GENERAL INFORMATION
ITEM DESCRIPTION SPECIFICATION QTY UNIT RATE AMOUNT REMARKS
Procure, Supply, Fabricate, paint approved steel works in line
with the steel steel sections as provided in the drawings, ITT and
other issued documents with all associated fittings, tools,
consumables and accessories. Fabrication is to be by
predominantly site connections as shown on the various
Structural Engineer's Drawings.
Base plate ; Face plate
300 x 300 x 10mm thick; with 4Nos 18mm
1 (Supply, Fabricate, paint and 20 No 0
diameter holes
install)
2 Stanchion C1 HE250A; 76.35kg/m 5813.289 Kg 0
3 Stanchion C2 HE250A; 76.35kg/m 3036.82125 Kg 0
4 Stanchion C3 HE250A; 76.35kg/m 1814.076 Kg 0
5 Beam, IPE 400; 66,3kg/m 3222.18 Kg 0
800mm long; Sliced IPE 400 angular
Beam Stiffners (Haunch type
6 section x 140 x 10mm thick; with all 716.04 Kg 0
1)
associated welds and drillings
754 x 280 x 20mm thick; with all associated
Face plate (Supply,
7 welds and drillings for 8Nos of 22mm 18 No 0
Fabricate, paint and install)
diameter holes for M20 bolts
8 Beam, Slab section IPE 300; 42,2kg/m 3502.6 Kg 0
1.5mm thick, grade 280, Galvanised
Supply, Fabricate, paint and
Corrugated sheet for rib deck E60 for CFD3
install Galvanised Galvanised and
9 composite slab deck (all corrugation, 135 m2 0
Corrugated steel sheet for corrugated steel
lapping and associated waste should be
deck
considered in the rate)
1.5mm thick, grade 280, Corrugated steel
Supply, Fabricate, paint and sheet for rib deck E60 for CFD3 composite
9a install Corrugated metal slab deck measured net (all corrugation, 135 m2 Optional quote Corrugated steel
sheet for deck lapping and associated waste should be
considered in the rate)
19mm Diameter, 103mm high share
connector in CFD3 composite deck slab at
19mm Diameter share
10 330mm centres welded through the steel 260.0 No 0
connector
plate to the IPE 300 (see the picture in the
comment section)
Face plate (Supply, 300 x 150 x 10mm thick; with all associated
11 34 No 0
Fabricate, paint and install) welds and drillings
12 Roof Beam, Upper IPE 240; 30,7kg/m 2333.2 Kg 0
240 x 120 x 10mm thick; with all associated
13 Face plate 28 No 0
welds and drillings
14 Roof Fascia 50 x 25mm x 5mm Angle iron 508.08 Kg 0
15 Roof trusses bracing 50 x 50 x 5mm Angle iron for cross bracing 537.6 Kg 0
6m long, 12mm diameter sag rod with 2No.
16 Sag rod 48 No 0
threaded ends and 2No nuts
17 Roof Rafters IPE 300; 42,2kg/m 4810.8 Kg 0
720mm long; Sliced IPE 300 angular
Stifner section (Haunch type
18 section x 195mm with all associated welds 474.75 Kg 0
2)
and drillings
540 x 280 x 20mm thick; with all associated
Face plate (Supply,
19 welds and drillings for 10Nos of 22mm 24 No 0
Fabricate, paint and install)
diameter holes for M20 bolts
868mm long; Sliced IPE 300 angular
Stifner section (Haunch type
20 section x 230mm with all associated welds 217.752 Kg 0
3)
and drillings
Stiffner plate; Face plate
224 x 136 x 10mm thick; with all associated
21 (Supply, Fabricate, paint and 64 No 0
welds and drillings
install)
Face plate (Section E); Face 575 x 280 x 20mm thick; with all associated
22 plate (Supply, Fabricate, welds and drillings for 8Nos of 22mm 8 No 0
paint and install) diameter holes for M20 bolts
Face plate (Section F); Face 575 x 280 x 20mm thick; with all associated
23 plate (Supply, Fabricate, welds and drillings for 6Nos of 22mm 20 No 0
paint and install) diameter holes for M20 bolts
Face plate (Section G); Face 575 x 280 x 20mm thick; with all associated
24 plate (Supply, Fabricate, welds and drillings for 8Nos of 22mm 12 No 0
paint and install) diameter holes for M20 bolts and nuts
Z-Purlins (Roof and Wall
25 202 x 60 x 1.8mm thick; Z purlins 3460.896 Kg 0
cladding)
130 x 190 x 10mm steel cleat with all
Cleat; Face plate (Supply, associated welds and drillings for 4Nos of
26 140 No 0
Fabricate, paint and install) 14mm diameter holes for M12 bolts and
nuts
130 x 190 x 10mm steel cleat with all
Purlins ends Cleat; Face
associated welds and drillings for 2Nos of
27 plate (Supply, Fabricate, 116 No 0
14mm diameter holes for M12 bolts and
paint and install)
nuts
Stairs
Allow for steel staircase, 2Nr flights in
All structural steel works are
1Nr staircase; Supply, fabricate, apply 3
galvanized and fabrication is
coats of approved specified paint in ITT
to be by predominantly site
28 and install complete steel stairs with 1 No 0 See the drawings
connections as shown on the
complete steel beam, steps, risers,
various Structural Engineer's
galvanised grating, handrail and associated
Drawings.
fittings/accessories.
Bolts
29 M 12 diameter bolts and nuts 764 No 0
30 M 20 diameter bolts and nuts 664 No 0
M16 diameter, 420mm long, holding down
31 Anchor bolt bolts, threaded at bot ends with 4Nos nuts MTCC Exclusion
& washers per bolt
32 A253 fabric mesh MTCC Ditto
33 Grout MTCC Ditto
Complete installation with tools and
On site installation 30,448.08 Kg 0
accessories
GENERAL SUMMARY OF
0
FIRE STATION