0% found this document useful (0 votes)
24 views104 pages

AEC UPS Uninterruptible Power Supply Catalog

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views104 pages

AEC UPS Uninterruptible Power Supply Catalog

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 104

AEC UPS ITALY

CRITICAL POWER

WWW.AECUPS.COM
AEC FROM 1968
WE ARE BEHIND THE POWER...
TABLE OF
CONTENTS

AEC Group

History 06

Financials 08

Services 10

Solutions 12

Critical Power - Critical Infrastructure 14

UPS | Uninterruptible Power Supply 14

Lithium Cabinets and Modules 56

CPSS EN50171 62

Battery cabinets and accessories 70

Batteries VRLA 12V 84

Locations and contacts 98


AEC Group

ABOUT
AEC

OUR VISION
The AEC group is an innovative multinational
company and at the forefront of the infrastructure
sector critical electrical and renewable energy and
55 800 11
arises the aim is to improve the quality of the Years of experience Employees Offices
life of citizens and workers.

AEC Italy, is part of the AEC group, Allis Electric Co.


Ltd, headquartered in Taipei, Taiwan.
OUR MISSION The Italian branch of AEC represents a model of
Italian excellence within a global company.
AEC constantly strives to provide solutions AEC presents itself with a wide, structured offer to
and increasingly advanced technological products e meet the growing demands of the market of energy.
qualitatively above the market average. Thanks to a staff of nearly 800 employees, of which
An excellent balance to satisfy all of his 130 electronic engineers dedicated to the design and
customers, pursuing harmony, ethics and morals between implementation of new technologies, our company
employees, customers and companies. is able to guarantee maximum quality and speed in
all our services and products, available in over 80
countries through the well-structured network of AEC
offices.
AEC Group 5

TECHNOLOGY AND DESIGN SINCE 50 YEARS


In the AEC world, technology and design come together to create continuity systems that are increasingly avant-garde
and in line with the elegant Italian style. Our company is one of the most respected manufacturers in the world of
uninterruptible power supplies, batteries, PV inverters and EVs Charging stations: double conversion UPS, modular
uninterruptible power supplies, solar storage inverters and direct current charging stations for electric vehicles are just
some of the types of products designed, built and sold by AEC.

RESEARCH AND DEVELOPMENT


Our energies are used to maintain a constant improvement in the quality of ours
products. For this reason, AEC has always systematically set aside and reinvested 6%
of its annual revenue to devote to research and development to improve product quality e
develop new ones.

QUALITY AND EFFICIENCY


AEC is committed to obtaining the most important standard certifications ISO 9001, ISO14001, ISO45001,
proof of the continuous commitment to business improvement in terms of safety and health e
always with the utmost respect for our planet.

With the AEC UPS brand, Allis


Electric Co. is now recognized as
one of the world leaders in the
main markets for uninterruptible
power supplies, renewable energy
and storage systems with lead and
lithium-ion technologies.

AEC produces all its products in full compliance


of the environment, paying particular attention to
follow guidelines that lead us to create groups
of cutting-edge continuity, always in step with
the times and above all in line with our principles:
Harmony, Innovation, Responsibility.
In fact, AEC’s mission has always been to find and
offer green solutions respecting the environment
by putting the customer and theirs are always at the
center of attention specific needs.
Our history

AEC GROUP
OUR HISTORY
Allis Electric Corporation, better known as AEC, was founded
on September 25, 1968, in the capital of Taiwan, Taipei.
The company started the business by producing low voltage
switchboards, motor control centers, integrated high starter panels
and low voltage, AC / DC industrial control equipment and
transmission and distribution equipment. Its constant activity of
expansion led to the development of independent departments
which produce transformers, switching devices and subsequently
various products in the electronics sector of power.
Through investments, joint ventures and the creation of offices
abroad in Europe, the United States and China, AEC continues to
develop alliances strategic business in order to pursue excellence
such as multinational corporate group. With the confidence
provided through over 55 years of solid performance and in-depth
From 1968.... knowledge, AEC will continually work on his core competencies
to be increasingly customer-oriented and to create values for​​ its
shareholders.
Founded in 1968, the AEC group,
Allis Electric Co. Ltd, is a public company
Listed on the Taipei Stock Exchange since
In 2023 the group, headquartered in Taipei, counts
1994.
4 official branches and 11 offices with service centers
Global leader in the field of
highly specialized and available 24/7.
critical electrical infrastructures, digital
Spare parts stocked in over 21 countries.
and telecommunications, the AEC group
has been specializing in the production
of uninterruptible power supplies for the
Products manufactured and marketed by us can
protection of the power supply of
be supported and assisted anywhere in the world, the
industrial installations.
our network of offices allows us to cover whatever
Technology and design come together
time zone and almost all countries in the world.
to create continuity systems cutting-edge,
robust and efficient.

In 1994, the AEC group, now a solid reality with over 30 years of
experience, it is listed on the Taipei stock exchange through an offer
public launch that was hugely successful.
Stock exchange listing and strategic alliances with partners
Europeans have allowed it to continue its steady growth
and to venture into the telecommunications and high-end sector
technology, designing and developing products qualitatively
without equal.
All products manufactured by AEC are guaranteed by certificates
ISO 9001 quality, ensuring customers the utmost seriousness
production and reliability over time.
Our history 7

The AEC group, Allis Electric Co., has been listed on the Taipei Stock Exchange
since 1994. Our company has a capitalization of over 900 million dollars and
a staff of 800 employees located in 4 main commercial and production sites
located in Italy, Taiwan, USA, Japan and South Africa.

Our presence in the world and breakdown of global markets


1998 | AEC UPS Italy is born...
by geographical area
The Italian branch, based in Lainate in
province of Milan, founded in 1998 thanks Allis Electric supports the Asian and Oceanic market, PHD PowerHouse (AEC
to a partnership between Allis Electric Co. e South Africa) is concentrated exclusively in the local market in the Republic
the entrepreneur Doctor Bruno Carozzi, of South Africa, Miami-based AEC USA is responsible for the market
boasts over 30 years of history in the world of US, while AEC UPS Italy deals with the European markets, African, Middle Eastern
critical infrastructures and continuity systems. and Central \ South Americans.
AEC UPS Italy specializes in the production, Thanks to the solidity and the very high quality standard of the AEC Group, the
marketing and installation of UPS UPS always is very successfull and find local distributors in about 80 countries.
uninterruptible power supplies for protection In particular in Italy AEC opens several agencies in all regions and local technical
of the power supply of industrial plants high- assistance centers.
tech and telecommunications.
Our Italian team enjoys an experience multi-
year in the electronics sector, and is mainly Design, development, construction and testing
composed of engineers and specialized We do everything in our factory ...
technicians located throughout the Italian
AEC designs, develops and manufactures its products in its own factory, in
peninsula.
order to have greater control over the quality and reliability of everyone the
The strategic position in central Europe of
components, working closely together with the entire production cycle,
AEC Italy favors timely support technical-
pre / post sales and subsequent installations and maintenance. This radical
commercial and rapid deliveries in all over
strategy allows us to maintain a constant improvement process, carefully
Europe, Africa and the Middle East.
monitoring customer feedback and listening to it as valuable tips for applying
optimizations and functions in a timely manner additional requests from the
market.
AEC Group | Financials

FINANCIALS
AEC GROUP
Constancy, attention to detail and attention to the
customer are just some of our pillars.
From 1968 to today ... $295 MILIONS
TURNOVER IN 2023
AEC was originally a supplier of OEM machinery to manufacturers Critical Power: production and sale of UPS &
Italians and Europeans who use their own brand, while today AEC CPSS continuity systems, and lead or lithium
promotes its brand as a leading manufacturer in the industry and battery storage systems.
for some years it has delocalized and diversified its production which Renewable energies: among the first
it is not only Asian, but it is present with several factories in the designers of photovoltaic inverters, AEC
States United and in Italy to meet the needs of different markets is today an important player in the world
locals. of solar, marketing string and storage PV
inverters for residences and industries.
This continuous improvement process, as well as having an Electrical Mobility: to meet the looming
advantage direct and beneficial on sales and after-sales assistance need to transit from fossil fuel to electric
sale, strengthen the reputation of AEC as of more and more a vehicles, we are committed to offering a
serious, dynamic company attentive to technological progress e wide range of charging stations for electric
qualitative, always in total harmony and respect for the environment. vehicles.

Become AEC PARTNER

Become part of the AEC family with the program


PARTNERSHIP aimed at all customers of our group.

By joining the AEC PARTNERSHIP program, our partners


will enjoy additional benefits and privileges.
AEC partners will have access to all calculation by our
engineering team, maximum discounts for large retailers,
incentive program on sales with annual bonuses and
marketing program rewards to support our marketing
expenses partner.
AEC Group | Financials 9

The AEC expansion program


Development and innovation ...

CONSTANT AND SOLID GROWTH OF THE AEC GROUP


300 Mln $

200 Mln $

150 Mln $

100 Mln $

50 Mln $

2016 2017 2018 2019 2020 2021 2022 2023

800+ $ 295.550.000 $ 950.000.000


Total employees Total turnover Market Capitalization

+28% +48% +12.5%


Global Sales UPS Global Sales PV Inverter UPS Market share

Uninterruptible Power Supply Solar Inverter Photovoltaic Our passion, our core business...
OEM Productions in Europe ON-OFF Grid System | PV Inverter Battery | Storage Systems
Despite all the difficulties + 42% UPS sales The main core business of AEC,
due to the pandemic it has + 27% sales of PV solar inverters the world of UPS is giving great
hit our planet, the AEC group + 31% sales of 12V batteries satisfaction in terms of growth and
managed to conclude one of the The AEC group continues its our group persists in increasing
best years ever, reaching over 184 growth and increases sales of its market share, especially in the
million dollars in global turnover. all 3 of its departments. Italian national market.
Our services

OUR
SERVICES
Our team of dedicated experts is always available to evaluate and analyze the infrastructures on which the customer’s reality
operates. Our company offers a very varied and complete range of services, our specialized technicians are able to support our
customers’ projects in all their aspects, from design, to implementation and maintenance.

Design and engineering consultancy, installation of UPS and PV Inverter devices, maintenance of critical infrastructures, lead-
acid battery changes and diesel generator tests, are just some of the services that AEC carries out daily for various customers
throughout our peninsula.

CONSULTING PRE-SALE SUPPORT AFTER SALES SUPPORT

360 degree advice on any Our call center is available 24 hours Technicians located throughout the
critical infrastructure and facilities for per day also on WhatsApp or via peninsula Italian are available for
renewable energies. Our engineers our Live Chat on the aecups.com website. support after-sales interventions. In
they specialize in the study of Our operators will reply to synergy with our call center, the
feasibility and design of structures any of your doubts and they will be our service of technicians will be able
for data centers and photovoltaic able to direct you to the products to provide quick assistance by telephone
systems from scratch or to be restored. best suited to your needs. or through on-site intervention.
Our services 11

TECHINCAL ASSISTANCE WHATSAPP 24/7


Immediate technical support via WhatsApp or telephone, our call center for technical assistance
is active 24 hours a day 7 days a week and is always available to support the resolution of any
problems that may arise, even on non-working days and hours.

Do you have a technical or commercial question?


We reply on WhatsApp in less than 30 minutes...

INSTALLATIONS ASSISTANCE MAINTENANCE

Surveys and UPS installations for Assistance is one of the flagships Maintenance is very important
critical infrastructure. AEC technicians of the AEC group, which offers its of the electronic devices installed, for
are highly qualified for installations of customers a continuous service thanks this AEC makes various available
UPS and battery cabinets of various to which it is always possible to find a maintenance programs and contracts,
brands of UPS manufacturers. technician and solve problems around with the ability to customize
Commissioning and verification of all the clock. AEC always aims to obtain the assistance according to the needs of the
device values ​​and parameters. maximum customer satisfaction. customer and user.
OUR
SOLUTIONS
Ad hoc customized solutions based on the specific requests of the user, meticulous design and feasibility study for all projects
carried out by AEC. We are well aware that there is no longer a standard solution to all situations, and for this reason AEC has
always been dedicated to the development of innovative solutions based on customer feedback.
Our team will follow you step by step in choosing the most advantageous solutions to your situation!

CRITICAL POWER RENEWABLE ENERGIES ELECTRICAL MOBILITY


UPS AND BATTERIES 12V PV INVERTER & ENERGY STORAGE EV CHARGING STATION
UPS SYSTEMS SOLAR PHOTOVOLTAIC ELECTRIC VEHICLES

AEC has always focused on While most fossil raw materials With over 53 years of experience
research and development of are being depleted, electricity in the power electronics sector
new technologies and, especially and energy needs are increasing and more than 30 in the renewable
in recent years, has invested in all countries of the world. The energy sector, the AEC group has
heavily in the development of scarcity of materials and the leveraged and put its expertise
modular UPS with innovative rising cost of electricity are more into play to develop and build a
hot-swappable N + 1 technology. than ever global struggles for wide range of charging stations for
New powers also available in which our group is constantly electric vehicles. , available in both
a single 1250kVA UPS solution working on innovative solutions alternating current and super fast
with 10 125kW modules. UPS, with low environmental impact. direct current modes. Our range
uninterruptible power supplies, Our aspiration is to incentivize of EV solutions is able to support
are the main business of AEC, and promote renewable and the most varied needs in terms
which thanks to its significant ecological energies in a significant of power needed, installations in
investments has always managed and incisive way. For this reason private or public environments,
to offer products of the highest we develop ever more efficient such as hospitality or healthcare
quality and reliability. Among the technologies and systems. facilities, shopping and recreation
most advanced technologies in the As a diversified industrial group centers, companies, congress
world of power electronics, AEC with extensive engineering centers, public car parks and large
uses the 3-level IGBT topology capabilities, AEC provides state- supermarkets.
with redundant components, of-the-art products, services and
guaranteeing maximum reliability solutions to meet the insatiable
also through an extended 3-year growing energy needs around the
warranty, which can be extended world.
by means of a maintenance
contract at our service centers.
authorized.
13

DATA CENTER, THE IMPORTANCE OF UPS FOR THE


BUSINESS CONTINUITY ...

Thanks to the support of qualified and professional technicians, AEC is


able to assist and guide its customers in choosing the most suitable
solution for them.

Nowadays the use of data centers in the productive world is growing dramatically as they are of fundamental
importance to support the continuous technological development of our planet. If until a few decades ago the
interruption of the operation of a data center would not have caused great inconvenience, today we must always
remain vigilant and ready to intervene in the event of system failure.

