1-second
aggregation interval. The Max/Min values shown on the LCD screen are the maximum and minimum values
among the frame data obtained after resetting the max/min values, which are also provided via
communication through “Aggregation 255” setup.
User-Defined Aggregation
Accura 2500M provides 5 user-defined aggregation intervals from Aggregation 11 to 15 that allow users to
arbitrarily set up the offset time for the aggregation interval and the start time.
If the offset setting is 0, the aggregation interval starts at 0 hours, 0 minutes, 0 seconds. For example, if you
want to collect the average data during 1-hour intervals at 10 minutes of each hour, you need to select one
of the aggregation intervals from Aggregation 11 to 15, set the aggregation interval to 3,600 seconds, and
set its offset time to 600 seconds.
By selecting an aggregation interval, users can collect data on the selected aggregation interval via
communication using the Modbus map. Because the aggregated data are stored in the circular buffer in
Accura 2500M module for a certain period of time, users can collect aggregated measurement values with
greater flexibility.
The above table shows the sizes of the circular buffer for each aggregation interval. The recent circular index
can be easily identified because the circular buffer index is rotated within the range of 0 to 9,999, which is
greater than the buffer length.
Appendix A Specifications
General Specifications
Environmental Conditions
Installation location Indoors
Operating temperature -20 − 70 C (-4 − 158 ℉)
Safe operating temperature 1 -20 − 60 C (-4 − 140 ℉)
Storage temperature -40 − 85 C (-40 − 185 ℉)
Operating humidity 5 – 95 % (non-condensing)
Operating altitude Up to 2,000 m
Ingress protection against dust and water IEC 60529 IP54 (Accura 2500D)
General
Warranty period 2 years
1. Compliant with UL 61010-1(3rd edition)
connectable modules
Voltage Measurement
Voltage wiring method 3P4W, 3P3W, 1P3W, 1P2W
Sampling rate 512 samples/cycle
Measurement cycle Basic measurement Frame: 0.2 sec (12 cycles @60 Hz, 10 cycles @50 Hz)
(gapless) Dip/Swell measurement 1 cycle
Voltage Measuring range AC 35 – 347 V L-N (Line-to-neutral)
(accuracy guaranteed) AC 60 – 600 V L-L (for unearthed Delta & Y systems)
Accuracy IEC 61557-12 Class 0.5 ±0.5 % Reading
Min. measured value 5 V Line-to-neutral
Measurement data Line-to-neutral voltage, Line-to-line voltage
Fundamental voltage, harmonics (up to the 50th order) 13
Management Function
Management of Maximum number of connectable modules: 30 in a group / 40 for both groups
Accura 2550 modules Provides data on Accura 2550 modules according to the request from the host system
Automatic detection of module connection status, Assignment of module IDs
Sends the voltage data of the incoming line to multiple Accura 2550 modules
Collects measurement and operational status data from multiple Accura 2550 modules
1. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.4 Nm(14 kgf-cm, 12 lbf-in).
2. The device conforms to UL standards for the tested AC power supply voltage.
3. It refers to the maximum power consumption based on the power supply input voltage when Accura 2500D and
Accura 2550 modules are connected.
4. When installing fuses on the power line, it is recommended to use fuses that are UL-listed with an RK5 class or
higher and are rated at 2 A/500 V.
5. It is provided with the product.
6. It is provided with the product. Additional cables needed for a ring topology are sold separately.
7. The conducting wire of the communication cable should be at least 0.205 mm2 (24 AWG). It is recommended to keep
a distance of over 5 mm from the power lines generating high levels of noise.
8. It varies by the type of the connected module and the cable length between modules.
Refer to 「Appendix B Module Connection」 for details about module connection.
9. The built-in Ethernet switch enables the connection of Accura 2500M modules without the need for a separate switch.
10. FTP(Foiled Shielded Twisted Pairs), STP(Braided Shielded Twisted Pairs), SFTP(Braided Foiled Shielded Twisted Pairs)
11. RSTP(Rapid Spanning Tree Protocol), IEEE 802.1D-2004.
12. At 115,200 bps, a master can communicate with up to 16 slave devices, and the maximum distance between
the master and the slave is 600 m.
