MCHB Abb - 13122017
MCHB Abb - 13122017
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
E E
A A
NO. CATOGARY DESCRIPTION NO. CATOGARY QTY. DESCRIPTION
1 TECHNICAL System : 22kV 3 PHASE 3 WIRE 50Hz 9 PACKING DETAILS Domestic
CHARACTERISTIC Rated Voltage : 24 kV
Power-frequency withstand voltage: 50 kV
Lighting impulse withstand voltage: 125 kV 10 NOTE
Rate short time withstand current: 25 kA / 1 s
Rate peak withstand current: 63 kA
2 CONSTRUCTION Type : UniGear ZS1
Material : Metal-clad Switchgear
Access Location : Front Access
B Switching Device Type : Withdrawable Vacuum Circuit Breaker B
Degree of Protection : External - IP 4X, Internal - IP 2X
3 PAINT FINISH Doors and End Covers : RAL7035 "Light Grey"
Remainder : Aluminium-Zinc Steel Sheets 11 REMARKS
4 BUSBAR RATING Main Busbar Rated Current : 2500 A Size : 2 x 80 x 10mm²
Earth Bar Size : 1 x 30 x 8mm²
Insulation : YES Finishing : Insulated Copper
5 AUXILIARY CIRCUIT Voltage Supply :
- Protection, Control & Indication 110V DC
- Circuit Breaker Spring Charge Motor 110V DC
- Panel Heater & Cubicle Lighting 220V AC, 50Hz
Wire Size :
C - Control Circuit 1.5mm² Colour : Grey C
- Lighting & Heating Circuit 1.5mm² Colour : Black
- Current Transformer
Phase L1 4.0mm² Colour : Red
Phase L2 4.0mm² Colour : Yellow
Phase L3 4.0mm² Colour : Blue
Phase N 4.0mm² Colour : Black
- Voltage Transformer
Phase L1 2.5mm² Colour : Red
Phase L2 2.5mm² Colour : Yellow
Phase L3 2.5mm² Colour : Blue
Phase N 2.5mm² Colour : Black
D - Earthing Cable 2.5mm² Colour : Green/Yellow D
Wire Specification : 450/750V
Terminal Block : PHOENIX
Test Terminal Block : PHOENIX
Cable Termination : Blade
Cable Marker : Hot Marker
Cable Tray : Self-Extinguishing, Warp Proof PVC
Maximum Service Temperature : 85°C
6 POWER CABLE Entry : Bottom
Maximum Cable Size :
Terminating Facility : Undrilled Aluminium Gland Plate Only
7 CONTROL CABLE Entry : Bottom
E 8 LABEL Black Letter on White Background E
Material : Plastic
Fixing : Internal - Self Adhesive
External - Self Adhesive
NOTE: TAIFF METER A1700, PROTECTION RELAY GRE130, GRE110 AND MULTIMETER ELITE 448 ARE OUT OF ABB SCOPE
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
P2 P2 P2 P2 P2 P2
B B
TO NEXT PAGE
-PU -PU -PU -PU -PU -PU -PU
C C
CABLE CT
EARTHING SWITCH ST2 ST2 ST2 ST2 ST2 ST2
HV FUSE
SURGE ARRESTER
VOLTAGE TRANSFORMER
MEASURING MULTI METER MULTI METER MULTI METER MULTI METER MULTI METER MULTI METER
INSTRUMENTS E448/CEWE/MODBUS TCP/IP E448/CEWE/MODBUS TCP/IP E448/CEWE/MODBUS TCP/IP E448/CEWE/MODBUS TCP/IP E448/CEWE/MODBUS TCP/IP E448/CEWE/MODBUS TCP/IP
TARIFF METER TARIFF METER TARIFF METER TARIFF METER TARIFF METER TARIFF METER
A1700/ELSTER A1700/ELSTER A1700/ELSTER A1700/ELSTER A1700/ELSTER A1700/ELSTER
NOTE: TAIFF METER A1700, PROTECTION RELAY GRE130, GRE110 AND MULTIMETER ELITE 448 ARE OUT OF ABB SCOPE
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
3P3W, AC24kV, 2500A, 25kA/1s, 50Hz