For this reason, UPS uninterruptible power supplies are an indispensable element for the correct and continuous
operation of data centers and there are several factors to consider when evaluating the type of UPS to install.
15

CRITICAL POWER
UPS, CPSS & BATTERIES
Critical Power - UPS, CPSS & Batteries

UPS Online single-phase IST3 1-10kVA 16

UPS Online single-phase rack IST3J 1-10kVA 20

UPS Online lithium rack IST8 1-3kVA 24

UPS Online All-In-One Lithium All-In-One 10-20kVA 28

UPS Online three phase rack IST9 10-20kVA 34

UPS Online three phase IST7 10-40kVA 38

UPS Online three phase IST7 60-200kVA 42

UPS Transformer based IST7T 80-600kVA 48

UPS Modular IST6 30-1200kVA 54

Lithium Battery - Cabinets and Modules

L6 Cabinet and Modules L6 40Ah-100Ah 62

Emergency System - CPSS EN50171 68


CPSS EN-50171 CPSS7 10-40kVA 70

CPSS EN-50171 CPSS7 60-200kVA 72

Battery Cabinets 74

Accessories for UPS - CPSS EN50171 86

Lead-acid Batteries 12V VRLA

Battery 12V | 9Ah 90

Battery 12V | 24Ah 92

Battery 12V | 40Ah 94

Battery 12V | 60Ah 96

Battery 12V | 80Ah 98

Battery 12V | 100Ah 100


UPS SERIES IST 3

Power from 1kVA to 10kVA

1:1

UPS TOWER ONLINE DOUBLE CONVERSION


IST3 single-phase UPS (1-10kVA) are AEC’s double conversion online UPS range and
are tower UPSs with powers starting from 1kVA up to 10kVA. The UPS IST3 series
adopts the most innovative IGBT technologies, ensuring efficiency up to 96% and a
unitary output power factor.

The UPS are available in models with internal batteries or combined with external
battery cabinets for longer runtimes. The 6kVA and 10kVA UPSs include the manual
bypass disconnector to allow correct maintenance without interrupting the output.
The USB card is included and the product range is covered by a 3-year warranty.
The UPS comply with the CEI 0-16 standard.

UPS ONLINE TOWER


UPS Online single-phase 17

PRINCIPALS FEATURES
EXCELLENT PERFORMANCE
• Output power factor equal to 1 for a better load capacity • In compliance with the CEI-016 standard, the Charge
at the same power with lower and more convenient reserve function allows the batteries to maintain an
initial investment costs; energy reserve to always guarantee the rearming of the
coil and the restoration of full functionality of the cabin;
• Efficiency AC\AC up to 96%;
• Advanced DSP digital control technology for precise and
speed data processing;

• Detection and warning of faults to ensure the safety of


the device, also monitoring the internal temperature of
the UPS;

• Intelligent fans with high efficiency cooling, multiple


modes to control their speed, extend their life and
improve their efficiency.

• Small size and dustproof front design with LCD display;

• Wide input tolerance, compatible with diesel generators;


Automatic fan control

STANDARD AND COMMUNICATIONS


• Large HD screen with graphic interface and simplified • Maintenance bypass switch (6-10kVA);
display, for an improved and user-friendly user
experience; • 16 \ 17 \ 18 \ 19 \ 20 battery configuration via RS232
port (6-10kVA);

• RS232 and USB communication ports; the UPS is


equipped with a user manual, cable and CD for software;

• SNMP network card for remote control and monitoring


(optional);

• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • NC \ NO dry contact card for alarms (optional).
configurable from on-site display;

• ECO mode configurable from on-site display;

WARRANTY

ASSISTANCE
IST3 1 KVA

EPO emergency release

RS232 USB\SNMP\Contact card

Label
2 x Socket Schuko

Fan

Connector for external batteries


Power supply

IST3 2-3 KVA

EPO emergency release

RS232 USB\SNMP\Contact card


Label
3 x Socket Schuko

Fan

Connector for external batteries Short circuit protection


Power supply

IST3 6-10 KVA


EPO emergency release

USB\SNMP\Contact card
RS232

Ventilation grid Maintenance Bypass

Power switch, bypass and


battery
Terminal for cables,
power supply ,output, Grounding
battery and ground

Label

Wheels
IST3-L 6-10 KVA

EPO emergency release

USB\SNMP\Contact card
RS232

Label

Ventilation grid

Power and bypass switch

Terminal for cables,


power supply, output,
battery and ground
UPS Online single-phase 19

TECHNICAL SPECIFICATIONS

IST3-1-2X9 IST3-2-4X9 IST3-3-6X9 IST3-6-16X9 IST3-10-16X9


MODELS
IST3-1-L IST3-2-L IST3-3-L IST3-6-L IST3-10-L
INPUT
VOLTAGE (VAC) 120~295 80~275
FREQUENCY (HZ) 50/60± 10% (50/60Hz automatic regulation)
POWER FACTOR ≥0.99
THDi <5%
OUTPUT
POWER (WATT) 1000 2000 3000 6000 10000
MAX. AC/AC EFFICIENCY 92,00% 93,00% 94,00% 96%
POWER FACTOR 1
VOLTAGE (VAC) 208/220/230/240±1% (configurable from display)
FREQUENCY (HZ) 50/60±0.2% (battery mode)
THD < 2% (linear loads ) THD < 1% (linear loads)
THDi
THD < 5% (non-linear loads) THD < 4% (non-linear loads)
SWITCHING TIME (MS) 0
BATTERIES
VOLTAGE (VDC) 24 or 36 48 or 72 72 or 96 192~240
STANDARD BATTERIES
2×9Ah 12V 4×9Ah 12V 6×9Ah 12V 16×9Ah 12V 16×9Ah 12V
CONFIGURATIONS
MAX. CHARGING CURRENT (A) 1-4 1-4 1-4 1~8
OTHER SPECIFICATIONS
RS232, EPO, USB (slot)
COMMUNICATIONS
(SNMP, RS485+ Optional dry contact Card)

OUTPUT SOCKET 2x Schuko plugs 3x Schuko plugs Screw wire terminal

ALLARMS Low batteries, Abnormal Input, Overload, Block/Fault, ecc.


PROTECTIONS Low batteries, Overload, Short-circuit, Over-temperature, ecc.
NOISE (DB) <50 <55
TEMPERATURE (°C) -5~40
HUMIDITY 0 ~ 95%
DIMENSIONS (L×W×H) MM 145×360×225 190×400×330 230×502×553 / 190×422×337 (L)
WEIGHT (KG) 11.6/4.5 22.4/8.5 27.6/9.2 54.5/10.9 56.2/12.5
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


UPS SERIES IST 3-J

Power from 1kVA to 10kVA

1:1

UPS RACK 19” ONLINE DOUBLE CONVERSION


The IST3-J single-phase UPS (1-10kVA) are AEC’s double conversion online UPS range
and are rack UPS with powers from 1kVA up to 10kVA. The UPS IST3-J series adopts
the most innovative IGBT technologies, ensuring efficiency up to 96% and a unitary
output power factor.

The UPS are available in models with internal batteries or combined with external
battery rack cabinets for longer autonomy. Our 1kVA, 2kVA and 3kVA models have the
hot-swappable battery pack which facilitates quick replacement. The 6kVA and 10kVA
models have the advantage of occupying only 2U. The USB card is included and the
UPS are covered by a 3 year warranty.

UPS ONLINE RACK 19”


UPS Online rack 19” 21

PRINCIPALS FEATURES
EXCELLENT PERFORMANCE
• Output power factor equal to 1 for a better load capacity • Small footprint of only 2U even for 6 and 10kVA models;
at the same power with lower and more convenient
initial investment costs; • Possibility of installation in 19-inch rack or tower;

• Efficiency AC\AC up to 96%; • Advanced DSP digital control technology for precise and
Efficienza
rapid data processing;
100,00%

• Detection and warning of faults to ensure the safety of


97,50%
the device, also monitoring the internal temperature of
the UPS;
95,00%

• Intelligent fans with high efficiency cooling, multiple


92,50%
modes to control their speed, extend their life and
90,00% improve their efficiency.
0% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Carico

• Small size and dustproof front design with LCD display;

• Wide input tolerance, compatible with diesel generators;


Automatic fan control

STANDARD E COMMUNICATIONS

• Large rotary HD LCD screen, graphic interface and


simplified display for an improved and user-friendly user
experience;

• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • Maintenance bypass rack module (optional);
configurable from on-site display;

• ECO mode configurable from on-site display; • SNMP network card for remote control and monitoring
(optional);
• 16 \ 17 \ 18 \ 19 \ 20 battery configuration via RS232
port (6-10kVA); • NC \ NO dry contact card for alarms (optional).

• RS232 and USB communication ports equipped with user


manual, cable and CD for software;

WARRANTY

ASSISTANCE
IST3-J 1 KVA

1. OUTPUT SOCKET;
2. MAINS INPUT SOCKET;
3. OVER-CURRENT PROTECTOR;
4. EXTERNAL BATTERY PORT;
5. COOLING FAN;
6. EPO CONNECTOR;
7. RS232 COMMUNICATION PORT;
8. INTELLIGENT SLOT;

IST3-J 2-3 KVA

1. OUTPUT SOCKET;
2. MAINS INPUT SOCKET;
3. OVER-CURRENT PROTECTOR;
4. EXTERNAL BATTERY PORT;
5. COOLING FAN;
6. EPO CONNECTOR;
7. RS232 COMMUNICATION PORT;
8. INTELLIGENT SLOT;

IST3-J 6-10 KVA


Battery expansion port Input breaker Output socket
Parallel port (just for
parallel modules)

Communication Port
EPO

Cover

RS485 and dry


Over - current Intelligent slot
Sourge protection Wire terminal contact
protector (optional)
grounding wirwe SNMP
UPS Online rack 19”

TECHNICAL SPECIFICATIONS

IST3J-1-3X9 IST3J-2-4X9 IST3J-3-6X9 IST3J-6-16X9 IST3J-10-16X9


MODELS
IST3J-1 IST3J-2 IST3J-3 IST3J-6 IST3J-10
INPUT
VOLTAGE (VAC) 120~295 80~275
FREQUENCY (HZ) 50/60± 10% (50/60Hz Automatic regulation)
POWER FACTOR ≥0.99
THDi <5%
OUTPUT
POWER (WATT) 1000 2000 3000 6000 10000
MAX. AC/AC EFFICIENCY 92,00% 92.5% 93.3% 96%
POWER FACTOR 1
VOLTAGE (VAC) 208/220/230/240±1% (configurable from Display)
FREQUENCY (HZ) 50/60±0.2% (battery mode)
THD <2% (linear loads) THD <1% (linear loads)
THD
THD < 5% (non-linear loads) THD < 4% (non-linear loads)
SWITCHING TIME (MS) 0
BATTERIES
VOLTAGE (VDC) 36 48 72 192~240
16× 9AH 12V
QUANTITY 3× 9AH 12V 4× 9AH 12V 6× 9AH 12V
(16~20 configurable)

MAX. CHARGING CURRENT (A) 1-4 1-4 1-4 1/1~8 (configurable)

OTHER SPECIFICATIONS
RS232+EPO+USB (slot)
COMMUNICATIONS
(SNMP, RS485+ optional dry contact card)

OUTPUT SOCKET 8×IEC320 C13 8×IEC320 C13 + 1×IEC320 C19 Screw wire terminal

ALARMS Low batteries, Abnormal Input, Overload, Block/Fault, ecc.


PROTECTION Low batteries, Overload, Short-circuit, Over-temperature, ecc.
NOISE (DB) < 50 < 55
TEMPERATURE (°C) -5~40
HUMIDITY 0 ~ 95%
DIMENSIONS (L×W×H) 438×413×2U 438×570×2U 438×500×2U (UPS)+ 438×500×3U (Batt. pack)
WEIGHT (KG) 11 19.8 24.8 10.6+45/10.6 12.2+45/12.2
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


UPS SERIES IST 8

Power from 1kVA up to 3kVA

1:1

UPS ONLINE WITH LITHIUM BATTRIES


The IST8 single-phase lithium UPS (1-3kVA) are the range of rack UPS with lithium-
ion batteries produced by AEC, in powers starting from 1kVA up to 3kVA. The UPS IST8
series adopts the most innovative lithium-ion battery technologies, guaranteeing a
lifespan of the UPS up to 10 years.

The lithium UPS units are available in models with internal batteries or combined with
external battery cabinets for longer runtimes. The IST8 UPS is capable of withstanding
temperatures up to 50 ° without risking damage to the batteries.
5-years battery warranty.

LITHIUM ION UPS


Lithium ion UPS rack 19” 25

PRINCIPAL FEATURES
LITHIUM ION BATTERIES
• Output power factor equal to 1 for a better load capacity • In addition to being much lighter and less bulky,
at the same power with lower and more convenient lithium-ion batteries are also much more versatile
initial investment costs; and advantageous thanks to their ability to operate in
extremely cold temperatures.
• Integrated lithium-ion batteries, weight reduction up to Maximum operation at -20 ° C and up to + 50 °
40% compared to traditional lead-acid VRLA batteries, C, without any risk of damage o downgrading of
maximum discharge capacity up to 80% and an expected performance;
life of 15 years and over 1500 charging cycles;
• Possibility of installation in 19-inch rack or tower;

• Advanced DSP digital control technology for precise and


rapid data processing;

• Detection and warning of faults to ensure the safety of


• Small size and dustproof front design with LCD display; the device, also monitoring the temperature of the UPS;

• Wide input tolerance, compatible with diesel generators; • Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.

STANDARD AND COMMUNICATIONS

• Large rotary HD LCD screen, graphic interface and


simplified display for an improved and user-friendly user
experience;

• Output 208/220/230/240 Vac, 50 / 60Hz voltage, • Maintenance bypass rack module (optional);
configurable from on-site display;

• ECO mode configurable from on-site display; • SNMP network card for remote control and monitoring
(optional);

• RS232 and USB communication ports equipped with user • NC \ NO dry contact card for alarms (optional).
manual, cable and CD for software;

WARRANTY

ASSISTANCE
BUILT-IN LITHIUM-ION BATTERIES
EXCELLENT PERFORMANCE
• Higher energy density: Li-ion batteries lithium have a • Life cycles: Li-ion batteries have a cycle longer life
higher energy density than to lead-acid batteries, which than lead-acid batteries, i.e can be downloaded and
means they can store more energy in a smaller space. reloaded for a greater number of times before losing
their capacity.

