AEC UPS Uninterruptible Power Supply Catalog
AEC UPS Uninterruptible Power Supply Catalog
CRITICAL POWER
WWW.AECUPS.COM
AEC FROM 1968
WE ARE BEHIND THE POWER...
TABLE OF
CONTENTS
AEC Group
History 06
Financials 08
Services 10
Solutions 12
CPSS EN50171 62
ABOUT
AEC
OUR VISION
The AEC group is an innovative multinational
company and at the forefront of the infrastructure
sector critical electrical and renewable energy and
55 800 11
arises the aim is to improve the quality of the Years of experience Employees Offices
life of citizens and workers.
AEC GROUP
OUR HISTORY
Allis Electric Corporation, better known as AEC, was founded
on September 25, 1968, in the capital of Taiwan, Taipei.
The company started the business by producing low voltage
switchboards, motor control centers, integrated high starter panels
and low voltage, AC / DC industrial control equipment and
transmission and distribution equipment. Its constant activity of
expansion led to the development of independent departments
which produce transformers, switching devices and subsequently
various products in the electronics sector of power.
Through investments, joint ventures and the creation of offices
abroad in Europe, the United States and China, AEC continues to
develop alliances strategic business in order to pursue excellence
such as multinational corporate group. With the confidence
provided through over 55 years of solid performance and in-depth
From 1968.... knowledge, AEC will continually work on his core competencies
to be increasingly customer-oriented and to create values for its
shareholders.
Founded in 1968, the AEC group,
Allis Electric Co. Ltd, is a public company
Listed on the Taipei Stock Exchange since
In 2023 the group, headquartered in Taipei, counts
1994.
4 official branches and 11 offices with service centers
Global leader in the field of
highly specialized and available 24/7.
critical electrical infrastructures, digital
Spare parts stocked in over 21 countries.
and telecommunications, the AEC group
has been specializing in the production
of uninterruptible power supplies for the
Products manufactured and marketed by us can
protection of the power supply of
be supported and assisted anywhere in the world, the
industrial installations.
our network of offices allows us to cover whatever
Technology and design come together
time zone and almost all countries in the world.
to create continuity systems cutting-edge,
robust and efficient.
In 1994, the AEC group, now a solid reality with over 30 years of
experience, it is listed on the Taipei stock exchange through an offer
public launch that was hugely successful.
Stock exchange listing and strategic alliances with partners
Europeans have allowed it to continue its steady growth
and to venture into the telecommunications and high-end sector
technology, designing and developing products qualitatively
without equal.
All products manufactured by AEC are guaranteed by certificates
ISO 9001 quality, ensuring customers the utmost seriousness
production and reliability over time.
Our history 7
The AEC group, Allis Electric Co., has been listed on the Taipei Stock Exchange
since 1994. Our company has a capitalization of over 900 million dollars and
a staff of 800 employees located in 4 main commercial and production sites
located in Italy, Taiwan, USA, Japan and South Africa.
FINANCIALS
AEC GROUP
Constancy, attention to detail and attention to the
customer are just some of our pillars.
From 1968 to today ... $295 MILIONS
TURNOVER IN 2023
AEC was originally a supplier of OEM machinery to manufacturers Critical Power: production and sale of UPS &
Italians and Europeans who use their own brand, while today AEC CPSS continuity systems, and lead or lithium
promotes its brand as a leading manufacturer in the industry and battery storage systems.
for some years it has delocalized and diversified its production which Renewable energies: among the first
it is not only Asian, but it is present with several factories in the designers of photovoltaic inverters, AEC
States United and in Italy to meet the needs of different markets is today an important player in the world
locals. of solar, marketing string and storage PV
inverters for residences and industries.
This continuous improvement process, as well as having an Electrical Mobility: to meet the looming
advantage direct and beneficial on sales and after-sales assistance need to transit from fossil fuel to electric
sale, strengthen the reputation of AEC as of more and more a vehicles, we are committed to offering a
serious, dynamic company attentive to technological progress e wide range of charging stations for electric
qualitative, always in total harmony and respect for the environment. vehicles.
200 Mln $
150 Mln $
100 Mln $
50 Mln $
Uninterruptible Power Supply Solar Inverter Photovoltaic Our passion, our core business...
OEM Productions in Europe ON-OFF Grid System | PV Inverter Battery | Storage Systems
Despite all the difficulties + 42% UPS sales The main core business of AEC,
due to the pandemic it has + 27% sales of PV solar inverters the world of UPS is giving great
hit our planet, the AEC group + 31% sales of 12V batteries satisfaction in terms of growth and
managed to conclude one of the The AEC group continues its our group persists in increasing
best years ever, reaching over 184 growth and increases sales of its market share, especially in the
million dollars in global turnover. all 3 of its departments. Italian national market.
Our services
OUR
SERVICES
Our team of dedicated experts is always available to evaluate and analyze the infrastructures on which the customer’s reality
operates. Our company offers a very varied and complete range of services, our specialized technicians are able to support our
customers’ projects in all their aspects, from design, to implementation and maintenance.
Design and engineering consultancy, installation of UPS and PV Inverter devices, maintenance of critical infrastructures, lead-
acid battery changes and diesel generator tests, are just some of the services that AEC carries out daily for various customers
throughout our peninsula.
