SPLIT-TYPE AIR CONDITIONERS Residential Multi Split Product Line Catalogue

R32 MXY series


R410A MXZ series

Wrap Yourself in Comfort and Quiet


Eco-conscious Technologies from Japan

Residential Multi Split Product Line Catalogue


Mitsubishi Electric Inverter Multi split Systems
For luxury mansion and condominium,
Maximize the comfortability with a single outdoor u

Space Savings Energy Saving Operation


The Mitsubishi Electric Inverter Multi split System is designed We are able to offer industry-leading levels of energy-efficient
to allow from 2 to 6 indoor units to be connected to a single operation for both heating and cooling with the latest innova-
outdoor unit. This enhances exterior aesthetics by reducing tive inverter technologies. Save energy and money with the
the number of outdoor units necessary, while also providing Mitsubishi Electric Inverter Multi split System.
you with an easy and economical way of adding indoor units
at any time.

1
unit,

Quiet Control Flexible Choice


Comfort and quiet, based on smooth operation and innovative Offering the ability to select up to 6 indoor units for a single
features such as automatic selection of quiet mode when outdoor unit, Mitsubishi Electric Inverter Multi split Systems
operation load is low. Choose a wall-mounted model to create satisfy diversified needs. With the cooling capacities of
a quiet and comfortable space where noise levels are kept low outdoor units ranging from 5.0kW to 12.2kW and a line up of
so that soothing peace and quiet can be enjoyed. different models to suit specific applications, you will not be
hard pressed to find a better match for your building dimen-
sions and comfort requirements.

2
Types of Air Conditioning Systems and
Suitable Choice for Your Home
Enhance room comfort with the air conditioner that best matches the interior.
For reliable operation and design, Mitsubishi Electric is the logical choice.

Single Split
■ Suitable for
· Small residences like studio apartments
· Homes with floor area of 20m2-50m2
· Installing additional units if required

Multi Split System


MXY MXZ series (5.0kW~12.2kW)
■ Suitable for
· Small to medium-sized residences (condominiums or leased apartments)
· Homes with floor area of 50m2-100m2
· Homes with limited space for outdoor unit installation
· Increasing usable space at homes (for developers)
· Users who prefer to keep neat appearance with ceiling-concealed model
· Wide variety of indoor unit combination

TABLE OF CONTENTS
■ MXY series 7
■ MXZ series 25
Installation Image

3
LINE-UP
NEW RELEASE NEW RELEASE

MXY-H SERIES INVERTER Cooling Only Models Indoor Unit For MXY-H SERIES
Capacity
Model Name Capacity class (Min.-Max.) Model Name 1.5kW 2.0kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW

MSZ/MSXZ-LN Series
Up to 2 indoor units
5.0kW (1.3kW-6.5kW)
MXY-2H50VF
Wall-
mounted
MSXY-JS Series
Up to 3 indoor units
6.5kW (1.3kW-8.3kW)
MXY-3H65VG

MLZ-KP Series
Up to 4 indoor units 1-way
7.6kW (1.3kW-8.9kW) cassette
MXY-4H76VG

SEZ-M Series
Compact
Up to 4 indoor units
9.2kW (1.4kW-11.2kW) ceiling-
MXY-4H92VG concealed

*1 The line up of connectable indoor units differ by region.

Up to 5 indoor units
10.5kW (1.4kW-13.0kW)
MXY-5H105VG

MXZ SERIES INVERTER Heat Pump Models Indoor Unit For MXZ SERIES
Capacity
Model Name Capacity class (Min.-Max.) Model Name 2.2kW 2.5kW 3.5kW 4.2kW 5.0kW 6.0kW 7.1kW

MSZ-GE Series
Up to 2 indoor units Wall-
5.3kW (1.1kW-5.6kW)
MXZ-2D53VA2 mounted

SEZ-KD Series
Compact
Up to 3 indoor units
6.8kW (2.9kW-8.4kW) ceiling-
MXZ-3E68VA concealed

*2 The line up of connectable indoor units differ by region.


Up to 4 indoor units
MXZ-4E72VA 7.2kW (3.7kW-8.8kW)

Up to 4 indoor units
8.3kW (3.7kW-9.2kW)
MXZ-4E83VA

Up to 5 indoor units
10.2kW (3.9kW-11.0kW)
MXY-5E102VA

Up to 6 indoor units
12.2kW (3.5kW-13.5kW)
MXZ-6D122VA2

4
New Released MXY-H series features
Expanded line-up for cooling only model
We are introducing additional line-up of MXY-3H65VG(6.5kW with 3-port) and MXY-5H105VG(10.5kW with 5-port).
It is ideal if you are looking to cool a bigger room in your home.
Capacity class 5.0kW 6.5kW (NEW) 7.5kW 9.2kW 10.5kW (NEW)
Previous R410A Model 2-port - 3-port/4-port 4-port -
New R32 Model 2-port 3-port 4-port 4-port 5-port
*R410A Model : MXY-2E20VA/3A28VA/4A28VA/4A38VA

Further enhanced energy savings


The new R32 MXY-H series realize high energy savings with its high energy efficiency.
All models in the series have achieved high level of energy-saving performance, and are contributing to reduce energy consumption in
homes.
Energy saving improvement
+25% +21% +15%
5
4.64
Ratings(EER[kW/kW])

4.5 4.35
4.20 4.34
4 3.76 3.79

3.5 3.47 3.47

2.5

2
5.0kW(2-port) 6.5kW(3-port) 7.5-7.6kW(4-port) 9.2kW(4-port) 10.5kW(5-port)
R410A MXY-A/E series R32 MXY-H series

NEW
More compact & Lighter Design for 9.2kW class
Compact design fits into narrow outdoor unit space of condominiums.
Light weight design facilitates easy installation.
MXY-4A38VA MXY-4H92VG
11%
reduction
Height Height
900mm 796mm
14%
796mm
900mm

reduction
Weight Weight
67kg 57kg

NEW NEW
Operating at high temperatures (52 ) Blue fin condenser
New Inverter technology has made it possible for units to operate A special coating is applied to the heat exchanger to increase
at an outdoor air temperature as high as 52 . corrosion toughness.
Operating range

New models

Conventional models

40°C 42°C 44°C 46°C 48°C 50°C 52°C


Outdoor-air temperature

5
New Indoor units for MXY-H series
Wide range of indoor units
A multiple series line-up to choose from each with various outstanding features.
It has made it possible to match usage needs.
Wall-mounted 1-way cassette Compact ceiling- concealed

NEW MSZ/MSXZ-LN series NEW MSXY-JS series NEW MLZ-KP series SEZ-M series

(For MSZ/MSXZ-LN series)


Plasma Quad Plus is a plasma-based filter system that effectively removes six kinds of air pollutants. Plasma Quad Plus captures mold
and allergens . It can also capture PM2.5 and particles smaller than 2.5µm, creating healthy living spaces for all.

Image of Plasma Quad Plus

Principle of Plasma Quad Plus

Dust, PM2.5
Dirty Air
Viruses Bacteria
Mold Allergens
1st stage
• Make plasma.
• Break mold and allergens.
Wire Wire Inhibit viruses.
• Dust and PM2.5 given
an electrical charge (+).

2nd stage
• Make a strong electrical field.
• The charged dust and PM2.5 (+)
are absorbed in the strong
electrical field (-).
Clear air

Powerful Cool (For MSZ /MSXZ-LN,MSXY-JS series)


Push the Powerful Cool button when you need to cool down quickly, such as when you return home on a hot day, or when you have
guests over.

Powerful Cool
)
Air Outlet Temperture (

Nomal Operation

Comfortable temperature
can be reached in less time.

Time

6
MXY-H
SERIES
R32

Cooling Only

7
SELECTION
Choose from three types of indoor units and three types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.

STEP 1 SELECT INDOOR UNITS


Select the indoor unit to be installed in each room.

Wall-mounted 1-way cassette Compact ceiling-concealed

MSZ/MSXZ-LN

MSXY-JS(15-35)

MSXY-JS(50) MLZ-KP series SEZ-M series

MSXY-JS(60-71)

STEP 2 SELECT OUTDOOR UNITS


Select the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port 3-port 4-port 5-port


Connect up to 2 indoor units Connect up to 3 indoor units Connect up to 4 indoor units Connect up to 5 indoor units

MXY-2H50VF MXY-3H65VG MXY-4H76VG MXY-4H92VG MXY-5H105VG

STEP 3 CHECK SYSTEM COMPATIBILITY


Possible combinations depend on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Check Indoor Unit Capacity Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit
Combination selected is connectable. (Combinations not listed cannot be connected.)

If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.

8
Cooling Only
MXY R32
SERIES
Our Inverter Technology adjusts capacity in response to conditions such as
the difference between the outside and inside air temperatures, allowing
Outdoor
Unit

our air conditioners to run more efficiently and reduce energy costs.

