Types of Air Conditioning Systems and
Suitable Choice for Your Home
Enhance room comfort with the air conditioner that best matches the interior.
For reliable operation and design, Mitsubishi Electric is the logical choice.
Single Split
■ Suitable for
· Small residences like studio apartments
· Homes with floor area of 20m2-50m2
· Installing additional units if required
TABLE OF CONTENTS
■ MXY series 7
■ MXZ series 25
Installation Image
3
LINE-UP
NEW RELEASE NEW RELEASE
MXY-H SERIES INVERTER Cooling Only Models Indoor Unit For MXY-H SERIES
Capacity
Model Name Capacity class (Min.-Max.) Model Name 1.5kW 2.0kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW
MSZ/MSXZ-LN Series
Up to 2 indoor units
5.0kW (1.3kW-6.5kW)
MXY-2H50VF
Wall-
mounted
MSXY-JS Series
Up to 3 indoor units
6.5kW (1.3kW-8.3kW)
MXY-3H65VG
MLZ-KP Series
Up to 4 indoor units 1-way
7.6kW (1.3kW-8.9kW) cassette
MXY-4H76VG
SEZ-M Series
Compact
Up to 4 indoor units
9.2kW (1.4kW-11.2kW) ceiling-
MXY-4H92VG concealed
Up to 5 indoor units
10.5kW (1.4kW-13.0kW)
MXY-5H105VG
MXZ SERIES INVERTER Heat Pump Models Indoor Unit For MXZ SERIES
Capacity
Model Name Capacity class (Min.-Max.) Model Name 2.2kW 2.5kW 3.5kW 4.2kW 5.0kW 6.0kW 7.1kW
MSZ-GE Series
Up to 2 indoor units Wall-
5.3kW (1.1kW-5.6kW)
MXZ-2D53VA2 mounted
SEZ-KD Series
Compact
Up to 3 indoor units
6.8kW (2.9kW-8.4kW) ceiling-
MXZ-3E68VA concealed
Up to 4 indoor units
8.3kW (3.7kW-9.2kW)
MXZ-4E83VA
Up to 5 indoor units
10.2kW (3.9kW-11.0kW)
MXY-5E102VA
Up to 6 indoor units
12.2kW (3.5kW-13.5kW)
MXZ-6D122VA2
4
New Released MXY-H series features
Expanded line-up for cooling only model
We are introducing additional line-up of MXY-3H65VG(6.5kW with 3-port) and MXY-5H105VG(10.5kW with 5-port).
It is ideal if you are looking to cool a bigger room in your home.
Capacity class 5.0kW 6.5kW (NEW) 7.5kW 9.2kW 10.5kW (NEW)
Previous R410A Model 2-port - 3-port/4-port 4-port -
New R32 Model 2-port 3-port 4-port 4-port 5-port
*R410A Model : MXY-2E20VA/3A28VA/4A28VA/4A38VA
4.5 4.35
4.20 4.34
4 3.76 3.79
2.5
2
5.0kW(2-port) 6.5kW(3-port) 7.5-7.6kW(4-port) 9.2kW(4-port) 10.5kW(5-port)
R410A MXY-A/E series R32 MXY-H series
NEW
More compact & Lighter Design for 9.2kW class
Compact design fits into narrow outdoor unit space of condominiums.
Light weight design facilitates easy installation.
MXY-4A38VA MXY-4H92VG
11%
reduction
Height Height
900mm 796mm
14%
796mm
900mm
reduction
Weight Weight
67kg 57kg
NEW NEW
Operating at high temperatures (52 ) Blue fin condenser
New Inverter technology has made it possible for units to operate A special coating is applied to the heat exchanger to increase
at an outdoor air temperature as high as 52 . corrosion toughness.
Operating range
New models
Conventional models
5
New Indoor units for MXY-H series
Wide range of indoor units
A multiple series line-up to choose from each with various outstanding features.
It has made it possible to match usage needs.
Wall-mounted 1-way cassette Compact ceiling- concealed
NEW MSZ/MSXZ-LN series NEW MSXY-JS series NEW MLZ-KP series SEZ-M series
Dust, PM2.5
Dirty Air
Viruses Bacteria
Mold Allergens
1st stage
• Make plasma.
• Break mold and allergens.
Wire Wire Inhibit viruses.
• Dust and PM2.5 given
an electrical charge (+).
2nd stage
• Make a strong electrical field.
• The charged dust and PM2.5 (+)
are absorbed in the strong
electrical field (-).
Clear air
Powerful Cool
)
Air Outlet Temperture (
Nomal Operation
Comfortable temperature
can be reached in less time.
Time
6
MXY-H
SERIES
R32
Cooling Only
7
SELECTION
Choose from three types of indoor units and three types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.
MSZ/MSXZ-LN
MSXY-JS(15-35)
MSXY-JS(60-71)
Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Check Indoor Unit Capacity Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit
Combination selected is connectable. (Combinations not listed cannot be connected.)
If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.
8
Cooling Only
MXY R32
SERIES
Our Inverter Technology adjusts capacity in response to conditions such as
the difference between the outside and inside air temperatures, allowing
Outdoor
Unit
our air conditioners to run more efficiently and reduce energy costs.
