APPENDIX E SIZING OF WATER PIPING SYSTEM

TABLE E103.3(2)
LOAD VALUES ASSIGNED TO FIXTURES(a)
Load Values, in Water Supply Fixture
Type of Supply
Fixture Occupancy Units (wsfu)
Control
Cold Hot Total
Bathroom group Private Flush tank 2.7 1.5 3.6
Bathroom group Private Flushometer valve 6.0 3.0 8.0
Bathtub Private Faucet 1.0 1.0 1.4
Bathtub Public Faucet 3.0 3.0 4.0
Bidet Private Faucet 1.5 1.5 2.0
Combination fixture Private Faucet 2.25 2.25 3.0
Dishwashing machine Private Automatic — 1.4 1.4
Drinking fountain Offices, etc. 10 mm valve 0.25 — 0.25
Kitchen sink Private Faucet 1.0 1.0 1.4
Hotel,
Kitchen sink Faucet 3.0 3.0 4.0
restaurant
Laundry trays (1 to 3) Private Faucet 1.0 1.0 1.4
Lavatory Private Faucet 0.5 0.5 0.7
Lavatory Public Faucet 1.5 1.5 2.0
Service sink Offices, etc. Faucet 2.25 2.25 3.0
Shower head Public Mixing valve 3.0 3.0 4.0
Shower head Private Mixing valve 1.0 1.0 1.4
25 mm flushometer
Urinal Public 10.0 — 10.0
valve
20 mm flushometer
Urinal Public 5.0 — 5.0
valve
Urinal Public Flush tank 3.0 — 3.0
Washing machine (4
Private Automatic 1.0 1.0 1.4
kg)
Washing machine (4
Public Automatic 2.25 2.25 3.0
kg)
Washing machine (7
Public Automatic 3.0 3.0 4.0
kg)
Water closet Private Flushometer valve 6.0 — 6.0
Water closet Private Flush tank 2.2 — 2.2
Water closet Public Flushometer valve 10.0 — 10.0
Water closet Public Flush tank 5.0 — 5.0
Public or
Water closet Flushometer tank 2.0 — 2.0
private
a. For fixtures not listed loads should be assumed by comparing the fixture to one listed using water in similar
quantities and at similar rates. The assigned loads for fixtures with both hot and cold water supplies are given
for separate hot and cold water loads and for total load. The separate hot and cold water loads being three-
fourths of the total load for the fixture in each case.