2-port MXY-2H50VF 3-port MXY-3H65VG 4-port MXY-4H92VG


4-port MXY-4H76VG 5-port MXY-5H105VG

EXAMPLE SYSTEM

MSZ/MSXZ-LN

MSXY-JS

MSXY-JS

MLZ-KP

MXY-5H105VG

SEZ-M

Handle Up to 5 Rooms with a Single Outdoor Unit


The MXY Series offers a five-system line-up to choose from, ranging between 5.0 and 10.5kW. All of them are compatible with specific
Wall-mounted, 1-way cassette, Compact ceiling concealed type indoor units. A single outdoor can handle a wide range of building layouts.
BLUE
FIN

Type Inverter Cooling Only


Model Name MXY-2H50VF MXY-3H65VG MXY-4H76VG MXY-4H92VG MXY-5H105VG
Source Outdoor power supply
Power Supply
Outdoor (V/Phase/Hz) 220-230-240/Single/50, 220-230/Single/60
Rated kW 5.0 6.5 7.6 9.2 10.5
Capacity
Cooling Min - Max kW 1.3 - 6.5 1.3 - 8.3 1.3 - 8.9 1.4 - 11.2 1.4 - 13.0
Input Rated kW 1.15 1.4 1.81 2.12 2.77
EER Rated kW/kW 4.35 4.64 4.2 4.34 3.79
Dimensions HxWxD mm 550 x 800 x 285 710 x 840 x 330 796 x 950 x 330
Weight kg 37 55 56 57 60
Air Volume Cooling /min 32.9 38.7 38.7 67.5 67.5
Sound Level (SPL) Cooling dB(A) 49 49 49 51 51
Breaker Size A 15 20 25 25 25
Liquid mm 6.35 × 2 6.35 x 3 6.35 x 4 6.35 x 4 6.35 x 5
Diameter
Gas mm 9.52 × 2 9.52 × 3 9.52 × 3 + 12.7 × 1 9.52 × 3 + 12.7 × 1 9.52 × 4 + 12.7 × 1

Ext. Piping Total Piping Length


m 30 60 60 70 75
(max)
Each Indoor Unit
m 20 25 25 25 25
Piping Length
Max. Height m 15 (10) *1
Guaranteed Operating Range
+10 +52 +10 +52 +10 +52 +10 +52 +10 +52
(Outdoor)
*1: If the outdoor unit is installed higher than the indoor unit, max height is reduced to 10m.

9
Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit MXY-

Indoor Unit 2H50VF 3H65VG 4H76VG 4H92VG 5H105VG


MSZ-LN10VF
Wall-mounted MSZ-LN25VF
MSXZ-LN25VFR
<Ruby Red>

MSZ-LN13VF
MSZ-LN35VF

MSZ-LN10/13/18VFR
MSZ-LN25/35VFR
MSZ-LN18VF
MSXZ-LN25VFR
<Onyx Black>

MSXY-JS15VF

MSZ-LN10/13/18VFB
MSZ-LN25/35VFB

<Pearl White>
MSXY-JS20VF

MSXY-JS25VF
MSZ-LN10/13/18VFV
MSZ-LN25/35VFV

MSXY-JS35VF

MSXY-JS15/20/25/35VF
MSXY-JS50VF

MSXY-JS60VF
MSXY-JS50VF

MSXY-JS71VF

MSXY-JS60/71VF

MLZ-KP25VF
1-way cassette

MLZ-KP35VF

SEZ-M25DA(L)
Ceiling-concealed

SEZ-M35DA(L)

SEZ-M50DA(L)

SEZ-M60DA(L)

SEZ-M71DA(L)

10
MSZ-LN25/35VF
MSZ-LN10/13/18VF

MSXZ-LN
MSXZ-LN25VF

MSZ-LN SERIES
Developed to complement modern interior room décor, the LN Series is
available in three colours specially chosen to blend in naturally wherever
installed. Not only the sophisticated design, but also operational comfort
add even more value to this series.

Luminous and Luxurious Design


Pearl White, Ruby Red, and Onyx Black. LN Series indoor units are available in three colours to match various lifestyles. The appearance of the
indoor unit differs depending on the lighting in the room, attracting the attention of everyone that enters the room.

Master craftsmanship painting technology has resulted in a refined Pearl White blends in with any interior.
design, giving the finish deep colour and a premium quality feel.

Ruby Red gives an accent to the room, affording timeless elegance to Onyx Black matches darker interiors, creating a comfortable environment.
sophisticated interiors.

LED Backlight Remote Controller


Not only the indoor units, but the wireless remote
controllers come in three colours as well. Each remote
controller matches the indoor unit. Even the textures are
the same.

The setting can be easily


checked in the dark.
Pearl Ruby Onyx
11 White Red Black
The LN Series is equipped with 3D i-see Sensor, an infrared-ray Indirect Airflow Direct Airflow
sensor that measures the temperature at distant positions. While The indirect airflow setting can be used when This setting can be used to directly target
the flow of air feels too strong or direct. For airflow at people such as for immediate
moving to the left and right, eight vertically arranged sensor example, it can be used during cooling to comfort when coming indoors on a hot
elements analyze the room temperature in three dimensions. This avert airflow and prevent body temperature (cold) day.
detailed analysis makes it possible to judge where people are from becoming excessively cooled.

in the room, thus allowing creation of features such as “Indirect


airflow,” to avoid airflow hitting people directly, and “direct airflow”
to deliver airflow to where people are.

Sensor with
eight elements

Even Airflow
Normal swing mode Even airflow mode

8 × 94 areas
Sensor measures while
moving to the left to right

Divided into 94
The airflow is distributed equally throughout The 3D i-see sensor memorizes human move-
(Image) the room, even to spaces where there is no ment and furniture positions, and efficiently
human movement. distributes airflow.

No occupancy energy-saving mode


The sensors detect whether there are people in the room. When no-one is in the room,
the unit automatically switches to energy-saving mode. No occupany Auto-OFF mode
The sensors detect whether or not there are people in the room. When there is no one
in the room, the unit turns off automatically.
AUTO
OFF

The “3D i-see Sensor” detects people’s absence and the power consumption is automatically
reduced approximately 10% after 10 minutes and 20% after 60 minutes.

12
Plasma Quad Plus is a plasma-based filter system that effectively removes six kinds of air pollutants. Plasma Quad Plus captures mold and
allergens. It can also capture PM2.5 and particles smaller than 2.5µm, creating healthy living spaces for all.

Bacteria Viruses Molds

Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad
Plus neutralizes 99% of bacteria in 162 minutes Plus neutralizes 99% of virus particles in 72 Plus neutralizes 99% of mold in 135 minutes in
in a 25m3 test space. minutes in a 25m3 test space. a 25m3 test space.

<Test No.> KRCES-Bio. Test Report <Test No.> vrc.center, SMC <Test No.> Japan Food Research Laboratories
No. 2016-0118 No. 28-002 Test Report No. 16069353001-0201

Allergens PM2.5 Dust

In a test, air containing cat fur and pollen was Test results have confirmed that Plasma Quad Test results have confirmed that Plasma Quad
passed through the air cleaning device at the Plus removes 99% of PM2.5 in 145 minutes in Plus removes 99.7% of dust and mites.
low airflow setting. Before and after measure- a 28m3 test space.
ments confirm that Plasma Quad Plus neutraliz-
es 98% of cat fur and pollen.

<Test No.> ITEA Report No. T1606028 <In-company investigation> <Test No.> ITEA Report No. T1606028

Image of Plasma Quad Plus

Principle of Plasma Quad Plus

Dust, PM2.5
Dirty Air
Viruses Bacteria
Mold Allergens
1st stage
• Make plasma.
• Break mold and allergens.
Wire Wire Inhibit viruses.
• Dust and PM2.5 given
an electrical charge (+).

2nd stage
• Make a strong electrical field.
• The charged dust and PM2.5 (+)
are absorbed in the strong
electrical field (-).
Clear air

13
A two-barrier coating prevents dust and greasy dirt from getting into the air conditioner.

Dual Barrier
Coating is used for
• Heat exchanger
• Fan
• Air duct

State-of-the-art coating technology


Dirt is generally classified into two groups: hydrophilic dirt such as fiber dust and sand dust, and hydrophobic dirt such as oil and cigarette smoke.
Mitsubishi Electric’s dual barrier coating works as a two-barrier coating with blended “fluorine particles” that prevent hydrophilic dirt penetration
and “hydrophilic particles” that prevent hydrophobic dirt from getting into the air conditioner. This dual coating on the inner surface keeps the air
conditioner clean year-round.

Comparison of dirt on heat exchanger,


fan and air duct (in-house comparison)
Hydrophobic dirt Hydrophilic dirt
Heat exchanger

Fan

Air duct

No dual barrier coating (image after 10 years) Dual barrier coating used

The inside of the indoor unit gets dirty after many years of usage.
Heat exchanger Fan Consequences when the inside
New 10 years later (image) New 10 years later (image) of the indoor unit is left dirty.

• Deterioration in energy
efficiency.
• Musty smell from the unit.

14
Double Flap
The vanes create various airflows to make each person in the room comfortable. Not only the horizontal vanes, but also the vertical vanes move
independently, eliminating hot spots or cold spots throughout the room.

Quiet Operation
The indoor unit noise level is as low as 19dB for LN25/35 models, offering a peaceful inside environment.

● Noise Level
Quiet passenger Human
Subway car car interior Sound of hearing limits
Library interior
interior (40km/h) rustling leaves (Extremely quiet)

80dB 60dB 40dB 10dB


Only 19dB
(for LN25/35/10/13 models)
In-house
investigation

15
MSXZ-LN
MSZ-LN SERIES
Indoor Unit / Remote Controller

<Ruby Red> <Pearl White>

MSZ-LN10/13/18VFR MSZ-LN10/13/18VFV
MSZ-LN25/35VF MSZ-LN25/35VFV
MSXZ-LN25VFRR

<Onyx Black>

MSZ-LN10/13/18VFB
MSZ-LN25/35VFB

Dual Barrier Double Weekly


HUMAN Coating Vane Timer

Back Light
Remote

Type Cooling
Model Name MSXZ-LN25VF MSZ-LN25VF MSZ-LN35VF MSZ-LN10VF MSZ-LN13VF MSZ-LN18VF
Power Supply Source Outdoor Power Supply

Air Volume /min 4.3 - 5.9 - 4.3-5.8- 4.3-5.8- 4.3-5.8- 4.3-5.8- 5.7-7.6-
Quiet-Lo- 7.2 - 8.9 - 12.0 7.1-8.8-11.9 7.1-8.8-11.9 7.1-8.8-11.9 7.1-8.8-11.9 8.8-10.6-13.9
Cooling 1
Sound Level Med-Hi-SHi*
dB(A) 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 19 - 23 - 29 - 36 - 42 27 - 31 - 35 - 39 - 46
(SPL)
Operating Current (max.) A 0.16 0.21 0.21 0.21 0.21 0.28
Dimensions H x W x D mm 307 x 890 x 233 307 x 890 x 233 307 x 890 x 233
Weight kg 15.5 15.5 15.5 15.5 15.5 15.5
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7
*1SHi : Super High * The lineup differs by region.

