TITLE: STRENGTH PARAMETERS OF

EARTH LOAD CALCULATION


Determine the maximum earth load (W) on the 18" risers due to landfill at final grade.

Bc= 18 ft
H= 18 in
W= 90 pcf
T= 133.6 ft

Wc= load on Pipe (psf)


Cc= load coefficient, obtained from figure 9-7 of ASCE no.60
W= Unit weight of overlying fill (pcf)
Bc= outer diameter of pipe (ft)
H= Height of fill above the top of the pipe (ft)

Wc= Cc x W x Bc^2

if assumed that the embankment condition over a positive projecting pipe, since the pipe
is located in a wind trench and the top of the pipe is near the surface of compacted soil.

Wc= H x W x Bc

Wc= 18036 lb/ft


the maximum load on the pipe (Wc) = 1503 lb/in

e= 2.178
h= 1603 in
hw= (height of water above the pipe) 1 in
E= (modulus of soil reaction) (psi) 30000 psi
E'= (modulus of elasticity of the pipe material) 3000 psi
DF= (design Factor) 0.4
Rw= (buoyancy factor) 1
B'= (coefficient of elastic support) 1
tmin= 1.059 in
Davg= 214.9 ft
I= 0.099
σc= (max allowable) 800 Psi
DI= (deflection Lag factor) 1.5
Kx= (bedding constant) 0.083
SDR= (Standard Dimension Ratio) 204

qa= DF(2.67*Rw*B'*E'*E')/(SDR-1)^3
qa= (safe allowable buckling load) 2.144 psi

check if the Rw(W/Davg) equals or lesser then qa

Rw*(W/Davg)= 88.7

then 89 > 2.14 NOT OKAY


Factor of Safety= 0.024

Wall Crushing

σc= 709.6 psi


Factor of Safety= 1.127 HENCE OKAY

Ring defelection

Dy= Di*w*Kx/(2*E/(3*SDR-1)^3+0.061*E') 1.023 in

Deflection (%)= 5.681 %


ENGTH PARAMETERS OF THE 18" RISER PIPES

lb/in
HENCE OKAY