360 degree advice on any Our call center is available 24 hours Technicians located throughout the
critical infrastructure and facilities for per day also on WhatsApp or via peninsula Italian are available for
renewable energies. Our engineers our Live Chat on the aecups.com website. support after-sales interventions. In
they specialize in the study of Our operators will reply to synergy with our call center, the
feasibility and design of structures any of your doubts and they will be our service of technicians will be able
for data centers and photovoltaic able to direct you to the products to provide quick assistance by telephone
systems from scratch or to be restored. best suited to your needs. or through on-site intervention.
Our services 11
Surveys and UPS installations for Assistance is one of the flagships Maintenance is very important
critical infrastructure. AEC technicians of the AEC group, which offers its of the electronic devices installed, for
are highly qualified for installations of customers a continuous service thanks this AEC makes various available
UPS and battery cabinets of various to which it is always possible to find a maintenance programs and contracts,
brands of UPS manufacturers. technician and solve problems around with the ability to customize
Commissioning and verification of all the clock. AEC always aims to obtain the assistance according to the needs of the
device values and parameters. maximum customer satisfaction. customer and user.
OUR
SOLUTIONS
Ad hoc customized solutions based on the specific requests of the user, meticulous design and feasibility study for all projects
carried out by AEC. We are well aware that there is no longer a standard solution to all situations, and for this reason AEC has
always been dedicated to the development of innovative solutions based on customer feedback.
Our team will follow you step by step in choosing the most advantageous solutions to your situation!
AEC has always focused on While most fossil raw materials With over 53 years of experience
research and development of are being depleted, electricity in the power electronics sector
new technologies and, especially and energy needs are increasing and more than 30 in the renewable
in recent years, has invested in all countries of the world. The energy sector, the AEC group has
heavily in the development of scarcity of materials and the leveraged and put its expertise
modular UPS with innovative rising cost of electricity are more into play to develop and build a
hot-swappable N + 1 technology. than ever global struggles for wide range of charging stations for
New powers also available in which our group is constantly electric vehicles. , available in both
a single 1250kVA UPS solution working on innovative solutions alternating current and super fast
with 10 125kW modules. UPS, with low environmental impact. direct current modes. Our range
uninterruptible power supplies, Our aspiration is to incentivize of EV solutions is able to support
are the main business of AEC, and promote renewable and the most varied needs in terms
which thanks to its significant ecological energies in a significant of power needed, installations in
investments has always managed and incisive way. For this reason private or public environments,
to offer products of the highest we develop ever more efficient such as hospitality or healthcare
quality and reliability. Among the technologies and systems. facilities, shopping and recreation
most advanced technologies in the As a diversified industrial group centers, companies, congress
world of power electronics, AEC with extensive engineering centers, public car parks and large
uses the 3-level IGBT topology capabilities, AEC provides state- supermarkets.
with redundant components, of-the-art products, services and
guaranteeing maximum reliability solutions to meet the insatiable
also through an extended 3-year growing energy needs around the
warranty, which can be extended world.
by means of a maintenance
contract at our service centers.
authorized.
13
Nowadays the use of data centers in the productive world is growing dramatically as they are of fundamental
importance to support the continuous technological development of our planet. If until a few decades ago the
interruption of the operation of a data center would not have caused great inconvenience, today we must always
remain vigilant and ready to intervene in the event of system failure.
For this reason, UPS uninterruptible power supplies are an indispensable element for the correct and continuous
operation of data centers and there are several factors to consider when evaluating the type of UPS to install.
15
CRITICAL POWER
UPS, CPSS & BATTERIES
Critical Power - UPS, CPSS & Batteries
Battery Cabinets 74
1:1
The UPS are available in models with internal batteries or combined with external
battery cabinets for longer runtimes. The 6kVA and 10kVA UPSs include the manual
bypass disconnector to allow correct maintenance without interrupting the output.
The USB card is included and the product range is covered by a 3-year warranty.
The UPS comply with the CEI 0-16 standard.
PRINCIPALS FEATURES
EXCELLENT PERFORMANCE
• Output power factor equal to 1 for a better load capacity • In compliance with the CEI-016 standard, the Charge
at the same power with lower and more convenient reserve function allows the batteries to maintain an
initial investment costs; energy reserve to always guarantee the rearming of the
coil and the restoration of full functionality of the cabin;
• Efficiency AC\AC up to 96%;
• Advanced DSP digital control technology for precise and
speed data processing;
• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • NC \ NO dry contact card for alarms (optional).
configurable from on-site display;
WARRANTY
ASSISTANCE
IST3 1 KVA
Label
2 x Socket Schuko
Fan
Fan
USB\SNMP\Contact card
RS232
Label
Wheels
IST3-L 6-10 KVA
USB\SNMP\Contact card
RS232
Label
Ventilation grid
TECHNICAL SPECIFICATIONS
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
1:1
The UPS are available in models with internal batteries or combined with external
battery rack cabinets for longer autonomy. Our 1kVA, 2kVA and 3kVA models have the
hot-swappable battery pack which facilitates quick replacement. The 6kVA and 10kVA
models have the advantage of occupying only 2U. The USB card is included and the
UPS are covered by a 3 year warranty.
PRINCIPALS FEATURES
EXCELLENT PERFORMANCE
• Output power factor equal to 1 for a better load capacity • Small footprint of only 2U even for 6 and 10kVA models;
at the same power with lower and more convenient
initial investment costs; • Possibility of installation in 19-inch rack or tower;
• Efficiency AC\AC up to 96%; • Advanced DSP digital control technology for precise and
Efficienza
rapid data processing;
100,00%
STANDARD E COMMUNICATIONS
• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • Maintenance bypass rack module (optional);
configurable from on-site display;
• ECO mode configurable from on-site display; • SNMP network card for remote control and monitoring
(optional);
• 16 \ 17 \ 18 \ 19 \ 20 battery configuration via RS232
port (6-10kVA); • NC \ NO dry contact card for alarms (optional).