FROM PREVIOUS PAGE
-QI -QB
630A VCB
M 2500A
-PU P2 -BC
B B
-BV P1
-QE -QE
-PU -PU
-GND
EATHING SYSTEM OF SUBSTATION (BY OTHERS)
A A
8660 mm
B W
W W W W W W
W
B
2325
13 13 13 13 13 13 13 13 13
12 11 11 12 11 11 12 11 11 12 11 11 12 11 11 12 11 11 12 12
11 11 11 11 12 11 11
C 30 1000 800 800 800 800 800 800 1000 800 1000 30 C
PANEL NO. =J1.10 =J1.9 =J1.8 =J1.7 =J1.6 =J1.5 =J1.4 =J1.3 =J1.2 =J1.1
= J
FRONT
PANEL DEPTH : 1700mm
LEGEND:
E 11 GUIDING HOLE FOR CB/VT TRUCK E
12 OPENING FOR EARTH SWITCH AND INDICATOR
13 OPENING FOR RACKING IN & RACKING OUT OF CIRCUIT BREAKER/VOLTAGE TRANSFORMER
14 OPENING FOR MANUAL SPRING CHARGED WHEN CB DOOR IS CLOSING
A A
=J1.10 =J1.9 =J1.8 =J1.7 =J1.6 =J1.5 =J1.4 =J1.3 =J1.2 =J1.1
opening for power opening for power opening for power opening for power opening for power opening for power opening for power opening for power opening for power
cables cables cables cables cables cables cables cables cables
B B
1000 800 800 800 800 800 800 1000 800 1000
C FRONT C
D D
E E
40
40
40
150
150
150
150
430
>0,5
430
680
100 800 100 100 600 100
150 300
1590
1590
680
1590
680
1700
1590
1400
1700
1700
1400
1400
1400
opening for pow er
80
cables
800
200
200
B 65 65
B
Ø16
65 65 opening for control
Control cables entry Control cables entry
Control cables entry cables
BASE IRONS ON CONCRETE FLOOR
80 200
200
200
4-mounting hole
200
4-mounting hole (4-M12)
4-mounting hole 4-mounting hole
(36X20) (36X20) (36X20)
80
80
40
80
40
40
40
70
70
70
105 790 105 105 590 105 105 590 105 105 790 105
800 1000
1000 800
A 1
FOR PANEL=J1.3
- K
A 2
FOR PANELS= J1.1, J1.10 FOR PANEL =J1.4~J1.9 FOR PANEL = J1.2
80
Ø16
790 590
105 105 105 105 590
105 105
40
40
40
150
150
150
150
430
430
680
100 800 100 100 600 100
M12
300
THREADED HOLE ON METAL STRUCTURE
680
680
1590
1590
1590
1700
1700
1400
D D
1590
1400
1400
1700
1400
opening for pow er
cables
Power cables entry Power cables entry
800
200
200
65 65 65
Control cables entry 65 opening for control
Control cables entry cables
Control cables entry
200
80 200
4-mounting hole
200
M12
200
4-mounting hole (4-M12)
4-mounting hole
(36X20) (36X20) 4-mounting hole
THROUGH HOLE ON METAL STRUCTURE
80
80
40
40
40
(36X20)
80
40
70
70
70
105 790 105 105 590 105 105 790 105
105 590 105
1000 800 1000
800
FOR PANEL=J1.3
FOR PANELS= J1.1, J1.10 FOR PANEL =J1.4~J1.9 FOR PANEL = J1.2
E E
A BUSBAR
1
B CABLE
B B
LEGEND :
1 LV COMPARTMENT
2
2 CB COMPARTMENT
A 3 CABLE COMPARTMENT
4 EARTHING SWITCH
2325
B
7
2200
45 60
45 60
45 60
C 2-
∅1
7
2-
∅1
7
2-
∅1
7 8 INSULATOR C
50 50 50
275 275
1675
6 4
45 50
45 50
45 50
D D
3 7 7 7
∅1 ∅1 ∅1
417
2- 50 2- 50 2- 50
275 275
5
1700
45 40
45 40
7 7 7
∅1 ∅1 ∅1
2- 50 2- 50 2- 50
275 275
A A
632 LEGEND :
1 LV COMPARTMENT
2 CB COMPARTMENT
3 CABLE COMPARTMENT
4 EARTHING SWITCH
1 5
6 CURRENT TRANSFORMER
705
7
180
B B
8 INSULATOR
180
A
Shutter painted "Signal Red" color 537 in BS381C,
Labelled " BUSBAR" with white letters.
