深圳市盈科互动科技有限公司 CWT CO.

, LIMITED
TEL:+86-755-26719954 | www.comwintop.com

CWT-UWD-SD
RS485 Ultrasonic Wind Speed and Direction Sensor

Product description
The small ultrasonic wind speed and direction sensor is a wind speed and direction measuring instrument
developed based on the ultrasonic principle. It uses the transmitted sound wave pulse to measure the phase
difference at the receiving end to calculate the wind speed and wind direction. The sensor can
simultaneously measure the instantaneous value of wind speed, wind direction。It is widely used in wind
speed and wind direction measurement in the fields of meteorology, ocean, environment, airport, port,
laboratory, industry, agriculture and transportation.

Features
 No angle limit, can measure wind speed and direction data at the same time
 No moving parts, low wear and long service life
 Using random error identification technology, it can ensure low discrete error of measurement even
under strong wind, making the output more stable
 Adopt ABS engineering plastic case, light design, easy to install and disassemble
 The product adopts 485 communication interface, standard Modbus-RTU communication protocol,
communication address and baud rate can be setting, the longest communication distance is 2000m
 No maintenance and field calibration

Page: 1 Version: V1.0


深圳市盈科互动科技有限公司 CWT CO., LIMITED
TEL:+86-755-26719954 | www.comwintop.com

Technical parameter
DC power Supply 10-30vdc
Maximum power consumption 0.12W (12V)
Wind speed 0-40m/s
Measuring range
Wind direction 0-360 °
Wind speed ±0.5+2%FS
Precision
Wind direction ±3°
Wind speed 0.01 m/s
Resolution
Wind direction 1°
Working environment -40~80℃,0~95%RH
Wind resistance 75 m/s
Respond time 1s
Protection level IP65
Output RS485 (Modbus RTU protocol)

Size and installation

Page: 2 Version: V1.0


深圳市盈科互动科技有限公司 CWT CO., LIMITED
TEL:+86-755-26719954 | www.comwintop.com

Wiring
Cable color Description
Brown DC10-30V)
black GND
green RS485 A+
blue RS485 B-

RS485 communication
Default parameters: 4800,n,8,1
Default device address is 1
Modbus RTU protocol

Read status registers, read function code: 0x30


Register PLC
Number
address Address meaning content remark
of bytes
(Hex) (decimal)
0000 40001 Wind speed 2 0.01m/s
0° corresponds to North,
0001 40002 Wind direction 2 1° Increase degrees clockwise
90° corresponds to East
0002 40003 Max Wind speed 2 0.01m/s
0003 40004 Wind level 2 1 0-17 level

Page: 3 Version: V1.0


深圳市盈科互动科技有限公司 CWT CO., LIMITED
TEL:+86-755-26719954 | www.comwintop.com

Parameters registers, read function code: 0x30 (0x40), write function code: 0x60
07D0 42001 Slave ID 2 1-254
0: 2400 1:4800 2:9600
07D1 42002 baud rate 2
Default 4800

E.g., read wind speed and wind direction:


Master sends

Number Number
Start Start Error Error
Function of of
Address Address Address Check Check
Code Points Points
(Hi) (Lo) (Lo) (Hi)
(Hi) (Lo)
0x01 0x03 0x00 0x00 0x00 0x02 0xC4 0x0B

Sensor responds:
Error Error
Function Number of Wind
Address Wind speed Check Check
Code byte direction
(Lo) (Hi)
0x00 0x00
0x01 0x03 0x02 0xBF 0x06
0x7D 0x5A

Wind speed: 7D H= 125 => Wind speed = 1.25m/s

Wind direction:5A H= 90 => Wind direction = east wind

E.g., read wind level:


Master sends

Number Number
Start Start Error Error
Function of of
Address Address Address Check Check
Code Points Points
(Hi) (Lo) (Lo) (Hi)
(Hi) (Lo)
0x01 0x03 0x00 0x04 0x00 0x01 0xC5 0xCB

Sensor responds:
Error Error
Function Number of
Address Wind level Check Check
Code byte
(Lo) (Hi)
0x01 0x03 0x02 0x00 0x01 0x79 0x84

Wind level: 1 H= 1 => Wind level = 1

Page: 4 Version: V1.0


深圳市盈科互动科技有限公司 CWT CO., LIMITED
TEL:+86-755-26719954 | www.comwintop.com

Set slave ID
E.g., set slave ID=2, Master sends
Start Start Error Error
Function
Address Address Address ID Check Check
Code
(Hi) (Lo) (Lo) (Hi)
0x01 0x06 0x07 0xD0 0x00 0x02 0x08 0x86

Sensor responds:

Start Start Error Error


Function
Address Address Address ID Check Check
Code
(Hi) (Lo) (Lo) (Hi)
0x01 0x06 0x07 0xD0 0x00 0x02 0x08 0x86

Set baud rate


E.g., set baud rate to 9600, Master sends
Start Start Error Error
Function
Address Address Address command Check Check
Code
(Hi) (Lo) (Lo) (Hi)
0x01 0x06 0x07 0xD1 0x00 0x02 0x59 0x46

Sensor responds:
Start Start Error Error
Function
Address Address Address command Check Check
Code
(Hi) (Lo) (Lo) (Hi)
0x01 0x06 0x07 0xD1 0x00 0x02 0x59 0x46

Enquiry slave ID
Master sends
Number Number
Start Start Error Error
Function of of
Address Address Address Check Check
Code Points Points
(Hi) (Lo) (Lo) (Hi)
(Hi) (Lo)
0xFF 0x03 0x07 0xD0 0x00 0x01 0x91 0x59

Sensor responds:
Number Error Error
Function
Address of address Check Check
Code
Points (Lo) (Hi)
0xFF 0x03 0x02 0x00 0x01 0x50 0x50

Page: 5 Version: V1.0