WARRANTY
ASSISTANCE
IST3-J 1 KVA
1. OUTPUT SOCKET;
2. MAINS INPUT SOCKET;
3. OVER-CURRENT PROTECTOR;
4. EXTERNAL BATTERY PORT;
5. COOLING FAN;
6. EPO CONNECTOR;
7. RS232 COMMUNICATION PORT;
8. INTELLIGENT SLOT;
1. OUTPUT SOCKET;
2. MAINS INPUT SOCKET;
3. OVER-CURRENT PROTECTOR;
4. EXTERNAL BATTERY PORT;
5. COOLING FAN;
6. EPO CONNECTOR;
7. RS232 COMMUNICATION PORT;
8. INTELLIGENT SLOT;
Communication Port
EPO
Cover
TECHNICAL SPECIFICATIONS
OTHER SPECIFICATIONS
RS232+EPO+USB (slot)
COMMUNICATIONS
(SNMP, RS485+ optional dry contact card)
OUTPUT SOCKET 8×IEC320 C13 8×IEC320 C13 + 1×IEC320 C19 Screw wire terminal
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
1:1
The lithium UPS units are available in models with internal batteries or combined with
external battery cabinets for longer runtimes. The IST8 UPS is capable of withstanding
temperatures up to 50 ° without risking damage to the batteries.
5-years battery warranty.
PRINCIPAL FEATURES
LITHIUM ION BATTERIES
• Output power factor equal to 1 for a better load capacity • In addition to being much lighter and less bulky,
at the same power with lower and more convenient lithium-ion batteries are also much more versatile
initial investment costs; and advantageous thanks to their ability to operate in
extremely cold temperatures.
• Integrated lithium-ion batteries, weight reduction up to Maximum operation at -20 ° C and up to + 50 °
40% compared to traditional lead-acid VRLA batteries, C, without any risk of damage o downgrading of
maximum discharge capacity up to 80% and an expected performance;
life of 15 years and over 1500 charging cycles;
• Possibility of installation in 19-inch rack or tower;
• Wide input tolerance, compatible with diesel generators; • Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.
• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • Maintenance bypass rack module (optional);
configurable from on-site display;
• ECO mode configurable from on-site display; • SNMP network card for remote control and monitoring
(optional);
• RS232 and USB communication ports equipped with user • NC \ NO dry contact card for alarms (optional).
manual, cable and CD for software;
WARRANTY
ASSISTANCE
BUILT-IN LITHIUM-ION BATTERIES
EXCELLENT PERFORMANCE
• Higher energy density: Li-ion batteries lithium have a • Life cycles: Li-ion batteries have a cycle longer life
higher energy density than to lead-acid batteries, which than lead-acid batteries, i.e can be downloaded and
means they can store more energy in a smaller space. reloaded for a greater number of times before losing
their capacity.
• Higher efficiency: Lithium-ion batteries have higher • Self-discharge: Li-ion batteries have a self-discharge
efficiency than lead-acid batteries, which means they lower than lead-acid batteries, which meaning they lose
can provide more energy for each unit of weight. less energy when not in use.
1. OUTPUT SOCKET;
2. MAINS INPUT SOCKET;
3. OVER-CURRENT PROTECTOR;
4. EXTERNAL BATTERY PORT;
5. COOLING FAN;
6. EPO CONNECTOR;
7. RS232 COMMUNICATION PORT;
8. INTELLIGENT SLOT;
Lithium ion UPS rack 19” 27
TECHNICAL SPECIFICATIONS
MODELS IST8-1-LI IST8-2-LI IST8-3-LI
INPUT
VOLTAGE (VAC) 120-295
FREQUENCY (HZ) 50/60± 10% (50/60Hz)
POWER FACTOR ≥0.99
THDI <5%
OUTPUT
POWER (WATT) 1000 2000 3000
MAX. AC/AC EFFICIENCY 92.7% 93.5% 96%
POWER FACTOR 1
VOLTAGE (VAC) 208/220/230/240±1%
FREQUENCY (HZ) 50/60±0.1
THD <3%
SWITCHING TIME (MS) 0
ECO MODE Yes
OVERLOAD 101%~115% for 1 min, 116%~133% for 1 s, < 134% for 200ms
LITHIUM BATTERIES
VOLTAGE (VDC) 24 48 72
BACKUP TIME (MIN) 12 12 12
MAX. CHARGING CURRENT (A) 4
OTHER SPECIFICATION
COMMUNICATIONS USB and SNMP (slot) (RS232+ Optional dry contact card)
OUTPUT SOCKETS (1)IEC C19 + (6)IEC C13
DISPLAY LCD
PROTECTIONS Low batteries, Overload, Short-circuit, Over-temperature, ecc.
NOISE (DB) < 55
TEMPERATURE 0°C~50°C
HUMIDITY 0 ~ 95%
DIMENSIONS (L×W×H) (MM) 438×420×87 438×570×87 438×570×87
WEIGHT (KG) 8.9 13.6 19.6
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
1:11:1 3
All-In-One can be configured in 1\1 or 3\1 or 3\3 input\output mode directly from
the display. The All-In-One Cabinet is on wheels and it includes an online UPS upto
20kW, a distribution module with manual maintenance bypass and up to 8 slots for
Hot-swappable Lithium battery modules 50Ah.