C BUSBAR C
2325
A
B
2200
6
B CABLE
1675
1620
4
Labelled " CABLE" with white letters.
8 80
3 7
∅1
D D
45
210 210
467
60
7
∅1
5
112 583
45
1700 210 210
A A
632
B 1 B
Shutter painted "Signal Red" color 537 in BS381C,
180
Labelled " BUSBAR" with white letters.
A BUSBAR
180
A 2
C C
2325
2200
1674
D LEGEND : D
1 LV COMPARTMENT
3 2 CB COMPARTMENT
3 CABLE COMPARTMENT
4
5 VOLTAGE TRANSFORMER
6
5 7
E 8 E
1700
A A
1
180
180
LEGEND :
B B
1. LV COMPARTMENT
2 2. LOAD SWITCH COMPARTMENT
50W
3. CABLE COMPARTMENT
2325
2200
4. EARTHING SWITCH
2200
5. FUSE
6.
1675
7. HEATER
C C
8
8. INSULATOR
5
7
100W
450
4
188
5
D D
1700 1000
40 40 40
E E
∅13
∅13
∅13
45
45
45
275 275
B CABLE
1
LEGEND :
180
B 1 LV COMPARTMENT B
2 LINK TRUCK COMPARTMENT
3 CABLE COMPARTMENT
2
A
6 DUMMY CT
100 100 100 7
2325
B
8 INSULATOR
2200
45 60
45 60
45 60
7 7 7
C 2-
∅1
50 2-
∅1
50 2-
∅1
50
C
275 275
1675
45 50
45 50
45 50
D D
3 7 7 7
∅1 ∅1 ∅1
2- 2- 2-
417
50 50 50
275 275
5
1700
45 40
45 40
7 7 7
∅1 ∅1 ∅1
2- 50 2- 50 2- 50
275 275
A A
5.MAIN PANEL LABELS
MATERIAL OF LABELS: ACRYLIC
FIXING OF LABELS: SELF ADHESIVE
10
LINE 1 White background
20
Black text (H=20)
8
B B
60
LINE 2
12
Black text (H=12)
10
PANEL LABEL PANEL LABEL
200
E E
A A
Serial number: /PANEL Serial number: /PANEL Serial number: /PANEL Serial number: /PANEL Serial number: /PANEL
Prod. Year: 2017 IEC62271-200 Prod. Year: 2017 IEC62271-200 Prod. Year: 2017 IEC62271-200 Prod. Year: 2017 IEC62271-200 Prod. Year: 2017 IEC62271-200
B UniGear ZS1 Metal-clad Switchgear UniGear ZS1 Metal-clad Switchgear UniGear ZS1 Metal-clad Switchgear UniGear ZS1 Metal-clad Switchgear UniGear ZS1 Metal-clad Switchgear B
Rated voltage 24 kV Rated voltage 24 kV Rated voltage 24 kV Rated voltage 24 kV Rated voltage 24 kV
Rated current 2500 A Rated current 2500 A Rated current 1250 A Rated current 2 A Rated current 6 A
Rated lightning impulse withstand voltage 125 kV Rated lightning impulse withstand voltage 125 kV Rated lightning impulse withstand voltage 125 kV Rated lightning impulse withstand voltage 125 kV Rated lightning impulse withstand voltage 125 kV
Rated power-frequency withstand voltage 50 kV Rated power-frequency withstand voltage 50 kV Rated power-frequency withstand voltage 50 kV Rated power-frequency withstand voltage 50 kV Rated power-frequency withstand voltage 50 kV