13. It is calculated with line-to-line voltage in 3P3W mode and line-to-neutral voltage in 3P4W mode.
14. The basic voltage Un is 277 V line-to-neutral voltage.
15. User-defined events can be configured only via communication.
16. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.2 Nm(12 kgf-cm, 10.6 lbf-in).
17. The max. tightening torque of the terminal screws of the barrier-type terminal block is 1.8 Nm(18.4 kgf-cm, 16 lbf-in).
Power Supply
Power supply voltage Receives power from Accura 2500M using its built-in connector or the internal
communication cable for the display module
LCD Display
LCD features 5” (108.0 x 64.8 mm) Color TFT LCD
800 x 480 pixels
LED backlight & touch panel (The LCD screen can be touched.)
LEDs
LEDs on the front POWER Power LED
EVENT Blinks when an event occurs (It can be set to be turned on.)
ETHERNET Blinks when the device communicates with the host system via
Ethernet (It can be set to be turned on.)
MODULE Blinks when Accura 2500M communicates with Accura 2550
(It can be set to be turned on.)
Buttons
Buttons on the front HOME Display mode Used to move to the main Home screen or the
measurement screen of the relevant module
SETUP Setup mode Used to move to the main Setup screen or the
Setup screen of the relevant module
EVENT Event mode Used to move to the main Event screen or the
Event screen of the relevant module
BACK Used to move to the previous screen
Connection with Accura 2500M
Integrated connection Attaches/detaches Accura 2500M to/from the back of Accura 2500D through the built-in
connector
Connection using a cable Connects Accura 2500D to Accura 2500M using the RJ45 internal communication cable
for the display module
Internal Communication with Accura 2500M
Dedicated communication Sends/receives data to/from Accura 2500M
Protocol Internal protocol
Connector type RJ45 connector (for connection with the communication cable)
Communication cable Internal communication cable for the display module 1
Measurement
Frequency 50/60 Hz
Sampling rate 256 samples/cycle
Measurement cycle Frame: 0.2 sec (12 cycles @60 Hz, 10 cycles @50 Hz)
(gapless)
Current demand Peak demand, predicted demand Demand time can be set up according to the
Power demand Peak demand, predicted demand demand subinterval value and the number of
demand subintervals
Current unbalance Measurement data Current unbalance according to the NEMA standard
Zero-sequence, negative-sequence current
unbalance
Power Quality
Current harmonics Harmonic order Up to the 50th order
THD, TDD Measurement data THD, TDD, Magnitude of each harmonic
Event
Current events Measured value RMS value measured at 0.2-sec intervals
Detection method Users can select either “Over” or “Under” item.
Leakage current Measured value RMS value measured at 0.2-sec intervals
events Detection method Users can select “Over” item.
1. Accura 2550CM-3P-5A module can be used by externally installing CTs (the secondary current rating: 5 A).
2. It is provided with the product. Additional cables needed for a ring topology are sold separately. The conducting wire
of the communication cable should be at least 0.205 mm2 (24 AWG). It is recommended to keep a distance of
over 5 mm from the power lines generating high levels of noise.
3. The data are available with Accura 2550CMZ modules with built-in ZCTs.
4. The data are available only via communication.
Power Supply
Power supply voltage Receives power through the internal communication cable
Voltage Input
Voltage input Receives sampled voltage data from Accura 2500M via communication
Current Input
Connector type Through-hole type (using cables/busbars)
Hole Dimensions/Weight Model Hole Dimensions [mm] Weight [g] CM/CMZ
Accura 2550CM[Z]-1P -250A Ø21.0 x 22.0 125 / 270
-125A Ø16.5 x 20.5 85 / 155
-100A Ø13.5 x 17.5 80 / 125
-60A Ø13.5 x 17.5 80 / 125
Display
LCD features 12 x 10 mm Customized Mono LCD, LED backlight or
13 x 18 mm Customized Mono LCD, LED backlight
Button
SET button Used to move to the measurement screen, enter the setup mode, and change settings
Connection with the Module
Dedicated communication Connects with Accura 2500M or Accura 2550 module
Protocol Internal protocol
Connector type RJ45 connector
Communication cable Internal communication cable 1
Measurement
Frequency 50/60 Hz
Sampling rate 256 samples/cycle
Measurement cycle(gapless) Frame: 0.2 sec (12 cycles @60 Hz, 10 cycles @50 Hz)
Current Model Basic Measuring Range Minimum
Current (Ib) (Accuracy Guaranteed) Measured Value
Accura 2550CM[Z]-1P -250A 250 A 5.0 A − 300 A 0.25 A
-125A 125 A 2.5 A − 150 A 0.13 A
-100A 100 A 2.0 A − 120 A 0.10 A
-60A 60 A 1.2 A − 72 A 0.06 A
Measurement accuracy IEC 61557-12 Class 0.5 ±0.5 % Reading
Measurement data RMS, Fundamental, Harmonics (up to the 50th order)
Vector diagram (phasor), waveforms
THD, TDD, Crest factor, K-factor
Leakage current 2 Measuring method Measured by the built-in ZCT
Measuring range 1 mA – 2 A
Measurement data RMS, Fundamental
Fundamental current CMZ-1P-250A ±0.5% Reading ± 30 mA
measurement accuracy CMZ-1P-125A/100A/60A ±0.5 % Reading ± 20 mA
Operating range Up to 120 % Ib of phase current
Current demand Peak demand, predicted Demand time is determined by the demand subinterval
demand value and the number of demand subintervals.