UPS 10-20kW
1:1 or 3:1 or 3:3
• Innovative three-level IGBT technology integrated in the • Advanced BMC communication to allow mixing old and
inverter section; new Lithium-Ion Modules.
RS485 TCP/IP
NetEco
CAN CAN
• Access to the menu via different password levels • Alarms from dry contact card 5 or 12 Input\Output
available alarms (optional);
(User, Technician and Manufacturer);
• SNMP Network Card for remote monitoring and
• Large memory up to 10,000 events downloadable via the USB
controling (optional).
port integrated in the UPS;
Physical Appereances
TECHNICAL SPECIFICATIONS
MODELS ALL-IN-ONE
UPS INPUT
CONFIGURATION 1:1 3:1 3:3 INPUT - OUTPUT
VOLTAGE (VAC) 80-280 (L-N) or 138-485 (L-L)
FREQUENCY (HZ) 40-70
POWER FACTOR ≥0.99
THDI <3%
UPS OUTPUT
POWER (kW) 10 15 20
MAX. AC/AC EFFICIENCY 97,00%
POWER FACTOR 1
VOLTAGE (VAC) 220/230/240±1% (L-N) or 380/400/415±1% (L-L) (configurable)
FREQUENCY (HZ) 50/60±0.1
THD THD <2% (linear loads), THD < 4% (non-linear loads)
SWITCHING TIME (MS) 0
ECO MODE Yes
115%~130% Overload for 15mins, 130%~150% Overload for 1min,
OVERLOAD
more than 150% Overload for 200ms
LITHIUM-ION BATTERY MODULES
LITHIUM-ION MODULES L6-50-4C-240-X
BATTERY TYPE
HOT-SWAPPABLE MODULES
BATTERY NUMBER Maximum 8 LITHIUM MODULES
BATTERY RATED VOLTAGE (V) 57.6
BATTERY CAPACITY (AH) 50
MAX. ENERGY (KWH) 2.8
DC/DC RATED OUTPUT POWER (KW) 10
RATED OUTPUT VOLTAGE (V) 240/±240/480
SOC ACCURACY ≥95%
HUMIDITY 0 ~ 95%
UPS 438×500×130(3U)
Distribution Box 438×500×130(3U)
DIMENSIONS (L X W X H)
Lithium Battery Module 223×665×153
FULL UPS SYSTEM 600×860×1200
UPS 20
Distribution Box 8
WEIGHT (KG)
Lithium Battery Module 38±2
FULL UPS SYSTEM 120 *Without built-in UPS and batteries.
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
UPS SERIES IST 9
PRINCIPAL FEATURES
EFFICIENCY AND FLEXIBILITY
• Output power factor equal to 1 for a better load capacity • Extremely flexible input adaptable to all needs, tolerance
at the same power with lower and more convenient range -60% ~ + 25%;
initial investment costs;
+25%
- 60%
• Innovative three-level IGBT technology integrated in the
inverter section;
ECO Mode
display, for an improved and user-friendly user
experience;
• Battery configurations minimum 24 up to 40 per series
(± 144 ~ ± 240Vdc) via display;
• UPS input and output configurable from display in
single-phase and \ or three-phase (1: 1,3: 1,3: 3);
• Possibility of parallel installation (redundant or power)
up to 4 units;
• ECO, Normal or Parallel N + 1 mode configurable from
on-site display;
• Display available in 7 languages.
input-output-battery configuration directly from 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
display;
ECO Efficiency
AC/AC Efficiency
• Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.
STANDARD AND COMMUNICATIONS Cable terminal IN-OUT-BYP Parallel (only for PRL models)
RS485
TECHNICAL SPECIFICATIONS
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
3:1 3:3
PRINCIPALS FEATURES
EFFICIENCY E FLEXIBILITY
• Output power factor equal to 1; • Advanced control with double redundant DSP;
100%
• ECO mode with efficiency up to 99%, configurable from
the display;
98%
+25%
ECO Efficiency
AC/AC Efficiency
- 60%
• Innovative three-level IGBT technology integrated in the
inverter section;
• 30kVA and 40kVA versions with configurable output • Shared batteries for parallel systems, a single battery
from display in single-phase or three-phase (3: 1,3: 3); pack for two N + 1 UPSs;
• Integrated external battery connector; • NC \ NO dry contact card for further 12 alarms
(optional).
UPS Three Phase - Single Phase 41
TECHNICAL SPECIFICATIONS
IST7-10-32X9 IST7-20-36X9 IST7-30-72X9 IST7-40-72X9
MODELS
IST7-10 IST7-20 IST7-30 IST7-40
INPUT
VOLTAGE (VAC) 80-280 (L-N) / 138-485 (L-L)
FREQUENCY (HZ) 40~70
VOLTAGE BYPASS (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3:3 / 3:1 / 1 : 1 3:3 / 3:1
OUTPUT
POWER (kW) 10 20 30 40
POWER FACTOR 1
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD THD<1% (linear loads), THD <3% (non- linear loads)
WAVEFORM Sinusoidal pure, THD<1% linear
EFFICIENCY 97%
110% Overload for 60mins; 130% Overload for 10mins;
OVERLOAD
155% Overload for 1min; >155% Overload for 200ms;
BATTERIES
BATTERY VOLTAGE (VCC) ±96~±240 configurable ±144~±240 configurable ±144~±240 configurable ±144~±240 configurable
BATTERIES CONFIGURATION STANDARD 32*9AH/12V 36*9AH/12V 72*9AH/12V 72*9AH/12V
MAX. CHARGING CURRENT (A) 1-10 (configurable) 1-20 (configurable)
OTHER SPECIFICATIONS
COMMUNICATIONS RS485, MODBUS, Free contact card (RS232 e SNMP optional)
HUMIDITY 0~95%
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
3:1 3:3
IST7 UPSs are available in three sizes, fixed power 60kVA, from 80 to 120kVA and
from 160kVA to 200kVA. Thanks to the inverter’s 3 IGBT levels, the UPS guarantee
efficiency up to 97% and a unitary output power factor. They are directly configurable
from the display, with ample flexibility in the number of batteries and high overload
capacity. The innovative self-cleaning function reduces the risk of dust accumulation
on the boards. The system includes the free contact card for alarms.