• Lighter: Li-ion batteries are lighter compared to lead-


acid batteries, which makes them easier to transport
and install.

• Longer life: lithium-ion batteries have longer life than


lead-acid batteries e can be used for longer periods
without the need to replace them.

• Higher efficiency: Lithium-ion batteries have higher • Self-discharge: Li-ion batteries have a self-discharge
efficiency than lead-acid batteries, which means they lower than lead-acid batteries, which meaning they lose
can provide more energy for each unit of weight. less energy when not in use.

• Working voltage: Li-ion batteries have a higher


working voltage than al batteries lead, which means
they can deliver more energy for each unit of volume.

• Working temperature: lithium ion batteries they can


work in a wider range of temperatures compared to
lead-acid batteries.

• Greater flexibility: lithium-ion batteries can be used


in a wide range of applications and in different types of
devices, while the lead acid batteries are mainly used in
specific applications.

1. OUTPUT SOCKET;
2. MAINS INPUT SOCKET;
3. OVER-CURRENT PROTECTOR;
4. EXTERNAL BATTERY PORT;
5. COOLING FAN;
6. EPO CONNECTOR;
7. RS232 COMMUNICATION PORT;
8. INTELLIGENT SLOT;
Lithium ion UPS rack 19” 27

TECHNICAL SPECIFICATIONS
MODELS IST8-1-LI IST8-2-LI IST8-3-LI
INPUT
VOLTAGE (VAC) 120-295
FREQUENCY (HZ) 50/60± 10% (50/60Hz)
POWER FACTOR ≥0.99
THDI <5%
OUTPUT
POWER (WATT) 1000 2000 3000
MAX. AC/AC EFFICIENCY 92.7% 93.5% 96%
POWER FACTOR 1
VOLTAGE (VAC) 208/220/230/240±1%
FREQUENCY (HZ) 50/60±0.1
THD <3%
SWITCHING TIME (MS) 0
ECO MODE Yes
OVERLOAD 101%~115% for 1 min, 116%~133% for 1 s, < 134% for 200ms
LITHIUM BATTERIES
VOLTAGE (VDC) 24 48 72
BACKUP TIME (MIN) 12 12 12
MAX. CHARGING CURRENT (A) 4
OTHER SPECIFICATION
COMMUNICATIONS USB and SNMP (slot) (RS232+ Optional dry contact card)
OUTPUT SOCKETS (1)IEC C19 + (6)IEC C13
DISPLAY LCD
PROTECTIONS Low batteries, Overload, Short-circuit, Over-temperature, ecc.
NOISE (DB) < 55
TEMPERATURE 0°C~50°C
HUMIDITY 0 ~ 95%
DIMENSIONS (L×W×H) (MM) 438×420×87 438×570×87 438×570×87
WEIGHT (KG) 8.9 13.6 19.6
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


ALL-IN-ONE LITHIUM UPS

Power from 10kVA up to 20kVA

1:11:1 3

ALL-IN-ONE UPS WITH HOT-SWAPPABLE LITHIUM BATTERY


UPS ONLINE THREE-PHASE OR SINGLE PHASE
The ALL-IN-ONE UPS + LITHIUM BATTERY MODULES (10-20KVA) are AEC’s
revolutionary UPS System with powers starting from 10kVA up to 20kVA. The integrated
UPS adopts the most innovative 3-level IGBT technologies, ensuring efficiency up to
97% and a unitary output power factor.

All-In-One can be configured in 1\1 or 3\1 or 3\3 input\output mode directly from
the display. The All-In-One Cabinet is on wheels and it includes an online UPS upto
20kW, a distribution module with manual maintenance bypass and up to 8 slots for
Hot-swappable Lithium battery modules 50Ah.

UPS RACK 19” THREE-PHASE


All-In-One | UPS + Lithium 29

UPS + LITHIUM BATTERIES | ALL-IN-ONE SOLUTION


Touch-screen display

UPS 10-20kW
1:1 or 3:1 or 3:3

Power distribution switch - MBB

Lithium 50Ah battery pack


Redundant and Hot-swappable

Module-level expansion with fine


granularity

UPS CONFIGURATIONS HOT-SWAPPABLE LITHIUM MODULES

• UPS Online double-conversion 10kVA or 20kVA; • Maximum 8 x Lithium-Ion Hot-swappable 50Ah ;


200 Minutes autonomy on 6kW
• UPS input and output configurable from display in 120 Minutes autonomy on 10kW
single-phase and \ or three-phase (1:1, 3:1, 3:3);
• 15 Years lifespan and over 3000 cycles DoD 50%;
• ECO-Mode mode configurable from on-site display;
• Electrical and physical double isolation;
• Two Displayes: 1 LCD and 1 computerized Touch-Screen;
• From 0% charge to 100% charge in 2 Hours;
• Configuration for input, output, bypass, batteries,
communications, language and operating modes via • Module fire protection;
display from UPS or TOUCH-SCREEN;
• Modular parallel design, 100% hot-swappable
• Output power factor equal to 1; independent and redundant modules;

• AC \ AC efficiency up to 97%; • Preventive Failure alarm and module exit automatically;

• Innovative three-level IGBT technology integrated in the • Advanced BMC communication to allow mixing old and
inverter section; new Lithium-Ion Modules.

• Maintenance Bypass integrated.


DISPLAY | TOUCH-SCREEN COMPUTERIZED

Display 4.9" Inches

Safe and reliable Smart and Intelligent technology


Electrical and physical double isolation Module design, plug and play
• Port zero voltage, no risk of short circuit shock • 5mins maintenance, reduce the OPEX cost

Two-level fire linkage Flexible for expansion


• Module fire protection • Module design, can expand the capacity of modules or
• Can quickly, accurately and effectively detect and extinguish cabinets.
the fire source will extinguish the fire in the initial stage. • Reduce the CAPEX cost

Failure module exit automatically Smart battery test


• Modular parallel design, failure module exit automatically, • Parallel design, the battery can test the capacity separately.
will not affect the system. Other modules can work normally. No need to cut off the power supply, improve the reliability

Featured Two-layer BMS Architecture


The adopted two-layer BMS architecture (PBMU/MBMU) ensures the reliability of lithium-ion battery system from
cell, module and system layers.

RS485 TCP/IP
NetEco

UPS Layer II Network management server


MBMU
unit

CAN CAN

Battery module (Built-in PBMU) Battery module (Built-in PBMU)


All-In-One | UPS + Lithium 31

ACCURATE MONITORING FROM DISPLAY


Easy and simple to operate

Intelligent current equalization


• Can be used with new and old batteries
• Can be used with lithium-ion batteries from different suppliers

Intelligent voltage equalization


Phase I
• Intelligent voltage equalization module, no barrel effect
old battery
• Prolong the backup time, improve battery utilization SOH=88%
Phase II
Fault recording, early warning old battery
• Fault recording, early warning, accurate and quick fault location, SOH=91%
reduce the OPEX cost Phase III
new battery
Adaptive SOC management
SOH=95%

• Intelligent charge and discharge management, avoid over charge


and over discharge
• Detects the battery internal temperature. Improve the safety and More flexible mixing of old and new batteries
reduce the OPEX cost

Multi-Password management Communications and alarms

• Access to the menu via different password levels • Alarms from dry contact card 5 or 12 Input\Output
available alarms (optional);
(User, Technician and Manufacturer);
• SNMP Network Card for remote monitoring and
• Large memory up to 10,000 events downloadable via the USB
controling (optional).
port integrated in the UPS;

Excellence performance Lithium-Ion


• Higher energy density: Li-ion batteries lithium have a • Life cycles: Li-ion batteries have a cycle longer life
higher energy density than to lead-acid batteries, which than lead-acid batteries, i.e can be downloaded and
means they can store more energy in a smaller space. reloaded for a greater number of times before losing
their capacity.

• Lighter: Li-ion batteries are lighter compared to lead-acid


batteries, which makes them easier to transport and install.

• Longer life: lithium-ion batteries have longer life than lead-


acid batteries e can be used for longer periods without the
need to replace them.

• Higher efficiency: Lithium-ion batteries have higher


efficiency than lead-acid batteries, which means they can
5
provide more energy for each unit of weight.
LITHIUM VS LEAD ACID COMPARISON TABLE
1. Example UPS = 20kVA Load = 20kW Autonomy = 60 Minutes
LEAD ACID VRLA SOLUTION: LITHIUM SOLUTION:

UPS IST7 20kVA - 20kW ALL-IN-ONE 20kW


BB7 + 32 Batteries x 12V 80Ah with 8 x Lithium 50Ah
1. Total Weight 50 Kg + 650 Kg 400 Kg
2. Total piece to install 2 Units = UPS + Battery Cabinet 1 Unit
3. Dimensions 260x780x900 cm + 800x800x1400 cm 600x860x1200 cm
4. Cycles discharge 300 Cycles DoD 30% 3000 Cycles DoD 50%
5. Life-span of batteries 10 Years 15 Years
6. Time to recharge 100% 8 Hours 2 Hours
7. Working temperature 20-25° 0-50°
8. Warranty 2 Years 5 Years
9. Time to install full system 2 People 2-4 Hours 1 Person 30-60 Minutes
10. Battery replacements 2-3 Times
0
needed in 15 years x 600Kg of batteries
12. Estimated Total Cost in 15 65.000 Euro 40.000 Euro
Years

Physical Appereances

BATTERY AUTONOMY CONFIGURATION TABLE


50Ah battery module | 15 Years life span
Battery module
(mins) 1 2 3 4 5 6 7 8
UPS capacity (kW)
6 25 50 75 100 125 150 175 200
10 15 30 45 60 75 90 105 120
20 / 15 22 30 37 45 52 60
UPS rack 19” three-phase 33

TECHNICAL SPECIFICATIONS

MODELS ALL-IN-ONE
UPS INPUT
CONFIGURATION 1:1 3:1 3:3 INPUT - OUTPUT
VOLTAGE (VAC) 80-280 (L-N) or 138-485 (L-L)
FREQUENCY (HZ) 40-70
POWER FACTOR ≥0.99
THDI <3%
UPS OUTPUT
POWER (kW) 10 15 20
MAX. AC/AC EFFICIENCY 97,00%
POWER FACTOR 1
VOLTAGE (VAC) 220/230/240±1% (L-N) or 380/400/415±1% (L-L) (configurable)
FREQUENCY (HZ) 50/60±0.1
THD THD <2% (linear loads), THD < 4% (non-linear loads)
SWITCHING TIME (MS) 0
ECO MODE Yes
115%~130% Overload for 15mins, 130%~150% Overload for 1min,
OVERLOAD
more than 150% Overload for 200ms
LITHIUM-ION BATTERY MODULES
LITHIUM-ION MODULES L6-50-4C-240-X
BATTERY TYPE
HOT-SWAPPABLE MODULES
BATTERY NUMBER Maximum 8 LITHIUM MODULES
BATTERY RATED VOLTAGE (V) 57.6
BATTERY CAPACITY (AH) 50
MAX. ENERGY (KWH) 2.8
DC/DC RATED OUTPUT POWER (KW) 10
RATED OUTPUT VOLTAGE (V) 240/±240/480
SOC ACCURACY ≥95%
HUMIDITY 0 ~ 95%
UPS 438×500×130(3U)
Distribution Box 438×500×130(3U)
DIMENSIONS (L X W X H)
Lithium Battery Module 223×665×153
FULL UPS SYSTEM 600×860×1200
UPS 20
Distribution Box 8
WEIGHT (KG)
Lithium Battery Module 38±2
FULL UPS SYSTEM 120 *Without built-in UPS and batteries.
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
UPS SERIES IST 9

Power from 10kVA up to 20kVA

1:1 3:1 3:3

UPS RACK 19” ONLINE THREE-PHASE OR SINGLE PHASE


The IST9 Rack UPS (10-20KVA) are AEC’s range of single-phase and three-phase
online rack UPS, with powers starting from 10kVA up to 20kVA. The UPS IST9 series
adopts the most innovative 3-level IGBT technologies, ensuring efficiency up to 97%
and a unitary output power factor.

IST9 can be configured in 1 \ 1 or 3 \ 1 or 3 \ 3 input \ output mode directly from the


display. 19 ”rack UPS compact in size, only 3U in rack cabinet height. The UPS includes
a distribution module and a manual bypass disconnector to facilitate maintenance.

UPS RACK 19” THREE-PHASE


UPS rack 19” three-phase 35

PRINCIPAL FEATURES
EFFICIENCY AND FLEXIBILITY
• Output power factor equal to 1 for a better load capacity • Extremely flexible input adaptable to all needs, tolerance
at the same power with lower and more convenient range -60% ~ + 25%;
initial investment costs;
+25%

• Very high AC \ AC efficiency up to 97%;

- 60%
• Innovative three-level IGBT technology integrated in the
inverter section;

• Continuous overload up to 115%;


Single-phase and three-phase power range

• Ultra-wide range of batteries, from 12 up to 20


monoblocks; • Small footprint with small size only 3U;

• Advanced control with double redundant DSP;


DSP DSP

• Fully tropicalized electronic cards;

• Charging current for batteries from 1 to 10 A,


configurable from the display;
UPS
• Shared batteries for parallel systems, a single battery
pack for two N + 1 UPSs;

• ECO mode with efficiency up to 99%, configurable from


the display;
Battery pack Distribution Module -
16 x 12V\9Ah (3U) Maintenance bypass Static Bypass
(3U)

MULTIPLE CONFIGURATIONS Rectifier Inverter


Load

• Large rotary HD screen, graphic interface and simplified


Batterie

ECO Mode
display, for an improved and user-friendly user
experience;
• Battery configurations minimum 24 up to 40 per series
(± 144 ~ ± 240Vdc) via display;
• UPS input and output configurable from display in
single-phase and \ or three-phase (1: 1,3: 1,3: 3);
• Possibility of parallel installation (redundant or power)
up to 4 units;
• ECO, Normal or Parallel N + 1 mode configurable from
on-site display;
• Display available in 7 languages.

• Configuration for input, output, bypass, batteries,


communications, language and operating modes via
display;
EXCELLENT PERFORMANCE
100%

• Efficiency higher than 93% even at low loads;


98%

• Maximum output tolerance, ability to operate with 100%


unbalanced loads; 95%

• Maximum power density, 20kW of capacity take up only


93%
3U of size;

• Access to the menu via different password levels, 90%

input-output-battery configuration directly from 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

display;
ECO Efficiency
AC/AC Efficiency
• Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.

