WR5840A

KNOW YOUR PUREIT REVITO PRIME 10

Revito





01. Storage Tank Indicator 06. Inlet Water Tube


02. ESF (GKK-1) Life Indicator 07. Ball Valve Diverter
03. GKK (GKK-2) Life Indicator 08. Waste Water Tube
04. UV Status Indicator 09. Water Tap
Device image is for representation purpose only, actual design may vary. 05. Compound Sediment Filter (GKK-1) 10. Electrical Outlet
Assembly

1
UNIQUE FEATURES UNIQUE TECHNOLOGY

DURAVivaTM Best-In-Class# Filtration Technology

WQA certified component


Independently tested for heavy metal removal*

Maximum~~ purified water up to 8000 litres


As compared to 6000 litres from other leading RO's

Maximum water saving up to 70%


Delivers efficient purification to give a high water recovery rate of up to 70%^^.

Mineral enriched water


Enriches water with essential minerals like Calcium & Magnesium. 100% RO. No bypass

7
7 Stage Purification Technology with RO+UV-LED+MF 1. External Sediment Filter
To ensure you get safe drinking water with multistage protection. Removes fine and coarse particulate impurities/dirt and improves the life of the Carbon Filter.

2. Pre-RO Carbon Filter


In-tank UV Sterilization*** Removes chlorine and organic impurities like harmful pesticides. It also absorbs bad taste and odour causing
organic compounds from water.
Kills up to 99.9% bacteria, virus & cyst with in-tank UV LED.
3. Mesh Filter
Filters water further to ensure removal of finer particulate impurities.
Smartsense Indicators
Advance alert warns you 15 days** before filter expiry and auto shut off stops water if filter is TM
4. Reverse Osmosis Membrane
not changed, providing safe & sweet water. Removes bacteria and viruses causing water borne diseases like Typhoid, Jaundice, Diarrhea etc.

High Water Storage Capacity 5. Post Carbon Filter


8 8-litres$ in-built storage tank ensures you and your family never run out of fresh & safe RO Acts as a polisher and enhances the taste of purified water.
water.
6. Microfiltration Membrane
Microfiltration Membrane acts as an additional filtration stage to remove bacteria.
28 L/HR Maximum Purification Speed
$$
of Up To 28 Litres/hour^^
(Highest among leading RO’s) 7. UV-LED
Super-sized 175G ROM enables device to quickly fill the tank (8L) only in 20 minutes. Inactivates upto 99.99% harmful disease causing bacteria and viruses to deliver safe drinking water.

Membrane Protector
Ensures that the RO membrane lasts long and protects components from scaling, foul smell &
contaminations.

USEPA Compliant##
Meets the tough safety standards by removing 1 crore virus and 10 crore bacteria from 1 L water.

100% Food Grade Plastic~


Prevents harmful toxins from leaching into water. Get a corrosion free safe drinking experience.

7.5 to 8 litres
#* This RO membrane is tested and certified by WQA to NSF/ANSI 58 for material safety only. This RO membrane was Pureit Revito has highest purification rate across filters life when compared to leading RO brand (Kent Supreme
tested by WQA in a surrogate system for the reduction of Cadmium, Chromium III. WQA cannot confirm that the
component will yield the same performance when used in any other, non-tested system. Extra) - Under test condition, input TDS - 750 ppm, Turbidity - <1 NTU, input Pressure - 0.06 MPa, Input Hardness - 300 ppm,
See WQA.org for details. Environment Temp. and Water Temp. - 25°C.
#
~~
In comparison to leading RO devices, in comparison to life of RO membrane.
In the segment versus comparable products.
^^
0.06 MPa
Environment Temp. and Water Temp. - 25°C
Advance Alert System will alert you of replacing External Sediment Filter 15 days before or 15 hours before
completion of every 225 hours of pump running time. It will also alert you of replacing ESF & GKK every 435 hours
of pump running time.