PRINCIPAL FEATURES
EFFICIENT AND EXPANDABLE
• Output power factor equal to 1; • Innovative three-level IGBT technology integrated in the
inverter section;
• Maximum AC \ AC efficiency up to 97%;
100%
• Expandable in power directly on site and from the
display;
98%
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
ECO Efficiency
AC/AC Efficiency
• Battery Configurations:
from 28 to 48 monoblocks (±168~±288Vcc);
1
• ECO mode with efficiency up to 99%, configurable from
2
the display;
1
2
• Possibility of parallel installation (redundant or power)
3 up to 1.6MW;
1 Power unit capacity 60kW | 80-120kW | 160-200kW • Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.
2 Bypass and control unit including RS485, Modbus and
programmable dry contact
30% load
98%
95%
efficiency
95%
60% load
93%
96.5%
efficiency
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Intelligent Sleep Mode
W-ECO Efficiency
ECO Efficiency
AC/AC Efficiency
OPERATING MODES
Static Bypass Static Bypass
Battery Battery
Battery Battery
FREQUENCY CONVERTER
50HZ 60HZ
• 50Hz-60Hz or 60Hz-50Hz converter mode;
60HZ 50HZ
• Possibility of disabling the static bypass and the DC
power supply of the inverter. Frequency Converter Mode
• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;
• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);
• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
EXCELLENT PERFORMANCE
• Efficiency higher than 95% even at low loads; • Advanced 3-stage battery charging and maintenance
system;
• Maximum output tolerance, ability to operate with 100%
unbalanced loads;
MORE OPTIONS
• Flexible Network Management: SNMP
• Expanded dry contact kit (4 in 4 out)
• BMS kit for lithium battery communication
• Intelligent Battery Monitoring System
• Battery tripping kit
• N+X in parallel
• Input and output isolation transformer
• SPD: C Grade
• Battery Charge Temperature Compensation
ECONOMIC SAVING
Let’s take an example on a 120kVA AEC UPS working at full load H24 with average efficiency of 96% and a unit output power
factor, comparing it with a typical UPS with standard efficiency 93% and output power factor = 0.9:
• Daily savings:
(120kVA*1*96% - 120kVA*0.9*93%)*24 hours= 354.24 kWh;
TECHNICAL SPECIFICATIONS
MODELS IST7-60 IST7-80 IST7-100 IST7-120 IST7-160 IST7--200
INPUT
VOLTAGE (VAC) 380/400/415 (138~485 L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) +20% (-10/-15/-30 selectable) /+15% (10/20/25 selectable)
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3+N+PE
OUTPUT
POWER (kW) 60 80 100 120 160 200
POWER FACTOR 1
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD 3+N+PE
VOLTAGE STABILIZATION THDv<1% at linear load, THDv<3% at non-linear load
WAVEFORM Pure sine wave
EFFICIENCY 97%
≤130%: long run;
OVERLOAD
130%< load ≤150%: 5min; 150%< load ≤200%: 1s; 200%< load≤300%: 100ms; >300%: immediately.
BATTERIES
BATTERIES VOLTAGE (VDC) ±168 ~±288 adjustable
STANDARD BATTERY CONFIGURATION External
MAX. CHARGING CURRENT (A) 30 60
OTHER SPECIFICATIONS
COMMUNICATIONS RS485, MODBUS, Free Contact Card ( SNMP optional)
DISPLAY Touch screen+LED
ALARMS Low batteries, Anormal input, Overload, Block/Fault ecc.
PROTECTION Low batteries, Overload, Short-circuit, Over-temperature ecc.
NOISE (DB) <65
TEMPERATURE (°C) 0~40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 400×960×1200 600×1000×1600
WEIGHT (KG) 145 161 171 312 320
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
PRINCIPAL FEATURES
EFFICIENT AND RELIABLE
• Output power factor = 0.9;
• Advanced control with double redundant DSP;
• Maximum AC \ AC efficiency up to 94%;
DSP DSP
100%
93%
• Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
improve their efficiency.
ECO Efficiency
AC/AC Efficiency
• The output isolation transformer provides high reliability Automatic fan control
to adapt different harsh industrial environments and
protects the critial loads.