EXAMPLE SYSTEM
MSZ/MSXZ-LN
MSXY-JS
MSXY-JS
MLZ-KP
MXY-5H105VG
SEZ-M
9
Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit MXY-
MSZ-LN13VF
MSZ-LN35VF
MSZ-LN10/13/18VFR
MSZ-LN25/35VFR
MSZ-LN18VF
MSXZ-LN25VFR
<Onyx Black>
MSXY-JS15VF
MSZ-LN10/13/18VFB
MSZ-LN25/35VFB
<Pearl White>
MSXY-JS20VF
MSXY-JS25VF
MSZ-LN10/13/18VFV
MSZ-LN25/35VFV
MSXY-JS35VF
MSXY-JS15/20/25/35VF
MSXY-JS50VF
MSXY-JS60VF
MSXY-JS50VF
MSXY-JS71VF
MSXY-JS60/71VF
MLZ-KP25VF
1-way cassette
MLZ-KP35VF
SEZ-M25DA(L)
Ceiling-concealed
SEZ-M35DA(L)
SEZ-M50DA(L)
SEZ-M60DA(L)
SEZ-M71DA(L)
10
MSZ-LN25/35VF
MSZ-LN10/13/18VF
MSXZ-LN
MSXZ-LN25VF
MSZ-LN SERIES
Developed to complement modern interior room décor, the LN Series is
available in three colours specially chosen to blend in naturally wherever
installed. Not only the sophisticated design, but also operational comfort
add even more value to this series.
Master craftsmanship painting technology has resulted in a refined Pearl White blends in with any interior.
design, giving the finish deep colour and a premium quality feel.
Ruby Red gives an accent to the room, affording timeless elegance to Onyx Black matches darker interiors, creating a comfortable environment.
sophisticated interiors.
Sensor with
eight elements
Even Airflow
Normal swing mode Even airflow mode
8 × 94 areas
Sensor measures while
moving to the left to right
Divided into 94
The airflow is distributed equally throughout The 3D i-see sensor memorizes human move-
(Image) the room, even to spaces where there is no ment and furniture positions, and efficiently
human movement. distributes airflow.
The “3D i-see Sensor” detects people’s absence and the power consumption is automatically
reduced approximately 10% after 10 minutes and 20% after 60 minutes.
12
Plasma Quad Plus is a plasma-based filter system that effectively removes six kinds of air pollutants. Plasma Quad Plus captures mold and
allergens. It can also capture PM2.5 and particles smaller than 2.5µm, creating healthy living spaces for all.
Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad
Plus neutralizes 99% of bacteria in 162 minutes Plus neutralizes 99% of virus particles in 72 Plus neutralizes 99% of mold in 135 minutes in
in a 25m3 test space. minutes in a 25m3 test space. a 25m3 test space.
<Test No.> KRCES-Bio. Test Report <Test No.> vrc.center, SMC <Test No.> Japan Food Research Laboratories
No. 2016-0118 No. 28-002 Test Report No. 16069353001-0201
In a test, air containing cat fur and pollen was Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad
passed through the air cleaning device at the Plus removes 99% of PM2.5 in 145 minutes in Plus removes 99.7% of dust and mites.
low airflow setting. Before and after measure- a 28m3 test space.
ments confirm that Plasma Quad Plus neutraliz-
es 98% of cat fur and pollen.
<Test No.> ITEA Report No. T1606028 <In-company investigation> <Test No.> ITEA Report No. T1606028
Dust, PM2.5
Dirty Air
Viruses Bacteria
Mold Allergens
1st stage
• Make plasma.
• Break mold and allergens.
Wire Wire Inhibit viruses.
• Dust and PM2.5 given
an electrical charge (+).
2nd stage
• Make a strong electrical field.
• The charged dust and PM2.5 (+)
are absorbed in the strong
electrical field (-).
Clear air
13
A two-barrier coating prevents dust and greasy dirt from getting into the air conditioner.
Dual Barrier
Coating is used for
• Heat exchanger
• Fan
• Air duct
Fan
Air duct
No dual barrier coating (image after 10 years) Dual barrier coating used
The inside of the indoor unit gets dirty after many years of usage.
Heat exchanger Fan Consequences when the inside
New 10 years later (image) New 10 years later (image) of the indoor unit is left dirty.
• Deterioration in energy
efficiency.
• Musty smell from the unit.
14
Double Flap
The vanes create various airflows to make each person in the room comfortable. Not only the horizontal vanes, but also the vertical vanes move
independently, eliminating hot spots or cold spots throughout the room.
Quiet Operation
The indoor unit noise level is as low as 19dB for LN25/35 models, offering a peaceful inside environment.