Automatic fan control

STANDARD AND COMMUNICATIONS Cable terminal IN-OUT-BYP Parallel (only for PRL models)

RS485

• Rack module for electrical distribution with switches for


Input, Static Bypass, Output and Maintenance Bypass;

• RS485 communication port with integrated Modbus;


EPO - Release
button
• EPO, emergency release button; Contact NC\NO for
maintenance and
emergency bypass
• Kit for 1: 1 and/or 3: 1 installation (optional);
Cable Terminal IN-OUT-BYP-BATT
DISTRIBUTION MODULE SNMP / Contact Card

• Support for installation in tower \ floor version;

• USB communication port equipped with user manual,


cable and CD for software;

• SNMP network card for remote control and monitoring


(optional);

• NC \ NO dry contact card for alarms (optional).


UPS rack 19” three-phase 37

TECHNICAL SPECIFICATIONS

MODELS IST9-10 IST9-15 IST9-20


INPUT
VOLTAGE (VAC) 80-280 (L-N) o 138-485 (L-L)
FREQUENCY (HZ) 40-70
POWER FACTOR ≥0.99
THDI <3%
OUTPUT
POWER (kW) 10 15 20
MAX. AC/AC EFFICIENCY 97,00%
POWER FACTOR 1
VOLTAGE (VAC) 220/230/240±1% (L-N) o 380/400/415±1% (L-L) (configurable)
FREQUENCY (HZ) 50/60±0.1
THD THD <2% (linear loads), THD < 4% (non-linear loads)
SWITCHING TIME (MS) 0
ECO MODE Yes
115%~130% Overload for 15mins, 130%~150% Overload for 1min,
OVERLOAD
more than 150% Overload for 200ms
BATTERIES
VOLTAGE (VDC) ±192 (±144~±240 configurable)
MAX. CHARGING CURRENT (A) 4 (1-10 configurable)
OTHER SPECIFICATIONS
COMMUNICATIONS RS485+EPO (RS232+ Clean contact card, SNMP optional)
DISPLAY LCD
ALARMS Low batteries, Anormal input, Overload, Block/Fault ecc.

PROTECTION Low batteries, Overload, Short-circuit, Over-temperature ecc.

NOISE (DB) < 55


TEMPERATURE (°C) -5~40
HUMIDITY 0 ~ 95%
UPS 438×500×130(3U)
DIMENSIONS (L×W×H) MM
Distribution Box 438×500×130(3U)
UPS 20
WEIGHT (KG)
Distribution Box 8
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


UPS SERIES IST 7

Power from 10kVA to 40kVA

3:1 3:3

UPS ONLINE THREE-PHASE | SINGLE PHASE


The IST7 three-phase UPS (10-40kVA) are AEC’s three-phase online UPS range,
double conversion tower UPS in powers starting from 10kVA up to 40kVA. The UPS
IST7 series adopts the most innovative 3-level IGBT technologies, ensuring efficiency
up to 97% and a unitary output power factor.

IST7 10kVA and 20kVA can be configured in 1 \ 1 or 3 \ 1 or 3 \ 3 input \ output


mode directly from the display, while the 30kVA and 40kVA models can be configured
3 \ 1 or 3 \ 3. The three-phase UPS are available in version with internal batteries
or external battery cabinet. The UPS includes the free contact card for alarms and a
manual bypass disconnector to facilitate maintenance.

UPS THREE-PHASE | SINGLE PHASE


UPS Three-phase | Single phase 39

PRINCIPALS FEATURES
EFFICIENCY E FLEXIBILITY
• Output power factor equal to 1; • Advanced control with double redundant DSP;

• AC \ AC efficiency up to 97%; DSP DSP

100%
• ECO mode with efficiency up to 99%, configurable from
the display;
98%

• Maximum output tolerance, ability to operate with 100%


95%
unbalanced loads;

• Fully tropicalized electronic cards;


93%

• Double input with wide tolerance, compatible with diesel


90% generators;
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

+25%
ECO Efficiency
AC/AC Efficiency
- 60%
• Innovative three-level IGBT technology integrated in the
inverter section;

• Modifiable input and output: Single-phase and three-phase power range


• 1:1, 3:1, 3:3 (10-20kVA)
• 3:1, 3:3 (30-40kVA);
• Ultra Wide Battery Range:
• Maximum capacity of built-in batteries: • 10kVA version minimum 16 up to 40 for
• from 16 up to 40 12V 9Ah monoblocks (10-20kVA); monoblocks series (± 96 ~ ± 240Vdc)
• from 48 up to 80 12V 9Ah monoblocks (30-40kVA); • 20-30-40kVA version minimum 24 up to 40 for
monoblocks series (± 144 ~ ± 240Vdc);

• ECO mode with efficiency up to 99%, configurable from


the display;
MULTIPLE CONFIGURATIONS
• Advanced 3-stage battery charging and maintenance
• TOUCH-SCREEN computerized screen with Linux system;
operating system and color graphic interface;

• 10kVA and 20kVA versions with input and output


configurable from display in single-phase and \ or three-
phase (1: 1,3: 1,3: 3);
3 Stadi di ricarica

• 30kVA and 40kVA versions with configurable output • Shared batteries for parallel systems, a single battery
from display in single-phase or three-phase (3: 1,3: 3); pack for two N + 1 UPSs;

• Display available in 7 languages; • Possibility of parallel installation N + 1 (redundant or


power) up to 10 units.
SETTINGS FROM DISPLAY

• Access to the menu via different password levels (User,


Technician and Manufacturer);

• Configuration for input, output, bypass, batteries,


communications, language and operating modes;

• Periodic self-cleaning function, to expel impurities and


reduce the risk of failure;

• Large memory up to 10,000 events downloadable via the


USB port integrated in the UPS;

• Advanced communication for installation and operation


with diesel generators;

• Alarms from clean contact card, configurable from


display;

Display 4.9" Inches

STANDARD AND COMMUNICATIONS


• Clean contact card with 5 alarms; • Integrated RS485 and Modbus communication port;

• Maintenance bypass switch; • Wiring arrangement for internal batteries:


• from 16 up to 40 12V 9Ah monoblocks (10-20kVA)
• EPO emergency release button on the front, remote • from 48 up to 80 12V 9Ah monoblocks (30-40kVA);
clean contact on the back;
• Protection against reverse polarity of the batteries;
• Battery start-up by means of a specific button;
• SNMP network card for remote control and monitoring
• Kit for 1: 1 and \ or 3: 1 installation (optional); (optional);

• Integrated external battery connector; • NC \ NO dry contact card for further 12 alarms
(optional).
UPS Three Phase - Single Phase 41

TECHNICAL SPECIFICATIONS
IST7-10-32X9 IST7-20-36X9 IST7-30-72X9 IST7-40-72X9
MODELS
IST7-10 IST7-20 IST7-30 IST7-40
INPUT
VOLTAGE (VAC) 80-280 (L-N) / 138-485 (L-L)
FREQUENCY (HZ) 40~70
VOLTAGE BYPASS (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3:3 / 3:1 / 1 : 1 3:3 / 3:1
OUTPUT
POWER (kW) 10 20 30 40
POWER FACTOR 1
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD THD<1% (linear loads), THD <3% (non- linear loads)
WAVEFORM Sinusoidal pure, THD<1% linear
EFFICIENCY 97%
110% Overload for 60mins; 130% Overload for 10mins;
OVERLOAD
155% Overload for 1min; >155% Overload for 200ms;
BATTERIES
BATTERY VOLTAGE (VCC) ±96~±240 configurable ±144~±240 configurable ±144~±240 configurable ±144~±240 configurable
BATTERIES CONFIGURATION STANDARD 32*9AH/12V 36*9AH/12V 72*9AH/12V 72*9AH/12V
MAX. CHARGING CURRENT (A) 1-10 (configurable) 1-20 (configurable)
OTHER SPECIFICATIONS
COMMUNICATIONS RS485, MODBUS, Free contact card (RS232 e SNMP optional)

DISPLAY Touch screen+LED

ALARMS Low batteries, Anormal input, Overload, Block/Fault ecc.

PROTECTION Low batteries, Overload, Short-circuit, Over-temperature ecc.

NOISE (DB) <55

TEMPERATURE (°C) -5~40

HUMIDITY 0~95%

DIMENSIONS (L×W×H) (MM) 250×755x880 300x785x1250


132 with batteries - 140 with batteries -
WEIGHT (KG) 270 with batteries - 85 without
50 without 50 without

CERTIFICATIONS

STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


UPS SERIES IST 7

Power from 60kVA to 200kVA

3:1 3:3

UPS THREE-PHASE WITH EXPANDABLE MODULAR STRUCTURE


The IST7 three-phase UPS (60-200kVA) are AEC’s range of three-phase expandable
online UPS, double conversion tower UPS in powers starting from 60kVA up to 200kVA.
The UPS IST7 series uses a centralized modular design, allowing future expansion of
the UPS.

IST7 UPSs are available in three sizes, fixed power 60kVA, from 80 to 120kVA and
from 160kVA to 200kVA. Thanks to the inverter’s 3 IGBT levels, the UPS guarantee
efficiency up to 97% and a unitary output power factor. They are directly configurable
from the display, with ample flexibility in the number of batteries and high overload
capacity. The innovative self-cleaning function reduces the risk of dust accumulation
on the boards. The system includes the free contact card for alarms.

UPS THREE-PHASE EXPANDABLE


UPS Three-phase 43

PRINCIPAL FEATURES
EFFICIENT AND EXPANDABLE
• Output power factor equal to 1; • Innovative three-level IGBT technology integrated in the
inverter section;
• Maximum AC \ AC efficiency up to 97%;
100%
• Expandable in power directly on site and from the
display;
98%

• Shared batteries for parallel systems, a single battery


95% pack for two N + 1 UPS;
UPS 1 UPS 2
93%

90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

ECO Efficiency
AC/AC Efficiency

MODULAR STRUCTURE Common battery pack

• Battery Configurations:
from 28 to 48 monoblocks (±168~±288Vcc);
1
• ECO mode with efficiency up to 99%, configurable from
2
the display;
1
2
• Possibility of parallel installation (redundant or power)
3 up to 1.6MW;

• Advanced control with double redundant DSP;


3
DSP DSP

• Fully tropicalized electronic cards;


60-120KVA 160-200KVA
• Display available in 7 languages;

1 Power unit capacity 60kW | 80-120kW | 160-200kW • Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
improve their efficiency.
2 Bypass and control unit including RS485, Modbus and
programmable dry contact

3 Power distribution unit with terminal block:


Input, Output, Bypass and Battery
Automatic fan control
COMPUTERIZED MONITOR TOUCH-SREEN
IST7 IST7
60-80-100-120KVA 160-200KVA

Display 4.3" Inches


Display 7" Inches

SETTINGS FROM DISPLAY


• Access to the menu via different password levels (User,
Technician and Manufacturer);

• Configuration for input, output, bypass, batteries,


communications, language and operating modes;

• Periodic self-cleaning function, to expel impurities and


reduce the risk of breakdowns;

• Large memory up to 10,000 events downloadable via the


USB port integrated in the UPS;

• Advanced communication for installation and operation


with diesel generators;

• Alarms from clean contact card, configurable from


display;

• Periodic graphic recording of inverter, rectifier and


control waveforms.

TOUCH-SCREEN DISPLAY WITH LED COLORED BAR

Normal Mode Bypass Mode Warning Mode


45

SMART-SLEEP PARALLEL INTELLIGENCE


100%

30% load
98%
95%
efficiency

95%

60% load
93%

96.5%
efficiency
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Intelligent Sleep Mode

W-ECO Efficiency
ECO Efficiency
AC/AC Efficiency

OPERATING MODES
Static Bypass Static Bypass

Rectifier Inverter Rectifier Inverter


Load Load

Battery Battery

Double Conversion Mode ECO Mode

Static Bypass Static Bypass

Rectifier Inverter Rectifier Inverter


Load Main

Battery Battery

W-ECO Mode Self-load Test Mode

FREQUENCY CONVERTER
50HZ 60HZ
• 50Hz-60Hz or 60Hz-50Hz converter mode;

60HZ 50HZ
• Possibility of disabling the static bypass and the DC
power supply of the inverter. Frequency Converter Mode

STANDARD AND COMMUNICATIONS


• Clean contact card with 5 alarms; • Integrated RS485 and Modbus communication port;

• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;

• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);

• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
EXCELLENT PERFORMANCE
• Efficiency higher than 95% even at low loads; • Advanced 3-stage battery charging and maintenance
system;
• Maximum output tolerance, ability to operate with 100%
unbalanced loads;

• Double input with wide tolerance, compatible with diesel


generators ;
3 charging stages
+25%

• Redundant and hot extractable power modules (rectifier


and inverter);
- 60%

• Centralized bypass module with battery start button;

Three-phase power supply range

MORE OPTIONS
• Flexible Network Management: SNMP
• Expanded dry contact kit (4 in 4 out)
• BMS kit for lithium battery communication
• Intelligent Battery Monitoring System
• Battery tripping kit
• N+X in parallel
• Input and output isolation transformer
• SPD: C Grade
• Battery Charge Temperature Compensation

ECONOMIC SAVING
Let’s take an example on a 120kVA AEC UPS working at full load H24 with average efficiency of 96% and a unit output power
factor, comparing it with a typical UPS with standard efficiency 93% and output power factor = 0.9:

• Daily savings:
(120kVA*1*96% - 120kVA*0.9*93%)*24 hours= 354.24 kWh;

• Daily financial savings:


354.24 kWh*0.15€/kWh = 53.1€;

• Annual saving: 354.24 kWh*365 days = 129.297,6 kWh;

• Annual Financial saving: 129.297,6 kWh*0.15€ = 19.395 € each year


UPS Three-phase 47

TECHNICAL SPECIFICATIONS
MODELS IST7-60 IST7-80 IST7-100 IST7-120 IST7-160 IST7--200
INPUT
VOLTAGE (VAC) 380/400/415 (138~485 L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) +20% (-10/-15/-30 selectable) /+15% (10/20/25 selectable)
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3+N+PE
OUTPUT
POWER (kW) 60 80 100 120 160 200
POWER FACTOR 1
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD 3+N+PE
VOLTAGE STABILIZATION THDv<1% at linear load, THDv<3% at non-linear load
WAVEFORM Pure sine wave
EFFICIENCY 97%
≤130%: long run;
OVERLOAD
130%< load ≤150%: 5min; 150%< load ≤200%: 1s; 200%< load≤300%: 100ms; >300%: immediately.
BATTERIES
BATTERIES VOLTAGE (VDC) ±168 ~±288 adjustable
STANDARD BATTERY CONFIGURATION External
MAX. CHARGING CURRENT (A) 30 60
OTHER SPECIFICATIONS
COMMUNICATIONS RS485, MODBUS, Free Contact Card ( SNMP optional)
DISPLAY Touch screen+LED
ALARMS Low batteries, Anormal input, Overload, Block/Fault ecc.
PROTECTION Low batteries, Overload, Short-circuit, Over-temperature ecc.
NOISE (DB) <65
TEMPERATURE (°C) 0~40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 400×960×1200 600×1000×1600
WEIGHT (KG) 145 161 171 312 320

CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


UPS SERIES IST 7T

Power from 80kVA to 600kVA

UPS THREE-PHASE WITH INTEGRATED TRANSFORMER


The IST7 T Transformer based UPS (80-600kVA) are AEC’s range of three-phase
transformer integrated online UPS, double conversion tower UPS in powers starting
from 80kVA up to 600kVA. The UPS IST7 series uses a isolation transformer on
inverter output, ensuring maximum reliability.
IST7 T UPSs are available in different powers 80kVA, 100kVA, 120kVA, 160kVA, 200kVA,
250kVA, 300kVA, 400kVA, 500kVA, 600kVA. Thanks to the inverter’s 3 IGBT levels,
the UPS guarantee efficiency up to 94% and a output power factor equal to 0.9 They
are directly configurable from the display, with ample flexibility in the number of
batteries and high overload capacity. The innovative self-cleaning function reduces
the risk of dust accumulation on the boards. The system includes the free contact card
for alarms.