Rated current of main busbar 2500 A Rated current of main busbar 2500 A Rated current of main busbar 2500 A Rated current of main busbar 2500 A Rated current of main busbar 2500 A
Rated short time withstand current ( 1 s ) 25 kA Rated short time withstand current ( 1 s ) 25 kA Rated short time withstand current ( 1 s ) 25 kA Rated short time withstand current ( 1 s ) 25 kA Rated short time withstand current ( 1 s ) 25 kA
Rated peak withstand current 63 kA Rated peak withstand current 63 kA Rated peak withstand current 63 kA Rated peak withstand current 63 kA Rated peak withstand current 63 kA
Rated frequency 50 Hz Rated frequency 50 Hz Rated frequency 50 Hz Rated frequency 50 Hz Rated frequency 50 Hz
Protection class IP4X Protection class IP4X
C Protection class IP4X Protection class IP4X Protection class IP4X C
Made by ABB Made by ABB Made by ABB Made by ABB Made by ABB
PANEL =J1.1 PANEL =J1.10 PANEL = J1.4~J1.9 PANEL = J1.2 PANEL = J1.3
D D
E E
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
C C
D D
E E
Standardization
- CLOSE: RED
A - OPEN: GREEN
DEVICE TAG LIST A
T OSH IBA
AR30
GRE110
PU
VOLTAGE INDI CATOR POWER
H24 YW1P-2EQM3A FAN FAILURE
BLOCK
L1 L2 L3
L OC AL R EM OT E
H EAT ER
OFF
SOT YW1L-MF2E11QHR CB OFF PBL (RED)
ON
XMA1
S AL Z E R S AL Z E R
L1 L2 L3 PE
L1 L2 L3
AR27 AR81
T OSH IBA GRE130 T OSH IBA GRE130
H20 YW1P-2EQM3W HEATER ON I/L (YELLOW)
PM Elite 448 MULTIFUNCTION METER
H20
PU DXN-Q-1 VOLTAGE INDICATOR
KTT-0 4 S
E E
800
Standardization
A
- CLOSE: RED
- OPEN: GREEN
DEVICE TAG LIST A
DESIGNATION TYPE SPECIFICATION
ELSTER (Alpha Meter 1700)
AR30 GRE110-422A-10-C0 PROTECTION RELAY
P1 H20 YW1P-2EQM3W HEATER ON I/L (YELLOW)
P1 SI10-B SQUARE SEMAPHORE
PJ P2
P2 SI10-E ROUND SEMAPHORE
PJ A1700 TARIFF METER
T OSH IBA
AR30
GRE110
PU
VOLTAGE INDI CATOR POWER
BLOCK
PM Elite 448 MULTIFUNCTION METER
PU DXN-Q-1 VOLTAGE INDICATOR
L1 L2 L3 PE
B B
L1 L2 L3
PM
SOC YW1L-MF2E11QHG CB ON PBL (GREEN)
Elite 440
F3
(LOCAL/REMOTE)
F4
S AL Z E R SAL ZE R
SAL ZE R
L1 L2 L3 PE
L1
PM
L2 L3
SAL ZE R
E SS1 E
XMA1 SOT YW1L-MF2E11QHR CB OFF PBL (RED)
SS1 M220-61639-003M1 CONTROL MODE SW
800 (LOCAL/REMOTE)