Power demand Peak demand, predicted
demand
Power Quality
Current harmonics Harmonic order Up to the 50th order
THD, TDD Measurement data THD, TDD, Magnitude of each harmonic
Events
Current events Measured value RMS value measured at 0.2-sec intervals
Detection method Users can select either “Over” or “Under” item.
Leakage current events 2
Measured value RMS value measured at 0.2-sec intervals
Detection method Users can select “Over” item.
1. It is provided with the product. Additional cables needed for a ring topology are sold separately.
The conducting wire of the communication cable should be at least 0.205 mm2 (24 AWG).
It is recommended to keep a distance of over 5 mm from the power lines generating high levels of noise.
2. The data are available with Accura 2550CMZ modules with built-in ZCTs.
3. The data are available only via communication.
Measurement
Frequency 50/60 Hz
Sampling rate 256 samples/cycle
Measurement cycle (gapless) Frame: 0.2 sec (12 cycles @60 Hz, 10 cycles @50 Hz)
Current Model Basic Measuring Range Minimum
Current (Ib) (Accuracy Guaranteed) Measured Value
Leakage current Measuring method Measured by the built-in ZCT of Accura 2550ZM
Measuring range 1 mA − 2 A
Measurement data Fundamental, RMS
Fundamental current ±0.5 % Reading ± 10 mA
measurement accuracy 3
Current/Power demand Peak demand, predicted Demand time can be set up according to the demand subinterval
demand value and the number of demand subintervals
Current unbalance Measurement data Current unbalance according to the NEMA standard
Zero-sequence, negative-sequence current unbalance
Power Quality
Current harmonics Harmonic order Up to the 50th order
THD, TDD Measurement data THD, TDD, Magnitude of each harmonic
Digital Input: Available with Accura 2550ZM Module
Connector type SMW250-03D (2.50 mm pitch connector)
Channel/Port name 2 channels / DI 1 DI2 DIG (isolation between channels)
Communication cable length 50 cm (provided with the product)
Input type Internal DC 5 V power supply (self-excitation), isolation between channels
Minimum pulse width 100 msec
Event
Current events Measured value RMS value measured at 0.2-sec intervals
Detection method Users can select either “Over” or “Under” item.
Leakage current events Measured value RMS value measured at 0.2-sec intervals
Detection method Users can select “Over” item.
1. It is provided with the product. Additional cables needed for a ring topology are sold separately.
The conducting wire of the communication cable should be at least 0.205 mm2 (24 AWG).
It is recommended to keep a distance of over 5 mm from the power lines generating high levels of noise.
2. The split-core CMS module has been calibrated under the condition where the power line passes through
the top center position of its hole. As the location of the power line is away from the top center position of the hole,
errors in current, power, and energy measurements can increase by up to 1 %.
3. To ensure accurate measurements of leakage current when wiring the 3P4W leakage current measuring module,
you should put together all four power lines and make them pass through the center of its hole.