2
INSTALLING YOUR PUREIT REVITO PRIME Water Tank Cleaning

1. The purifier should be installed by a trained Pureit technician. The water tank in this product is recommended to be disinfected every 60 days.
The disinfectant tablets or solution can be purchased from an authorized dealer of Pureit.
2. The purifier should be wall-mounted. The disinfecting process defined below must be strictly followed:

3. The purifier should be placed in area which is free of ants/insects/other pests. Close the inlet ball valve on the product to suspend water supply.
Power off the product and unplug the power cable. Turn on the faucet to
4. The purifier should be placed close to the plumbed inlet connection (not more purge all residual water in the water tank. Dismount the product.
Uninstall the front panel or take off the knob from the top cover.
than 1.5 metres).
Add disinfectant into the water tank.
4. Reinstall the front panel or the knob on the top cover.
5. Do not install the purifier above any electric socket.
5. Mount the product and open the inlet ball valve to resume water supply. Plug in
6. Avoid sharp bends to the pipes of the product. the power cable, power on the product and wait until the purifier has produced a tank
full of water. Keep this water in the tank for 30 minutes then discard it completely.
6. Let the water tank be filled for the second time, then again, discard the water.
7. Do not use an extension cord.
The produced water should now be safe to consume.
7. If any abnormal smell or odor is detected in the produced water, discard all of it and
8. Before installing the purifier please check the inlet pressure.
repeat the water purging and replenishing process described above until no smell or
9. Make sure you test the input water TDS (Total dissolved salts) before installing odor is observed.
the purifier. The maximum input TDS should not exceed 2000 ppm. Note: it is highly recommended to order the cleaning service through our helpline and let
our authorized technician to perform the disinfecting operation at nominal cost.
10. Do not connect the purifier to any hot water tap.

11. Please do not terminate the reject line tubing directly into the drainage (keep it
hanging over the drainage).

12. Do not place the unit where it will be exposed to freezing and/or direct sunlight
and ensure there is enough ventilation.

TAKING CARE OF YOUR PUREIT REVITO PRIME Revito Prime Revito Prime

1. Clean the tap nozzle using disinfectants like bleach/hypochlorite (50 PPM
available chlorine). Discard 2 litres of water after cleaning the dispenser.
 

 

2. Clean the external portion of the purifier using a dry cloth only. Do not use
any detergent or soap.
3. Do not clean aggressively or rub the surface as this might lead to scratches
on the parts.
4. Never splash water on the purifier while cleaning.
5. Do not try to open the purifier for cleaning or for any replacements. This
can be done only by a qualified company personnel or an authorised agent.
6. You should maintain good hygiene in the area around your water purifier.
Ensure that this area is free of ants/insects/other pests.
7. Do take care of the reject line and other tubes while cleaning the purifier
else water can flow into the kitchen.
3

3
In the process of 100% purification through RO membrane, TDS reduction is up to
FACTS ON WATER QUALITY PARAMETERS AND
90% and thus the purified water may have only 10% of TDS when compared to
FILTER PERFORMANCE: feed water. Leading international and national organizations like WHO, USEPA,
Feed water or source water of purifier to be tested for TDS and pH before BIS, that formulate the guidelines for drinking water and other different types of
installation of purifier. water, have clarified the upper limit for TDS being 500 ppm but have not
mentioned the minimum level of TDS for drinking water. This is also because
The external sediment filter needs to be flushed (before connecting to purifier water is not the only source for TDS, the food we eat is rich in TDS and the human
inlet tube) for few litres of water until you get crystal clear water at its outlet. body can perfectly balance the TDS in the body to avoid affecting health.

Post installation, it is necessary to drain off 2 complete cycles of water Water taste, odour or smell are few aesthetics parameters which are perceived as
(approximately 15 litres) from purifier tap / spout to ensure good taste of water unacceptable for purified water from a newly installed purifier or freshly replaced
from 3rd cycle onwards. filters. Such cases can be solved by flushing the filters and storage tank with
purified water two or three times, and then using the water for drinking. In case
The purifier is designed to work up to maximum 2000 ppm TDS, 500 ppm total this issue reappears after a few days or weeks, it is recommended to ask for
hardness and 100 ppm total alkalinity and the pH between 6.5 to 8.5. assistance at nominal cost by calling helpline number.

The claimed life in litres is when the purifier is assessed under test conditions
with 750 ppm TDS, 300 ppm total hardness and 80 ppm total alkalinity, less than USE OF REJECT WATER:
0.3 ppm iron and less than 1 NTU turbidity as key parameters in water quality. If
Pureit always works towards minimizing the reject water and thus has designed
any of these parameters change, the performance may get affected and you
models with high recovery of water. In turn, we recommend you to further help
may need to replace the filters at nominal cost earlier than claimed life.
us by using reject water for gardening.

Many a times, water quality parameters with respect to TDS, total hardness, total
alkalinity, iron, turbidity, water line pressure, etc. may vary due to seasonal
change, mixing of water sources due to unavailability of water especially during
summer, etc. This may affect the performance of filters; hence it is recommended
to get the filters periodically checked and cleaned or replaced by authorized
service technician at nominal cost.