UPS TRANSFORMER BASED


UPS Transformer based 49

PRINCIPAL FEATURES
EFFICIENT AND RELIABLE
• Output power factor = 0.9;
• Advanced control with double redundant DSP;
• Maximum AC \ AC efficiency up to 94%;
DSP DSP
100%

98% • Fully tropicalized electronic cards;

95% • Display available in 7 languages;

93%
• Intelligent fans with high efficiency cooling, multiple
modes to control their speed, extend their life and
90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
improve their efficiency.

ECO Efficiency
AC/AC Efficiency

• The output isolation transformer provides high reliability Automatic fan control
to adapt different harsh industrial environments and
protects the critial loads.

SETTINGS FROM DISPLAY


• Access to the menu via different password levels (User,
Technician and Manufacturer);

• Configuration for input, output, bypass, batteries,


communications, language and operating modes;

• Periodic self-cleaning function, to expel impurities and


reduce the risk of breakdowns;

• Large memory up to 10,000 events downloadable via the


USB port integrated in the UPS;

• Advanced communication for installation and operation


with diesel generators;

• Alarms from clean contact card, configurable from


display;

• Periodic graphic recording of inverter, rectifier and


control waveforms.
POWER CAPACITY TRANSFORMER SYSTEM
IST7-T IST7-T IST7-T
80KVA 100-120-160KVA 200-250KVA

ADVANCE DESIGN AND TECHNOLOGY


IST7-T
300-400KVA
• 100% 3-phase unbalance load adapt to different kinds of
complex applications;

• Dual airducts design of fer good cooling to protect the


key components and extend the service life;

• Dual power supply redundancy;

• Wide input voltage range provides high adaptability to


the grid and extend the battery service life;

• Main PCB board with professional electromagnetic


shielding improve reliable porformance of EMC;

• ECO-mode (98% Efficiency) gives possibility of significant


cost reduction and heat emission;

• Bus synchronization control function provides reliable


high power for the dual bus application;

• Advanced no-master-slave parallel technology achieves


online power expansion and prevent single fault.
UPS Transformer based 51

IST7-T
500-600KVA

FLEXIBLE, DURABLE AND POWERFULL


• Common battery bank sharing in parallel system (optional);
+25%

• 3-stage battery charging mode;

- 25%
• Self-load test function without load enables onsite
commission (optional);

Three-phase power range • Common bypass cabinet (optional);

• Support parallel mode up to 4.8MVA.

STANDARD AND COMMUNICATIONS


• Clean contact card with 5 alarms; • Integrated RS485 and Modbus communication port;

• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;

• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);

• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
TECHNICAL SPECIFICATIONS
MODELS IST7T-80 IST7T-100 IST7T-120 IST7T-160
INPUT
VOLTAGE (VAC) 380/400/415
TENSION TOLERANCES (VAC) 380/400/415±25%
FREQUENCY INPUT (HZ) 40-70
BYPASS TENSION (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) 348 (360 setting)
CHARGING CURRENT (A) 10~40A setting
OUTPUT
POWER (kW) 80 100 120 160
POWER FACTOR 0.9 (1.0 optional)
PHASES 3+N+PE
WAVEFORM Sinusoidal
TENSION (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2%, allow 100% unbalance
THD THD≤2% (linear load)
MAX. SYSTEM EFFICIENCY 94%
PARALLEL up to 8 units
OVERLOAD 125% load for 10mins, 150% load for 1 min
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Dry Contact Card (SNMP optional)
NOISE (DB) < 65
DIMENSIONS (L×W×H) (MM) 500x800x1600 700×800×1800
WEIGHT (KG) 520 600 650 825
CERTIFICATIONS
MARKING CE
STANDARDS IEC EN 62040-1, IEC EN 62040-2, IEC EN 62040-3

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
UPS Transformer based 53

TECHNICAL SPECIFICATIONS
MODELS IST7T-200 IST7T-250 IST7T-300 IST7T-400 IST7T-500 IST7T-600
INPUT
VOLTAGE (VAC) 380/400/415
VOLTAGE TOLERANCES (VAC) 380/400/415±25%
FREQUENCY INPUT (HZ) 40-70
BYPASS VOLTAGE (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) 384 (348/360/372 setting)
CHARGING CURRENT (A) 10-100A setting
OUTPUT
POWER (kW) 200 250 300 400 500 600
POWER FACTOR 0.9 (1.0 optional)
PHASES 3+N+PE
WAVEFORM Sinusoidal
VOLTAGE (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2%, allow 100% unbalance
THD ≤1% (linear loads at full load), ≤4% (non-linear loads at full load)
MAX. SYSTEM EFFICIENCY 94%
PARALLEL up to 8 units
OVERLOAD 125% load for 10mins, 150% load for 1 min
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Free contact card (SNMP optional)
NOISE (DB) <70
DIMENSIONS (L×W×H) (MM) 1400x1000x1850 1600×1000×1850 3000×1000×1850
WEIGHT (KG) 1280 1568 1830 2050 4500
CERTIFICATIONS
MARKING CE
STANDARDS IEC EN 62040-1, IEC EN 62040-2, IEC EN 62040-3

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


UPS SERIES IST 6

Power from 30kVA to 1.2MVA

3:3

MODULAR UPS HOT-SWAPPABLE


The IST6 modular UPS (30-1200kVA) are AEC’s range of three-phase modular UPS,
UPS with hot-swappable modules, in powers starting from 30kVA up to 1200kVA
in single structure. The UPS IST6 series adopts a completely modular technology,
guaranteeing constant redundancy of the continuity system.

Their modularity allows future expansion in power up to 4.8MW. They are available in
four sizes, up to 120kVA | 200kVA - 300kVA | 600kVA- 800kVA | 1000kVA-1200kVA |
with an efficiency of up to 97% and maximum safety. IST6 is designed for medium and
large data centers. UPS configurable directly from the display, with great flexibility and
high overload capacity. The self-cleaning function reduces the risk of dust accumulation
on the cards. The system includes the free contact card for alarms.

UPS MODULAR
UPS Modular 55

PRINCIPAL FEATURES
MODULAR TECHNOLOGY HOT-SWAPPABLE
• Output power factor equal to 1;

• Maximum AC \ AC efficiency up to 97%


ECO-Mode up to 99%
Online ECO-Mode up to 98%;
100%

98%

95%

93%

90%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%

On-ECO Efficiency
ECO Efficiency
AC/AC Efficiency

MAXIMUM SCALABILITY
• Innovative modular N + 1 technology in all components
of the UPS system;

• Expandable and hot potential directly on site and from • Battery configurations:
the display; from 15 to 20 monoblocks (± 180 ~ ± 240Vdc);

• Possibility of installation in a single structure up to • ECO mode with efficiency up to 99%, configurable from
1200kW with 12 modules of 100kW; the display;

• Possibility of parallel installation (redundant or power) • Advanced control with double redundant DSP;
up to 5MW;
DSP DSP

• Batteries in common for systems in parallel, a single


battery pack for two UPS N + 1; • Completely tropicalized electronic cards;
UPS 1 UPS 2
• Display available in 7 languages;

• Intelligent fans with high efficiency cooling, multiple


modes to control their speed, extend their life and
improve their efficiency.

Automatic fan control

Share battery pack


REDUNDANT AND HOT-SWAPPABLE POWER MODULES

• Hot-swappable N + 1 UPS module with power of 30kW


for structure up to 120kW;

• Hot-swappable N + 1 UPS module with power of 50kW


for structures with maximum expansion up to 200kW,
300kW and 600kW;

• Hot-swappable N + 1 UPS module with 100kW power


for structures with maximum expansion up to 800kW,
1000kW and 1200kW;

• UPS module including rectifier and inverter with 3-level


IGBT technology and redundant components;

• Redundant modules in power and in parallel N + 1 for


maximum reliability and versatility;

• Intelligent saving modes with modules automatically


activated periodically only in case of energy need.

STRONG, FLEXIBLE AND FUTURE EXPANDABLE STRUCTURES

120kW 200-300kW 600-800kW 1000-1200kW


UPS Modular 57

SETTINGS FROM DISPLAY

• Access to the menu via different password levels (User,


Technician and Manufacturer);

• Configuration for input, output, bypass, batteries,


communications, language and operating modes;

• Periodic self-cleaning function, to expel impurities and


reduce the risk of breakdowns;

• Large memory up to 10,000 events downloadable via the


USB port integrated in the UPS;

• Advanced communication for installation and operation


with diesel generators;

• Alarms from clean contact card, configurable from


display;

Display 4.9" Inches

EXCELLENT PERFORMANCE
• Advanced 3-stage battery charging and maintenance
• Efficiency higher than 95% even at low loads;
system;

• Maximum output tolerance, ability to operate with 100%


unbalanced loads;

• Double input with wide tolerance, compatible with diesel


generators;
3 charging stages

+25%
• Redundant and hot extractable power modules (rectifier
and inverter);
- 60%

• Centralized bypass module with battery start button;

Three-phase power supply range


FREQUENCY CONVERTER

• 50Hz-60Hz or 60Hz-50Hz converter mode; 50HZ 60HZ

• Possibility of disabling the static bypass and the DC 60HZ 50HZ


power supply of the inverter.
Frequency converter mode

AEC APP FOR MOBILE


• Download the AEC UPS Italy APP and start monitoring
and controlling your Modular UPS wherever you are,
directly from your smartphone thanks to the AEC SNMP
API communication card;

• Possibility of integration with BMS and remote


monitoring and control systems of Data-Centers and
technological structures with Modbus protocol and API.

OPERATING MODES
Static Bypass Static Bypass

Rectifier Inverter Rectifier Inverter


Load Load

Batteries Batteries
Online Double Conversion ECO Mode
Static Bypass Static Bypass

Rectifier Inverter
Rectifier Inverter
Load

Batteries Batteries

OnLine-ECO Mode Self-loading test Mode

STANDARD AND COMMUNICATIONS


• Clean contact card with 5 alarms; • Integrated RS485 and Modbus communication port;

• Bypass switch for maintenance; • Protection against reverse polarity of the batteries;

• EPO emergency release button on the front, remote • SNMP network card for remote control and monitoring
clean contact on the back; (optional);

• Starting from battery by means of a specific button; • NC \ NO dry contact card for further 12 alarms
(optional).
UPS Modular 59

TECHNICAL SPECIFICATIONS

MODELS IST6-120 IST6-200 | IST6-300 IST6-600


POWER MODULES IST6-30-J IST6-50-J
INPUT
VOLTAGE (VAC) 380/400/415
TENSION TOLERANCES (VAC) L:L 138~485
FREQUENCY INPUT (HZ) 40-70
BYPASS TENSION (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) ±192 (±180~ ±276 settable)
CHARGING CURRENT (A) N×10 Maximum (N: number of power modules)
OUTPUT
POWER (kW) 120 200 | 300 600
POWER FACTOR 1
PHASES 3+N+PE
WAVEFORM Sinusoidal
TENSION (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2 degrees
THD ≤1% (Linear loads at full load), ≤4% (Non-Linear loads at full load)
MAX. SYSTEM EFFICIENCY 97%
PARALLEL N+1 redundant
105-115% Overload for 60mins, 116%-130% Overload for 10mins,
OVERLOAD
131%-150% Overload for 1 min, more than 150% Load transfers on Bypass
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Free Contact Card (SNMP optional)
NOISE (DB) < 65 <70
POWER MODULE (KVA) 30 50
WEIGHT POWER MODULE (KG) 32 33
DIMENSIONS (L×W×H) (MM) 600×860×2000 1200×860×2000
UPS 180 224 427
WEIGHT (KG) Bypass Module 17 25 27
Power Module 30/50kW 27 33
CERTIFICATIONS
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
TECHNICAL SPECIFICATIONS

MODELS IST6-800 IST6-1000 IST6-1200


POWER MODULES IST6-100-J
INPUT
VOLTAGE (VAC) 380/400/415
VOLTAGE TOLERANCES (VAC) L:L 138~485
FREQUENCY INPUT (HZ) 40-70
BYPASS VOLTAGE (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) ±240 (±180~ ±276 settable)
CHARGING CURRENT (A) N×10 Maximum (N: number of power modules)
OUTPUT
POWER (kW) 800 1000 1200
POWER FACTOR 1
PHASES 3+N+PE
WAVEFORM Sinusoidal
VOLTAGE (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2 degrees
THD ≤1% (linear loads at full load), ≤4% (non-linear loads at full load)
MAX. SYSTEM EFFICIENCY over 97%
PARALLEL N+1 ridondant
105-115% Overload for 60mins, 116%-130% Overload for 10mins,
OVERLOAD
131%-150% Overload for 1 min, more than 150% Load tranfers on Bypass
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Free contact card (SNMP optional)
NOISE (DB) <70
POWER MODULE (KVA) 100
POWER MODULE WEIGHT (KG) 33

DIMENSIONS (L×W×H) (MM) 1400*1000*2000 1800*1000*2000

UPS 580 650 740

WEIGHT (KG) Bypass Module 60 80 80


55
Power Module 100kW

CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
61

REDUNDANT MODULAR TECHNOLOGY ...