4. The data are available only via communication.
Measurement
Frequency 50/60 Hz
Sampling rate 256 samples/cycle
Measurement cycle (gapless) Frame: 0.2 sec (12 cycles @60 Hz, 10 cycles @50 Hz)
Current Model Basic Measuring Range Minimum
Current (Ib) (Accuracy Guaranteed) Measured Value
Accura 2550CMS-1P3F-60A 60 A 3.0 A − 72 A 0.24 A
Energy Active Measurement 2 IEC 62053-21 Class 0.5 Received/delivered active energy
Reactive accuracy IEC 62053-24 Class 1 Reactive energy in 4 quadrants
Apparent IEC 61557-12 Class 0.5
Power factor Power factor per feeder, Displacement power factor per feeder 3
Current/Power demand Peak demand, predicted Demand time can be set up according to the demand subinterval
demand value and the number of demand subintervals
Power Quality
Current harmonics Harmonic order Up to the 50th order
THD, TDD Measurement data THD, TDD, Magnitude of each harmonic
Digital Input: Available with Accura 2550ZM Module
Connector type SMW250-03D (2.50 mm pitch connector)
Channel / Port name 2 channels / DI1 DI2 DIG (isolation between channels)
Communication cable length 50 cm (provided with the product)
Input type Internal DC 5 V power supply (self-excitation), isolation between channels
Minimum pulse width 100 msec
Event
Current events Measured value RMS value measured at 0.2 sec intervals
Detection method Users can select either “Over” or “Under” item.
Leakage current events Measured value RMS value measured at 0.2 sec intervals
Detection method Users can select “Over” item.
1. It is provided with the product. Additional cables needed for a ring topology are sold separately.
The conducting wire of the communication cable should be at least 0.205 mm2 (24 AWG). It is recommended to keep
a distance of over 5 mm from the power lines generating high levels of noise.
2. The split-core CMS module has been calibrated under the condition where the power line passes through
the top center position of its hole. As the location of the power line is away from the top center position of the hole,
errors in current, power, and energy measurements can increase by up to 1 %.
3. The data are available only via communication.
Measurement
Frequency 50/60 Hz
Sampling rate 256 samples/cycle
Measurement cycle (gapless) Frame: 0.2 sec (12 cycles @60 Hz, 10 cycles @50 Hz)
Current Model Basic Measuring Range Minimum
Current (Ib) (Accuracy Guaranteed) Measured Value
Accura 2550CMM[Z]-3P-60A 60 A 1.2 A − 72 A 0.06 A
Measurement accuracy 2 IEC 61557-12 Class 0.5 ±0.5 % Reading
Measurement data RMS, Fundamental, Harmonics (up to the 50th order)
Vector diagram (phasor), waveforms
THD, TDD, Crest factor, K-factor
Symmetrical components (positive-, negative-, zero-sequence
components)
Unbalance according to symmetrical components/
the NEMA standard
Residual current (RMS, Fundamental)
3
Leakage Current Measuring method Measured by the built-in ZCT
Measuring range 1 mA − 2 A
Measured data RMS, fundamental
Accuracy ±0.5 % Reading ± 10 mA
Operating range Up to 120 % of phase current Ib
Current/Power demand Peak demand, predicted Demand time can be set up according to the demand
demand subinterval value and the number of demand subintervals
Power Quality
Current harmonics Harmonic order Up to the 50th order
THD, TDD Measurement data THD, TDD, Magnitude of each harmonic
Digital Input
Connector type SMW250-03D (2.5 mm pitch connector)
Channel/Port name 2 channels / DI1 DI2 DIG (isolation between channels)
Communication cable length 50 cm (provided with the product)
Input type Internal DC 5 V power supply (self-excitation), isolation between channels
Minimum pulse width 100 msec
Event
Current events Measured value RMS value measured at 0.2-sec intervals
Detection method Users can select either “Over” or “Under” item.
Leakage current events Measured value RMS value measured at 0.2-sec intervals
Detection method Users can select “Over” item.
1. It is provided with the product. Additional cables needed for a ring topology are sold separately.
The conducting wire of the communication cable should be at least 0.205 mm2 (24 AWG).
It is recommended to keep a distance of over 5 mm from the power lines generating high levels of noise.
2. The data are available only via communication.
3. It is only supported in Accura 2550CMMZ module.
Connecting Accura 2500M module to multiple Accura 2550 modules causes the following limitations.