XMA1 KTT-04S TEST BLOCK
CAPACITOR PANELS =J1.4
A A
P1
DEVICE TAG LIST
P2
PU
DESIGNATION TYPE SPECIFICATION
H20 YW1P-2EQM3W WHITE, 230/240V AC/DC
VOLTAGE INDI CATOR POWER
BLOCK
L1 L2 L3 PE
L1 L2 L3
1000
C C
L1 L2 L3
E H EAT ER
OFF
E
ON
S AL Z E R
SS5
1000
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
B B
C C
D D
E E
-XH 3 -XH 3 -XH 3 -XH 3 -XH 3 -XH 3 -XH 3 -XH 3 -XH 3 -XH 3
EXTERNAL SIDE -XI4 1 INTERNAL SIDE
A -XJ 1 -XJ 1 -XJ 1 -XJ 1 -XJ 1 -XJ 1 -XJ 1 -XJ 1 -XJ 1 -XJ 1 DC CONTROL A
-XJ 3 -XJ 3 -XJ 3 -XJ 3 -XJ 3 -XJ 3 -XJ 3 -XJ 3 -XJ 3 -XJ 3 SUPPLY BY ABB
-XI1 1 -XI1 11
-XI1 5 -XI1 12
-XI1 1 -XI1 13
C -XI1 5 -XI1 14 C
-XI1 1 -XI1 15
-XI1 5 -XI1 16 50BF TRIP SIGNAL
TO EACH PANELS
-XI1 1 -XI1 17
-XI1 5 -XI1 18
-XI1 1 -XI1 19
-XI1 5 -XI1 20
-XI1 1 -XI1 21
-XI1 5 -XI1 22
D D
-XI5 1 -XI5 1 -XI5 1 -XI5 1 -XI5 1 -XI5 1
-XI5 3 -XI5 3 -XI5 3 -XI5 3 -XI5 3 -XI5 3
-XI5 5 -XI5 5 -XI5 5 -XI5 5 -XI5 5 -XI5 5 LOAD SHEDDING
-XI5 7 -XI5 7 -XI5 7 -XI5 7 -XI5 7 -XI5 7
-XI5 9 -XI5 9 -XI5 9 -XI5 9 -XI5 9 -XI5 9
-XI4 1 -XI4 1 -XI4 1 -XI4 1 -XI4 1 -XI4 1 -XI4 1 -XI4 1 -XI4 1 -XI4 1
E -XI4 5 -XI4 5 -XI4 5 -XI4 5 -XI4 5 -XI4 5 -XI4 5 -XI4 5 -XI4 5 -XI4 5 E
-XI4 7 -XI4 7 -XI4 7 -XI4 7 -XI4 7 -XI4 7 -XI4 7 -XI4 7 -XI4 7
-XI4 9 -XI4 9 -XI4 9 -XI4 9 -XI4 9 -XI4 9 -XI4 9 -XI4 9 -XI4 9
-XI4 11 -XI4 11 -XI4 11 -XI4 11 -XI4 11 -XI4 11 -XI4 11 -XI4 11 -XI4 11 ALARM CIRCUIT
-XI4 13 -XI4 13 -XI4 13 -XI4 13 -XI4 13 -XI4 13 -XI4 13 -XI4 13 -XI4 13
-XI4 15 -XI4 15 -XI4 15 -XI4 15 -XI4 15 -XI4 15 -XI4 15 -XI4 15 -XI4 15
-XI4 17 -XI4 17 -XI4 17 -XI4 17 -XI4 17 -XI4 17 -XI4 17 -XI4 17 -XI4 17
-XI4 19 -XI4 19 -XI4 19 -XI4 19 -XI4 19 -XI4 19 -XI4 19 -XI4 19 -XI4 19
-XI4 21 -XI4 21 -XI4 21 -XI4 21 -XI4 21 -XI4 21 -XI4 21 -XI4 21 -XI4 21
-XH 14 -XH 17
A -XH 15 -XH 18 FAN CONTROL BY ABB A
-XI3 3 -XI3 1
-XI1 1 -XI1 3
-XI1 2 -XI1 7 VOLTAGE TRIP FROM VT
B -XI1 2 -XI1 3
B
-XI1 6 -XI1 4
C C
D D
E E
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
EF FAN 220VAC FAN FOR VCB SUPPLY BY CNABB 1 SUPPLY BY CNABB Voltage Supply: 220VAC
A A
EH1 50W220VAC ANTI-CONDENSATION SUPPLY BY CNABB 1 BOXIN 50W, 220VAC, 50Hz
HEATER
QB VD4/P24.25.25P275 VACUUM CIRCUIT BREAKER SUPPLY BY CNABB 1 ABB XIAMEN 2500A, 24kV, 25kA, 3sec, POLES DISTANCE : 275mm.