Thanks to the support of qualified and professional technicians, AEC is


able to assist and guide its customers in choosing the most suitable
solution for them.

Nowadays the use of data centers in the productive world is growing dramatically as they are of fundamental
importance to support the continuous technological development of our planet. If until a few decades ago the
interruption of the operation of a data center would not have caused great inconvenience, today we must always
remain vigilant and ready to intervene in the event of system failure.

For this reason, UPS uninterruptible power supplies are an indispensable element for the correct and continuous
operation of data centers and there are several factors to consider when evaluating the type of UPS to install.
LITHIUM SYSTEM L6

Power 40Ah 50Ah 100Ah

LITHIUM-ION BATTERY SYSTEM


“Carbon Peaking • Carbon Neutrality” has become a global priority for all countries
and industries, and the concept of green energy saving has also been widely recognized
by the people. Thanks to the new infrastructure and ‘dual carbon’ goals, the lithium-ion
battery industry has developed geometrically at an astonishing pace. Lithium-ion iron
phosphate walks in the forefront for its safety and stability, and has constantly carried
out security upgrades.

By following the nuclear-grade safety design concept and leveraging its over 30
years of professional experience in the power field, Allis Electric deeply applied power
electronics to the lithium-ion battery technology and released lithium-ion battery
solution with high safety and reliability - AEC L6 Smart Backup Lithium-ion Battery
System Solution.

LITHIUM SYSTEM
63

ADVANCED LITHIUM-ION TECHNOLOGY


• Life cycles: Li-ion batteries have a cycle longer life
than lead-acid batteries, i.e can be downloaded and
reloaded for a greater number of times before losing
their capacity.

• Self-discharge: Li-ion batteries have a self-discharge


lower than lead-acid batteries, which meaning they lose
less energy when not in use.

• Working voltage: Li-ion batteries have a higher


working voltage than al batteries lead, which means
they can deliver more energy for each unit of volume.

• Working temperature: lithium ion batteries they can


work in a wider range of temperatures compared to
lead-acid batteries.

L6 Smart Backup Lithium-ion Battery


System Solution

PRODUCT STRUCTURE

Power distribution switch

SBMU

Touch screen (MBMU)

40Ah/50Ah battery pack

100Ah battery pack

40Ah/50Ah lithium-ion battery system cabinet 100Ah lithium-ion battery system cabinet

AEC L6 Smart Backup Lithium-ion Battery System Solution


MAIN FEATURES
The L6 smart backup lithium-ion battery system solution adopts the modular parallel design, Safe, smart and simple,
which can compatible with the full range of AEC UPS, with power ranging from 60kW to 1200kW.

Safe and reliable


Electrical and physical double isolation
• Reduces the fault scope to an effective space without diffusion
• Port zero voltage, no risk of short circuit shock
Two-level fire linkage
• Module fire protection
• Can quickly, accurately and effectively detect and extinguish the
fire source will extinguish the fire in the initial stage.
Concerted operation with modular
parallels
Failure module exit automatically
• Modular parallel design, failure module exit automatically, will not
affect the system. Other modules can work normally.

Smart and Intelligent technology


Module design, plug and play
• 5mins maintenance, reduce the OPEX cost
Flexible for expansion
• Module design, can expand the capacity of modules or cabinets.

Module-level expansion with • Reduce the CAPEX cost


fine granularity Smart battery test
• Parallel design, the battery can test the capacity Separately. No need
to cut off the power supply, improve the reliability

Easy and simple to operate


Intelligent current equalization
Phase I Phase II Phase III

• Can be used with new and old batteries


old battery old battery new battery
SOH=88% SOH=91% SOH=95%

• Can be used with lithium-ion batteries from different suppliers


Intelligent voltage equalization
• Intelligent voltage equalization module, no barrel effect
• Prolong the backup time, improve battery utilization
Fault recording, early warning
• Fault recording, early warning, accurate and quick fault location, reduce
the OPEX cost More flexible mixing of old and
Adaptive SOC management new batteries

• Intelligent charge and discharge management, avoid over charge and


over discharge
• Detects the battery internal temperature. Improve the safety and reduce
the OPEX cost
65

THREE-LAYER BMS ARCHITECTURE


The adopted three-layer BMS architecture (PBMU/SBMU/MBMU) ensures the reliability of lithium-ion battery system
from cell, module and system layers.

SYSTEM ARCHITECTURE

RS485 TCP/IP

NetEco

Network management server

Layer III
UPS
MBMU
unit

CAN CAN

SBMU SBMU

CAN CAN CAN CAN

Battery module (Built-in PBMU) Battery module (Built-in PBMU)


BATTERY CONFIGURATION TABLE

1. 40Ah battery module for short time power backup


Meeting the required backup time according to the initial capacity

UPS capacity (kW) 12min (initial) 25min (initial)


Cabinet Battery module Cabinet Battery module
≤60 1 6 1 12
≤80 1 8 1 16
≤100 1 10 1 20
≤200 1 20 2 40
≤300 2 30 3 60
≤400 2 40 4 80
≤500 3 50 5 100
≤600 3 60 6 120
≤800 4 80 8 160
Remark: This configuration is calculated with theoretical values, and the actual
configuration needs 10% margin: Actual backup time = theoretical backup time * 0.9

2. 50Ah battery module for short time power backup


Meeting the required backup time according to the initial capacity

UPS capacity (kW) 15min (initial) 30min (initial)


Cabinet Battery module Cabinet Battery module
≤60 1 6 1 12
≤80 1 8 1 16
≤100 1 10 1 20
≤200 1 20 2 40
≤300 2 30 3 60
≤400 2 40 4 80
≤500 3 50 5 100
≤600 3 60 6 120
≤800 4 80 8 160
Remark: This configuration is calculated with theoretical values, and the actual
configuration needs 10% margin: Actual backup time = theoretical backup time * 0.9

3. 100Ah battery module for long time power backup


Meeting the required backup time according to the initial capacity

UPS capacity (kW) 1h (initial) 2h (initial) 4h (initial)


Cabinet Battery module Cabinet Battery module Cabinet Battery module
≤6 1 1 1 2 1 4
≤10 1 2 1 4 1 8
≤15 1 3 1 6 2 12
≤20 1 4 1 8 2 16
≤40 1 8 2 16 / /
Remark: This configuration is calculated with theoretical values, and the actual
configuration needs 10% margin: Actual backup time = theoretical backup time * 0.9
67

TECHNICAL PARAMETERS

BATTERY CELL 40AH 50AH 100AH

TYPE LFP

DIMENSIONS (MM) 27.0×148.5×133.0 50.5×160.3×120.0

WEIGHT (KG) 1.01±0.1 1.11±0.1 1.95±0.1

RATED CAPACITY (AH) 40 50 100

DISCHARGE RATE (C) 6 4 1

CHARGE RATE (C) 1 1 0.5

RATED VOLTAGE (V) 3.2

CYCLE LIFE 5,000 TIMES (@50% DOD)

BATTERY PACK L640-6C-240-X L650-4C-240-X L6100-1C-240-X

BATTERY RATED VOLTAGE (V) 57.6

BATTERY CAPACITY (AH) 40 50 100

MAX. ENERGY (KWH) 2.3 2.85 5.7

DC/DC RATED OUTPUT VOLTAGE (V) 240*2 (IN SERIES OR PARALLEL)

DC/DC RATED OUTPUT POWER (KW) 10 5

DIMENSIONS (W*D*H) (MM) 223×665×153 440×665×132

WEIGHT (KG) 36±2 38±2 50±2

BATTERY CABINET L640-6C-20-MX L650-4C-20-MX L6100-1C-10-MX

BATTERY MAX ENERGY (KWH) 46 58 69

RATED OUTPUT VOLTAGE (V) 240/±240/480

SYSTEM RATED OUTPUT POWER (KW) 200 60

NUMBER OF BATTERY MODULES 20 12

CURRENT-UNBALANCE ≤5%

SOC ACCURACY ≥95%

COMMUNICATION RS485, CAN, TCP/IP AND DRY CONTACT

WORKING TEMPERATURE (°C) 0~40 (+15~+30 RECOMMENDED)

ALTITUDE (M) 0~4000M, ABOVE 2000M DERATE

DIMENSIONS (W*D*H) (MM) 600×860×2000

WEIGHT (KG) 960±10 1000±10 860±10

MAXIMUM PARALLELED CABINETS 8

OPTIONAL DISTRIBUTION CABINET, FIRE EDGE CABINET, IT REAR FRAME

SELF-DISCHARGE RATE ≤3% (0-30°C/1 MONTH)


CENTRAL POWER SUPPLY SYSTEM
CPSS EN50171
CENTRAL POWER SUPPLY SYSTEM

The CPSS - Central Power Supply System, has


been designed to provide lighting in the event
of a power failure. A CPSS must comply with
the EN 50171 standard for the protection of the
power supply of emergency and safety systems.

The CPSS is a centralized power supply system designed specifically to be installed in


emergency lighting systems and other emergency systems such as automatic firefighting
systems, alarms, fume extraction equipment, carbon monoxide detection systems.

The EN 50171 standard provides for the obligation to install CPSS in crowded areas and in
public places such as hospitals, schools, museums, cinemas, etc. to provide lighting in the
event of a blackout.

DIFFERENCE BETWEEN UPS AND CPSS


Many people still confuse between UPS and CPSS and do not have a clear idea of ​​
what their characteristics and functions are. Both are used to make up for a lack of
electricity but are applied in different contexts. Let’s do some clarity and outline the
differences between a UPS and a CPSS.

Central Power Supply Systems (CPSS) and Uninterruptible Power Supply Systems
(UPS) have many similarities. As already explained, both products provide electricity
in the event of a blackout or network failure, but it is essential to know that
these two systems are used in different contexts and for this reason they are not
interchangeable.

Although CPSS and UPS have the same components, the former are designed
according to regulatory standards that guarantee maximum product safety to be
applied to safety systems and must comply with all the requirements of the EN
50171 standard.

In fact, the CPSS are used in the event of a power failure during an emergency and
danger situation, such as a fire or an earthquake and, especially on these occasions,
it is essential to have a lighting system that allows people to immediately identify
the ways of exodus, especially in public places subject to crowding and in the
workplace.

CPSS EN 50171
69

EN 50171 COMPLIANT

The EN 50171 standard applies to systems permanently connected to AC power supply voltages not exceeding 1000 V
and which use batteries as an alternative energy source. The structure of the CPSS must also comply with the CEI EN
62040 standard.

The EN 50171 standard lists the technical characteristics that the CPSS must possess in order to be compliant.

FEATURES:

• Batteries:
The batteries used in the CPSS must have an expected life of at least 10-12 years;

• Overload:
The inverters used in the CPSS must be able to handle a constant overload of 120%;

• Charging Time:
The chargers used must recharge the batteries within 12 hours, starting from a low battery condition;

• Casing Resistence:
The casing of the CPSS must have excellent mechanical strength, capable of resisting heat and fire.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


SERIES CPSS 7

Power from 10kVA to 40kVA

DETAILS:
• Constant overload of 120%;
• Batteries 10-12 years expected life;
• Charging time of less than 12 hours;
• Structure compliant with CEI EN 62040.

CENTRAL POWER SUPPLY SYSTEM | CPSS7


The CPSS7 (10-40kVA) is one of the static CPSS. The CPSS 7 utilize advanced
3-level inverter technology and digital technology for complete interconnection,
offering benefits such as high efficiency and high power density, while only taking
up a small amount of floor space.
AEC’s CPSS provide safe, stable, clean and ecological energy to loads and are
considered ideal for providing completely safe and reliable protection, particularly
suitable for emergency lighting systems.

CPSS EN 50171
CPSS EN-50171 71

TECHNICAL SPECIFICATIONS

MODELS CPSS7-10 CPSS7-20 CPSS7-30 CPSS7-40

INPUT
VOLTAGE (VAC) 80-280 (L-N) / 138-485 (L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3:3 / 3:1 / 1 : 1
OUTPUT
POWER (kW) 8 16 24 32
POWER FACTOR 0.8
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD THD<1% (linear loads), THD <3% (non-linear loads)
WAVEFORM Sinusoidal pure, THD<1% linear
EFFICIENCY 96%
OVERLOAD Constant up to 120%
BATTERIES
BATTERIES VOLTAGE (VDC) ±96~±240 configurable ±144~±240 configurable ±144~±240 configurable ±144~±240 configurable
MAX. CHARGING CURRENT (A) 1-10 / 1-20 (configurable)
BATTERY LIFE 10 - 12 years
OTHER SPECIFICATIONS
CHARGING TIME < 12 hours
COMPLIANCE Structure in compliance with CEI EN 62040
NOISE (DB) < 65
TEMPERATURE (°C) 0 ~ 40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 250×755x880 300x785x1250
WEIGHT (KG) 143 240
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3), EN50171

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


SERIES CPSS 7

Power from 60kVA up to 200kVA

DETAILS:
• Constant overload of 120%;
• Batteries 10-12 years expected life;
• Charging time of less than 12 hours;
• Structure compliant with CEI EN 62040.

CENTRAL POWER SUPPLY SYSTEM | CPSS7


The CPSS7 (60-200kVA) utilize advanced 3-level inverter technology and digital
technology for complete interconnection, offering benefits such as high efficiency
and high power density, while only taking up a small amount of floor space.
AEC’s CPSS provide safe, stable, clean and ecological energy to loads and are
considered ideal for providing completely safe and reliable protection, particularly
suitable for emergency lighting systems.

CPSS EN 50171
CPSS EN-50171 73

TECHNICAL SPECIFICATIONS

MODELS CPSS7-60 CPSS7-80 CPSS7-100 CPSS7-120 CPSS7-160 CPSS7-200

INPUT
VOLTAGE (VAC) 380/400/415 (138~485 L-L)
FREQUENCY (HZ) 40~70
BYPASS VOLTAGE (VAC) 380/400/415: -20%~+15%
POWER FACTOR ≥0.99
THDI ≤3%
PHASES 3-4W+PE
OUTPUT
POWER (kW) 48 64 80 96 128 160
POWER FACTOR 0.8
VOLTAGE (VAC) L-N: 220/230/240±1% L-L: 380/400/415±1%
FREQUENCY (HZ) 50/60±0.1
THD 3-4W+PE
WAVEFORM Pure Sinusoidal , THD<1% linear
EFFICIENCY 96%
OVERLOAD Constant at 120%
BATTERIES
BATTERIES VOLTAGE (VDC) ±168 ~±288 adjustable
STANDARD BATTERY
External
CONFIGURATION
MAX. CHARGING CURRENT (A) 1-30 1-40
BATTERY LIFE 10 - 12 years
OTHER SPECIFICATIONS
CHARGING TIME < 12 hours
COMPLIANCE Structure in compliance with CEI EN 62040
NOISE (DB) <65
TEMPERATURE (°C) 0~40
HUMIDITY 0~95%
DIMENSIONS (L×W×H) (MM) 450x840x1400 600x900x1600

WEIGHT (KG) 180 210 242 320 350

STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3), EN50171

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


BATTERY CABINET FOR UPS
STEEL BATTERY CABINETS
The battery cabinet for UPS is an accessory designed to extend the autonomy of the UPS. Each UPS has its
own external battery cabinet and the number of batteries varies according to the UPS model to which it
will be connected.