1) Limitation in the length of the communication cable due to voltage drops
2) Limitation in the number of connectable modules due to power consumption
3) Limitation in the number of connectable modules in a group: up to 30 modules
Therefore, check connectivity of modules in advance using the 「Power Supply/Communication Cable
Simulator for Accura 2500/2550」 provided separately for connection of multiple Accura 2550 modules with
different current consumption values. Before connecting modules, you can select the length of each
communication cable, the module type, and the number of connectable modules. If a limitation in connecting
modules occurs due to voltage drops or different power consumption, a warning window appears to inform
users that modules cannot be connected under the selected condition.
The entire communication cable length in a group is up to 50 m, and each cable should be up to 10 m.
However, the voltage drop on the cable caused by power consumption of Accura 2550 modules can limit
the cable length and the number of connectable Accura 2550 modules.
It is recommended to connect a module with high power consumption close to Accura 2500M when
connecting multiple Accura 2550 modules. It is because it causes less voltage drop on the communication
cable, enabling users to connect more modules.
The following table shows the power consumption for different types of Accura 2550 modules.
Accura 2500M’s power source supplies power up to 15 W based on the output voltage of 5 V. Its power
consumption is up to 7 W. Thus, when connecting modules, you should refer to the power consumption of
each module to ensure that the total power consumption of connected modules does not exceed 8 W.
The table below shows the number of connectable Accura 2550 modules when the cable length between
the port on Accura 2500M and the first Accura 2550 module is 3 m, and the cable length between the rest
of the modules is 10 cm, 20 cm, or 30 cm in a single group. Even though the total power consumption of
connected modules does not exceed 8 W, up to 30 Accura 2550CM[Z] modules can be connected in a single
group. The following table shows the number of connectable Accura 2550 modules decreases when
connecting modules with higher power consumption.
Note
Check connectivity of modules in advance using the Power Supply/Communication Cable Simulator for
Accura 2500/2550 provided separately for connection of multiple Accura 2550 modules with different
power consumption values.
Connection using a single port (No Ring) Connection using two ports (No Ring) Connection using two ports (Ring)
The two ports used in a single group as shown in the above figure have the same functions. A ring topology
enables communication redundancy, which enhances communication reliability.
When it is not possible to connect Accura 2500M to all Accura 2550 modules in a single group, connect the
modules that can be connected in a single group and then connect Accura 2500M to the rest of the modules
using ports in the other group. Up to 40 Accura 2550 modules can be connected to Accura 2500M using
ports in two groups.
Appendix C Standards
Measurement Accuracy
IEC61557-12 Power metering and monitoring devices (PMD)
IEC62053-21 Static meters for AC active energy (classes 0.5, 1 and 2)
IEC62053-22 Static meters for AC active energy (classes 0.1S, 0.2S and 0.5S)
IEC62053-24 Static meters for fundamental reactive energy (classes 0.5S, 1S, 1, 2 and 3)
Power Quality
IEC 61000-4-30 Power quality measurement methods
Safety
UL 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use
EMC
EN 55011 Conducted emissions
EN 55011 Conducted emissions (asymmetric mode)
EN 55011 Radiated emissions
IEC 61000-3-2 Limits for harmonic current emissions
IEC 61000-3-3 Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply
systems
IEC 61000-4-2 Electrostatic discharge(ESD) immunity test
IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4 Electrical fast transient/burst immunity test
IEC 61000-4-5 Surge immunity test
IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8 Power frequency magnetic field immunity test
IEC 61000-4-11 Voltage dips, short interruptions and voltage variations immunity test