Operation sequence: O-0.3s-CO-15s-CO
BC1...BC3 LZZBJ9-24/178h/4 WOUND TYPE CURRENT SUPPLIED BY CNABB 3 CNITS Ratio:1250-2500/1/1/1A
TRANSFORMER Core 1:CL0.5FS10, 15VA @ 1250/1A,15VA @2500/1A
Core 2: CL5P20, 10VA @ 1250/1A,15VA @ 2500/1A
Core 3: CL5P20, 10VA @ 1250/1A,15VA @ 2500/1A
Frequency:50Hz
B Insulation level: 24/50/125kV B
Ith: 25kA/3sec
Idyn:63kA
POLARITY:P1-P2
LV terminal block close to P1
BU1...BU3 CGR_24kV CAPACITIVE VOLTAGE SUPPLY BY CNABB 3 PEAKS RATED VOLTAGE: 24kV
DIVIDER
QE ST TYPE EARTH SWITCH SUPPLY BY CNABB 1 24kV, 25kA, 3sec, POLES DISTANCE: 275mm
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
SS5 M220-61638-003M1 2-POSTION SELECTOR 1YUX500008B0012 1 SALZER 2 POLES, Ith: 20A, SIZE: 48x48mm²
A SWITCH LEGEND: FAN MODE, LABEL: OFF/ON A
XMA1 KTT-04S TEST TERMINAL 1YUX500011B0001 1 KACON 4 POLES, PLUSH MOUTED
C KBF1;KBF2;KBP; BC6-30-10 MINI CONTACTOR RELAY GJL1213001R0104 6 ABB VOLTAGE: 110-125VDC, CONTACTS: 3NO+1NO C
KCBO;KCBT;KESO
KBR MY4N_220VAC General purpose relay 1YUX500022B0024 1 OMRON STANDARD TYPE
COIL VOLTAGE: 220/240VAC
WITH INDICATOR
4 CHANGE OVER CONTACTS
KBR PYF14A-E Socket relay 1YUX500007B0008 1 OMRON TYPE: DIN-RAIL/ SCREW MOUNTING 4 POLES FINGER
PROTECTION
KT GE1A-B30HA220 DELAY TIMER RELAY 1YUX500022B0025 1 IDEC Electronic Timer
Supply Voltage: 220-240 VAC
D Contact Output: 5A D
Set time range:1s-30h
Including Dust Cover: GE9Z-C48
KT SR2P-06A RELAY SOCKET 1YUX500022B0026 1 IDEC SOCKET FOR TIMER RELAY: GE1A
S101 V15F-070C Door Limit Switch 1YUZ500019A0006 1 KACON Door Limit switch
Type: V15F-070C
CONTACTS: 1 CHANGE-OVER
Manufacturer: Kacon
E E
Y
A B A
+CB-QB
VD4/P
2500A
+CCB +CCB +CCB
-BC1 -BC2 -BC3
P2 P2 P2
3x1250-2500/1/1/1A
CORE3:CL5P20
B 10VA@1250/1A B
TO SHEET A04
15VA@2500/1A
CORE2:CL5P20
10VA@1250/1A
TO SHEET A03
15VA@2500/1A
CORE1: CL0.5FS10
15VA@1250/1A
TO SHEET A02
C 15VA@2500/1A C
+LVD
-PU
P1 P1 P1
1
R:L1
1
Y:L2
D D
1
B:L3
E:PE
-GND
-QE
E E
L1 L2 L3
3x1250-2500/1/1/1A
CORE1: CL0.5FS10 , 15VA@1250/1A , 15VA@2500/1A ,
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
-GND
A A
C METAL JUMPER C
REMOVE WHEN CONNECT TO LOAD
=EXT
D D
E E
3x1250-2500/1/1/1A
CORE2:CL5P20 , 10VA@1250/1A , 15VA@2500/1A ,
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A -GND A
COM
M
D D
-XA2 12
1 RD 3 YE 5 BU 7 BK
+LVD-XMA1 L1 L2 L3 N
L1 L2 L3 N
2 RD 4 YE 6 BU 8 BK
E L1 L2 L3 N E
-TB2 1 3 5 8
+LVD IA IB IC N
-AR30
/N01/1.A IA IB IC IE
N N N Ie
-TB2 2 4 6 7
-XA2 13 -XA2 14
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S INCOMING PANELS =J1.1 SCALE: 1: 1
CUSTOMER: POWER CIRCUIT START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J01+WLV/A03