AEC is able to offer its customers a tested and solid cabinet housing system for accumulators designed to
ensure continuity of power supply for UPS of any size.

The AEC Battery Cabinets are easily customizable and adaptable to


projects of different nature. Our carpentry is able to offer battery
cabinets with protection degree up to IP44, various aluminum alloys
or stainless steel and with a wide range of accessories for internal
ventilation such as automatic fans, IP68 with 12V or 24V direct
current power supply.

Wide choice of fuse holders or robust bipolar or tripolar


disconnectors with a maximum capacity of 1000A.
75

BATTERY CABINETS for single-phase tower UPS


BB1

Battery cabinet for IST3 1-2-3kVA UPS


Standard 36Vcc with possibility of modification to 24-72Vcc;

BB2

Battery cabinet for IST3 1-2-3kVA UPS


Standard 72Vcc with possibility of modification to 24-36-48-72-96Vcc;

BB3

Battery cabinet for IST3 1-2-3-6-10kVA UPS


Standard 192Vcc with possibility of modification to 24-36-48-72-96Vcc;

BATTERY CABINETS for single-phase rack 19” UPS

BBJ

Battery cabinet for rack IST3J 1-2-3-6-10kVA UPS


Standard 96Vcc with possibility of modification to 24-36-48-72-96Vcc;

BBJ2

Battery cabinet for IST3J e IST9 UPS


Standard 192Vcc with possibility of modification to 24-36-48-72-96Vcc;
BATTERY CABINET BB4

GENERAL CHARACTERISTICS
DIMENSIONS : 255 x 755 x 900mm

BATTERY VRLA 12V : 9Ah

2 or 3 POLES DC FUSES: 32A-63A

BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 16 up to 80 battery 12V 9Ah

UPS 3-POLES (POSITIVE - NEUTRAL - NEGATIVE) :


From 16 up to 80 battery 12V 9Ah

BATTERY CABINET
Battery Cabinet 77

Three-poles DC breaker 63A

Terminal cover
Optional 2 Breaker

Terminal Block

Ground

Wheels

4 Battery Layers max 20 pcs


Total max 80 pcs VRLA 12V 9Ah

DC Fuse protection board

BATTERY CABINET
MODELS BB4
TECHNICAL SPECIFICATIONS
DIMENSIONS 255 x 755 x 900 mm
WEIGHT (EMPTY) 40 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 80 x 12V 9Ah
IP PROTECTION IP 20
DC FUSES 32A - 63A
CABLE ENTRANCE BACK/REAR
COLOUR RAL9005

UPS POWER COMPATIBILITY from 1 to 40kVA


STANDARDS
CE - EC IEC-EN 62040-1

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB5

GENERAL CHARACTERISTICS
DIMENSIONS : 460 x 800 x 1400mm

BATTERY VRLA 12V : 9Ah-24Ah-40Ah

2 or 3 POLES DC FUSES: 32A-63A-100A-125A

BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 82 up to 128 battery 12V 9Ah
From 16 up to 38 battery 12V 24-26Ah
From 16 up to 38 battery 12V 40Ah

UPS 3-POLES (POSITIVE - NEUTRAL - NEGATIVE) :


From 82 up to 128 battery 12V 9Ah
From 16 up to 38 battery 12V 24-26Ah
From 16 up to 38 battery 12V 40Ah

BATTERY CABINET
Battery Cabinet 79

Three-poles DC Fuses Max 125A


Top cable entrance
Bottom cable entrance

4-5 Battery Shelves


Battery VRLA 12V 9Ah - 26Ah - 40Ah
Max 30 x 12V 9Ah x shelf
or max 8 x 12V 26/40Ah x shelf

BATTERY CABINET
MODELS BB5
TECHNICAL SPECIFICATIONS
DIMENSIONS 460 x 800 x 1400 mm
WEIGHT (EMPTY) 110 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 38 x 12V 40Ah or 120 x 12V 9Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A
CABLE ENTRANCE RIGHT SIDE TOP AND BOTTOM
COLOUR RAL9005

UPS POWER COMPATIBILITY from 1 to 60kVA


STANDARDS
CE - EC IEC-EN 62040-1

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB6

GENERAL CHARACTERISTICS
DIMENSIONS : 800 x 800 x 1400mm

BATTERY VRLA 12V : 60Ah

2 or 3 POLES DC FUSES: 63A-100A-125-160A

BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 20 up to 40 battery 12V 60Ah

UPS 3-POLES (POSITIVE - NEUTRAL - NEGATIVE) :


From 20 up to 40 battery 12V 60Ah

BATTERY CABINET
Battery Cabinet 81

Three-poles DC Fuses 60A - 125A - 160A

Top cable entrance


Bottom cable entrance

4-5 Battery Shelves


Battery VRLA 12V 40h - 60Ah
Max 12 x 12V 60Ah x shelf

BATTERY CABINET
MODELS BB6
TECHNICAL SPECIFICATIONS
DIMENSIONS 800 x 800 x 1400 mm
WEIGHT (EMPTY) 140 Kg
N° OF SHELVES 3
MAX N° OF BATTERY 36 x 12V 60Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A - 160A
CABLE ENTRANCE LEFT SIDE TOP AND BOTTOM
COLOUR RAL9005

UPS POWER COMPATIBILITY from 1 to 100kVA


STANDARDS
CE - EC IEC-EN 62040-1

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB7

GENERAL CHARACTERISTICS
DIMENSIONS : 800 x 800 x 1900mm

BATTERY VRLA 12V : 80Ah-100Ah

2 or 3 POLES DC FUSES: 63A-100A-125A-160A-200A-250A-400A

BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 20 up to 36 battery 12V 80Ah
From 20 up to 36 battery 12V 100Ah

UPS 3-POLES (POSITIVE - NEUTRAL - NEGATIVE) :


From 20 up to 36 battery 12V 80Ah
BATTERY CABINET From 20 up to 36 battery 12V 100Ah
Battery Cabinet 83

Three-poles DC Fuses 60A - 125A - 160A - 250A - 400A

Top cable entrance


Bottom cable entrance

4-5 Battery Shelves


Battery VRLA 12V 80h - 100Ah
Max 8 x 12V 100Ah x shelf

BATTERY CABINET
MODELS BB7
TECHNICAL SPECIFICATIONS
DIMENSIONS 800 x 800 x 1900 mm
WEIGHT (EMPTY) 160 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 36 x 12V 100Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A - 160A - 250A - 400A
CABLE ENTRANCE LEFT SIDE TOP AND BOTTOM
COLOUR RAL9005

UPS POWER COMPATIBILITY from 1 to 1200kVA


STANDARDS
CE - EC IEC-EN 62040-1

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
BATTERY CABINET BB8

GENERAL CHARACTERISTICS
DIMENSIONS : 1400 x 800 x 1900mm

BATTERY VRLA 12V : 80Ah-100Ah

2 or 3 POLES DC FUSES: 63A-100A-125A-160A-200A-250A-400A

BATTERY CONFIGURATIONS
UPS 2-POLES (POSITIVE - NEGATIVE) :
From 40 up to 64 battery 12V 80Ah
From 40 up to 64 battery 12V 100Ah

UPS 3-POLES (POSITIVE - NEUTRAL - NEGATIVE) :


From 40 up to 64 battery 12V 80Ah
From 40 up to 64 battery 12V 100Ah
BATTERY CABINET
Battery Cabinet 85

Three-poles DC Fuses 60A - 125A - 160A - 250A - 400A

Top cable entrance


Bottom cable entrance

4-5 Battery Shelves


Battery VRLA 12V 80h - 100Ah
Max 16 x 12V 100Ah x shelf

BATTERY CABINET
MODELS BB8
TECHNICAL SPECIFICATIONS
DIMENSIONS 1400 x 800 x 1900 mm
WEIGHT (EMPTY) 250 Kg
N° OF SHELVES 4
MAX N° OF BATTERY 64 x 12V 100Ah
IP PROTECTION IP 20 (Optional 21-44)
DC FUSES 63A - 100A - 125A - 160A - 250A - 400A
CABLE ENTRANCE LEFT SIDE TOP AND BOTTOM
COLOUR RAL9005

UPS POWER COMPATIBILITY from 1 to 1200kVA


STANDARDS
CE - EC IEC-EN 62040-1

ALL INFORMATION IS INDICATIVE, MAY BE MODIFIED BY AEC AT ANY TIME AND DOES NOT CONSTITUTE CONTRACTUAL OBLIGATIONS.
ACCESSORIES FOR UPS E CPSS
SNMP CARD

The Simple Network Management Protocol (SNMP) was


created to have a simple communication of information through
computer networks. SNMP is a standard protocol that is part of
the Transmission Control Protocol / Internet Protocol (TCP / IP)
compatible with Internet and Intranet networks.

The SNMP card allows AEC UPSs to be remotely monitored,


assisted, tested and operated anywhere in the world. A SNMP
website itself provides the user with all information relating to
the UPS in a clear and simple manner.

Through the SNMP card, AEC is also able to carry out H24
checks on each UPS, as part of ordinary and / or preventive
maintenance contracts.

DRY CONTACT CARD

The relay or dry contact card provides a series of potential-free normally open or normally closed contacts to signal the
following UPS functions:

• UPS in bypass mode;


• No input network;
• UPS in Inverter mode;
• Batteries not suitable, a check is required;
• Presence of a generic alarm, a check.

It is also possible to carry out manual or automatic shutdowns of the UPS


remotely.

USB CARD

The USB card allows you to connect the UPS to all latest generation
computers via a USB port on the PC. This card is essential if the UPS
does not have the RS232 port and is compatible with all our UPS
models.
87

EXTERNAL MAINTENANCE BYPASS


The maintenance by-pass is a device external to the UPS and allows maintenance or repair / replacement of the UPS without
interrupting the powered user. The AEC external maintenance by-pass, when operated manually or automatically, allows
you to eliminate voltage at the ends of the UPS and therefore carry out battery changes or internal system maintenance by
authorized technicians.

TEMPERATURE SENSOR FOR BATTERIES


In order to preserve the expected life of the batteries and improve their performance, AEC offers the temperature sensor
for external batteries as an accessory for the UPS. Thanks to a probe that communicates with the logic of the UPS, the
batteries will be constantly monitored by compensating the charging current based on the ambient temperature.

AEC APP for SNMP | Remote monitoring


Absolute novelty! AEC UPS APP

Download our App now, subscribe to our


newsletter and visit our constantly updated
catalogs via your smartphone. Through the app
it will be possible to access your account and
monitor all AEC devices connected to it in real
time.

Directly from the AEC App, you can monitor the


status and values, modify parameters and carry
out test tests of your UPS. Live UPS in real time
24 \ 7.

Immediately receive an alert for any type


of anomaly in your UPS system via App
notification, SMS, Email or mobile phone call.

YOUTUBE VIDEO TUTORIAL

ASSISTANCE 24\7 ON ALL SOCIAL NETWORK


LEAD-ACID BATTERIES
AGM VRLA 12V

STATIONARY ACCUMULATORS OZ POWER


HIGH QUALITY AND MAXIMUM PERFORMANCE

OZ Power batteries are a fundamental element for the operation of


UPS units and are specially made to have greater performance even in
extreme contexts. Optimally designed, OZ Power’s UPS batteries are
engineered using the latest in advanced design oxygen recombination
technology and are comprised of lead acid and sealed specifically for
UPS applications.

OZ Power lead-acid AGM batteries can last up to 10-15 years, but can
affect several external factors on battery life such as:
- Incorrect use of the battery;
- Inadequate maintenance carried out by a non-specialized technician;
- Exposure to extreme temperatures, both too high and too low;
- Incorrect recharging of the battery using an unsuitable charger.

OZ Power AGM batteries are always sold fully charged and, once
discharged, it is advisable to fully recharge them to make the most of
their potential and to avoid deteriorating them, thus reducing their
capacity and therefore also their duration. Furthermore, it is strongly
recommended to carry out a full recharge to 100% even in case of
prolonged non-use of the battery and to be checked by a specialized
technician for complete efficiency.
89

BATTERY MODELS
12V OZ POWER:

MAIN CHARACTERISTICS
12V 9Ah
• Totally hermetic without emission of gas in use;
• No liquid to add during the entire life of the batteries;
• No risk of acid loss as the electrolyte (diluted sulfuric acid) is
absorbed in an AGM opaque glass-like support;
• The plates are very robust and are welded with special alloys to
12V 24Ah ensure high mechanical resistance;
• The casing is made of ABS (Acrylonitrile Butadiene Styrene);
• The batteries comply with the international standards JIS, UL, VDE,
IATA;
• The batteries are designed for high fast discharge currents;
• The expected life of AEC batteries is 10-12 years, according to the
12V 40Ah EUROBAT guide;
• Enclosures are constructed to UL-94 HB or UL94-V0 fire resistant.

STATIONARY AGM BATTERIES


12V 60Ah
Using the latest innovative Oxygen Recombination Technology, AEC
has used its 50 years of experience to design and manufacture the
best battery on the market, with an expected life of 10 years on all
models.