● Noise Level
Quiet passenger Human
Subway car car interior Sound of hearing limits
Library interior
interior (40km/h) rustling leaves (Extremely quiet)
15
MSXZ-LN
MSZ-LN SERIES
Indoor Unit / Remote Controller
MSZ-LN10/13/18VFR MSZ-LN10/13/18VFV
MSZ-LN25/35VF MSZ-LN25/35VFV
MSXZ-LN25VFRR
<Onyx Black>
MSZ-LN10/13/18VFB
MSZ-LN25/35VFB
Back Light
Remote
Type Cooling
Model Name MSXZ-LN25VF MSZ-LN25VF MSZ-LN35VF MSZ-LN10VF MSZ-LN13VF MSZ-LN18VF
Power Supply Source Outdoor Power Supply
Air Volume /min 4.3 - 5.9 - 4.3-5.8- 4.3-5.8- 4.3-5.8- 4.3-5.8- 5.7-7.6-
Quiet-Lo- 7.2 - 8.9 - 12.0 7.1-8.8-11.9 7.1-8.8-11.9 7.1-8.8-11.9 7.1-8.8-11.9 8.8-10.6-13.9
Cooling 1
Sound Level Med-Hi-SHi*
dB(A) 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 27 - 31 - 35 - 39 - 46
(SPL)
Operating Current (max.) A 0.16 0.21 0.21 0.21 0.21 0.28
Dimensions H x W x D mm 307 x 890 x 233 307 x 890 x 233 307 x 890 x 233
Weight kg 15.5 15.5 15.5 15.5 15.5 15.5
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7
*1SHi : Super High * The lineup differs by region.
16
MSXY-JS15/20/25/35VF
MSXY-JS50VF
MSXY-JS SERIES
MSXY-JS60/71VF
JS Series features advanced technology developed worldwide through many years of experience. We have achieved powerful
cooling with high energy efficiency to bring you optimal comfort. Moreover you can select the indoor unit with many advantages
which covers with wide range of cooling capacity.
New Design
MSXY-JS15/20/25/35VF MSXY-JS50VF
MSXY-JS60/71VF
Powerful Cool
Push the Powerful Cool button when you need to cool down quickly, such as when you return home on a hot day, or when you have
guests over.
Powerful Cool
Comfortable temperature
can be reached in less time.
Powerful
Cool
Sleep mode
Approx.
120 mins
17
Auto Vane Control*Up and Down/Left and Right *Only for JS50/60/71
Auto vanes can be moved left and right, and up and down using the remote controller.
SWING
SWING
Wing
B Flap
Cross Flow Fan
Our unique Cross Flow Fan construction guides air smoothly along each rotating wing as it simultaneously intakes and expels air. This
allows for highly efficient delivery of powerful and refreshing airflow.
PM2.5
Dirty Clean
air air
18
A two-barrier coating prevents dust and greasy dirt from getting into the air conditioner.
Dual Barrier repels both types of dirt Comparison of dirt on Heat exchanger, Fan and Air duct
Hydrophilic Hydrophobic
dirt dirt
19
MLZ-KP25/35VF
MLZ SERIES
Introducing a new type of ceiling cassette for the
Multi-Split Series with streamed interior dimen-
sions and a sharp, sleek appearance. 2017
Slim Design
Industry leading slim body realized a simple design with linear beauty.
20
Auto Vane Control Horizontal Airflow
Outlet vanes can be moved left and right, and up and down using The new airflow control completely eliminates that uncomfortable
the remote controller. This improved airflow control feature solves drafty-feeling with the introduction of a horizontal airflow that spreads
the problem of drafts. across the ceiling. The ideal airflow for offices and restaurants.
[Horizontal Airflow]
Model name: MLZ-KP35VF
Ceiling height: 2.4m
Model: Cooling
3.0 4.0
2
1.0 0.5
Height (m)
1
• Start by pushing the “SET” button and follow the instructions to set the desired patterns.
Once all of the desired patterns are input, point the top end of the remote controller at the
indoor unit and push the “SET” button one more time. (Push the “SET” button only after in-
putting all of the desired patterns into the remote controller memory. Pushing the “CANCEL”
button will end the set-up process without sending the operation patterns to the indoor unit).
• It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit.
Please continue to point the remote controller at the indoor unit until all data has been sent.
21
Easy Installation
Industry leading Slim Body
Inovative size which enables to fold the refrigerant piping above
the unit. Industry leading
185 mm
Dimension: 185(H)×1102(W)×360(D)mm
Secure one side Push the unit to one side Move unit to the centre
Secure the opposite side
Drain piping
Air Purifying
Electrostatic Weekly
Anti-allergy Timer
Optional Optional
Type Cooling
Model Name MLZ-KP25VF MLZ-KP35VF
Power Supply Source Outdoor Power Supply
Operating Current (max.) A 0.4 0.4
Air Volume /min 6.0 - 7.2 - 8.0 - 8.8 6.0 - 7.3 - 8.4 - 9.4
SLo-Lo-Med-Hi
Indoor Sound Level (SPL) dB(A) 27 - 31 - 34 - 38 27 - 32 - 36 - 40
Unit Dimensions HxWxD mm 185 × 1,102 × 360 185 × 1,102 × 360
Weight kg 15.5 15.5
Dimensions HxWxD mm 24 × 1,200 × 424 24 × 1,200 × 424
Panel
Weight kg 3.5 3.5
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52
*Panel : MLP-444W
22
SEZ SERIES SEZ-M25/35/50/60/71DA with wired Remote Controller
SEZ-M25/35/50/60/71DAL with wireless Remote Controller
This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.