IST7-T
500-600KVA
- 25%
• Self-load test function without load enables onsite
commission (optional);
• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;
• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);
• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
TECHNICAL SPECIFICATIONS
MODELS IST7T-80 IST7T-100 IST7T-120 IST7T-160
INPUT
VOLTAGE (VAC) 380/400/415
TENSION TOLERANCES (VAC) 380/400/415±25%
FREQUENCY INPUT (HZ) 40-70
BYPASS TENSION (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) 348 (360 setting)
CHARGING CURRENT (A) 10~40A setting
OUTPUT
POWER (kW) 80 100 120 160
POWER FACTOR 0.9 (1.0 optional)
PHASES 3+N+PE
WAVEFORM Sinusoidal
TENSION (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2%, allow 100% unbalance
THD THD≤2% (linear load)
MAX. SYSTEM EFFICIENCY 94%
PARALLEL up to 8 units
OVERLOAD 125% load for 10mins, 150% load for 1 min
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Dry Contact Card (SNMP optional)
NOISE (DB) < 65
DIMENSIONS (L×W×H) (MM) 500x800x1600 700×800×1800
WEIGHT (KG) 520 600 650 825
CERTIFICATIONS
MARKING CE
STANDARDS IEC EN 62040-1, IEC EN 62040-2, IEC EN 62040-3
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
UPS Transformer based 53
TECHNICAL SPECIFICATIONS
MODELS IST7T-200 IST7T-250 IST7T-300 IST7T-400 IST7T-500 IST7T-600
INPUT
VOLTAGE (VAC) 380/400/415
VOLTAGE TOLERANCES (VAC) 380/400/415±25%
FREQUENCY INPUT (HZ) 40-70
BYPASS VOLTAGE (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) 384 (348/360/372 setting)
CHARGING CURRENT (A) 10-100A setting
OUTPUT
POWER (kW) 200 250 300 400 500 600
POWER FACTOR 0.9 (1.0 optional)
PHASES 3+N+PE
WAVEFORM Sinusoidal
VOLTAGE (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2%, allow 100% unbalance
THD ≤1% (linear loads at full load), ≤4% (non-linear loads at full load)
MAX. SYSTEM EFFICIENCY 94%
PARALLEL up to 8 units
OVERLOAD 125% load for 10mins, 150% load for 1 min
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Free contact card (SNMP optional)
NOISE (DB) <70
DIMENSIONS (L×W×H) (MM) 1400x1000x1850 1600×1000×1850 3000×1000×1850
WEIGHT (KG) 1280 1568 1830 2050 4500
CERTIFICATIONS
MARKING CE
STANDARDS IEC EN 62040-1, IEC EN 62040-2, IEC EN 62040-3
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
3:3
Their modularity allows future expansion in power up to 4.8MW. They are available in
four sizes, up to 120kVA | 200kVA - 300kVA | 600kVA- 800kVA | 1000kVA-1200kVA |
with an efficiency of up to 97% and maximum safety. IST6 is designed for medium and
large data centers. UPS configurable directly from the display, with great flexibility and
high overload capacity. The self-cleaning function reduces the risk of dust accumulation
on the cards. The system includes the free contact card for alarms.
UPS MODULAR
UPS Modular 55
PRINCIPAL FEATURES
MODULAR TECHNOLOGY HOT-SWAPPABLE
• Output power factor equal to 1;
98%
95%
93%
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
On-ECO Efficiency
ECO Efficiency
AC/AC Efficiency
MAXIMUM SCALABILITY
• Innovative modular N + 1 technology in all components
of the UPS system;
• Expandable and hot potential directly on site and from • Battery configurations:
the display; from 15 to 20 monoblocks (± 180 ~ ± 240Vdc);
• Possibility of installation in a single structure up to • ECO mode with efficiency up to 99%, configurable from
1200kW with 12 modules of 100kW; the display;
• Possibility of parallel installation (redundant or power) • Advanced control with double redundant DSP;
up to 5MW;
DSP DSP
EXCELLENT PERFORMANCE
• Advanced 3-stage battery charging and maintenance
• Efficiency higher than 95% even at low loads;
system;
+25%
• Redundant and hot extractable power modules (rectifier
and inverter);
- 60%
OPERATING MODES
Static Bypass Static Bypass
Batteries Batteries
Online Double Conversion ECO Mode
Static Bypass Static Bypass
Rectifier Inverter
Rectifier Inverter
Load
Batteries Batteries
• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;
• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);
• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
UPS Modular 59
TECHNICAL SPECIFICATIONS
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
TECHNICAL SPECIFICATIONS
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
61
Nowadays the use of data centers in the productive world is growing dramatically as they are of fundamental
importance to support the continuous technological development of our planet. If until a few decades ago the
interruption of the operation of a data center would not have caused great inconvenience, today we must always
remain vigilant and ready to intervene in the event of system failure.
For this reason, UPS uninterruptible power supplies are an indispensable element for the correct and continuous
operation of data centers and there are several factors to consider when evaluating the type of UPS to install.
LITHIUM SYSTEM L6
By following the nuclear-grade safety design concept and leveraging its over 30
years of professional experience in the power field, Allis Electric deeply applied power
electronics to the lithium-ion battery technology and released lithium-ion battery
solution with high safety and reliability - AEC L6 Smart Backup Lithium-ion Battery
System Solution.
LITHIUM SYSTEM
63
PRODUCT STRUCTURE
SBMU
40Ah/50Ah lithium-ion battery system cabinet 100Ah lithium-ion battery system cabinet
SYSTEM ARCHITECTURE
RS485 TCP/IP
NetEco
Layer III
UPS
MBMU
unit
CAN CAN
SBMU SBMU
TECHNICAL PARAMETERS
TYPE LFP
CURRENT-UNBALANCE ≤5%
The EN 50171 standard provides for the obligation to install CPSS in crowded areas and in
public places such as hospitals, schools, museums, cinemas, etc. to provide lighting in the
event of a blackout.
Central Power Supply Systems (CPSS) and Uninterruptible Power Supply Systems
(UPS) have many similarities. As already explained, both products provide electricity
in the event of a blackout or network failure, but it is essential to know that
these two systems are used in different contexts and for this reason they are not
interchangeable.