TDS is not the only parameter basis which water quality can be defined, there
are many other parameters which can contaminate water and even the
crystal-clear water with low TDS can have toxic chemical substances that pose a
health hazard to the water, hence Pureit RO purifiers purify 100% of the water
through the most advanced technology viz., RO membrane which ensures
removal of harmful & toxic chemical substances to make the water safe for
drinking.

4
KEEP YOURSELF SAFE CLEANING AND MAINTENANCE
Sediment Filter (GKK-1)

Revito Prime Revito Prime Revito Prime

  

  

Rotate the housing in the direction as Take out the Sediment Filter (GKK-1)
shown in the image and remove it from the cap.
completely from the cap.

Clean the Sediment After cleaning the Insert the housing inside the cap &
Filter (GKK-1) under filter, put the filter rotate it in the direction as shown in
jet of water. rub by back in the cap. the image to engage the threads.
hand / tap gently Ensure the housing is tightened till
to clean. its original marking.

5
TECHNICAL SPECIFICATIONS&&
LED INDICATOR GUIDE Pureit Revito Series Purifier
Model Pureit Revito Prime
Dimensions (H×W×D) 488 mm X 375 mm X 265 mm
Weight (Complete Unit) 8.5 kg
Flow Rate Up to 28 litres per hour
Revito Prime
Revito Prime Storage Tank Capacity1 8 litres
7 Stage Purifying Technology Pre-sediment Filter, Pre-RO Carbon Filter, Mesh Filter,
Reverse Osmosis Membrane, Post Carbon Filter,5
Microfiltration Membrane, UV-LED
Membrane Type Thin-film composite spiral wound (WQA Certified)
Low
Pump Type Diaphragm pump, 24 V DC
% Recovery2 Up to 70%
TDS Reduction3 Complies to IS 16240. Even up to 90%
Input Water PH range 6.5 - 8.5, Temperature range 10°C - 40°C
Input Power 37 W
Pressure Rating Min 0.06 MPa, Max 0.2 MPa4
Input Voltage 100 - 240 Va.c., 50/60 Hz (Device can be withstand voltage
fluctuation from 100 to 300 Va.c.)
Material of Construction Food safe, non-toxic, engineering-grade plastics
Length of Power Cord 1.5 metres
Total Dissolved Solids in Input Water Up to 2000 mg/litre
Total Hardness 500 mg/lit (max)
Iron in Input Water 0.3 mg/lit (max)
Turbidity in Input Water 1 NTU (max)
Germkill Kit™ GKK
Material of Construction Food safe, non toxic, engineering-grade plastic

ESF (GKK-1) External Sediment + Pre RO Carbon Filter +


Antiscalant + Mesh Filter - 1 number

GKK (GKK-2) External Sediment + Pre RO Carbon Filter +


Antiscalant + Mesh Filter - 1 number
RO Membrane - 1 number
Post Carbon + Micro-filtration Filter - 1 number
LED Status Description: Mineral Enhancer- 1 number
1 will be active at approximately 113 and 338 hours of pump running time to remind the user to clean or replace the
sediment filter (GKK-1). You can either clean the ESF (GKK-1) or call Pureit helpline to replace it at a nominal cost. Germkill performance standard Meets stringent international criteria for microbiologically
2 will be active at approximately 210 hours of pump running time to remind the user to replace the sediment filter (GKK-1). safe drinking water—e.g, Environmental Protection
Please call Pureit helpline for assistance.
Agency (EPA), USA
3 will be active at approximately 225 hours of pump running time to require the user to replace the sediment filter (GKK-1).
If the filter remains unchanged, then the product will stop purifying water. Please call Pureit helpline for assistance. At this
time, the ESF (GKK-1) should have processed 4000 litres of purified water&.
1 7.5 to 8 litres under running water conditions.
2 & 4 will simultaneously be active at around 435 hours of pump running time to remind the user the replace the GKK
(GKK-2) which contains all the filters in the system including the ESF (GKK-1). Please call Pureit helpline for assistance. 2 Permeate flow rate and recovery are based on standard test conditions and may vary depending on input water quality, TDS,
pressure and life of Filter elements.
2 & 5 will simultaneously be active at around 450 hours of pump running time to require the user to replace the GKK
(GKK-2). If the filter remains unchanged, then the product will stop purifying water. Please call Pureit helpline for 3 Input water quality and TDS content are important determinants of output water quality.
assistance. At this time, the GKK (GKK-2) should have processed 8000 litres of purified water&. 4 If input pressure exceeds 0.2 MPa, please install a company provided ‘pressure reducing valve’ at an additional cost.
The above LED operating logic will be continuously repeated going forward. If the pressure is less than 0.06 MPa then you need to buy ‘pressure enhancing pump’ at an additional cost.
While the ESF (GKK-1) and GKK (GKK-2) filters have a fixed replacement schedule, the user might be required to Device should not be installed in a house where input pressure is greater than 0.4 MPa.
change them in the interim depending on the quality of input water. 5 Post-RO Carbon Filter fitted in the device may need to be changed intermittently at extra cost in case you face smell issues.

