0% found this document useful (0 votes)
159 views5 pages

Batching Plant Calibration

batching plant calibration details
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
159 views5 pages

Batching Plant Calibration

batching plant calibration details
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 5
RADING INSTRUMENTATION & CALIBRATION SOLUTION aye SHRIT ISO/IEC 17025:2017 & ISO 91 015 CERTIFIE! Mob : 9420267582, 9665499654 CALIBRATION CERTIFICATE CortiReate No + STICS/928/01 Calibration Date + 24-10-2024 Date of Certificate: 28-10-2024 Recomm. Due Date + 23-01-2025 Page No. ofS ‘Name of Customer ‘SUBHASH INFRAENGINEERS PVT. LTD, Address 2X 800 MW NTPC LARA, STAGE Il, DisT.:- RAIGARH (C.G3- 496440 Description & Mdentification of DUC Name BATCHING PLANT (AGGREGATE) Make/Model MACONS/CP-30 [Range 1000 kg [Calibration Parameter lweicnr [Sr.No 707000324000295 [Least Count ‘kg [Condition on Receipt lox faNo. ‘SIPL/BP-A/O1 Location SITELAB [Calibration Performed At ONSITE Environment Condition Calibration Procedure No ‘Temp /Humiaty 262% 52 RIL ‘STICS/SOP/M/35 based on IS: 4925:2004 Details of Standard / Master Equipment Used ‘Nomendaure SENG: ‘Class | _ Certificate No Validity Calibrated By WEIGHT 1616/1619) i PL2L 11-01-2026. PRECIMASS LLP PRECISION BALANCE | 210402, T PL-1027 10-03-2025, TPRECIMASS LLP Siandard Weight Loading Tatoading Sr.No. on te to Mean Error z 0, 0 ° wo ow z 20 a9 19 190 526 3 0 39 39 39.0 256 * 60 3 39 590 169 5 80 7 79 73.0 127 6 100 9 99 99.0 Zor 7 0 iy Tis 1190 oat 3 140 9 139 139.0 072. 9 360 159 159 159.0 063, To 80 79 179 1790 056 i 200. 199. 199 199.0 050, 12 220 219 219 2190 046 | 13 240 239 239 2390 042. 4 260. 259 259 2590 039) 15 280 279 279 2790 036, 16 300 299 299 29900 033 17 320 319 319 3190 031 ie 340 339 339 3390 029 19 360 359 359 3590 028 20 380 379 379 3790 026 2 400 399 399 3990 025, m2 420 419 419 4190 O28 23 440 459 339 4390 023) 2 460 459 450 ro a2 25 480 479 479 47904 02 Calibrated By z ‘Appro wa IGADE JAYSING! WAR (CALIBRATION ENGINEER) CEO) mene ‘Vijaypath Nagar, Plot No. 20 S.No. 66, Near ip ingineering Collage, Amravati - 444607 (M.S.) India vaehieasomest ene ae ial ca © [email protected], [email protected] © ‘www sticscalibration.com SpyZ> SHIRE TRAGING INSTRUMENTATION & CALIBRATION SOLUTION <8 ISO/IEC 17025:2017 & ISO 9001:2015 CERTIFI ED LAB Mob : 9420267582, 9665499654 CALIBRATION CERTIFICATE Certificate No, smies/238/01, Calibration Date; 24-10-2024 Date of Certificate: 28-10-2024 Rocomm.DuaTnts + 22.01.2075 Page No. 1 20fS Description & Mdentification of DUC Rome [BATCHING PLANT (AGGREGATE) [Make/Model [ MACONS/CP-30__[Range 1000 kg [Calibration Parameter lweicnT se No, 1107000324000295 — |Leart ca kg _[Gondition on Receipt lox ano. SIPL/BP-A/01 [Location SITELAB [Calibration Performed at [ONSITE Tnviroament Condition Calibration Procedure No ‘Temp/Humiany | 262°C 52 Ri STICS/SOP/M/35 based on IS: 4925:2004 (TION. ‘Standard Weight Loading Taloading Sr.No, a ms cq) Mean Error 26 500 499 490 a a0 a7 520 519 519 5190 019 2a 540 539 539 53900 019 29 360 559. 550 5590 048 30 580 379) 379 5790 a7 31 600 599 399 599.0 017 32 620 619 619 190 016 33 640 639 639 6390 036 34 660 659) 659 659.0 (045 35 60 679 0 6790 (045 36 700 699 69 699.0 oe 37 720 79 719 7190 oi 3 740. 739 739 739.0 ou 39 760 759 759 759.0 013, 40 780 779 779 7790 ois a a 259 733) oom vas ‘a2 820 a9 19 2190 012 4 840 839 39 838.0 O12 4 60 259 358 959.0 az rg oo 879 39 879.0 oat 46 900 399 899 399.0 oun @ 920 919 319 919.0 our a 340 939 939. 939.0 oir 49 360 959 959 959.0 00 50 00 379 379 979.0 010 51 1000 999) 999 999.0 030) ‘AVERAGES OF ERROR] 06 (Remarks 1) The reported expanded uncertainty is at coverage factor K=2 which corresponds toa coverage probability of approximately 95 % for a normal distribution. 2) Certjcates shall not be reproduced except in ful without the written approval of STICS. 13) Results relate only tothe tems calibrated, \s) DUC: Device Under Calibration 5} Results are traceable to the National Seandards Calibrated By bettie meme ‘ijaypath Nagar, Plot No. 20 S.No. 66 fear sini ovis © stisamtm@ gmail.com, [email protected] © www sticscalibation.com Calibratinn Earilitioe Availahie Ear Machenies! Clacten tank; Sa oe oy SHRI TRADING INSTRUMENTATION & CALIBRATION SOLUTION ISO/IEC 17025:2017 & ISO 9001:2015 CERTIFIED LAB Mob : 9420267582, 9665499654 CALIBRATION CERTIFICATE Certificate No. + STICS/238/01 Calibration Date 24-10-2024 Date of Certificate + 28-10-2024 Recomm. Due Date 23-01-2025 Page No. 3015 ‘Name of Customer SUBHASH INFRAENGINEERS PVT. LTD, Address 2X 800 MW NTPC LARA, STAGE I DisT.- RAIGARH (C.6,)- 496440 Description & Mentification of DUC ame ‘BATCHING PLANT (CEMENT) IMake/ Model | MACONS/CP-30___[Range '300 kg [calibration Parameter lwelGnT. sro. 107000324000295 [Least Count ‘01 kg [Condition on Receipt lox id No. SIPL/BP-C/01__ [Location SITELAB [calibration Performed at [ONSITE Tavironment Condition ‘Calibration Procedure No ‘Temp/Humidity | 262% 52 94RH ‘STICS/SOP/M/35 based on IS: 4925:2004 Details of Standard / Master Equipment Used ‘ROMERO SER Class Cerificate No ala Calibrated By ‘WEIGHT 1M i_[-Scw.0823-176 71-05-2025 MARUTI WEIGHTECT ‘WEIGHT Te1e/icio | F PLL 101-2026 PRECIMASS LLP PRECISION BALANCE [2104029 T PLL0zt 10-05-2025) PRECIMASS LLP dard Weight Loading Unloading Sr.No a ‘Can i Mean Error, z 0 00. 00. m0 00 z 20, 195 195, 195, 256, 3 40 00) 00 400. 0.00 1 60 60.0 600 6000 (0.00 a 80 80.0 300 800. 0.00 é 1007 700.0 O00 ow o.0. 7 120 1205 200 1203 oar @ 40. 740.0 7400 1400 0.0 2 0 700 fs ae00 000 0.00. 10 380 180.0 1800 700 0.00 i 200. 2005) 2005 2005 025, 12 220. 2200) 2200 2200 0.00, 13 240 2405 2405 2405 024 14 260 2600) 2605 2605 0.0) 15 a0 2A05. 20's 2005 038. 16 300 3005. 300.0 3003 008. AVERAGE OF ERROR] 0.10 [Remarks 1) The reported expanded uncertainty Is at coverage actor Ra2 which corresponds to a coverage probability of approximately 95 % for a normal distribution. 2) certsiates shail not be reproduced execpt in full without the writen approval of STICS. |3) Results relate only tothe items caltrated. |4) DUC: Device Under Calibration la Resuts uve rveuble ty he Nutvnal Standard Calibrated By Mattie (CALIBRATION ENGINEER) ‘anew 086s = [email protected], [email protected] © www-sticscalibration.com Prete re, = — 2yZ SHRITRADING INSTRUMENTATION & CALIBRATION SOLUTION ISO/IEC 17025:2017 & ISO 900° 15 CERTIFIED LAB Mob : 9420267582, 9665499654 CALIBRATION CERTIFICATE. Certificate No. smics/236/01 Calibration Date 2410-2024 Date ofertineate ; 26-10-2024 Recomm.DueDate ; 23-01-2025 Page No. 40s Name of Customer SUBHASH INFRAENGINEERS PVT.LTD, Adress 2X80 MW NTPCLARA, STAGE Hl, DIST RAIGARH (CG.)- 496440, Deseripon & Wenicaion of DUC Name [BATCHING PLANT (WATER) Naka/ Modal | MACONS7¢P-20 [Raven 200 kg [Calibration Parameter [wecnr sno. 7107000524000295 — [Least Count ‘0.1 kg [Condition on Receipt OK a, SIPL/BP-W/01_ [Location SITELAB ——[Caioraon Performed'at [ONSITE Environment Condition Galbration Procedure No Temp/ttamiaty | 262 % 52 96 STICS/SOP/M/3 based on iS: 4925:2008 ‘Derails of Standard / Master Equipment Used Nomendature Seo Glass | Certfiate No Validity Taliated By WEIGHT si F| —Scw-0593-176 H-05-2025 THARUT WEGHTEGH WEIGHT Ta19/16i9—| FL PLaL TI01-2026, PRECINASS LLP TRECISION BALANCE | — 2104029 —[ —1 PL-1027 10-03-2025 PRECINASS CLF as ‘andard Weight Toading Taoading = aaa, bi? se) (sg) (sg) bs Z 0 00 00 ° 200 2 20 200 200 200 000 3 40 405 200 403 er} 4 Cy 00 600 600 200 3 80 735 200 738) 031 6 100 1000 1005 3003 025 7 120 1200 1205 1203 “oat @ 10) 1395 1900 3398 010 9 160 1595 1600 1598 016 rn 100 1795 1800 98 O16 aw 200 1995 2000 1998 013 "AVERAGE OF ERROR] _-002 marks: 1) The reported expanded uncertainty sa coverage factor R=Z WHI Corresponds oa coverage probably of approvimately 95% fora narmal distribution, a) certificates shall not be reproduced except in ful without the written approval of TICS. Ls) tests relate only tothe tems callraed. ls Duc: Device Under Calibration s} Rests are traceable to the National Standards librated By |GADE (CALIBRATION ENGINEER) (SME _—_iaynath nagar, plot No. 205.No, 66, near Stpna Engineering Collage, Amravati - 444607 (MS, India eines ones, s [email protected], [email protected] © wwwsticscallbration.com pelle caet eT tel ie a SHRI TRADING INSTRUMENTATION & CALIBRATION SOLUTION O/IEC 17025:2017 & ISO 9001:2015 CERTIFIED LAB Mob : 9420267582, 9665499654 CALIBRATION CERTIFICATE Certificate No, sries/239/01 Calibration Date: 24-10-2024 Page No. 1 Sols Name of Customer SUBHASH INFRAENGINEERS PVT. LTD, dass 2800 MW NTPC LARA, STAGE DIST.- RAIGARH (CG)-496840 Description & Wentiication of DUC ame [BATCHING PLANT (ADMEXTURE) Make” Model | _MACONSYCP-30 [Range 5000 g [Calibration Parameter lwercar sna. 107000324000295 [least Coane 10g [Gondiion on Receipt lox. iano ‘SIPL/BP-A/01——[tocton SHTELAB —— |Cabration rertormed At ON SITE Tivifonment Condon Callration Procedure No ‘Temp/Atamidity [262% 52 sR STICS/S0P/1/35 based on 5: 49252004 Datalls of Standard / Master Equipment Used Romendaare ‘SeNa——[ dass | Cortese No ‘valli Calibrated By weit M FL | ~ScW-0525-176 TH05-2005 TMARUTY WEIGHTECH PRECISION BALANGE | 2104029, 1 Pint024 10-03-2025 PRECINASS LLP (TION RE = ‘Slandard Weight Loading Taloading as sr ma a r Error 1 500 500 00 5000 200 2 1000 1000 1000 10000 0.00 a 1500 1500 1500 15000 000 ‘ 2000) 2000 2005 2002s an s 2500 2500 2500 25000 00 6 3000 3000 3000 ‘30000 00 7 3500 3500 3500 35000 000 @ 4000 4005 4005, 40080 01 5 4500 4500 4500 45000 200 10 5000 000 5000 0000 00 AVERAGE% OF ERROR] -0.02 [Remarks I) The reported expanded uncertainty ia overage Tatar Red which corresponds to a coverage probabiigy of approximately 9 % fora nrmal dration 2) cerficats shall not be reproduced except in ful without the written approval fSTIC. 3) Results relate only to the tems calibrated 1) DUC: Device Under Calibration 5) Results ar traceable wo the National Standards Calibrated By svesititcaon (cuulmearion swan MSMZ —_viaypath nagar, riot no.208 ‘avant a

You might also like