16
MSXY-JS15/20/25/35VF

MSXY-JS50VF

MSXY-JS SERIES
MSXY-JS60/71VF

JS Series features advanced technology developed worldwide through many years of experience. We have achieved powerful
cooling with high energy efficiency to bring you optimal comfort. Moreover you can select the indoor unit with many advantages
which covers with wide range of cooling capacity.

New Design

MSXY-JS15/20/25/35VF MSXY-JS50VF

MSXY-JS60/71VF
Powerful Cool
Push the Powerful Cool button when you need to cool down quickly, such as when you return home on a hot day, or when you have
guests over.

Powerful Cool
Comfortable temperature
can be reached in less time.

Powerful
Cool

Cooling starts immediately Once activated,


with the push of a button this mode continues
for 15 mins.

Sleep mode

Slightly lowers Automatically returns


temperature to to original setting
support body to temperature after
release heat 120mins
Setting Temperature (°C )

Approx.
120 mins

Sleeping mode ”ON” Time

17
Auto Vane Control*Up and Down/Left and Right *Only for JS50/60/71

Auto vanes can be moved left and right, and up and down using the remote controller.

Horizontal Airflow / Auto Vane Control Auto Vane Up & Down


Control Auto vanes can be set at 5 positions and swing.
Button

SWING

Left & Right


Auto vanes can be set at 5 position and swing.
Up and Down Left and Right
POWERFUL

SWING

Long airflow (JS50/60/71) MITSUBISHI ELECTRIC launched the World’s First *


Room Air Conditioner equipped with Cross Flow Fan in 1968.
Projects air current up to 12meters.
Suitable even for living rooms. * Based on Euromonitor International research
Cross Flow Fan Technology
A B
A Flap
Wing

Wing
B Flap
Cross Flow Fan

Our unique Cross Flow Fan construction guides air smoothly along each rotating wing as it simultaneously intakes and expels air. This
allows for highly efficient delivery of powerful and refreshing airflow.

Microparticle Catching Filter ( Optional parts )


Effectively catches floating PM 2.5 particles to maintain clean air in the room.
Electrostatic material removes PM2.5
from the air and absorbs it when passing
Clean Electrostatic filter material
air through the filter.

PM2.5

Dirty Clean
air air

Model name MAC-EMF515FT-E


Dirty MAC-EMF615FT-E
air Electrostatic filter material

18
A two-barrier coating prevents dust and greasy dirt from getting into the air conditioner.

State-of-the-art coating technology


Dirt is generally classified into two groups: hydrophilic dirt such as fiber dust and sand dust, and hydrophobic dirt such as oil and cigarette smoke.
Mitsubishi Electric’s dual barrier coating works as a two-barrier coating with blended “fluorine particles” that prevent hydrophilic dirt penetration
and “hydrophilic particles” that prevent hydrophobic dirt from getting into the air conditioner. This dual coating on the inner surface keeps the air
conditioner clean year-round.

Dual Barrier repels both types of dirt Comparison of dirt on Heat exchanger, Fan and Air duct

Hydrophobic coating Heat exchanger Fan Air duct


Hydrophilic coating
( Fluorine particle )

Hydrophilic Hydrophobic
dirt dirt

Dust Oil mist


Dirt Cigarette smoke
Fiber dust

Image Dual Barrier Image Dual Barrier Image Dual Barrier


after 10years Coating used after 10years Coating used after 10years Coating used
Base material

Optional Optional (50/60/71) (50/60/71)

Type Cooling Only


Model Name MSXY-JS15VF MSXY-JS20VF MSXY-JS25VF MSXY-JS35VF MSXY-JS50VF MSXY-JS60VF MSXY-JS71VF
Power Supply Source Outdoor power supply
/ 4.8-6.3- 4.8-6.3- 4.8-8.2- 4.8-8.7- 8.5-11.3- 10.2-11.8- 10.2-12.2-
Air Volume Quiet-Lo-
min 7.8-9.1-10.5 7.8-9.1-10.5 9.6-11.0-12.3 10.4-11.7-13.3 13.4-15.2-16.6 13.4-14.9-17.3 14.1-16.3-20.7
Cooling Med-Hi-
Sound SHi*1 dB(A) 22 - 31 - 34 - 37 - 40 22 - 31 - 34 - 37 - 40 22 - 35 - 38 - 41 - 44 22 - 36 - 40 - 43 - 46 31 - 35 - 38 - 41 - 45 32 - 36 - 40 - 44 - 50 32 - 37 - 41 - 45 - 53
Level (SPL)
Operating Current (max.) A 0.16 0.16 0.23 0.27 0.31 0.30 0.45
Dimensions H x W x D mm 280 × 838 × 235 280 × 838 × 235 280 × 838 × 235 280 × 838 × 235 305 × 923 × 262 325 × 1,100 × 238 325 × 1,100 × 238
Weight kg 9 9 9 9 12.5 15 15
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7
*1SHi : Super High *The line up differs by region.

19
MLZ-KP25/35VF

MLZ SERIES
Introducing a new type of ceiling cassette for the
Multi-Split Series with streamed interior dimen-
sions and a sharp, sleek appearance. 2017

Slim Design
Industry leading slim body realized a simple design with linear beauty.

Ceiling-Mounted Slim Body


Installing the ceiling-mounted MLZ The new units are designed with a slim body (only 185mm high), en-
Series unit in a room creates a more suring easy installation even when low ceiling cavities limit installa-
spacious feel that enhances room tion space. The need for ceiling cavity service space is also eliminat-
comfort. This overhead format is also ed, further reducing the dimensions required for installation.
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as 185mm
book shelves are mounted on wall
surfaces.

Set Airflow According to Ceiling Height


Dual-level airflow selection is engineered to accommodate specific
MLZ-KP25/35VF
ceiling heights. This is a key feature for adjusting airflow effectively
when it is either too strong or too weak due to being mismatched Standard 2.4m
with the height of the ceiling.
High ceiling 2.7m

20
Auto Vane Control Horizontal Airflow
Outlet vanes can be moved left and right, and up and down using The new airflow control completely eliminates that uncomfortable
the remote controller. This improved airflow control feature solves drafty-feeling with the introduction of a horizontal airflow that spreads
the problem of drafts. across the ceiling. The ideal airflow for offices and restaurants.

[Horizontal Airflow]
Model name: MLZ-KP35VF
Ceiling height: 2.4m
Model: Cooling

3.0 4.0

2
1.0 0.5

Height (m)
1

Up and Down Left and Right


0
4 3 2 1 0
✽ Only available when Econo Cool is set.
Floor distance (m)

Built-in Weekly Timer Function


Easily set desired temperatures and operation ON/OFF times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

■ Easy set-up using dedicated buttons


PUSH PUSH PUSH
The remote controller is How to set
equipped with buttons that the Weekly
are used exclusively for Timer Select the day Select the period
setting the Weekly Timer. Ready to set
Setting operation patterns
is easy and quick.
PUSH
PUSH PUSH PUSH

Complete Select ON/OFF Select the time Set the temperature

• Start by pushing the “SET” button and follow the instructions to set the desired patterns.
Once all of the desired patterns are input, point the top end of the remote controller at the
indoor unit and push the “SET” button one more time. (Push the “SET” button only after in-
putting all of the desired patterns into the remote controller memory. Pushing the “CANCEL”
button will end the set-up process without sending the operation patterns to the indoor unit).
• It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit.
Please continue to point the remote controller at the indoor unit until all data has been sent.

21
Easy Installation
Industry leading Slim Body
Inovative size which enables to fold the refrigerant piping above
the unit. Industry leading
185 mm
Dimension: 185(H)×1102(W)×360(D)mm

Temporary hanging hook


Work efficiency has improved during installation.

Secure one side Push the unit to one side Move unit to the centre
Secure the opposite side

Drain Piping Supporters + Drain Cover

Drain piping

Easy joint Insulation-free cover


Drain piping collects condensation
connections!
500mm Insulating material
wrapping only in the drain pan.
required from this
point No need
for wrapping

Insulating material pretreatment


eliminates need for wrapping. Drain cover

Air Purifying
Electrostatic Weekly
Anti-allergy Timer
Optional Optional

Type Cooling
Model Name MLZ-KP25VF MLZ-KP35VF
Power Supply Source Outdoor Power Supply
Operating Current (max.) A 0.4 0.4
Air Volume /min 6.0 - 7.2 - 8.0 - 8.8 6.0 - 7.3 - 8.4 - 9.4
SLo-Lo-Med-Hi
Indoor Sound Level (SPL) dB(A) 27 - 31 - 34 - 38 27 - 32 - 36 - 40
Unit Dimensions HxWxD mm 185 × 1,102 × 360 185 × 1,102 × 360
Weight kg 15.5 15.5
Dimensions HxWxD mm 24 × 1,200 × 424 24 × 1,200 × 424
Panel
Weight kg 3.5 3.5
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52
*Panel : MLP-444W

22
SEZ SERIES SEZ-M25/35/50/60/71DA with wired Remote Controller
SEZ-M25/35/50/60/71DAL with wireless Remote Controller
This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the
ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units
require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Dimension 990mm A Air inlet


B Air outlet
C Access door
D Ceiling surface
200mm E Canvas duct
F Air filter
G Inlet grille

SEZ-M35DA(L)

Wide Selection of Fan Speed and Static Pressure Level


Three fan speeds (Lo - Med - Hi) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet
various needs.