SEZ-M35DA(L)
Optional
Type Cooling
Model Name SEZ-M25DA(L) SEZ-M35DA(L) SEZ-M50DA(L) SEZ-M60DA(L) SEZ-M71DA(L)
Power Supply Source Outdoor Power Supply
Air Volume /min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0
Cooling Lo-Med-Hi
Sound Level (SPL) dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40
External Static Pressure Pa 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50
Operating Current (max.) A 0.39 0.46 0.63 0.63 0.84
Dimensions HxWxD mm 200 × 790 × 700 200 × 990 × 700 200 × 990 × 700 200 × 1,190 × 700 200 × 1,190 × 700
Weight kg 17.5 21 22 25.5 8
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88
23
24
MXZ R410A
SERIES
Heat pump
25
SELECTION
Choose from three types of indoor units and five types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.
Wall-mounted Ceiling-concealed
MSZ-GE(22/25/35/42/50)
SEZ-KD
MSZ-GE(60/71)
MXZ-5E102VA MXZ-6D122VA2
Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Check Indoor Unit Capacity Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit
Combination selected is connectable. (Combinations not listed cannot be connected.)
If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.
26
MXZ
Outdoor
Unit
R410A
SERIES
Heat pump
EXAMPLE SYSTEM
MXZ-6D122VA2 MSZ-GE
MSZ-GE
MXZ-6D122VA
SEZ-KD
Chargeless Length m 20 40 40 25 0 30
Guaranteed Operating Range Cooling oC –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46
[Outdoor] Heating oC –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24
*1: If the outdoor unit is installed higher than the indoor unit, max height is reduced to 10m.
27
Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit MXZ-
MSZ-GE22VA
Wall-mounted
MSZ-GE25VA
MSZ-GE(22/25/35/42/50) MSZ-GE35VA
MSZ-GE42VA
MSZ-GE(60/71) MSZ-GE50VA
MSZ-GE60VA
MSZ-GE71VA
SEZ-KD25VAL
Ceiling-concealed
SEZ-KD35VAL
SEZ-KD50VAL
SEZ-KD60VAL
SEZ Series
SEZ-KD71VAL
28
MSZ-GE22/25/35/42/50VA
MSZ-GE60/71VA
MSZ-G SERIES
The standard model MSZ-G units provide excellent energy savings and operation is impressively quiet. A vast series line-up is ready
to ensure comfortable room environments in response to your air conditioning needs.
25-35
Wide Line-up
Only
Quiet Operation 19dB
Seven different indoor units (Model 22-71) are available to meet A “Quiet Mode” setting has been added to the fan speed settings,
your diversified air conditioning needs. ensuring super-quiet operation below 20dB for model sizes 35 and
under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.
MSZ-GE22/25/35/42/50VA MSZ-GE60/71VA
This filter incorporates nanometre-sized platinum-ceramic particles
that generate stable antibacterial and deodourising effects. The size
Stylish and Compact of the three-dimensional surface has been increased as well, enlarg-
An elegant, high-quality look is achieved through the new stylish ing the filter capture area. These features give the Nano Platinum
design adopted for indoor units. The simple ergonomic square shape Filter of the MSZ-GE60/71 models better dust collection perfor-
and pure white color express a sense of sophistication that matches mance than conventional filters. The superior air-cleaning effective-
well with virtually any interior décor. ness raises room comfort yet another level.
800mm
Electrostatic Nano
Anti-allergy Platinum
Optional Optional
4C/5C/6C 4C/5C/6C
Optional
29
30
SEZ SERIES SEZ-KD25-71VAL
This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.
SEZ-KD35VAL
Optional
31
External Dimensions
MXY SERIES
MXZ SERIES Unit : mm
MXY-2H50VF MXY-3H65VG
MXZ-2D53VA2 MXZ-3E68VA
OUTDOOR UNIT OUTDOOR UNIT
169 500 171
400
Drain hole 65.4 207.5 314
17.7
Air in Air
34
Inlet
44
18.3
304 325
16.6
344.5
(Bolt Pitch)
360.6
Air in
396
17.5
Air Inlet
12.3
40 Air
17.7
3- ø33 Drain hole Outlet
Air out
4-10x21 Oval Hole
2-10x21 Oval hole (Foundation Bolt M8)
10 840 30
200 25.8 330 12.5
handle
Connecting
wire hole
66
240
550
710
Liquid pipe
251.1
280
A unit
LIQ
Gas pipe connection Unit C
GAS
LIQ LIQ ø6.35(1/4")FLARE
Unit B
360
GAS GAS ø9.52(3/8")FLARE
LIQ
302.5 170.4
10
Unit A
GAS
150 500
800 69 299
MXY-4H76VG MXY-4H92VG
MZY-4E72VA MXZ-4E83VA
OUTDOOR UNIT OUTDOOR UNIT
Air 51.4
2×U SHAPED NOTCHED HOLE
Inlet (FOUNDATION BOLT M10)
34
16
36
62
40
16.6
10
(Bolt Pitch)
360.6
396
10
(BOLT PITCH)
Air Inlet
134
12.3
370
417
10
10
31
AIR 10
51
DISCHARGE
4-10x21 Oval Hole 2×12×36 OVAL HOLE
(Foundation Bolt M8) (FOUNDATION BOLT M10)