Certifications
UL UL 61010-1 3rd edition, UL 61010-2-030 2nd edition
CE EN 55011:2009/A1:2010, EN IEC 61326-1:2021, EN IEC 61326-2-1:2021,
EN IEC 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021
KC EN 55011:2009/A1:2010, EN IEC 61326-1:2021, EN IEC 61326-2-1:2021
PMD Dx PMD Sx
80 %Un – 120 %Un 5 %Ib – 10 %Ib 2 %In – 5 %In 1.0 ±1.25 % ±2.5 %
10 %Ib – Imax. 5 %In – Imax. 1.0 ±1.0 % ±2.0 %
10 %Ib – 20 %Ib 5 %In – 10 %In 0.5 ±1.25 % ±2.5 %
20 %Ib – Imax. 10 %In – Imax. 0.5 ±1.0 % ±2.0 %
0.25 ±1.25 % ±2.5 %
PMD Dx PMD Sx
80 %Un – 120 %Un 5 %Ib – 10 %Ib 2 %In – 5 %In ±1.0 %
10 %Ib – Imax. 5 %In – Imax. ±0.5 %
Frequency
Voltage Range Current Range Frequency Class 0.02
PMD Dx PMD Sx
50 %Un – Umax 20 %Ib – Imax. 10 %In – Imax. 45 – 55 Hz ±0.02 %
55 – 65 Hz
RMS Voltage
Voltage Range Min. Bandwidth (Harmonic) Crest Factor Class 0.5
Power Factor
Voltage Range Current Range Power Factor Class 0.5
PMD Dx PMD Sx
0.8 capacitive
1. There is no unit for the value.
IEC 62053-21:2020 Static Meters for AC Active Energy (Classes 0.5, 1 and 2)
IEC 62053-22:2020 Static Meters for AC Active Energy (Classes 0.1S, 0.2S and 0.5S)
IEC 62053-24:2020 Static Meters for Fundamental Reactive Energy (Classes 0.5S, 1S, 1, 2 and 3)
Appendix D Accuracy/Reliability
Accuracy
Accura 2550CM[Z] modules meet measurement accuracy within the range broader than the measuring
range required for the IEC 61557-12 standard as shown in the table below.
Reliability
Wiring Modes
MAINS systems and nominal voltages Line-to-neutral
Three-phase Three-phase Three-phase Single-phase Single-phase voltage pertinent
four-wire systems three-wire systems three-wire systems two-wire systems (split-phase) to MAINS system
three-wire systems type and nominal
With earthed Unearthed With earthed voltage
neutral phase
V V V V V V
220/380 220, 230, 240 200 240/440 220 300
230/400 260, 277, 347 240/480 230
240/415 380, 400, 415 240
260/440 440, 480
277/480
Refer to 「Chapter 6 Functions > Measurements > Voltage Wiring」 for details about auxiliary connections for
voltage sensing.
Accura 2500M Main Industrial Control Panel Module/Accura 2500D Main Industrial Control
Panel HMI Module
Name Option Description
Accura 2500M -AC220V/DC110V Main industrial control panel module AC 100 – 240 V, DC 100 – 300 V
-DC24V DC 20 – 30 V
Accura 2500D Industrial control panel HMI module
Special-Purpose Modules
Name Description
Accura -500V-80A Basic voltage 500Vdc/ Basic current 80 Adc
2550DCM -50V-80A Basic voltage 50Vdc/ Basic current 80 Adc
Accura 2550TEMP Measures the external temperature of the panel where the module is installed
Accura TSEN Collects data on the temperature measured in the panel where it is installed
Accura THSEN Collects data on the temperature and humidity measured in the panel where it is installed
Accura 2550GW Collects data from peripheral devices supporting RS-485 communication
Accura 2550GWM Collects data from peripheral devices supporting RS-485 communication with its 4 ports
Accura 2550SAL-3P-DO Measures the leakage current of the surge arrester
Accura 2550VOL Measures the voltage of multiple power supplies
Accura 2550IO -DI1 11 DI channels
-DI2 22 DI channels
-DO1 6 DO channels
-DO2 12 DO channels
-AI1 6 AI channels (DC 4 – 20 mA)
-AI2 12 AI channels (DC 4 – 20 mA)
-RTD1 4 channels, RTD temperature sensor input
-RTD2 8 channels, RTD temperature sensor input
Accura 2550PS Used for additional power supply
User Guide
Rootech Inc.
88 Sinwon-ro, Yeongtong-gu, Suwon, Gyeonggi-do, Korea
(102-611 Digital Empire 2)
Tel. +82-31-695-7350
Fax. +82-31-695-7399
www.rootech.com
[email protected]
Accura 2300/2350, Accura 2300S/2350, Accura 2300S/2350-1P3FSC, Accura 2500/2550, Accura 2700/2750, Accura 3000,
Accura 3300E, Accura 3500/3550/3500E, Accura 3700, Accura 5500, and Accura 7500 are trademarks of Rootech Inc. Contact
us for detailed product specifications and ordering information. Information contained herein is subject to change without
notice. CopyrightⓒRootech Inc. Printed In Korea