Aqueduct Design U Beam1
Aqueduct Design U Beam1
0.9M 0.75M
DESIGN OF AQUEDUCT
Ref: TREASURE OF R.C.C DESIGNS PAGE NO: 1139
0.15M
INPUT
Hight of beam Hb 0.9 M
Hight of water hw 0.75 M
Clear wide of Aqueduct Lx 0.9 M
Clear Span of Aqueduct Ly 4M
Depth of slab ds 150 mm
Wide of beam b 150 mm
Density of concrete wc 25 KN/m3
Density of water ww 10 KN/m3
Grade of Concrete σck 20 Mpa бcbc 7 Mpa
Grade of steel σy 415 Mpa бst 240 Mpa
Ref: Reinforced Concrete limite state design (Ashok k. Jain), pages: (from527 to 530)
q Q
a
h2
P1 Stone masonry
H P2 P
h1
h/3 W R
x1 X2
e
b
Fmin
Fmax
A. Data Input:
B. Design Calculation:
1) Safety Factor Against Sliding (SFS)= ( μ*Weight of Wall)/(Active Pressure of Soil)
ie (SFO) = MR/Mo
Where,
x1= (a2+ab+b2)/3(a+b)
x1= 0.47 m
MR = 33.40 KNm
Where,
Ecccentricity (e) = x1+x2-b/2
x1= (a2+ab+b2)/3(a+b)= 0.47
x2= (Pa*h)/3*Ww 0.32
(e) = e=x1+x2-b/2 0.188
Note:
x1+x2= (Taking moment of all forces above point toe and dividing by the total vertical forces ie x meter)
(Wt of wall/base width of wall) x(1+6e/base width of wall) = pressure at toe < given soil bearing presuure, OK
(Wt of wall/base width of wall) x(1-6e/base width of wall) = pressure at heel < given soil bearing presuure, OK
0)
KN/m2
KN/m3
KN/m3
m
m
m
KN/m2
KN/m2
45.54 Kn
12.112 Kn
14.63 Kn
4.45 Kn
19.08 Kn
Safe
Safe
m
m
m
Safe
Safe