Handle 950
10 840 30
25 330 15
200
25.8 330 12.5
HANDLE HANDLE
Connecting
wire hole
240
66
70
AIR INTAKE
796
LIQ
710
Unit D LIQ
GAS UNIT D
LIQ
GAS
Unit C LIQ ø6.35(1/4")FLARE
GAS ø9.52(3/8")FLARE LIQ LIQ Ø6.35(1/4")FLARE
GAS UNIT C
GAS GAS Ø9.52(3/8")FLARE
LIQ
407
Unit B LIQ
360
GAS UNIT B
GAS
LIQ LIQ ø6.35(1/4")FLARE LIQ LIQ Ø6.35(1/4")FLARE
Unit A GAS ø12.7(1/2")FLARE UNIT A
GAS GAS GAS Ø12.7(1/2")FLARE
299
361
32
MXY SERIES MXZ SERIES Unit : mm
MXY-5H105VG MXZ-6D122VA2
MXZ-5E102VA OUTDOOR UNIT
OUTDOOR UNIT
Air in
175 600 175
71 250 80 97 116 2-U Shaped Notched Hole
(Foundation Bolt M10)
51
10
36
16
62
10
40
134
(Bolt pitch)
370
417
Air in
10
6-ø33 Drain Hole
10
10 10
31
51
Air out
950 25 330 15
Handle
Handle
Handle
70
Liquid pipe : Ø6.35(flared)1/4 F unit
Gas pipe : Ø9.52(flared)3/8 connection
1048
Liquid pipe : Ø6.35(flared)1/4 E unit
Gas pipe : Ø9.52(flared)3/8 connection
Liquid pipe : Ø6.35(flared)1/4 D unit
Gas pipe : Ø9.52(flared)3/8 connection
Liquid pipe : Ø6.35(flared)1/4 C unit
Gas pipe : Ø9.52(flared)3/8 connection
563
Liquid pipe : Ø6.35(flared)1/4 B unit
Gas pipe : Ø9.52(flared)3/8 connection
Liquid pipe : Ø6.35(flared)1/4 A unit
Gas pipe : Ø12.7(flared)1/2 connection
Air Intake
361
33
Piping Installation
MXY SERIES MXZ SERIES
MXY-2H50VF MXZ-2D53VA2
Maximum Piping Length Indoor a Maximum height
units difference
Outdoor unit - Indoor unit (a,b) 20m
Total length (a+b) 30m
Outdoor Outdoor unit
Outdoor unit
|
Indoor unit
b 10m
*Outdoor unit
installed higher
MXY-3H65VG MXZ-3E68VA
Maximum Piping Length
Highest
Outdoor unit - Indoor unit (a,b,c) 25m Indoor Maximum height
units a
Total length (a+b+c) 60m difference
c Indoor unit
10m
*Outdoor unit
installed higher
MXY-4H76VG MXZ-4E72VA
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d) 25m Indoor
Total length (a+b+c+d) 60m units Highest Maximum height
a difference
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c,d) 25 Outdoor
b
Total number (a+b+c+d) 60 unit Outdoor unit
|
Indoor unit
15m
*Outdoor unit
installed lower Indoor unit
|
c Indoor unit
MXY-4H92VG MXZ-4E83VA 15m
Maximum Piping Length
Outdoor unit
Outdoor unit - Indoor unit (a,b,c,d) 25m Lowest d
|
Indoor unit
10m
Total length (a+b+c+d) 70m *Outdoor unit
installed higher
34
MXZ-5E102VA
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e) 25m Indoor
Highest Maximum height
Total length (a+b+c+d+e) 80m units difference
a
Highest
Indoor e Maximum height
MXZ-6D122VA2 units
a difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25m
Outdoor
Total length (a+b+c+d+e+f) 80m b unit Outdoor unit
|
Indoor unit
15m
Maximum Number of Bends c *Outdoor unit
installed lower Indoor unit
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25 |
Indoor unit
Outdoor unit
Lowest
|
Indoor unit
10m
d f
*Outdoor unit
installed higher
35
External Dimensions
Wall-Mounted Unit : mm
MSXY-JS15/20/25/35VF MSZ-LN10/13/18VF MSZ-LN25/35VF MSXZ-LN25VF
INDOOR UNIT INDOOR UNIT
838
5
228
DRAIN HOSE
57
42
43
100
64 57 40
100
AIR OUT 170.5
179
58 19
159
MSXY-JS50VF MSZ-GE22/25/35/42/50VA
INDOOR UNIT INDOOR UNIT
923 798
785 6.5
7 909
5
262
AIR IN
Air in
INSTALLATION PLATE
232
PIPING 5
(53) 709 161 Installation plate
DRAIN HOSE Piping
18.5
100
295
65
100
8
65
69
56
65 65 116.5 42 Drain hose
AIR OUT
53
63
71
50 619 130
93
133 107
112
175.5 Air out
58 19 58 19
159
159
MSXY-JS60/71VF MSZ-GE60/71VA
INDOOR UNIT INDOOR UNIT
1100 1100
1090 5 1090 5
Piping
325
Piping
325
67
67
12
12
100
100
65 65
3
58 19 60 18
193
159
36
4-way cassette Unit : mm
MLZ-KP25/35/VF
INDOOR UNIT
37
Ceiling-concealed Unit : mm
SEZ-KD25/35/50/60/71VAL
INDOOR UNIT 20 157.5
15 12 37 100 37
88
B (Suspension bolt pitch)
100X(E-1)=F
100XJ=K
D (Duct)
H
C
A
Air Air
outlet inlet
100
100
88
30
57
20
20
12
10 23 L- 2.9
2XE- 2.9
25
90
102
150 (Duct)
170
100
200
SEZ-M25/35/50/60/71DA
SEZ-M25/35/50/60/71DAL
INDOOR UNIT
20 157.5
15 12 37 100 37
88
B (Suspension bolt pitch)
100X(E-1)=F
100XJ=K
D (Duct)
H
C
A
Air Air
outlet inlet
100
100
88
30
57
20
20
12
25
10 L- 2.9
23
2XE- 2.9
90
102
150 (Duct)
170
100
200
38
INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance, including the optimum control of operation frequency. As a result,
optimum power is applied in all cooling/heating ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and amazingly low running cost — That’s the Mitsubishi Electric promise.
ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter-equipped air conditioners. We have combined advanced inverter technologies
with cutting- edge electronic and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling
performance efficiency. As a result, better performance and lower energy consumption are achieved.
TRUE COMFORT
Below is a simple comparison of air conditioner operation control with and without an inverter.
consumption
temperature
Preset
Preset
ON OFF ON OFF ON
The compressors of air conditioners without an inverter start and stop repeatedly in order to maintain the preset room temperature.
This repetitive on/off operation uses excessive electricity and compromises room comfort. The compressors of air conditioners
equipped with an inverter run continuously; the inverter quickly optimizing the operating frequency according to changes in room
temperature. This ensures energy-efficient operation and a more comfortable room.
39
MORE ADVANTAGES WITH MITSUBISHI ELECTRIC
Joint Lap DC Motor Vector-Wave Eco Inverter
Mitsubishi Electric has developed a unique motor, This inverter monitors the varying compressor motor frequency and
called the “Poki-Poki Motor” in Japan, which is creates the most efficient waveform for the motor speed. As the
manufactured using a joint lapping technique. result, operating efficiency in all speed ranges is improved, less
This innovative motor operates based on a high- power is used and annual electricity cost is reduced.
density, high-magnetic force, leading to extremely Smooth wave pattern
Sine-wave drive soft PWM
high efficiency and reliability.
Inverter size has been reduced using insert-
molding, where the circuit pattern is molded into
the synthetic resin. To ensure quiet operation,
soft PWM control is used to prevent the metallic
Magnetic Flux Vector Sine Wave Drive whine associated with conventional inverters.
Time
DC compressor Neodymium Current Time
motor ( rotor ) magnets
PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
Magnetic torque
+ ■ Merits of PAM Control Power increased
Reluctance torque Efficient voltage increase
realises increased power
Significant energy savings PAM
Remarkable reduction in power
Heat Caulking
Fixing Method Heat Caulking Fixing Method loss saves electricity Conventional
inverter
To fix internal parts in place, a “Heat Caulking
Fixing Method” is used, replacing the former arc Limited power
spot welding method. Distortion of internal parts Limited energy savings Insufficient power
Electricity is wasted when needed
is reduced, realising higher efficiency.
Heat Compressor
exchanger
Power Heat
receiver exchanger
LEV1 LEV2
40
FUNCTIONS (1)
3D i-see SENSOR
Area Temperature Monitor
Cooling mode
The “3D i-see Sensor” monitors the whole room in sections
and directs the airflow to areas of the room where the tempera- Warmer Cooler
Daytime Nighttime area
area
ture does not match the temperature setting. (When cooling the
room, if the middle of the room is detected to be hotter, more
airflow is directed towards it.) This eliminates unnecessary
heating /cooling and contributes to lower electricity costs.
ENERGY-SAVING
Econo Cool Energy-Saving Feature Econo Cool Mode
A comfortable room environment is maintained even when setting the
“Econo Cool” is an intelligent temperature control feature that adjusts temperature 2°C higher than the conventional cooling mode.
the amount of air directed towards the body based on the air-outlet Econo Cool on Conventional cooling mode
temperature. The setting temperature can be raised by as much as
2°C without any loss in comfort, thereby realising a 20% gain in
energy efficiency. (Function only available during manual cooling operation.)
Conventional Econo Cool
Ambient temperature 35°C 35°C
Set temperature 25°C 27°C
Perceived temperature 30°C 29.3°C Temperature distribution (°C)
14 16 18 20 22 24 26 28
AIR QUALITY
Nano
Plasma Quad Plus Platinum Nano Platinum Filter
Plasma Quad Plus is a plasma-based filter system similar to Plasma The filter has a large capture area and incorporates nanometre-sized
Quad, but in addition to bacteria, viruses, allergens, and dust, it can platinum-ceramic particles that work to eliminate bacteria and de-
also filter out microparticles such as PM2.5. odourise the circulating air.
Dual Barrier
Coating Dual Barrier Coating Micro Particle
Catching Micro Particle Catching Filter
A two-barrier coating which prevents hydrophobic and hydrophillic The filter effectively catches floating PM2.5 particle to maintain
dirt from sticking to the inner surface and inner parts of the indoor clean air in the room.
unit.
41
AIR DISTRIBUTION
Horizontal Vane High Ceiling Mode
The air outlet vane swings up and down so that the airflow is spread In the case of rooms with high ceilings, the outlet-air volume can be
evenly throughout the room. increased to ensure that air is circulated all the way to the floor.
Powerful Cool
Once activated, powerful cool mode continues for 15 minutes cooling
starts immediately with the push of a button.
