Medical
PlazMax
P50 P110 P160
The Innovative
Low Temperature
Sterilizer
for Heat-Sensitive
Equipment
Hospitals
Innovative Energy-Saving Solution
The Tuttnauer Plazmax Line
For highly effective sterile processing in
small operating rooms or large Central Sterile
Services Departments (CSSD).
Safe | Reliable | Efficient
• Single phase electrical supply for all models lowers
operational costs
• Green technology - non-toxic emissions to the environment
• Real-time graphical display of cycle parameters
• Multiple model configurations: manual or vertical with single
or double door option
Putting your health
and wellbeing first.
2
Smart Design, Smart Technology
Advanced human
machine interface
(HMI)
Thermal printer
and USB port -
for printing cycle Highly durable stainless
information and -steel panels
downloading data - prevents discoloration and
easily cleaned
Aluminium chamber
- aviation grade
- homogeneous
temperature distribution
Non-toxic H2O2
sterilizing agent
Range of capacities to suit
different tools and
instruments
Vertical sliding door and hands-
free opening device
Contact us
to learn more about green processing.
3
Clean
Using Eco Friendly
Technology H2O2 sterilizing agent
The PlazMax sterilizer inactivates micro-organisms with Hydrogen
Peroxide (H2O2) vapor and plasma. It sterilizes medical devices by
diffusing H2O2 into the chamber and then converting the H2O2 molecules
Non-toxic into a plasma state.
sterilizing agent The sterilization occurs inside the chamber by means of H2O2 vapor.
The PlazMax utilizes the bacterium killing power of free radicals in
the H2O2 molecules released by applying heat to the H2O2 gas in the
vaporizer.
The combined use of H 2O 2 vapor and plasma, safely and quickly
sterilizes medical instruments and materials without leaving dangerous
residues, thus offering an effective, reliable, economical, and easy
No water sterilization method.
consumption
User-Friendly Operation
Sophisticated HMI Touch Screen
• Multi-color display
Decreased electricity • Multilingual (26 languages)
consumption • Real-time dynamic graph display (chamber pressure &
cycle process)
• Process data display (pressure, temperature,
vaporizer temperature)
R.PC.R Software
Automatic tracking cycle information
No toxic residue, to your PC (optional). Allows remote
only water and oxygen monitoring of the sterilizer’s operation.
Simple to Operate and Monitor
Thermal printer and Tracking equipment and
USB port maintenance notifications
Diagnostic in/out Remote-control operating
tests for individual and monitoring
components
Hands-free opening device ultiple access levels
M
and vertical sliding door and user passwords
4
Sterilization Process
Air removal
from
chamber
Preparation for
diffusion
Diffusion (sterilization
stage) - instruments
are exposed to the
H2O2 vapor
Gas removal from
chamber & breaking
apart H2O2 molecules
Repeat diffusion stage
6 (sterilization) and
Aeration stage - H2O2 gas removal
removal of residue
Sterilization Cycle and Test Programs
Normal Cycle Advanced Cycle
Model Endoscope * Test Cycles Description
(Non-hollow loads) (Hollow loads)
Cycle Time (min.) Cycle Time (min.) Cycle Time (min.) Cycle Time (min.)
P50 35 40 32 Test I Penetration Test
P110 39 44 37 Test II Leakage Test
P160 43 48 41
Note: Cycle times are based on a hot cycle and may
* Endoscope cycle: Short heating time and reduced H2O2 exposure time vary according to load volume
5
Types of Loads & Cycles
The PlazMax Line offers regular sterilization cycles for non-hollow loads, advanced
sterilization cycles for hollow loads, and a unique endoscope cycle.
Non-Hollow Loads Hollow Loads Endoscope Cycles
Electrocautery instruments Surgical power drills Rigid scopes for optics
Defibrillator paddles
Shaver handpieces Flexible endoscope
6
The Tuttnauer PCD Kit
Flexible Endoscope Simulation Kit
Assuring effective penetration and successful sterilization
Our unique PCD kit simulates long and challenging lumen configurations (1mm inner
diameter lumen and up to 4m long for double side open ends and 1.4m with one
dead-end), to assure complete sterilization penetration with full exposure to the
vaporized hydrogen peroxide sterilizing agent.
Comprehensive Tuttnauer Consumables
Chemical Indicators Biological Indicators Self-Sealing Pouches
To be used with every cycle and every packed To be used according to hospital policies Tuttnauer offers a wide range of sealing
item, validating penetration and ensuring and schedules, validating sterilization and packaging products to support your
load contact with the vaporized hydrogen efficiency and scope. entire packaging process.
peroxide..
7
Technical Specifications
External Dimensions No. of Baskets Power (W) Voltage (V)
Model Chamber Volume
(WxHxD/D 2-doors) mm (WxD cm) Current (A) 1-Phase 50-60 Hz
P50 47 702 x 1528 x 729 / 736 1 (40 x 60) 3100 W 13.5 A 230 V
P110 109 702 x 1768 x 729 / 736 2 (40 x 60) 4300 W 18.7 A 230 V
P160 162 702 x 1768 x 1029 / 1036 2 (40 x 90) 4300 W 18.7 A 230 V
PlazMax P50 PlazMax P110 PlazMax P160
47 Liter c hamber 109 Liter Chamber 162 Liter Chamber
180mm
420mm
420mm
624mm 624mm
924mm
420mm 420mm 420mm
PlazMax - Excellent Quality, Excellent Results
PlazMax complies with strict international standards and directives, to ensure quality and
effective sterilization:
• ISO 9001:2015 • ISO 13485:2016 • ISO 14937 • EN 61010-2-040:2015 • EN 60601-1:2006/AC:2010
Medical Device Directive 93/42/EEC
The PlazMax Sterilization Line can be used for applications and instruments that are suitable
for plasma sterilization, as per manufacturer’s guidelines.
Hospitals
Distributed by:
LTR330-0061/PLASMAX/V-8/07.20
Learn from our experts
Join our blog tuttnauer.com/blog