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: A04
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
CURRENT TRANSFORMER
3x1250-2500/1/1/1A
CORE3:CL5P20 , 10VA@1250/1A , 15VA@2500/1A ,
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
-GND
METAL JUMPER
-XA3 5 -XA3 6 -XA3 7
REMOVE WHEN CONNECT TO LOAD
C C
=EXT
E E
B B
110V DC 110V DC
-XJ 2 -XJ 4
C C
1 3 12 14 1 3 12 14 1 3 12 14
-FB1 -FB2 -FB3
S202-C6 2 4 11 S202-C6 2 4 11 S202-C6 2 4 11
6A 6A 6A
/X01/2.C
/X01/2.C
/X01/3.C
D D
-XDB 1 -XDB 2
+CB -XB 25
-QB 2
/M01/1.A
-BS1
E 1 E
-MS M
-DC_L1+
-DC_L3+
-DC_L1-
-DC_L3-
/M04/1.A
/M08/1.A
/M04/1.F
/M08/1.F
-XB 35
220V AC, 50Hz 220V AC, 50Hz 220V AC, 50Hz 220V AC, 50Hz
A A
PREVIOUS NEXT PANEL
PANEL
B B
-XH 2 -XH 4
1 3 12 14
-FB4
S202-C6 2 4 11
6A
/X01/3.C
-SS5 4
8
ON
/N99/5.B -KT
-XH 12 /N99/5.D
1
15 A1
-S101
2 -BR -BR
5 6
/N99/3.D /N99/3.D
SUPPLY VOLTAGE
-XH 15
16 18 2
D D
-XH 13 +CB
-EF 2 3
/N99/1.C
-XH 14 2 A2
S231
1 1 X1 -KT 1
A1 +CCF +CB +LVD Z1/1
/N99/5.D 14
-EH2 -EH1 -H20 X2 +CB -KBR
1
-EL 100W 2 50W 2 WHITE
-EF 13
220-240VAC
/N99/1.C
-XH 16
A2 X1
E Z1/2 7
+LVD E
-H24
X2
AMBER
-XH 8 -XH 9 -XH 10 -XH 11
5 9 /X02/7.E
1
6 10
2
7 11
3
8 12
4
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S INCOMING PANELS =J1.1 SCALE: 1: 1
CUSTOMER: AC VOLTAGE SUPPLY CIRCUITS START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J01+WLV/G02
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M01
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
-VD4 CN
DOC. No: 1YH8122104 -GND
-XDB 19 30 1 -XDB 12 26 32 37 34 7 6 8 41 20 15 16 43 39 29 -XDB 48 45 11 10 13 51
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
/M04/4.C
/M04/2.C
/M04/8.C
/M08/4.B
/M08/4.B
/M06/1.B
/M06/2.B
/M06/4.B
/M04/5.E
/M04/1.E
/M04/1.E
/M04/5.E
/M04/5.E
/X03/1.D
/X03/3.D
/X03/2.D
/X03/3.D
/X03/4.D
/G01/5.E
/X02/8.B
/X01/4.E
/X02/3.E
/X02/3.E
/X01/4.E
A A
-XB
+CB 24 26 25 4 5 32 27 2 31 41 23 8 11 6 29 28 9 7 1 40 52 12 49 10 57 55
-QB
CB DISCHARGED
CB CHARGED
CB OPENED
CB CLOSED
B -BS2 -BS1 B
4 2 2
-BT2
3 1 0 I 13 23 33 43 53
1
POSITION
SERVICE
-BT1 13 23 33 43 53
C 14 24 34 44 54 C
POSITION
TEST
-RL1 -MC -MO1
D -XB 34 36 35 20 14 15 42 13 37 3 30 33 18 22 21 16 39 38 19 17 50 51 53 54 47 48 58 56 D
/M08/4.C
/X03/1.E
/G01/5.E
/M04/5.E
/M04/5.E
/X01/4.F
/X02/3.E
/X03/2.E
/X03/3.E
/X03/2.E
/M04/1.E
/X02/3.E
/M08/5.C
/M08/4.C
/M06/1.C
/M06/2.C
/X03/3.E
/X01/4.F
/M06/4.C
/M04/8.C
/X03/4.E
/M04/4.D
/M04/2.D
/X02/8.B
-XDB 21 31 2 -XDB 4 5 27 33 36 38 35 3 9 42 23 22 17 18 44 40 28 -XDB 24 25 49 50 47 46 14 52
DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK EARTHING SWITCH MECHANICAL INTERLOCK WITH CB.-TRUCK