12V 80Ah

12V 100Ah
OZ POWER | 12V 9AH
AGM SEALED LEAD BATTERY

TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 9Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 2.40Kg(5.29Lbs)
INTERNAL RESISTANCE <18mΩ
TERMINAL TYPE F2
MAX DISCHARGE CURRENT 130A
DESIGN LIFE 8-10 Years
MAX CHARGE CURRENT 2.7A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15.0V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 151±1 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 65±1 mm
Storage:-15°C~40°C
HEIGHT 94±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 100±1 mm

CONSTANT CURRENT DISCHARGE CHARACTERISTICS: A 25° C


F.V/TIME 5 Min 10 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 10 Hours 20 Hours
1.60V 33 19 16.4 9.78 5.1 2.96 2.16 1.46 0.80 0.461
1.67V 30.8 18.5 15.6 8.9 5.08 2.89 2.13 1.44 0.79 0.452
1.70V 28 18.2 15 8.55 5.02 2.84 2.08 1.41 0.78 0.450
1.75V 25.5 17.5 14.3 8.24 4.92 2.76 2.04 1.93 0.76 0.450
1.80V 22.6 16 13.4 7.5 4.73 2.69 1.99 1.36 0.75 0.400

CONSTANT POWER DISCHARGE CHARACTERISTICS: W 25°


F.V/TIME 5 Min 10 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 10 Hours 20 Hours
1.60V 384.0 249.6 192 110.4 62.4 28.7 23.7 16.1 9.0 4.71
1.67V 371 244.7 188.2 109.2 61.8 29.6 23.6 16.1 9.0 4.71
1.70V 355.7 239 184 107.8 61.1 29.4 23.4 16 8.9 4.70
1.75V 334.8 230.6 178.5 105.4 60.0 28.7 23.2 15.9 8.9 4.68
1.80V 289.2 212.9 170.6 101.5 58.2 27.8 22.7 15.7 8.8 4.59
Battery 12V 9Ah 91

BATTERY DISCHARGE CHARACTERISTICS BATTERY CHARGE CHARACTERISTICS

TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE

CYCLE SERVICE LIFE SELF DISCHARGE CHARACTERISTICS

TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT

CYCLE USE 25°C 2.45 2.40-2.50


0.25°C
STANDBY 25°C 2.275 2.25-2.30
OZ POWER | 12V 24AH
AGM SEALED LEAD BATTERY

TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 24Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 7.0Kg
INTERNAL RESISTANCE <12mΩ
TERMINAL TYPE IT (F12)
MAX DISCHARGE CURRENT 375A (5s)
DESIGN LIFE 8-10 Years
MAX CHARGE CURRENT 7.8A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 166±2 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 175±2 mm
Storage:-15°C~40°C
HEIGHT 125±2 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 125±2 mm

The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.

CONSTANT CURRENT DISCHARGE CHARACTERISTICS: A 25° C


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 99.41 46.76 28.53 15.39 9.41 6.88 4.56 3.04 2.50 1.36
1.65V 93.24 45.29 27.35 15.10 9.25 6.78 4.49 3.01 2.47 1.35
1.70V 86.08 43.92 24.80 14.31 9.07 6.66 4.43 2.97 2.45 1.34
1.75V 85.10 42.45 23.43 14.22 8.82 6.52 4.37 2.93 2.41 1.32
1.80V 75.39 38.63 21.86 14.02 8.53 6.35 4.31 2.88 2.38 1.30

CONSTANT POWER DISCHARGE CHARACTERISTICS: W 25°


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 1070.6 541.2 329.4 188.2 110.6 81.18 54.00 36.29 29.88 16.06
1.65V 1011.8 529.4 320.6 182.4 108.8 80.59 53.53 36.06 29.71 15.98
1.70V 947.1 505.9 311.8 179.4 107.4 78.82 52.88 35.71 29.41 15.88
1.75V 862.7 483.3 300.0 174.1 105.1 77.65 52.18 35.29 29.40 15.71
1.80V 776.5 454.9 287.3 171.6 103.1 75.88 51.29 34.82 28.63 15.49
Battery 12V 24Ah 93

BATTERY DISCHARGE CHARACTERISTICS BATTERY CHARGE CHARACTERISTICS

TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE

CYCLE SERVICE LIFE SELF DISCHARGE CHARACTERISTICS

TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT

CYCLE USE 25°C 2.45 2.40-2.50


0.25°C
STANDBY 25°C 2.275 2.25-2.30
OZ POWER | 12V 40AH
AGM SEALED LEAD BATTERY

TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 40Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 12.40Kg
INTERNAL RESISTANCE <10mΩ
TERMINAL TYPE IT (M)
MAX DISCHARGE CURRENT 380A (5s)
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 12A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 197±3 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 166±1 mm
Storage:-15°C~40°C
HEIGHT 170±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 170±1 mm

The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.

CONSTANT CURRENT DISCHARGE CHARACTERISTICS: A 25° C


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 171.0 81.0 40.9 24.6 13.9 10.10 7.13 5.35 3.90 2.14
1.67V 168.0 75.0 40.0 23.5 13.8 10.00 7.02 5.25 3.85 2.12
1.70V 157.0 72.0 38.9 22.7 13.5 9.62 6.98 5.10 3.81 2.07
1.75V 140.0 66.0 34.9 23.2 13.1 9.27 6.84 5.00 3.80 2.03
1.80V 103.0 61.2 30.7 22.5 12.6 9.17 6.68 4.90 3.80 1.95

CONSTANT POWER DISCHARGE CHARACTERISTICS: W 25°


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 1951 927.0 494.0 272.9 168.0 126.3 87.2 50.0 40.22 21.19
1.67V 1919 913.0 487.0 270.4 167.0 125.7 86.6 49.6 40.20 21.19
1.70V 1795 861.0 459.0 266.9 164.0 120.0 85.2 49.0 40.10 21.08
1.75V 1603 780.0 416.0 262.4 161.0 117.0 83.6 48.4 39.80 21.08
1.80V 1337 663.0 354.0 254.5 155.0 113.0 81.4 47.6 39.30 20.69
Battery 12V 40Ah 95

BATTERY DISCHARGE CHARACTERISTICS BATTERY CHARGE CHARACTERISTICS

TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE

CYCLE SERVICE LIFE SELF DISCHARGE CHARACTERISTICS

TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT

CYCLE USE 25°C 2.45 2.40-2.50


0.25°C
STANDBY 25°C 2.275 2.25-2.30
OZ POWER | 12V 60AH
AGM SEALED LEAD BATTERY

TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 60Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 16.50Kg
INTERNAL RESISTANCE 8mΩ
TERMINAL TYPE IT (M6)
MAX DISCHARGE CURRENT 500A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 15A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 230±1 mm
AMBIENT TEMPERATURE Charge: 0°C~40°C WIDTH 138±1 mm
Storage:-15°C~40°C
HEIGHT 211±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 216±1 mm

The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.

CONSTANT CURRENT DISCHARGE CHARACTERISTICS: A 25° C


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 190.0 100.0 59.4 33.6 20.7 15.80 10.30 6.82 5.73 3.12
1.65V 173.0 94.0 56.3 32.4 20.0 15.30 9.98 6.75 5.72 3.10
1.70V 156.0 88.5 53.3 31.3 19.0 14.70 9.71 6.65 5.56 3.05
1.75V 142.0 83.1 51.3 30.4 18.7 14.30 9.46 6.56 5.50 3.00
1.80V 126.0 76.0 49.4 29.0 18.0 14.10 9.23 6.45 5.18 2.72

CONSTANT POWER DISCHARGE CHARACTERISTICS: W 25°


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 1898 1350 648.0 378.0 235.2 181.2 119.4 79.8 68.4 35.40
1.65V 1762 1272 618.0 367.2 228.6 176.4 115.8 79.2 67.8 35.28
1.70V 1620 1188 588.0 358.2 223.8 170.4 113.4 78.0 66.6 34.86
1.75V 1512 1116 572.4 348.0 215.4 165.6 110.4 77.4 66.0 34.20
1.80V 1368 1032 556.2 334.2 208.8 150.0 108.0 76.2 65.4 33.96
Battery 12V 60Ah 97

BATTERY DISCHARGE CHARACTERISTICS BATTERY CHARGE CHARACTERISTICS

TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE

CYCLE SERVICE LIFE SELF DISCHARGE CHARACTERISTICS

TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT

CYCLE USE 25°C 2.45 2.40-2.50


0.25°C
STANDBY 25°C 2.275 2.25-2.30
OZ POWER | 12V 80AH
AGM SEALED LEAD BATTERY

TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 80Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 20.50Kg
INTERNAL RESISTANCE 6.6mΩ
TERMINAL TYPE IT (M6)
MAX DISCHARGE CURRENT 700A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 22.5A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 259±2 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 168±1 mm
Storage:-15°C~40°C
HEIGHT 208±1 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 212±1 mm

The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.

CONSTANT CURRENT DISCHARGE CHARACTERISTICS: A 25° C


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 240.0 142.2 85.8 50.2 28.9 22.0 14.3 9.35 7.74 4.10
1.67V 222.0 135.3 85.0 47.5 27.8 21.6 14.2 9.30 7.66 4.08
1.70V 205.0 119.6 84.4 46.9 27.6 21.3 14.0 9.20 7.51 4.02
1.75V 195.0 105.9 82.7 45.3 26.8 20.8 13.9 9.08 7.50 4.00
1.80V 180.0 102.0 80.3 43.4 25.6 20.2 13.5 8.99 7.35 3.82

CONSTANT POWER DISCHARGE CHARACTERISTICS: W 25°


F.V/TIME 5 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 8 Hours 10 Hours 20 Hours
1.60V 2520 1488 960 576.0 330.0 241.2 161.4 108.0 90.60 45.32
1.67V 2430 1452 930 565.2 322.8 235.2 160.2 106.2 88.20 45.32
1.70V 2268 1428 876 546.0 315.6 234.0 159.0 103.8 86.40 45.23
1.75V 2136 1350 858 525.0 307.2 231.6 157.2 103.2 85.20 45.00
1.80V 2046 1290 852 511.2 298.8 228.0 155.4 100.8 82.80 44.10
Battery 12V 80Ah 99

BATTERY DISCHARGE CHARACTERISTICS BATTERY CHARGE CHARACTERISTICS

TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE

CYCLE SERVICE LIFE SELF DISCHARGE CHARACTERISTICS

TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT

CYCLE USE 25°C 2.45 2.40-2.50


0.25°C
STANDBY 25°C 2.275 2.25-2.30
OZ POWER | 12V 100AH
AGM SEALED LEAD BATTERY

TECHNICAL SPECIFICATIONS
CELLS PER UNIT 6
NOMINAL VOLTAGE 12
NOMINAL CAPACITY 100Ah@20Hour rate F.V(1.75/cell)
WEIGHT Approx. 28.5Kg
INTERNAL RESISTANCE 5mΩ
TERMINAL TYPE IT (M8)
MAX DISCHARGE CURRENT 1000A
DESIGN LIFE 10-12 Years
MAX CHARGE CURRENT 33A
STAND BY 13.5-13.8V
CYCLE USE 14.4-15V
DIMENSIONS
Discharge: -15°C~50°C LENGTH 330±3 mm
AMBIENT TEMPERATURE
Charge: 0°C~40°C WIDTH 173±2 mm
Storage:-15°C~40°C
HEIGHT 216±3 mm
CONTAINER MATERIAL ABS, UL94-HB & 94V-0 TOTAL HEIGHT 222±3 mm

The OZ 12V range is commonly used in many applications, especially the emergency power supply
of UPS systems. The battery is designed and manufactured to guarantee the highest levels of
performance in rapid discharges, while maintaining maximum reliability and durability over time.
Based on proven AGM VRLA technology, the OZ battery is 99% recyclable at end of life.
OZ 12V does not require any maintenance. In addition, the series is classified as non-dangerous
goods and can be safely transported by truck, rail and air. The specific design has been optimized to
reduce self-discharge during storage.

CONSTANT CURRENT DISCHARGE CHARACTERISTICS: A 25° C


F.V/TIME 5 Min 10 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 10 Hours 20 Hours
1.60V 313.0 238.0 188.5 112.3 66.0 38.0 28.5 18.6 10.5 5.18
1.65V 304.0 230. 178.5 106.7 63.3 37.2 27.6 18.3 10.3 5.13
1.70V 297.0 225.0 165.1 101.8 62.4 35.5 26.0 17.9 10.2 5.11
1.75V 280.0 218.0 154.0 96.5 58.3 32.4 25.4 17.6 10.0 5.10
1.80V 257.0 211.0 143.7 92.1 52.6 29.2 24.6 17.2 9.65 5.05

CONSTANT POWER DISCHARGE CHARACTERISTICS: W 25°


F.V/TIME 5 Min 10 Min 15 Min 30 Min 60 Min 2 Hours 3 Hours 5 Hours 10 Hours 20 Hours
1.60V 3216 2586 2100 1267.8 796.2 451.8 329.4 223.2 129.0 66.6
1.65V 3120 2520 2016 1228.8 774.0 446.4 324.0 220.8 128.4 66.0
1.70V 3054 2460 1921.2 1195.2 753.6 439.2 321.0 217.8 127.2 65.4
1.75V 2880 2400 1830 1165.8 732.6 432.6 316.2 214.2 126.6 65.4
1.80V 2640 2280 1668.6 1125.0 715.2 423.0 308.4 210.0 216.0 64.2
Battery 12V 100Ah 101

BATTERY DISCHARGE CHARACTERISTICS BATTERY CHARGE CHARACTERISTICS

TEMPERATURE EFFECTS IN RELATION TO BATTERY CAPACITY TEMPERATURE EFFECTS ON LONG TERM FLOAT LIFE

CYCLE SERVICE LIFE SELF DISCHARGE CHARACTERISTICS

TECHNICAL SPECIFICATION
CHARGE VOLTAGE V/CELL MAX CHARGE
USE
TEMP. VALUE RANGE CURRENT

CYCLE USE 25°C 2.45 2.40-2.50


0.25°C
STANDBY 25°C 2.275 2.25-2.30
We have been guaranteeing continuity
and reliability since 1968
WE ARE BEHIND THE POWER...

AEC is more than just a


company, AEC is a family, we
are a team of professionals
with passion for innovation
and new technologies
We are AEC!
103

AEC GROUP
Offices in the world

No. 19-11 San Chung Road


Nankang District, Taipei 115 01
Taiwan

AEC PHD Powerhouse Ltd


115 10th Rd, Kew,
Johannesburg 2090, Sudafrica

AEC International Srl Allis Electric Co. Ltd


Via Nerviano 55, Lainate 20045 19-11, Sanchong, Nangang Dist.,
Milan, Italy Taipei City, Taiwan

AEC UPS USA LLC AEC Phd Powerhouse Ltd


244 Biscayne Blvd 33132 115 10th Rd, Kew 2090
Miami, Florida, United States Johannesburg, South Africa
CONTACTS
Main office Head office address
+39 02 94158991 Via Nerviano 55, 20045
Mobile\WhatsApp Lainate, MI
+39 3349785900 Italia

Web & Email


www.aecups.com
[email protected]

You might also like