Drain Pump (Optional)


The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
leading to increased installation possibilities.

Optional

Type Cooling
Model Name SEZ-M25DA(L) SEZ-M35DA(L) SEZ-M50DA(L) SEZ-M60DA(L) SEZ-M71DA(L)
Power Supply Source Outdoor Power Supply
Air Volume /min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0
Cooling Lo-Med-Hi
Sound Level (SPL) dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40
External Static Pressure Pa 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50
Operating Current (max.) A 0.39 0.46 0.63 0.63 0.84
Dimensions HxWxD mm 200 × 790 × 700 200 × 990 × 700 200 × 990 × 700 200 × 1,190 × 700 200 × 1,190 × 700
Weight kg 17.5 21 22 25.5 8
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88

23
24
MXZ R410A
SERIES
Heat pump

25
SELECTION
Choose from three types of indoor units and five types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.

STEP 1 SELECT INDOOR UNITS


Select the indoor unit to be installed in each room.

Wall-mounted Ceiling-concealed

MSZ-GE(22/25/35/42/50)

SEZ-KD
MSZ-GE(60/71)

STEP 2 SELECT OUTDOOR UNITS


Select the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port 3-port 4-port


Connect up to 2 indoor units Connect up to 3 indoor units Connect up to 4 indoor units

MXZ-2D53VA2 MXZ-3E68VA MXZ-4E72VA MXZ-4E83VA

5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units

MXZ-5E102VA MXZ-6D122VA2

STEP 3 CHECK SYSTEM COMPATIBILITY


Possible combinations depend on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with
Check Indoor Units
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Check Indoor Unit Capacity Refer to the “Combination Table” in data book to check if the capacity combination of the indoor unit
Combination selected is connectable. (Combinations not listed cannot be connected.)

If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.

26
MXZ
Outdoor
Unit

R410A
SERIES
Heat pump

Advancements in the MXZ Series include efficiency and flexibility in system


expansion capabilities. The best solution when requiring multi-system air
conditioning needs.

2-port MXZ-2D53VA2 3-port MXZ-3E68VA 4-port MXZ-4E83VA 6-port MXZ-6D122VA2


4-port MXZ-4E72VA 5-port MXZ-5E102VA

EXAMPLE SYSTEM
MXZ-6D122VA2 MSZ-GE

MSZ-GE

MXZ-6D122VA
SEZ-KD

Handle Up to 6 Rooms with a Single Outdoor Unit


The MXZ Series offers a six-system line-up to choose from, ranging between 5.3 and 12.2kW. All of them are compatible with specific M, S and
P series indoor units. A single outdoor unit can handle a wide range of building layouts.

2D-4E83 4E83-6D 3E-4E72

Type Inverter Heat Pump


Outdoor Unit MXZ-2D53VA2 MXZ-3E68VA MXZ-4E72VA MXZ-4E83VA MXZ-5E102VA MXZ-6D122VA2
Power Source Outdoor power supply
Supply Outdoor (V/Phase/Hz) 220 - 230 - 240 / Single / 50
Capacity Rated kW 5.3 6.8 7.2 8.3 10.2 12.2
Cooling
Min - Max kW 1.1 - 5.6 2.9 - 8.4 3.7 - 8.8 3.7 - 9.2 3.9 - 11.0 3.5 - 13.5
Capacity Rated kW 6.4 8.6 8.6 9.3 10.5 14.0
Heating
Min - Max kW 1.0 - 7.0 2.6 - 10.6 3.4 - 10.7 3.4 - 11.6 4.1 - 14.0 3.5 -16.5
Outdoor Dimensions H×W×D mm 550 × 800 × 285 710 × 840 × 330 796 × 950 × 330 1048 × 950 × 330
Unit Weight kg 37 58 59 63 64 88
Air Volume Cooling m3/min 32.9 42.1 42.1 55.6 65.1 63.0
Heating m3/min 33.3 43.0 43.0 55.6 68.0 77.0
Sound Level (SPL) Cooling dB(A) 50 50 50 49 52 55
Heating dB(A) 53 53 53 51 56 57
Breaker Size A 15 25 25 25 25 32
Ext. Diameter Liquid mm 6.35 × 2 6.35 × 3 6.35 × 4 6.35 × 4 6.35 × 5 6.35 × 6
Piping 9.52 × 2 9.52 × 3 12.7×1+9.52×3 12.7×1+9.52×3 12.7×1+9.52×4 12.7×1+9.52×5
Gas mm
Total Piping Length (max) m 30 60 60 70 80 80
Each Indoor Unit Piping Length (max) m 20 25 25 25 25 25
Max. Height m 15 (10)*1

Chargeless Length m 20 40 40 25 0 30
Guaranteed Operating Range Cooling oC –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46 –10 ~ +46
[Outdoor] Heating oC –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24 –15 ~ +24
*1: If the outdoor unit is installed higher than the indoor unit, max height is reduced to 10m.

27
Indoor Unit Compatibility Table
Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit MXZ-

Indoor Unit 2D53VA2 3E68VA 4E72VA 4E83VA 5E102VA 6D122VA2

MSZ-GE22VA
Wall-mounted

MSZ-GE25VA

MSZ-GE(22/25/35/42/50) MSZ-GE35VA

MSZ-GE42VA

MSZ-GE(60/71) MSZ-GE50VA

MSZ-GE60VA

MSZ-GE71VA

SEZ-KD25VAL
Ceiling-concealed

SEZ-KD35VAL

SEZ-KD50VAL

SEZ-KD60VAL
SEZ Series

SEZ-KD71VAL

28
MSZ-GE22/25/35/42/50VA

MSZ-GE60/71VA

MSZ-G SERIES
The standard model MSZ-G units provide excellent energy savings and operation is impressively quiet. A vast series line-up is ready
to ensure comfortable room environments in response to your air conditioning needs.
25-35

Wide Line-up
Only
Quiet Operation 19dB
Seven different indoor units (Model 22-71) are available to meet A “Quiet Mode” setting has been added to the fan speed settings,
your diversified air conditioning needs. ensuring super-quiet operation below 20dB for model sizes 35 and
under. Perfect for the bedroom; it’s so quiet you’ll check to see if it’s on.

Nano Platinum Filter Nano


60/71
Platinum

MSZ-GE22/25/35/42/50VA MSZ-GE60/71VA
This filter incorporates nanometre-sized platinum-ceramic particles
that generate stable antibacterial and deodourising effects. The size
Stylish and Compact of the three-dimensional surface has been increased as well, enlarg-
An elegant, high-quality look is achieved through the new stylish ing the filter capture area. These features give the Nano Platinum
design adopted for indoor units. The simple ergonomic square shape Filter of the MSZ-GE60/71 models better dust collection perfor-
and pure white color express a sense of sophistication that matches mance than conventional filters. The superior air-cleaning effective-
well with virtually any interior décor. ness raises room comfort yet another level.

MSZ-GE22/25/35/42/50VA Fits neatly above


800mm-wide doors.

800mm

It is okay to wash the filter with water


Only 798mm (air-cleaning effect is maintained) 3D surface (Waved surface)
In the case of MSZ-GE22-50
25 - 50 60/71 25 - 50 60/71 60/71 60/71 60/71

Electrostatic Nano
Anti-allergy Platinum
Optional Optional
4C/5C/6C 4C/5C/6C

Optional

Type Heat Pump


Model Name MSZ-GE22VA MSZ-GE25VA MSZ-GE35VA MSZ-GE42VA MSZ-GE50VA MSZ-GE60VA MSZ-GE71VA
Power Supply Source Outdoor Power Supply
4.1 - 4.6 - 4.1 - 4.6 - 4.1 - 4.8 - 5.8 - 6.8 - 6.5 - 7.8 - 9.8 - 11.3 - 9.7 - 11.5 -
Air Volume /min
Quiet-Lo- 6.7 - 9.2- 11.3 6.7 - 9.2- 11.3 6.9 - 9.2- 12.7 8.6 - 10.4 - 12.8 9.6 - 11.9 - 15.1 13.4 - 15.6 - 18.3 13.3 - 15.4 - 17.8
Cooling
Sound Level Med-Hi-SHi*1 19 - 21 - 29 - 36 - 19 - 21 - 29 - 36 - 19 - 22 - 30 - 36 - 26 - 30 - 35 - 40 - 28 - 33 - 38 - 44 - 29 - 37 - 41 - 45 - 30 - 37 - 41 - 45 -
dB(A)
(SPL) 42 42 43 46 49 49 49
4.1 - 4.8 - 4.1 - 4.8 - 4.1 - 4.8 - 5.8 - 7.0 - 6.5 - 7.9 - 9.8 - 11.3 - 10.2 - 11.5
Air Volume /min
Quiet-Lo- 6.6 - 9.1 - 11.5 6.6 - 9.1 - 11.5 6.7 - 9.1 - 11.5 8.6 - 10.4 - 13.1 9.6 - 12.2 - 14.5 13.4 - 14.7 - 18.3 13.3 - 15.4 - 17.8
Heating
Sound Level Med-Hi-SHi*1 19 - 21 - 29 - 36 - 19 - 21 - 29 - 36 - 19 - 22 - 29 - 36 - 26 - 30 - 35 - 40 - 28 - 33 - 37 - 43 - 29 - 37 - 41 - 45 - 30 - 37 - 41 - 45 -
dB(A)
(SPL) 42 42 42 46 48 49 49
Operating Current (max.) A 0.23 0.23 0.23 0.31 0.39 0.53 0.51
Dimensions H x W x D mm 295 × 798 × 232 295 × 798 × 232 295 × 798 × 232 295 × 798 × 232 295 × 798 × 232 325 × 1,100 × 328 325 × 1,100 × 328
Net Weight kg 10 10 10 10 10 16 16
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88
*1SHi : Super High * The lineup differs by region.

29
30
SEZ SERIES SEZ-KD25-71VAL

This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the
ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior décor. The compact units
require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Dimension 990mm A Air inlet


B Air outlet
C Access door
D Ceiling surface
200mm E Canvas duct
F Air filter
G Inlet grille

SEZ-KD35VAL

Wide Selection of Fan Speed and Static Pressure Level


Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet
various needs.

Drain Pump (Optional)


The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
leading to increased installation possibilities.

Optional

Type Heat Pump


Model Name SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL
Power Supply Source Outdoor Power Supply
Air Volume /min 5.5 - 7.0 - 9.0 7.0 - 9.0 - 11.0 10.0 - 12.5 - 15.0 12.0 - 15.0 - 18.0 12.0 - 16.0 - 20.0
Lo-Med-Hi
Sound Level (SPL) dB(A) 23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38 30 - 35 - 40
External Static Pressure Pa 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50 5/15/35/50
Operating Current (max.) A 0.39 0.46 0.63 0.63 0.84
Dimensions HxWxD mm 200 × 790 × 700 200 × 990 × 700 200 × 990 × 700 200 × 1,190 × 700 200 × 1,190 × 700
Weight kg 18 21 23 27 27
Ext. Piping Diameter Liquid/Gas mm 6.35/9.52 6.35/9.52 6.35/12.7 6.35/15.88 9.52/15.88

31
External Dimensions
MXY SERIES
MXZ SERIES Unit : mm
MXY-2H50VF MXY-3H65VG
MXZ-2D53VA2 MXZ-3E68VA
OUTDOOR UNIT OUTDOOR UNIT
169 500 171
400
Drain hole 65.4 207.5 314

17.7
Air in Air

34
Inlet
44

18.3
304 325

16.6
344.5

(Bolt Pitch)
360.6
Air in

396
17.5

Air Inlet

12.3
40 Air

17.7
3- ø33 Drain hole Outlet
Air out
4-10x21 Oval Hole
2-10x21 Oval hole (Foundation Bolt M8)

22.3 23 285 13 Handle

10 840 30
200 25.8 330 12.5
handle

Connecting
wire hole
66

240
550

Liquid pipe B unit


51 51 51

Gas pipe connection

710
Liquid pipe
251.1
280

A unit
LIQ
Gas pipe connection Unit C
GAS
LIQ LIQ ø6.35(1/4")FLARE
Unit B

360
GAS GAS ø9.52(3/8")FLARE
LIQ
302.5 170.4
10

Unit A
GAS
150 500

800 69 299

MXY-4H76VG MXY-4H92VG
MZY-4E72VA MXZ-4E83VA
OUTDOOR UNIT OUTDOOR UNIT

169 500 171


175 600 175
65.4 207.5 314 REAR AIR
71.4 246.4
INTAKE
17.7

Air 51.4
2×U SHAPED NOTCHED HOLE
Inlet (FOUNDATION BOLT M10)
34

10 86.5 93.3 116.5


18.3

16
36
62
40
16.6

10
(Bolt Pitch)
360.6

396

10

(BOLT PITCH)

Air Inlet
134
12.3

370

417

SIDE AIR INTAKE


10

6× Ø33 DRAIN HOLE


Air
3- ø33 Drain Hole Outlet
17.7

10

10
31

AIR 10
51

DISCHARGE
4-10x21 Oval Hole 2×12×36 OVAL HOLE
(Foundation Bolt M8) (FOUNDATION BOLT M10)

Handle 950
10 840 30
25 330 15
200
25.8 330 12.5

HANDLE HANDLE
Connecting
wire hole
240

66
70
AIR INTAKE
796

LIQ
710

Unit D LIQ
GAS UNIT D
LIQ
GAS
Unit C LIQ ø6.35(1/4")FLARE
GAS ø9.52(3/8")FLARE LIQ LIQ Ø6.35(1/4")FLARE
GAS UNIT C
GAS GAS Ø9.52(3/8")FLARE
LIQ
407

Unit B LIQ
360

GAS UNIT B
GAS
LIQ LIQ ø6.35(1/4")FLARE LIQ LIQ Ø6.35(1/4")FLARE
Unit A GAS ø12.7(1/2")FLARE UNIT A
GAS GAS GAS Ø12.7(1/2")FLARE

299
361

32
MXY SERIES MXZ SERIES Unit : mm
MXY-5H105VG MXZ-6D122VA2
MXZ-5E102VA OUTDOOR UNIT
OUTDOOR UNIT

Air in
175 600 175
71 250 80 97 116 2-U Shaped Notched Hole
(Foundation Bolt M10)
51
10

36

16
62

10
40
134

(Bolt pitch)
370

417
Air in

10
6-ø33 Drain Hole

10
10 10

31
51
Air out

2-12×36 Oval Hole


(Foundation Bolt M10)

950 25 330 15

Handle
Handle
Handle
70
Liquid pipe : Ø6.35(flared)1/4 F unit
Gas pipe : Ø9.52(flared)3/8 connection

1048
Liquid pipe : Ø6.35(flared)1/4 E unit
Gas pipe : Ø9.52(flared)3/8 connection
Liquid pipe : Ø6.35(flared)1/4 D unit
Gas pipe : Ø9.52(flared)3/8 connection
Liquid pipe : Ø6.35(flared)1/4 C unit
Gas pipe : Ø9.52(flared)3/8 connection

563
Liquid pipe : Ø6.35(flared)1/4 B unit
Gas pipe : Ø9.52(flared)3/8 connection
Liquid pipe : Ø6.35(flared)1/4 A unit
Gas pipe : Ø12.7(flared)1/2 connection
Air Intake

361

33
Piping Installation
MXY SERIES MXZ SERIES
MXY-2H50VF MXZ-2D53VA2
Maximum Piping Length Indoor a Maximum height
units difference
Outdoor unit - Indoor unit (a,b) 20m
Total length (a+b) 30m
Outdoor Outdoor unit

Maximum Number of Bends


|

unit Indoor unit


15m
Outdoor unit - Indoor unit (a,b) 20 *Outdoor unit
installed lower Indoor unit
|

Total number (a+b) 30 Indoor unit


15m

Outdoor unit
|
Indoor unit
b 10m
*Outdoor unit
installed higher

MXY-3H65VG MXZ-3E68VA
Maximum Piping Length
Highest
Outdoor unit - Indoor unit (a,b,c) 25m Indoor Maximum height
units a
Total length (a+b+c) 60m difference

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c) 25 b Outdoor Outdoor unit
unit
|
Indoor unit
Total number (a+b+c) 60 15m
*Outdoor unit
installed lower
Indoor unit
|
Indoor unit
15m
Outdoor unit
Lowest
|

c Indoor unit
10m
*Outdoor unit
installed higher

MXY-4H76VG MXZ-4E72VA
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d) 25m Indoor
Total length (a+b+c+d) 60m units Highest Maximum height
a difference
Maximum Number of Bends
Outdoor unit - Indoor unit (a,b,c,d) 25 Outdoor
b
Total number (a+b+c+d) 60 unit Outdoor unit
|
Indoor unit
15m
*Outdoor unit
installed lower Indoor unit
|

c Indoor unit
MXY-4H92VG MXZ-4E83VA 15m
Maximum Piping Length
Outdoor unit
Outdoor unit - Indoor unit (a,b,c,d) 25m Lowest d
|
Indoor unit
10m
Total length (a+b+c+d) 70m *Outdoor unit
installed higher

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c,d) 25
Total number (a+b+c+d) 70

34
MXZ-5E102VA
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e) 25m Indoor
Highest Maximum height
Total length (a+b+c+d+e) 80m units difference
a

Maximum Number of Bends


Outdoor
b unit
Outdoor unit - Indoor unit (a,b,c,d,e) 25
Outdoor unit
Total number (a+b+c+d+e) 80
|
Indoor unit
c 15m
*Outdoor unit
installed lower Indoor unit
|
Indoor unit
15m
Outdoor unit
Lowest
|
Indoor unit
10m
d e
*Outdoor unit
installed higher

Indoor Maximum height


MXZ-5H105VG units Highest
a difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e) 25m
Outdoor
Total length (a+b+c+d+e) 75m b unit
Outdoor unit
|
Indoor unit
Maximum Number of Bends c 15m
*Outdoor unit
Outdoor unit - Indoor unit (a,b,c,d,e) 25 installed lower Indoor unit
|
Indoor unit
Total number (a+b+c+d+e) 75 15m
Outdoor unit
Lowest
|
Indoor unit
10m
d e
*Outdoor unit
installed higher

Highest
Indoor e Maximum height
MXZ-6D122VA2 units
a difference
Maximum Piping Length
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25m
Outdoor
Total length (a+b+c+d+e+f) 80m b unit Outdoor unit
|
Indoor unit
15m
Maximum Number of Bends c *Outdoor unit
installed lower Indoor unit
Outdoor unit - Indoor unit (a,b,c,d,e,f) 25 |
Indoor unit

Total number (a+b+c+d+e+f) 80 15m

Outdoor unit
Lowest
|
Indoor unit
10m
d f
*Outdoor unit
installed higher

35
External Dimensions
Wall-Mounted Unit : mm
MSXY-JS15/20/25/35VF MSZ-LN10/13/18VF MSZ-LN25/35VF MSXZ-LN25VF
INDOOR UNIT INDOOR UNIT

838
5
228

AIR IN INSTALLATION PLATE


(49.5) 677.5 111
PIPING

DRAIN HOSE

57
42
43

100

64 57 40
100
AIR OUT 170.5

179
58 19
159

MSXY-JS50VF MSZ-GE22/25/35/42/50VA
INDOOR UNIT INDOOR UNIT

923 798
785 6.5
7 909
5
262

AIR IN
Air in
INSTALLATION PLATE
232
PIPING 5
(53) 709 161 Installation plate
DRAIN HOSE Piping
18.5
100

295
65

100
8

65

69
56
65 65 116.5 42 Drain hose
AIR OUT
53
63

71

50 619 130
93
133 107
112
175.5 Air out
58 19 58 19
159

159

MSXY-JS60/71VF MSZ-GE60/71VA
INDOOR UNIT INDOOR UNIT

1100 1100
1090 5 1090 5

Air in Installation plate 238


Air in
Installation plate
5

Piping
325

Piping
325

67

67
12

12
100

100

65 65
3

76 843 181 76 843 181


3

( 70° ) 125 Drain hose ( 70 ) 125 Drain hose


160 160
Air out 184 Air out 184

58 19 60 18
193
159

36
4-way cassette Unit : mm
MLZ-KP25/35/VF
INDOOR UNIT

37
Ceiling-concealed Unit : mm
SEZ-KD25/35/50/60/71VAL
INDOOR UNIT 20 157.5
15 12 37 100 37

88
B (Suspension bolt pitch)
100X(E-1)=F

100XJ=K
D (Duct)

H
C
A
Air Air
outlet inlet

100
100

88
30
57

20
20

12
10 23 L- 2.9
2XE- 2.9
25

90

49 625 (Suspension bolt pitch) Air filter


Knockout hole 27
Suspension bolt hole
(Remote controller transmission line)
4-14X30 Slot

Refrigerant piping 700 Knockout hole 27


23 677 (Indoor/outdoor connecting line)
flare connection (liquid) Control box
10
23
25

102
150 (Duct)

170
100

200

2X2- 2.9 116 70 Terminal block

Refrigerant piping 270 Terminal block (Indoor/outdoor connecting line)


(Remote controller transmission line) Notes:
flare connection (gas)
Drain pipe(Spontaneous draining) 1. Use M10 bolts for suspension (purchase locally).
2. Keep service space for maintenance at the bottom.
Model A B C D E F H J K L 3. This chart is based on the SEZ-KD50VAL, which has three fans.
SEZ-KD25VAL 700 752 798 660 7 600 660 5 500 16 SEZ-KD25VAL and SEZ-KD35VAL have two fans,
SEZ-KD35VAL and SEZ-KD60VAL and SEZ-KD71VAL have four fans.
900 952 998 860 9 800 860 7 700 20
SEZ-KD50VAL 4. If an inlet duct is used, remove the air filter supplied with the unit,
SEZ-KD60VAL and install a locally purchased filter on the suction side.
1100 1152 1198 1060 11 1000 1060 9 900 24
SEZ-KD71VAL

SEZ-M25/35/50/60/71DA
SEZ-M25/35/50/60/71DAL
INDOOR UNIT
20 157.5
15 12 37 100 37
88
B (Suspension bolt pitch)
100X(E-1)=F

100XJ=K
D (Duct)

H
C
A

Air Air
outlet inlet
100
100

88
30
57

20
20

12
25

10 L- 2.9
23

2XE- 2.9
90

49 625 (Suspension bolt pitch) Air filter


Knockout hole 27
Suspension bolt hole
700 (Remote controller transmission line)
2 Refrigerant piping 4-14X30 Slot
23 677
flare connection (liquid) Control box Knockout hole 27
10
(Indoor/outdoor connecting line)
23
25

102
150 (Duct)

170
100

200

2X2- 2.9 116 70 Terminal block


1 Refrigerant piping 270 Terminal block (Indoor/outdoor connecting line)
(Remote controller transmission line)
flare connection (gas)
Drain pipe(O.D. 32)(Spontaneous draining)
Note
Model A B C D E F G H J K L 1 Gas pipe 2 Liquid pipe 1.Use M10 screw for the suspension bolt (field supply).
SEZ-M25DA(L)-PA 700 752 798 660 2.Keep the service space for the maintenance at the bottom.
7 600 800 660 5 500 16
9.52 3.This chart indicates for SEZ-M50DA(L)-PA model,which has 3 fans.
SEZ-M35DA(L)-PA
900 952 998 860 9 800 1000 860 7 700 20 6.35 SEZ-M25,35DA(L)-PA models have 2 fans.
SEZ-M50DA(L)-PA 12.7 SEZ-M60,71DA(L)-PA models have 4 fans.
SEZ-M60DA(L)-PA 4.In case an inlet duct is used,remove the air filter (supply with
1100 1152 1198 1060 11 1000 1200 1060 9 900 24 15.88
SEZ-M71DA(L)-PA 9.52 the unit), then install the filter (field supply) at suction side.

38
INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance, including the optimum control of operation frequency. As a result,
optimum power is applied in all cooling/heating ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and amazingly low running cost — That’s the Mitsubishi Electric promise.

INVERTERS – HOW THEY WORK


Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air
conditioner. They receive information from sensors monitoring operating conditions and adjust the rotation speed of the compressor, which
directly regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity
and providing the most comfortable room environment.

ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter-equipped air conditioners. We have combined advanced inverter technologies
with cutting- edge electronic and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling
performance efficiency. As a result, better performance and lower energy consumption are achieved.

TRUE COMFORT
Below is a simple comparison of air conditioner operation control with and without an inverter.

■ Inverter operation comparison

On/Off operation of compressor Optimum control of frequency


Non-inverter air conditioner Inverter air conditioner
keeps room temperature keeps preset room temperature
Change in room
temperature Full power Change in room
temperature
Minimum power
temperature

consumption
temperature
Preset

Preset

ON OFF ON OFF ON

getting too hot getting too cool Constant room temperature

Compressor operation Time Compressor operation Time

The compressors of air conditioners without an inverter start and stop repeatedly in order to maintain the preset room temperature.
This repetitive on/off operation uses excessive electricity and compromises room comfort. The compressors of air conditioners
equipped with an inverter run continuously; the inverter quickly optimizing the operating frequency according to changes in room
temperature. This ensures energy-efficient operation and a more comfortable room.

Point 1 Quick & Powerful Point 2 Room Temperature Maintained


Increasing the compressor motor speed by controlling the operation The compressor motor operating frequency and the change in room
frequency ensures powerful output at start-up, and brings the room temperature are monitored to calculate the most efficient waveform to
temperature to the comfort zone faster than units not equipped with an maintain the room temperature in the comfort zone. This eliminates the
inverter. Hot rooms are cooled, and cold rooms are heated, faster and large temperature swings common with non-inverter systems and
more efficiently. guarantees a pleasant, comfortable environment.

39
MORE ADVANTAGES WITH MITSUBISHI ELECTRIC
Joint Lap DC Motor Vector-Wave Eco Inverter
Mitsubishi Electric has developed a unique motor, This inverter monitors the varying compressor motor frequency and
called the “Poki-Poki Motor” in Japan, which is creates the most efficient waveform for the motor speed. As the
manufactured using a joint lapping technique. result, operating efficiency in all speed ranges is improved, less
This innovative motor operates based on a high- power is used and annual electricity cost is reduced.
density, high-magnetic force, leading to extremely Smooth wave pattern
Sine-wave drive soft PWM
high efficiency and reliability.
Inverter size has been reduced using insert-
molding, where the circuit pattern is molded into
the synthetic resin. To ensure quiet operation,
soft PWM control is used to prevent the metallic
Magnetic Flux Vector Sine Wave Drive whine associated with conventional inverters.

This drive device is actually a microprocessor that converts the com-


pressor motor’s electrical current waveform from a conventional wave-
form to a sine wave (180°conductance) to achieve higher efficiency by
raising the motor winding utilisation ratio and reducing energy loss. PAM (Pulse Amplitude Modulation)
PAM is a technology that controls the current waveform so that it
resembles the supply voltage wave, thereby reducing loss and real-
Reluctance DC Rotary Compressor ising more efficient use of electricity. Using PAM control, 98% of the
input power supply is used effectively.
Powerful neodymium magnets are used in the rotor of the reluc-
tance DC motor. More efficient operation is realised by strong mag-
netic and reluctance torques produced by the magnets. Without PAM control With PAM control
Supply
voltage

Time
DC compressor Neodymium Current Time
motor ( rotor ) magnets

PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.

Magnetic torque
+ ■ Merits of PAM Control Power increased
Reluctance torque Efficient voltage increase
realises increased power
Significant energy savings PAM
Remarkable reduction in power
Heat Caulking
Fixing Method Heat Caulking Fixing Method loss saves electricity Conventional
inverter
To fix internal parts in place, a “Heat Caulking
Fixing Method” is used, replacing the former arc Limited power
spot welding method. Distortion of internal parts Limited energy savings Insufficient power
Electricity is wasted when needed
is reduced, realising higher efficiency.

