AQUA CHILL SYSTEMS INDIA PVT LTD
HOT AND COLD WELL TANK
150 m3 (9
Weight, ( summary )
Horizontal
Horizontal
Vertical
Vertical
wider
Longer
Width of tank - Shorter dimension W
Length of tank -Longer dimension L
Height of tank H
Side wall thk t1
Bottom plate thk t2
Roof plate thk t3
corrosion allowance c
Weir Plate Height WW
Weir Plate Thickness t4
Weight calculation
Roof Plate weight
Roof Stiffener weight 12 Nos.ISMC75 ( 76.2Hx40wx6.9thkwebx9thkflange) L 9000 Roof
Stiffener weight 7 Nos.ISMC75 ( 76.2Hx40wx6.9thkwebx9thkflange) L 4200 Roof
Nozzles
Longer side Plate weight 9000x4000x10thk x 2 nos Shorter Side Plate weight
4200x4000x10thk x 2 nos
Longer Shell Stiffeners weight 6 Nos.ISMC75 ( 76.2Hx40wx6.9thkwebx9thkflange) L 9000
Shorter Shell Stiffeners weight 6 Nos.ISMC75 ( 76.2Hx40wx6.9thkwebx9thkflange) L 4200
Longer Shell Stiffeners weight 12 Nos.ISMC75 ( 76.2Hx40wx6.9thkwebx9thkflange) L 4000
Shorter shell Stiffeners weight 8 Nos.ISMC75 ( 76.2Hx40wx6.9thkwebx9thkflange) L 4000 Shell
Nozzles
Bottom Plate weight
Bottom Stiffener weight 7 Nos.ISMC102 ( 102Hx50.8wx6.1thkwebx7.6thkflange) L 9000
Bottom Stiffener weight 12 Nos.ISMC102 ( 102Hx50.8wx6.1thkwebx7.6thkflange) L 420
Handrail weight
Ladder Wt
Weir Plate weight width 4200 x ht 3800 x 8 thk Vertical Stiffner Weight
160x8thk x 3800 x5 nos.
Horizontal Stiffner Weight 160x8thk x 4200 x5 nos.
Empty weight of tank ( Shop) We1
This is bare minimum plate and stiffners weight
welding fillet weight + manway rungs to be added
= 4200 mm
= 9000 mm
= 4000 mm
= 10 mm
= 12 mm
= 8 mm
= 2 mm
= 3800 mm
= 8 mm
= 2374 Kgs
= 551 Kgs
= 441 Kgs
= 400 Kgs
= 5652 Kgs
= 2638 Kgs
= 481 Kgs
= 224 Kgs
= 427 Kgs
= 285 Kgs
= 400 Kgs
= 3561 Kgs
= 644 Kgs
= 515 Kgs
= 1200
= 200
= 1002 Kgs
= 191 Kgs
= 211 Kgs
= 21395 Kgs