CONVENIENCE
On/Off Operation Timer
Use the remote controller to set the times of turning the air conditioner On/Off.
Sleep Mode
Once activated, this mode slightly lowers temperatures to support body to release heat, and auto matically returns to original setting temperatures
after 120 minutes.
42
FUNCTIONS (2)
CONVENIENCE
Built-in Weekly Timer Function
Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
■ Example Operation Pattern (Winter/Heating mode)
Mon. Tues. Wed. Thurs. Fri. Sat. Sun.
ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C
Automatically changes to high-power operation at wake-up time
Back Light
Remote
Back Light Remote Controller
Not only the indoor units, but the wireless remote controllers come in four colours as well. Each remote controller
matches the indoor unit. Even the textures are the same.
43
INSTALLATION
Wiring/Piping Correction Function*
The push of a single button is all that is required to confirm that Wiring
confirmation
piping and wiring are properly connected. Corrections are made au- is time
The outdoor unit
matches
tomatically if a wiring error is detected, eliminating the need for com- consuming. pipes and wiring.
MAINTENANCE
Easy Clean
The cover panel can be quickly removed for washing and the airflow vents can be opened without any special tools, making it easy to clean the
inside of the air conditioner in minutes. Periodic cleaning of the air conditioner is recommended to maintain optimum operating efficiency and
energy savings.
BLUE
FIN Blue Fin condenser
A special coating is applied to the heat exchanger to increase
corrosion toughness.
44
FUNCTION LIST Indoor unit
MSZ-LN (10/13/18, 25/35)
Category MSXZ-LN (25)
Outdoor Unit MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H
DC Inverter
Joint Lap DC Motor
Reluctance DC Rotary Compressor
Technology Heating Caulking (Compressor)
DC Fan Motor
PAM (Pulse Amplitude Modulation)
Grooved Piping
Felt Temperature Control (3D i-see sensor)
i-see sensor
AREA Temperature Monitor
Energy-Saving Econo Cool
Plasma Quad Plus
Dual Barrier Coating
Electrostatic Anti-allergy Enzyme Filter
Air Quality
Micro Particle Catching Filter
Anti-allergy Enzyme Filter
Nano Platinum Filter
Powerful Cool
Horizontal Vane
Vertical Vane
Air Distribution
High Ceiling Mode
Auto Fan Speed Mode
Functions
Long Airflow (12m)
On/O Operation Timer
"i save" Mode
Auto Restart
Convenience Low-noise Operation (Outdoor Unit)
Sleep Mode
Ampere Limit Adjustment
Built-in Weekly Timer Function
Wiring/Piping Correction Function
Installation Drain Pump
Flare Connection
Self-Diagonosis Function (Check Code Display)
Maintenance Failure Recall Function
Blue-Fin condenser
MSZ-GE (22/25/35/42/50/60/71)
Indoor unit
Category
Outdoor Unit MXZ-2D MXZ-3E MXZ-4E MXZ-5E MXZ-6D
DC Inverter
Joint Lap DC Motor
Reluctance DC Rotary Compressor 83
Heating Caulking (Compressor)
Technology
DC Fan Motor
PAM (Pulse Amplitude Modulation)
Power Receiver and Twin LEV Control 72
Grooved Piping
Energy-saving Econo Cool Energy-saving Feature
Anti-allergy Enzyme Filter Opt22-50 Opt22-50 Opt22-50 Opt22-50 Opt22-50
Electrostatic Anti-allergy Enzyme Filter Opt60/71 Opt60/71 Opt60/71 Opt60/71
Air Quality
Catechin Filter 22-50 22-50 22-50 22-50 22-50
Nano Platinum Filter 60/71 60/71 60/71 60/71
Horizontal Vane
Vertical Vane 60/71 60/71 60/71 60/71
Air Distribution
Auto Fan Speed Mode
Wide and Long Airflow 60/71 60/71 60/71 60/71
On/O Operation Timer
"i save" Mode / Smart Set
Auto Changeover *1 *1 *1 *1 *1
Functions
Auto Restart
Convenience Low-temperature Cooling
Low-noise Operation (Outdoor Unit)
Ampere Limit Adjustment 83
Operation Lock
Built-in Weekly Timer Function
Wiring/Piping Correction Function
Installation Drain Pump
Flare Connection
Easy Clean
Maintenance Self-Diagonosis Function (Check Code Display)
Failure Recall Function
*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.
45
MSXY-JS (15/20/25/35/50/60/71) MLZ-KP (25/35) SEZ-M (25/35/50/60/71)
MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H
SEZ-KD(25/35/50/60/71)
83
72
*1 *1 *1 *1 *1
83
46
Doing Our Part to
Create a Better Future for All...
Core Environmental Policy
The Mitsubishi Electric Group promotes sustainable development and is committed to protecting and restoring the global
environment through technology, through all its business activities, and through the actions of its employees.
R410A R32
*1 Source: IPCC 4th Assessment Report, global warming potential (GWP) 100-year value.
Comparison of 2088 (R410A) and 675 (R32).
47
R32 REFRIGERANT
a) Leakage Ignition
b) Concentration c) Ignition
*5 source
Although R32 is classified as low flammability, the possibility of igniting can be eliminated by ensuring the following three points.
b) Prevent concentration.