DC Fan Motor Power Receiver and Twin LEV Control


A highly efficient DC motor drives the fan of the outdoor unit. Mitsubishi Electric has developed a power receiver and twin linear
Efficiency is much higher than an equivalent AC motor. expansion valves (LEVs) circuit that optimise compressor perfor-
mance. This technology ensures optimum control in response to op-
erating waveform and outdoor temperature. Operating efficiency has
been enhanced by tailoring the system to the characteristics of R410A
refrigerant.

Heat Compressor
exchanger

Power Heat
receiver exchanger
LEV1 LEV2

Grooved Piping Grooved piping

High-performance grooved piping


is used in heat exchangers to in-
crease the heat exchange area. Pipe image
Cross-sectional view

40
FUNCTIONS (1)
3D i-see SENSOR
Area Temperature Monitor
Cooling mode
The “3D i-see Sensor” monitors the whole room in sections
and directs the airflow to areas of the room where the tempera- Warmer Cooler
Daytime Nighttime area
area
ture does not match the temperature setting. (When cooling the
room, if the middle of the room is detected to be hotter, more
airflow is directed towards it.) This eliminates unnecessary
heating /cooling and contributes to lower electricity costs.

ENERGY-SAVING
Econo Cool Energy-Saving Feature Econo Cool Mode
A comfortable room environment is maintained even when setting the
“Econo Cool” is an intelligent temperature control feature that adjusts temperature 2°C higher than the conventional cooling mode.
the amount of air directed towards the body based on the air-outlet Econo Cool on Conventional cooling mode
temperature. The setting temperature can be raised by as much as
2°C without any loss in comfort, thereby realising a 20% gain in
energy efficiency. (Function only available during manual cooling operation.)
Conventional Econo Cool
Ambient temperature 35°C 35°C
Set temperature 25°C 27°C
Perceived temperature 30°C 29.3°C Temperature distribution (°C)

14 16 18 20 22 24 26 28

AIR QUALITY
Nano
Plasma Quad Plus Platinum Nano Platinum Filter
Plasma Quad Plus is a plasma-based filter system similar to Plasma The filter has a large capture area and incorporates nanometre-sized
Quad, but in addition to bacteria, viruses, allergens, and dust, it can platinum-ceramic particles that work to eliminate bacteria and de-
also filter out microparticles such as PM2.5. odourise the circulating air.

Dual Barrier
Coating Dual Barrier Coating Micro Particle
Catching Micro Particle Catching Filter
A two-barrier coating which prevents hydrophobic and hydrophillic The filter effectively catches floating PM2.5 particle to maintain
dirt from sticking to the inner surface and inner parts of the indoor clean air in the room.
unit.

Anti-allergy Enzyme Filter Catechin Filter


The anti-allergy enzyme filter works to trap allergens such as molds Catechin is a bioflavonoid by-product of green tea with both antiviral
and bacteria and decompose them using enzymes retained in the and antioxidant qualities. It also has an excellent deodorising effect,
filter. which is why Mitsubishi Electric uses the compound in its air condi-
tioner filters. In addition to improving air quality, it prevents the
spreading of bacteria and viruses throughout the room. Easily re-
Electrostatic
Anti-allergy Electrostatic Anti-allergy Enzyme Filter moved for cleaning and maintenance, when the filter is washed regu-
larly the deodorising action is rated to last more than 10 years.
This function features both the Air Cleaning Filter and Anti-allergy
Enzyme Filter.

41
AIR DISTRIBUTION
Horizontal Vane High Ceiling Mode
The air outlet vane swings up and down so that the airflow is spread In the case of rooms with high ceilings, the outlet-air volume can be
evenly throughout the room. increased to ensure that air is circulated all the way to the floor.

Vertical Vane Auto Fan Speed Mode


The air outlet fin swings from side to side so that the airflow reaches The airflow speed mode adjusts the fan speed of the indoor unit
every part of the room. automatically according to the present room conditions.

Powerful Cool
Once activated, powerful cool mode continues for 15 minutes cooling
starts immediately with the push of a button.

Wide and Long Airflow


The wide and long airflow function is especially beneficial for large spaces, helping to ensure that air is well circulated and reaches every corner
of the room.

CONVENIENCE
On/Off Operation Timer
Use the remote controller to set the times of turning the air conditioner On/Off.

“i save” Mode/Smart Set


“i save” is a simplified setting function that recalls the preferred (preset) temperature by pressing a single button on the remote controller.
Smart Set : Press the same button twice in repetition to immediately return to the previous temperature setting.
Using this function contributes to comfortable waste-free operation, realising the most suitable air conditioning settings and saving on power
consumption when, for example, leaving the room or going to bed.

Ampere Limit Adjustment Low-noise Operation (Outdoor Unit)


Dipswitch settings can be used to adjust the maximum electrical System operation can be adjusted to prioritise less noise from the
current for operation. This function is highly recommended for outdoor unit over air conditioning performance.
managing energy costs.
*Maximum capacity is lowered with the use of this function.

Auto Restart Auto Changeover


Especially useful at the time of power outages, the unit turns back on The air conditioner automatically switches between heating and cool-
automatically when power is restored. ing modes to maintain the desired temperature.

Sleep Mode
Once activated, this mode slightly lowers temperatures to support body to release heat, and auto matically returns to original setting temperatures
after 120 minutes.

42
FUNCTIONS (2)
CONVENIENCE
Built-in Weekly Timer Function
Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
■ Example Operation Pattern (Winter/Heating mode)
Mon. Tues. Wed. Thurs. Fri. Sat. Sun.
ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C
Automatically changes to high-power operation at wake-up time

OFF OFF OFF OFF OFF ON 18°C ON 18°C


Midday is warmer,
Automatically turned off during work hours so the temperature is set lower

ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C ON 20°C


Automatically raises temperature setting to
Automatically turns on, synchronized with arrival at home match time when outside-air temperature is low
(during sleeping hours)
ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C ON 18°C
Automatically lowers temperature at bedtime for energy-saving operation at night

Pattern Settings: Input up to four settings for each day


Settings
Settings: • Start/Stop operation • Temperature setting ✽ The operation mode cannot be set.

Back Light
Remote
Back Light Remote Controller
Not only the indoor units, but the wireless remote controllers come in four colours as well. Each remote controller
matches the indoor unit. Even the textures are the same.

The setting can be easily


checked in the dark.

43
INSTALLATION
Wiring/Piping Correction Function*
The push of a single button is all that is required to confirm that Wiring
confirmation
piping and wiring are properly connected. Corrections are made au- is time
The outdoor unit
matches
tomatically if a wiring error is detected, eliminating the need for com- consuming. pipes and wiring.

plicated wiring confirmation work when expanding the number of


rooms served.
* This function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10 –20 minutes, and only works when the unit is set
to the Cooling mode.

Drain Pump Flare Connection


A built-in drain pump enables drain piping to be raised. Flare connection to cooling pipe work is possible.

MAINTENANCE

Easy Clean
The cover panel can be quickly removed for washing and the airflow vents can be opened without any special tools, making it easy to clean the
inside of the air conditioner in minutes. Periodic cleaning of the air conditioner is recommended to maintain optimum operating efficiency and
energy savings.

Self-Diagnostic Function (Check Code Display) Failure Recall Function


Check codes are displayed on the remote controller or the operation Operation failures are recorded, allowing confirmation when needed.
indicator to inform the user of malfunctions detected.

BLUE
FIN Blue Fin condenser
A special coating is applied to the heat exchanger to increase
corrosion toughness.

44
FUNCTION LIST Indoor unit
MSZ-LN (10/13/18, 25/35)
Category MSXZ-LN (25)
Outdoor Unit MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H
DC Inverter
Joint Lap DC Motor
Reluctance DC Rotary Compressor
Technology Heating Caulking (Compressor)
DC Fan Motor
PAM (Pulse Amplitude Modulation)
Grooved Piping
Felt Temperature Control (3D i-see sensor)
i-see sensor
AREA Temperature Monitor
Energy-Saving Econo Cool
Plasma Quad Plus
Dual Barrier Coating
Electrostatic Anti-allergy Enzyme Filter
Air Quality
Micro Particle Catching Filter
Anti-allergy Enzyme Filter
Nano Platinum Filter
Powerful Cool
Horizontal Vane
Vertical Vane
Air Distribution
High Ceiling Mode
Auto Fan Speed Mode
Functions
Long Airflow (12m)
On/O Operation Timer
"i save" Mode
Auto Restart
Convenience Low-noise Operation (Outdoor Unit)
Sleep Mode
Ampere Limit Adjustment
Built-in Weekly Timer Function
Wiring/Piping Correction Function
Installation Drain Pump
Flare Connection
Self-Diagonosis Function (Check Code Display)
Maintenance Failure Recall Function
Blue-Fin condenser

MSZ-GE (22/25/35/42/50/60/71)
Indoor unit
Category
Outdoor Unit MXZ-2D MXZ-3E MXZ-4E MXZ-5E MXZ-6D
DC Inverter
Joint Lap DC Motor
Reluctance DC Rotary Compressor 83
Heating Caulking (Compressor)
Technology
DC Fan Motor
PAM (Pulse Amplitude Modulation)
Power Receiver and Twin LEV Control 72
Grooved Piping
Energy-saving Econo Cool Energy-saving Feature
Anti-allergy Enzyme Filter Opt22-50 Opt22-50 Opt22-50 Opt22-50 Opt22-50
Electrostatic Anti-allergy Enzyme Filter Opt60/71 Opt60/71 Opt60/71 Opt60/71
Air Quality
Catechin Filter 22-50 22-50 22-50 22-50 22-50
Nano Platinum Filter 60/71 60/71 60/71 60/71
Horizontal Vane
Vertical Vane 60/71 60/71 60/71 60/71
Air Distribution
Auto Fan Speed Mode
Wide and Long Airflow 60/71 60/71 60/71 60/71
On/O Operation Timer
"i save" Mode / Smart Set
Auto Changeover *1 *1 *1 *1 *1
Functions
Auto Restart
Convenience Low-temperature Cooling
Low-noise Operation (Outdoor Unit)
Ampere Limit Adjustment 83
Operation Lock
Built-in Weekly Timer Function
Wiring/Piping Correction Function
Installation Drain Pump
Flare Connection
Easy Clean
Maintenance Self-Diagonosis Function (Check Code Display)
Failure Recall Function
*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.