& 0.06 MPa && Technical specifications are subject to change or improvement without prior notice.
Environment Temp. and Water Temp. - 25°C

6
FAQS
1. How does Pureit Revito Prime purify water? 8. Can I open and service my purifier?
Pureit Revito Prime has a 7-stage purification process which ensures you to get water that is ‘As Safe As It is not recommended to open and service purifier by an individual. Call our Pureit helpline if you face any
Boiled Water’ and also removes excess Total Dissolved Solids (TDS) to make your water tastier. issue which requires servicing and opening of the purifier.

Stage 1. External Sediment Filter 9. Can I use reject water?


Removes fine and coarse particulate impurities/dirt and improves the life of the Carbon Filter. It is not recommended to use the reject water for any kind of human/pets consumption (drinking or cooking). It
may be used for gardening or cleaning floors.
Stage 2. Pre-RO Carbon Filter
Removes chlorine and organic impurities like harmful pesticides. It also absorbs bad taste and odour 10. What should I do if any part of purifier is broken?
causing organic compounds from water. Please call the Pureit helpline. Our technicians will visit your house and guide you on the repairs required.
There will be a nominal visiting charge and you would need to buy the parts required.
Stage 3. Mesh Filter
Filters water further to ensure removal of finer particulate impurities. 11. What should I do if there is leakage from the purifier?
First switch off the ball valve if you find any leakage from the purifier and turn off the power switch. Check for
Stage 4. Reverse Osmosis Membrane any visual improper fitment and then call our Pureit helpline number and register a service request.
Removes bacteria and viruses causing water borne diseases like Typhoid, Jaundice, Diarrhea etc.
12. How long the stored water in Pureit Revito Prime can be used for drinking?
Stage 5. Post Carbon Filter You can use stored water for 2 days. If it is not used for more than 2 days we advise you to discard that water,
Acts as a polisher and enhances the taste of purified water. refill and then consume.

Stage 6. Microfiltration Membrane


Microfiltration Membrane acts as an additional filtration stage to remove bacteria.

Stage 7. UV-LED
Inactivates upto 99.99% harmful disease causing bacteria and viruses to deliver safe drinking water.

2. What is the storage capacity of Pureit Revito Prime?


Pureit Revito Prime has storage tank capacity of up to 8 litres under running water conditions. The storage tank
is fully automatic and well shielded and as and when you take water out of the tank, the purification process
starts automatically again and refills the storage tank.

3. How much time does it take to purify water in Pureit Revito Prime?
Pureit Revito Prime can purify water up to 28 litres per hour depending on the device you have purchased.
However, the time taken to purify depends on the life of the filters, the input water pressure, TDS and other
impurities present in the water.

4. Does Pureit Revito Prime remove arsenic, fluoride, nitrates and iron?
Like other irons, the RO technology can also remove arsenic, fluoride, nitrates, and iron. However, you are not
recommended to use our device if the input water contains more than 0.1 ppm of arsenic, 8 ppm of fluoride, or
0.3 ppm of iron.

5. How will I get new consumables/membranes replaced?


You need to call the Pureit helpline and order the consumables. The customer care specialist will visit your
place and replace the consumable/Germkill Kit at a nominal cost.

6. What are all the consumables/membranes which are to be replaced?


The sediment filter (GKK-1) needs to be replaced/cleaned after consuming 4000 litres of purified water or within
1 year and GKK (GKK-2) needs to be replaced/cleaned after consuming 8000 litres of purified water or within 2
years (approximately) from the date of installation, whichever occurs first.

7. Can I drink the first purification cycle of water from the purifier?
No, recommendation is to throw the first cycle of water that is filled in the storage tank when the new Pureit
purifier is installed and also whenever the Germkill Kit are replaced.