Encoder EM6422

Pulse emitter for positive displacement meters


Data sheet: DS/EM/0002/EN Ed. February 2013

The pulse emitter “EM6422” converts the rotary


motion of a Positive Displacement Flowmeter into
electric pulses. It allows the meter to interface with
ISOIL electronic counters (VEGA II, VEGA T).

EM6422 “type A” may be mounted directly onto all


recently built ISOIL p.d. meters.
“Type B” may be mounted on all previous versions of
ISOIL meters by means of and adapter.
On demand, by means of dedicated flanges, it may
be installed on meters from different brands.

EM6422 is made of an aluminum encasing divided


into compartments, each separated from the other
by an aluminum wall.
In one of the two compartments, a small shaft,
installed on a roller bearing, is connected at one end
to the output shaft of the pd meter, while on the
other end, close to the separating aluminum wall, the
The electronic counter receives a number of pulses
small shaft is connected to a magnet. Inside the
proportional to the delivered volume. The integrity of
adjacent compartment, another magnet detects
the electronic circuit and wiring is checked by
the rotation of the small shaft and causes an
comparing the count on both channels and the flow
electronic circuit to generate electric pulses.
direction is detected by the pulse sequence.
Thus, there is no need in the p.d.meter for dynamic
seals that sometimes cause leaks due to the wear
CAN bus transmission
over time.
The encoder is provided with a micro-controller that
counts pulses coming from magnet sensor (A, B and
The housing closed by a cover with O-ring and with a
Index channels).
threaded female inlet for entering of the cable by
counduit or cable gland.
The number of generated pulses (64 or 256 pulses per
round) and frequency data are sent to the flow
The electric wiring is done by using a removable
computer through a CAN bus connection by means
terminal block which is easily accessible once the
of a ISOIL proprietary protocol.
cover has been removed.
Protocol includes a key controller to avoid tempering
Two versions of the pulses emitter EM6422 are sold: pulses
of legally relevant data. The integrity of the
transmission and CAN bus.
electronic circuit is checked by monitoring the
sequence on A, B and index channels, and the
Pulses transmission
coupling between the magnet and the sensor.
The shaft is connected on one end to the shaft on the
Any malfunction can be immediately detected by
p.d.meter and during each meter rotation 64 or 256
monitoring status on CAN bus protocols.
pulses (see models) are generated on two A and B
channels, 90° electrical degrees of phase shift.
Electronic counter VEGAII/VEGAT linked with EM6422
The coupling between the magnet and the sensor is
CAN bus need a specific firmware.
continuously monitored by the electronic circuit. Any
Ask ISOIL for information.
malfunctioning will result in a pulse transmission on a
single channel only and the fault may be checked by
the associated electronic counter.

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: [email protected] Pag. 1/2
DS/EM/0002/EN – 02/2013
TECHNICAL CHARACTERISTICS
Housing material: Anodized aluminium alloy
Shaft material: Stainless steel (AISI 304)
Operating speed (input revolution): 0÷1000 rpm
Cable/conduit entry: ½” NPT
Gaskets: Viton (standard) or Nitrile (on request)
Weight: 1000 gr
Mechanical protection: IP66
Ex protection: II 2 G Ex d IIB T5 Gb
Working temperature: -20 ÷ +75°C : Viton Gaskets (standard);
-30 ÷ +75°C : Nitrile Gaskets (on request)
Humidity: 0÷100 % non-condensing
Supply voltage: 5÷30 VDC
Pulses resolution: 64 pulses or 256 pulses/revolution
Operating: Bidirectional
Terminal block: Pull-out, 5 positions for wires (0,2÷1,5 mm2), shielded
Pulses Trasnmission
Current supply: 40 mA max
Phase shift (A and B channel): 90e° ±5%
Duty cycle: 50/50 ±5%
Pulses output: Open drain FET. Pull-up resistor 4,7 KΩ can be set by dip switch
Current sinking (A and B channel): 50 mA for channel
CAN bus Transmission
Current supply: 70 mA max
Serial communication: Interface: CAN bus
Speeds: 50/125 Khz by dip-switch selection
Identifiers: 21÷24 (Hex) by dip-switches selection

ISOIL p.d. meters  EM6422 64 pulses/revolution


Model pulses/liter Model pulses/liter Model pulses/liter
SBM 32 133,1 BM 200 28,1 LBM 1000 4,3
SBM 75 102,4 BM 400 14,1 LBM 3000 2,2
SBM 150 28,1 BM 600 9,4
S 9000 13,0 P 4000 13,0

ISOIL p.d. meters  EM6422 256 pulses/revolution


Model pulses/liter Model pulses/liter Model pulses/liter
SBM 32 532,4 BM 200 112,4 LBM 1000 17,2
SBM 75 409,6 BM 400 56,4 LBM 3000 8,8
SBM 150 112,4 BM 600 37,6
S 9000 52 P 4000 52

Dimensions Pulse emitter EM6422 model: X X X 1 X

Type A: for new Isoil p.d.meter A


Type B: for preexistent Isoil p.d.meter B

64 pulses/revolution (standard) 1
256 pulses/revolution (on request) 2

Pulses trnasmission 1
CAN bus transmission 2

Cable entry ½” NPT 1

Gaskets in VITON (standard) 1


½” NPT Gaskets in NITRILE (on request) 2

ISOIL IMPIANTI S.p.A. - 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web: www.isoilmeter.com e-mail: [email protected] Pag. 2/2
DS/EM/0002/EN – 02/2013