Although CPSS and UPS have the same components, the former are designed
according to regulatory standards that guarantee maximum product safety to be
applied to safety systems and must comply with all the requirements of the EN
50171 standard.
In fact, the CPSS are used in the event of a power failure during an emergency and
danger situation, such as a fire or an earthquake and, especially on these occasions,
it is essential to have a lighting system that allows people to immediately identify
the ways of exodus, especially in public places subject to crowding and in the
workplace.
CPSS EN 50171
69
EN 50171 COMPLIANT
The EN 50171 standard applies to systems permanently connected to AC power supply voltages not exceeding 1000 V
and which use batteries as an alternative energy source. The structure of the CPSS must also comply with the CEI EN
62040 standard.
The EN 50171 standard lists the technical characteristics that the CPSS must possess in order to be compliant.
FEATURES:
• Batteries:
The batteries used in the CPSS must have an expected life of at least 10-12 years;
• Overload:
The inverters used in the CPSS must be able to handle a constant overload of 120%;
• Charging Time:
The chargers used must recharge the batteries within 12 hours, starting from a low battery condition;
• Casing Resistence:
The casing of the CPSS must have excellent mechanical strength, capable of resisting heat and fire.
DETAILS:
• Constant overload of 120%;
• Batteries 10-12 years expected life;
• Charging time of less than 12 hours;
• Structure compliant with CEI EN 62040.
CPSS EN 50171
CPSS EN-50171 71
TECHNICAL SPECIFICATIONS
INPUT
VOLTAGE (VAC) 80-280 (L-N) / 138-485 (L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3:3 / 3:1 / 1 : 1
OUTPUT
POWER (kW) 8 16 24 32
POWER FACTOR 0.8
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD THD<1% (linear loads), THD <3% (non-linear loads)
WAVEFORM Sinusoidal pure, THD<1% linear
EFFICIENCY 96%
OVERLOAD Constant up to 120%
BATTERIES
BATTERIES VOLTAGE (VDC) ±96~±240 configurable ±144~±240 configurable ±144~±240 configurable ±144~±240 configurable
MAX. CHARGING CURRENT (A) 1-10 / 1-20 (configurable)
BATTERY LIFE 10 - 12 years
OTHER SPECIFICATIONS
CHARGING TIME < 12 hours
COMPLIANCE Structure in compliance with CEI EN 62040
NOISE (DB) < 65
TEMPERATURE (°C) 0 ~ 40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 250×755x880 300x785x1250
WEIGHT (KG) 143 240
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3), EN50171
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
DETAILS:
• Constant overload of 120%;
• Batteries 10-12 years expected life;
• Charging time of less than 12 hours;
• Structure compliant with CEI EN 62040.
CPSS EN 50171
CPSS EN-50171 73
TECHNICAL SPECIFICATIONS
INPUT
VOLTAGE (VAC) 380/400/415 (138~485 L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3-4W+PE
OUTPUT
POWER (kW) 48 64 80 96 128 160
POWER FACTOR 0.8
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD 3-4W+PE
WAVEFORM Pure Sinusoidal , THD<1% linear
EFFICIENCY 96%
OVERLOAD Constant at 120%
BATTERIES
BATTERIES VOLTAGE (VDC) ±168 ~±288 adjustable
STANDARD BATTERY
External
CONFIGURATION
MAX. CHARGING CURRENT (A) 1-30 1-40
BATTERY LIFE 10 - 12 years
OTHER SPECIFICATIONS
CHARGING TIME < 12 hours
COMPLIANCE Structure in compliance with CEI EN 62040
NOISE (DB) <65
TEMPERATURE (°C) 0~40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 450x840x1400 600x900x1600
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3), EN50171
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
AEC is able to offer its customers a tested and solid cabinet housing system for accumulators designed to
ensure continuity of power supply for UPS of any size.
BB2
BB3
BBJ
BBJ2
GENERAL CHARACTERISTICS
DIMENSIONS : 255 x 755 x 900mm
BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 16 up to 80 battery 12V 9Ah
BATTERY CABINET
Battery Cabinet 77
Terminal cover
Optional 2 Breaker
Terminal Block
Ground
Wheels
BATTERY CABINET
MODELS BB4
TECHNICAL SPECIFICATIONS
DIMENSIONS 255 x 755 x 900 mm
WEIGHT (EMPTY) 40 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 80 x 12V 9Ah
IP PROTECTION IP 20
DC FUSES 32A - 63A
CABLE ENTRANCE BACK/REAR
COLOUR RAL9005
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB5
GENERAL CHARACTERISTICS
DIMENSIONS : 460 x 800 x 1400mm
BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 82 up to 128 battery 12V 9Ah
From 16 up to 38 battery 12V 24-26Ah
From 16 up to 38 battery 12V 40Ah
BATTERY CABINET
Battery Cabinet 79
BATTERY CABINET
MODELS BB5
TECHNICAL SPECIFICATIONS
DIMENSIONS 460 x 800 x 1400 mm
WEIGHT (EMPTY) 110 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 38 x 12V 40Ah or 120 x 12V 9Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A
CABLE ENTRANCE RIGHT SIDE TOP AND BOTTOM
COLOUR RAL9005
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB6
GENERAL CHARACTERISTICS
DIMENSIONS : 800 x 800 x 1400mm
BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 20 up to 40 battery 12V 60Ah
BATTERY CABINET
Battery Cabinet 81
BATTERY CABINET
MODELS BB6
TECHNICAL SPECIFICATIONS
DIMENSIONS 800 x 800 x 1400 mm
WEIGHT (EMPTY) 140 Kg
N° OF SHELVES 3
MAX N° OF BATTERY 36 x 12V 60Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A - 160A
CABLE ENTRANCE LEFT SIDE TOP AND BOTTOM
COLOUR RAL9005
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB7
GENERAL CHARACTERISTICS
DIMENSIONS : 800 x 800 x 1900mm
BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 20 up to 36 battery 12V 80Ah
From 20 up to 36 battery 12V 100Ah
BATTERY CABINET
MODELS BB7
TECHNICAL SPECIFICATIONS
DIMENSIONS 800 x 800 x 1900 mm
WEIGHT (EMPTY) 160 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 36 x 12V 100Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A - 160A - 250A - 400A
CABLE ENTRANCE LEFT SIDE TOP AND BOTTOM
COLOUR RAL9005
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB8
GENERAL CHARACTERISTICS
DIMENSIONS : 1400 x 800 x 1900mm
BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 40 up to 64 battery 12V 80Ah
From 40 up to 64 battery 12V 100Ah
BATTERY CABINET
MODELS BB8
TECHNICAL SPECIFICATIONS
DIMENSIONS 1400 x 800 x 1900 mm
WEIGHT (EMPTY) 250 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 64 x 12V 100Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A - 160A - 250A - 400A
CABLE ENTRANCE LEFT SIDE TOP AND BOTTOM
COLOUR RAL9005
ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
ACCESSORIES FOR UPS E CPSS
SNMP CARD
Through the SNMP card, AEC is also able to carry out H24
checks on each UPS, as part of ordinary and / or preventive
maintenance contracts.