45
MSXY-JS (15/20/25/35/50/60/71) MLZ-KP (25/35) SEZ-M (25/35/50/60/71)

MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H MXY-2H MXY-3H MXY-4H76 MXY-4H92 MXY-5H

Opt. Opt. Opt. Opt. Opt.


Opt. Opt. Opt. Opt. Opt.
Opt. Opt. Opt. Opt. Opt.

50/60/71 50/60/71 50/60/71 50/60/71 50/60/71

50/60/71 50/60/71 50/60/71 50/60/71 50/60/71

Opt Opt Opt Opt Opt

SEZ-KD(25/35/50/60/71)

MXZ-2D MXZ-3E MXZ-4E MXZ-5E MXZ-6D

83

72

*1 *1 *1 *1 *1

83

Opt Opt Opt Opt Opt

46
Doing Our Part to
Create a Better Future for All...
Core Environmental Policy
The Mitsubishi Electric Group promotes sustainable development and is committed to protecting and restoring the global
environment through technology, through all its business activities, and through the actions of its employees.

Environmental Vision 2021

Making Positive Contributions to the Earth


and its People through Technology and Action

Preventing Global Warming Creating a Recycling-Based Society

Ensuring Harmony with Nature Fostering Environmental Awareness

NEW The New Refrigerant R32


The new R32 refrigerant has a global warming potential approximately 1/3*1 that of our current refrigerant, R410A; thereby dramatically
reducing the negative impact more than ever. Actively introducing the new R32 refrigerant to suppress global warming, Mitsubishi Electric
continues to promote manufacturing while considering the environment.

Comparison of Global Warming Potential


Global warming
2088 potential approx.
1 *1
3
675

R410A R32
*1 Source: IPCC 4th Assessment Report, global warming potential (GWP) 100-year value.
Comparison of 2088 (R410A) and 675 (R32).

47
R32 REFRIGERANT

R32 REFRIGERANT PROPERTIES


Under the conditions shown below, there is a possibility that R32 could ignite.

a) Leakage Ignition

b) Concentration c) Ignition
*5 source

R32 R410A R22


Chemical formula CH2F2 CH2F2/CHF2CF3 CHClF2
Composition Single composition R32/R125 Single composition
(blend ratio wt. %) (50/50 wt %)
Ozone depletion potential (ODP) 0 0 0.055
Global warming potential (GWP) *1 675 2088 1810
LFL(vol.%) *2 13.3 – –
UFL(vol.%) *3 29.3 – –
Flammability *4 Lower flammability (2L) No flame propagation (1) No flame propagation (1)

*1 IPCC 4th assessment report.


*2 LFL : Lower flammable limit
*3 UFL : Upper flammable limit
*4 ISO 817:2014
*5 R32 consistency is higher than LFL*1 and lower than UFL*2.

Although R32 is classified as low flammability, the possibility of igniting can be eliminated by ensuring the following three points.

a) Do not leak refrigerant.


<Installation> ·Vacuum drying should be done. Air purging is prohibited.
·Follow “4. Installation Points of Refrigerant Piping Work”.
<Repair/Relocation/Removal> ·Pump down or recovering refrigerant should be done.

b) Prevent concentration.
·Ventilate during installation and servicing, such as open the door or window and use a fan.
·Follow “2. Installation Restrictions”.

c) Keep ignition source away from the unit.


·Do not braze pipe and unit which contain refrigerant. Before brazing, refrigerant should be recovered.
·Do not install unit while the electricity is turned on. Turn off electricity at the fuse box and check the wiring using a tester.
·Do not smoke when working or during transportation of the product.

Note Both R32 / R410A emit a toxic gas when coming into contact with an open flame.

48
Reliability
Facts
Always Quality First
Cutting-edge technologies and uncompromising commitment to quality and reliability have made
Mitsubishi Electric one of the world’s most trusted brands in air-conditioning and refrigeration equipment
and service.

DEVELOPMENT
Combustion Test
Products are subjected to a wide range
of tests including combustion testing and
salt damage testing - all to confirm safe
operation under a variety of conditions.
Combustion testing is done by assuming
accidental firing and replicating abnormal
conditions that cause breakage of pressure
components.

Combustion testing Explosion-proof chamber

Shock Resistance
On the assumption of many different kinds
of logistics environments in the world,
we perform drop/strength tests, transport
vibration tests, and many other product
checks to assure that the quality and per-
formance are maintained when the prod-
uct reaches the user's home.

Drop/strength testing Transport vibration testing

Waterproof Test Operation Noise Test


Since the outdoor unit is subject to rain and wind, potential problems Operation noise tests are performed in an anechoic chamber
are checked by tests such as showering the unit for a certain amount with an extremely low 10dB of background noise. This is just
of time. one of the ways Mitsubishi Electric ensures its customers enjoy
extremely calm environments with a quiet operation noise
(sound pressure level).

Anechoic chamber

49
DESIGN
Designed to create and
maintain a comfortable environment
To improve the quality of our products, the engineers strive to
achieve its philosophy of combining ecology and comfort to an
even higher level. Therefore, we are working to further improve
quality at all stages from development to production.

PRODUCTION
Each and every unit is checked and double-checked by experienced professionals
Every air conditioner goes through rigorous electrical inspection on the manufacturing line. In final testing, our experienced inspectors listen
for even the faintest operation noise to detect any fault.

50
OPTIONAL
PARTS
Option Filter

Quick System
Anti-allergy Softdry Drain
Electrostatic Anti-allergy Enzyme Micro Particle Deodorizing Clean Control
Enzyme Cloth Pump
Filter Catching Filter Filter Kit Interface
Filter

PAC-
MAC- MAC- MAC- MAC- MAC- MAC- MAC- MAC- MAC- MAC-
KE07
Indoor Unit Model Name 2320FT 2320FT-E 2310FT-E 408FT-E EMF515FT EMF615FT 3010FT-E 093SS-E 1001CL-E 334IF-E
Outdoor unit Model Name DM-E

MSXZ-LN25VFR
MSZ-LN25VF)(V)(R)(B)
MSZ-LN35VF(V)(R)(B)
MSZ-LN10VF(V)(R)(B)
MSZ-LN13VF(V)(R)(B)
MSZ-LN18VF(V)(R)(B)
MSXY-JS15VF
MSXY-JS20VF
MSXY-JS25VF
Wal - MSXY-JS35VF
Mounted MSXY-JS50VF
MSXY-JS60VF
MSXY-JS71VF
MSZ-GE22VA
MSZ-GE25VA
MSZ-GE35VA
MSZ-GE42VA
MSZ-GE50VA
Indoor
MSZ-GE60VA
Unit
MSZ-GE71VA
1-way MLZ-KP25VF
Cassette MLZ-KP35VF
SEZ-M25DA
SEZ-M35DA
SEZ-M50DA
SEZ-M60DA
SEZ-M71DA
SEZ-M25DAL
SEZ-M35DAL
Ceiling -
SEZ-M50DAL
concealed
SEZ-M60DAL
SEZ-M71DAL
SEZ-KD25VAL
SEZ-KD35VAL
SEZ-KD50VAL
SEZ-KD60VAL
SEZ-KD71VAL
MXY-2H50VF
MXY-3H65VG
MXY SERIES
MXY-4H76VG
(R32)
MXY-4H92VG
MXY-5H105VG
Outdoor
MXZ-2D53VA2
Unit
MXZ-3E68VA
MXZ SERIES MXZ-4E72VA
(R410A) MXZ-4E83VA
MXZ-5E102VA
MXZ-6D122VA2

51
Joint Pipe
MA& Connector
Remote Remote
Contract Connector Remote Cable for Unit Unit Unit Unit Unit Drain M-NET
On/O Operation Air Outlet Guide
Terminal Cable Sensor Remote 9.52 6.35 9.52 12.7 12.7 Socket Adapter
Adapter Adapter
Interface Display --> --> --> --> -->
Pipe Pipe Pipe Pipe Pipe
15.88 9.52 12.7 9.52 15.88

Flare
PAC- PAC- PAC- PAC- MAC- MAC- PAC- PAC- PAC-
MAC- MAC- MAC- PAC- PAC- MAC- MAC- MAC-
SE41 SE55 SF40 SF40 889 856 SH96 SG60 IF01
397IF-E 1702RA-E 1710RA-E SG76 493 A454 A455 A456
TS-E RA-E RM-E RM SG SG SG-E DS-E MNT-E
RJ-E PI JP-E JP-E JP-E

52
NOTICE
■ Do not install indoor units in areas (e.g. mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ Our air-conditioning equipments and heat pumps contain a fluorinated greenhouse gas, R410A (GWP: 2088) or
R32 (GWP: 675). *These GWP values are based on Regulation (EU) No.517/2014 from IPCC 4th edition. In case of
Regulation (EU) No.626/2011 from IPCC 3rd edition, these are as follows. R410A (GWP: 1975), R32 (GWP: 550)
■ When installing or relocating or servicing our air-conditioning equipment, use only the specified refrigerant (R410A or R32)
to charge the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

https://www.mitsubishielectric.com/

New publication effective Mar. 2021.


2002785-1-3<IP> Specifications are subject to change without notice.