·Ventilate during installation and servicing, such as open the door or window and use a fan.
·Follow “2. Installation Restrictions”.
Note Both R32 / R410A emit a toxic gas when coming into contact with an open flame.
48
Reliability
Facts
Always Quality First
Cutting-edge technologies and uncompromising commitment to quality and reliability have made
Mitsubishi Electric one of the world’s most trusted brands in air-conditioning and refrigeration equipment
and service.
DEVELOPMENT
Combustion Test
Products are subjected to a wide range
of tests including combustion testing and
salt damage testing - all to confirm safe
operation under a variety of conditions.
Combustion testing is done by assuming
accidental firing and replicating abnormal
conditions that cause breakage of pressure
components.
Shock Resistance
On the assumption of many different kinds
of logistics environments in the world,
we perform drop/strength tests, transport
vibration tests, and many other product
checks to assure that the quality and per-
formance are maintained when the prod-
uct reaches the user's home.
Anechoic chamber
49
DESIGN
Designed to create and
maintain a comfortable environment
To improve the quality of our products, the engineers strive to
achieve its philosophy of combining ecology and comfort to an
even higher level. Therefore, we are working to further improve
quality at all stages from development to production.
PRODUCTION
Each and every unit is checked and double-checked by experienced professionals
Every air conditioner goes through rigorous electrical inspection on the manufacturing line. In final testing, our experienced inspectors listen
for even the faintest operation noise to detect any fault.
50
OPTIONAL
PARTS
Option Filter
Quick System
Anti-allergy Softdry Drain
Electrostatic Anti-allergy Enzyme Micro Particle Deodorizing Clean Control
Enzyme Cloth Pump
Filter Catching Filter Filter Kit Interface
Filter
PAC-
MAC- MAC- MAC- MAC- MAC- MAC- MAC- MAC- MAC- MAC-
KE07
Indoor Unit Model Name 2320FT 2320FT-E 2310FT-E 408FT-E EMF515FT EMF615FT 3010FT-E 093SS-E 1001CL-E 334IF-E
Outdoor unit Model Name DM-E
MSXZ-LN25VFR
MSZ-LN25VF)(V)(R)(B)
MSZ-LN35VF(V)(R)(B)
MSZ-LN10VF(V)(R)(B)
MSZ-LN13VF(V)(R)(B)
MSZ-LN18VF(V)(R)(B)
MSXY-JS15VF
MSXY-JS20VF
MSXY-JS25VF
Wal - MSXY-JS35VF
Mounted MSXY-JS50VF
MSXY-JS60VF
MSXY-JS71VF
MSZ-GE22VA
MSZ-GE25VA
MSZ-GE35VA
MSZ-GE42VA
MSZ-GE50VA
Indoor
MSZ-GE60VA
Unit
MSZ-GE71VA
1-way MLZ-KP25VF
Cassette MLZ-KP35VF
SEZ-M25DA
SEZ-M35DA
SEZ-M50DA
SEZ-M60DA
SEZ-M71DA
SEZ-M25DAL
SEZ-M35DAL
Ceiling -
SEZ-M50DAL
concealed
SEZ-M60DAL
SEZ-M71DAL
SEZ-KD25VAL
SEZ-KD35VAL
SEZ-KD50VAL
SEZ-KD60VAL
SEZ-KD71VAL
MXY-2H50VF
MXY-3H65VG
MXY SERIES
MXY-4H76VG
(R32)
MXY-4H92VG
MXY-5H105VG
Outdoor
MXZ-2D53VA2
Unit
MXZ-3E68VA
MXZ SERIES MXZ-4E72VA
(R410A) MXZ-4E83VA
MXZ-5E102VA
MXZ-6D122VA2
51
Joint Pipe
MA& Connector
Remote Remote
Contract Connector Remote Cable for Unit Unit Unit Unit Unit Drain M-NET
On/O Operation Air Outlet Guide
Terminal Cable Sensor Remote 9.52 6.35 9.52 12.7 12.7 Socket Adapter
Adapter Adapter
Interface Display --> --> --> --> -->
Pipe Pipe Pipe Pipe Pipe
15.88 9.52 12.7 9.52 15.88
Flare
PAC- PAC- PAC- PAC- MAC- MAC- PAC- PAC- PAC-
MAC- MAC- MAC- PAC- PAC- MAC- MAC- MAC-
SE41 SE55 SF40 SF40 889 856 SH96 SG60 IF01
397IF-E 1702RA-E 1710RA-E SG76 493 A454 A455 A456
TS-E RA-E RM-E RM SG SG SG-E DS-E MNT-E
RJ-E PI JP-E JP-E JP-E
52
NOTICE
■ Do not install indoor units in areas (e.g. mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ Our air-conditioning equipments and heat pumps contain a fluorinated greenhouse gas, R410A (GWP: 2088) or
R32 (GWP: 675). *These GWP values are based on Regulation (EU) No.517/2014 from IPCC 4th edition. In case of
Regulation (EU) No.626/2011 from IPCC 3rd edition, these are as follows. R410A (GWP: 1975), R32 (GWP: 550)
■ When installing or relocating or servicing our air-conditioning equipment, use only the specified refrigerant (R410A or R32)
to charge the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
https://www.mitsubishielectric.com/