The relay or dry contact card provides a series of potential-free normally open or normally closed contacts to signal the
following UPS functions:
USB CARD
The USB card allows you to connect the UPS to all latest generation
computers via a USB port on the PC. This card is essential if the UPS
does not have the RS232 port and is compatible with all our UPS
models.
87
OZ Power lead-acid AGM batteries can last up to 10-15 years, but can
affect several external factors on battery life such as:
- Incorrect use of the battery;
- Inadequate maintenance carried out by a non-specialized technician;
- Exposure to extreme temperatures, both too high and too low;
- Incorrect recharging of the battery using an unsuitable charger.
OZ Power AGM batteries are always sold fully charged and, once
discharged, it is advisable to fully recharge them to make the most of
their potential and to avoid deteriorating them, thus reducing their
capacity and therefore also their duration. Furthermore, it is strongly
recommended to carry out a full recharge to 100% even in case of
prolonged non-use of the battery and to be checked by a specialized
technician for complete efficiency.
89
BATTERY MODELS
12V OZ POWER:
MAIN CHARACTERISTICS
12V 9Ah
• Totally hermetic without emission of gas in use;
• No liquid to add during the entire life of the batteries;
• No risk of acid loss as the electrolyte (diluted sulfuric acid) is
absorbed in an AGM opaque glass-like support;
• The plates are very robust and are welded with special alloys to
12V 24Ah ensure high mechanical resistance;
• The casing is made of ABS (Acrylonitrile Butadiene Styrene);
• The batteries comply with the international standards JIS, UL, VDE,
IATA;
• The batteries are designed for high fast discharge currents;
• The expected life of AEC batteries is 10-12 years, according to the
12V 40Ah EUROBAT guide;
• Enclosures are constructed to UL-94 HB or UL94-V0 fire resistant.
12V 80Ah
12V 100Ah
OZ POWER | 12V 9AH
AGM SEALED LEAD BATTERY
TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 9Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 2.40Kg(5.29Lbs)
INTERNAL RESISTANCE <18mΩ
TERMINAL TYPE F2
MAX DISCHARGE CURRENT 130A
DESIGN LIFE 8-10 Years
MAX CHARGE CURRENT 2.7A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15.0V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 151±1 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 65±1 mm
Storage:-15°C~40°C
HEIGHT 94±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 100±1 mm
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 24Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 7.0Kg
INTERNAL RESISTANCE <12mΩ
TERMINAL TYPE IT (F12)
MAX DISCHARGE CURRENT 375A (5s)
DESIGN LIFE 8-10 Years
MAX CHARGE CURRENT 7.8A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 166±2 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 175±2 mm
Storage:-15°C~40°C
HEIGHT 125±2 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 125±2 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 40Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 12.40Kg
INTERNAL RESISTANCE <10mΩ
TERMINAL TYPE IT (M)
MAX DISCHARGE CURRENT 380A (5s)
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 12A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 197±3 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 166±1 mm
Storage:-15°C~40°C
HEIGHT 170±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 170±1 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 60Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 16.50Kg
INTERNAL RESISTANCE 8mΩ
TERMINAL TYPE IT (M6)
MAX DISCHARGE CURRENT 500A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 15A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 230±1 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 138±1 mm
Storage:-15°C~40°C
HEIGHT 211±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 216±1 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 80Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 20.50Kg
INTERNAL RESISTANCE 6.6mΩ
TERMINAL TYPE IT (M6)
MAX DISCHARGE CURRENT 700A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 22.5A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 259±2 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 168±1 mm
Storage:-15°C~40°C
HEIGHT 208±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 212±1 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT
TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 100Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 28.5Kg
INTERNAL RESISTANCE 5mΩ
TERMINAL TYPE IT (M8)
MAX DISCHARGE CURRENT 1000A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 33A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 330±3 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 173±2 mm
Storage:-15°C~40°C
HEIGHT 216±3 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 222±3 mm
The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.
TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE
TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT