Calibration certificate

Certificate no. 180 Date 29/11/24


Rig serial no. - Time 10:07:08
Rig type Mobile Flow Lab Application version 2.2.0.9
Application name EH Calibration v2.2.0.9.fxa
"===============================================================================
METER DATA

Calibrated meter UUT


Model PROMASS 63
Serial no. OP429242
Manufacturer Endress Hauser
Tag FIT-07-011
Calibrated output Analog Non-Ex active

4 mA value 0.000 kg/h


20 mA value 5000.000 kg/h

"===============================================================================
CALIBRATION SETTINGS

Measuring range 0-5000 kg/h


Calibration range 1680-3360 kg/h
Calibration fluid Water
No. of set points 3
No. of repeats 3
Deviation unit % reading

Uncertainty unit % reading


"===============================================================================
SET POINT 1

Master meter used Master meter 2 - DN25


Flow rate 1680.0000 kg/h
Serial no. ---

Uncertainty 0.300000 %

Ref. Ref. UUT


Run flow rate Time value value Deviation
kg/h s kg/h kg/h %
1 1603.2012 31.5000 1603.2012 1594.2014 -0.561
2 1553.1098 32.5004 1553.1098 1546.6454 -0.416
3 1551.1942 32.5002 1551.1942 1544.6369 -0.423
4 - - - - -
5 - - - - -
6 - - - - -
Average 1569.1684 32.1669 1569.1684 1561.8279 -0.467

Ambient Fluid Ref. UUT Line


Run temp. temp. pulses current press.
°C °C mA bar(g)
1 27.98 40.54 28056.001 9.101 1.56
2 28.06 40.65 28042.622 8.949 1.57
3 28.03 40.77 28007.828 8.943 1.57
4 - - - - -
5 - - - - -
6 - - - - -
Average 28.03 40.66 28035.484 8.998 1.57
"===============================================================================
SET POINT 2

Master meter used Master meter 2 - DN25


Flow rate 2520.0000 kg/h
Serial no. ---

Uncertainty 0.300000 %

Ref. Ref. UUT


Run flow rate Time value value Deviation
kg/h s kg/h kg/h %
1 2451.3555 30.9997 2451.3555 2440.8562 -0.428
2 2333.4989 32.4993 2333.4989 2319.9174 -0.582
3 2292.6353 33.0005 2292.6353 2282.7109 -0.433
4 - - - - -
5 - - - - -
6 - - - - -
Average 2359.1632 32.1665 2359.1632 2347.8281 -0.481

Ambient Fluid Ref. UUT Line


Run temp. temp. pulses current press.
°C °C mA bar(g)
1 28.02 41.24 42217.381 11.811 1.33
2 28.11 41.35 42131.649 11.424 1.37
3 28.15 41.46 42032.310 11.305 1.38
4 - - - - -
5 - - - - -
6 - - - - -
Average 28.09 41.35 42127.113 11.513 1.36
"===============================================================================
SET POINT 3

Master meter used Master meter 2 - DN25


Flow rate 3360.0000 kg/h
Serial no. ---

Uncertainty 0.300000 %

Ref. Ref. UUT


Run flow rate Time value value Deviation
kg/h s kg/h kg/h %
1 3402.5690 29.9999 3402.5690 3386.0994 -0.484
2 3379.0937 30.0002 3379.0937 3362.0213 -0.505
3 3366.6831 29.9999 3366.6831 3351.4752 -0.452
4 - - - - -
5 - - - - -
6 - - - - -
Average 3382.7819 30.0000 3382.7819 3366.5320 -0.480

Ambient Fluid Ref. UUT Line


Run temp. temp. pulses current press.
°C °C mA bar(g)
1 28.19 41.81 56709.222 14.836 1.03
2 28.12 41.92 56318.595 14.758 1.04
3 28.24 42.03 56111.173 14.725 1.05
4 - - - - -
5 - - - - -
6 - - - - -
Average 28.18 41.92 56379.664 14.773 1.04
"===============================================================================
SET POINT 4

Master meter used


Flow rate 9000.0000 kg/h
Serial no.

Uncertainty -

Ref. Ref. UUT


Run flow rate Time value value Deviation
kg/h s kg/h kg/h %
1 - - - - -
2 - - - - -
3 - - - - -
4 - - - - -
5 - - - - -
6 - - - - -
Average - - - - -

Ambient Fluid Ref. UUT Line


Run temp. temp. pulses current press.
°C °C mA bar(g)
1 - - - - -
2 - - - - -
3 - - - - -
4 - - - - -
5 - - - - -
6 - - - - -
Average - - - - -
"===============================================================================
SET POINT 5

Master meter used


Flow rate 0.0000 kg/h
Serial no.

Uncertainty -

Ref. Ref. UUT


Run flow rate Time value value Deviation
kg/h s kg/h kg/h %
1 - - - - -
2 - - - - -
3 - - - - -
4 - - - - -
5 - - - - -
6 - - - - -
Average - - - - -

Ambient Fluid Ref. UUT Line


Run temp. temp. pulses current press.
°C °C mA bar(g)
1 - - - - -
2 - - - - -
3 - - - - -
4 - - - - -
5 - - - - -
6 - - - - -
Average - - - - -
"===============================================================================