E RL1 CLOSING BLOCK MAGNET BS1 SPRING CHARGING MOTOR CONTACT BT2 LIMIT SWITCH (TEST POSITION) a) C.B. TRUNCK IN TEST-POSITION: EARTHING SWITCH CAN BE OPERATED
E
MO1 FIRST OPENING RELEASE BS2 SPRING CHARGED/DISCHARGED CONTACT BT1 LIMIT SWITCH (SERVICE POSITION) b) EARTHING SWITCH OPEN-POSITION: C.B.-TRUCK CAN BE MOVED
MC CLOSING RELEASE BB1-3 C.B. AUXILIARY SWITCH XB 58 POLE SOCKET INTO SERVICE-POSITION
MS SPRING CHARGING MOTOR XB2..11 CB. INTERNAL POLE PLUG/SOCKET
MU UNDERVOLTAGE RELEASE OPTION
RL2 TRUCK RACK BLOCKING MAGNET OPTION
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: -VACUUM C.B. TRUNK IN SERVICE POSITION -VACUUM CIRCUIT BREAKER OPEN -C.B. SPRING DISCHARGED
CODE: -QB PN: VD4/P -Z - W NAME: VACUUM CIRCUIT BREAKER TYPE: VD4 FUNCTION: NON-STANDARD SECONDARY CONTROL WIRING (7NO-7NC) TECHNICAL DATA: REFER TO SINGLE LINE DIAGRAM
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S INCOMING PANELS =J1.1 SCALE: 1: 1
CUSTOMER: VD4 INTERNAL WIRING START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J01+WLV/M01
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M02
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
L1 L2 L3
+CCB-QE
/M06/3.C
/M04/5.C
/X03/3.B
/X03/1.B
/X01/5.E
20 22 24 26 28
-BE1
21 23 25 27 29
/M06/4.C
/M04/8.E
/X03/2.B
/X03/2.B
/X03/2.B
/X01/5.E
B B
G 40 42 44 46 48
-BE2
-RL3
H 41 43 45 47 49
C C
D D
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: EARTHING SWITCH OFF AND CRANK NOT INSERTED
CODE: -QE PN: NAME: EARTHING SWITCH TYPE: FUNCTION: STANDARD SECONDARY CONTROL WIRING (5NO-5NC) TECHNICAL DATA: REFER TO SINGLE LINE DIAGRAM
50BF ARC TRIP REMOTE LOCAL PROTECTION TRIP REMOTE LOCAL CLOSE COMMAND VOL. IND. BLOCKING COIL
FROM VT
+
B /N01/1.A B
BROWN
ES OPENED
/M01/4.A 22
+CB -XB 28 -XB 23 -QE
+CB -BE1
-QB -QB /M02/5.B 23
-XB 58
31 /M01/8.D
21
-BB3 -BB2 -XC2 2 -XDB 14
32 CB OPENED 22 LOCKOUT TB1 1
+LVD NO
D -XB 38 -XB 33 -AR30 BO5 +LVD D
/N99/8.A
/N99/8.A
/M01/5.D /M01/4.D /N01/1.A
-PU
-XDB 44 TB1 2 /A01/6.C
-XDB 9
P3 P1
-XDB 7 -XDB 6 -XDB 10 -XDB 11 -XDB 12 +LVD
220V 110V
-PU
/M01/4.A /M01/4.A /M01/8.A /M01/8.A COM
/A01/6.C
+CB -XB 31 41
+CB -XB 10 49 /M01/3.A
-XC2 21
-QB -QB +CB -XB 4
13 43 43 -QB
-BB2 -BT1 -BT2 0V
E 14 44 44 +CCB E
-MC P2
CB CLOSING RELEASE -QE
/N99/8.A
CB FIRST OPENING CB CLOSING /M02/3.A G
-MO1 -RL1
RELEASE BLOCKING MAGNET -RL3
H
-XB 30 -XB 20 -XB 14
/M01/4.D /M01/2.D /M01/3.D
-XDB 3 -XDB 4 -XDB 5
A A
M04/4.B / CB LOCK+
B B
C C
XI6 8
XI6 8
D D
E E
M04/4.C / CB LOCK-
CB OPENED CB CLOSED CB OPENED CB CLOSED ES OPENED ES CLOSED CB IN TEST 50BF ARC TRIP SIGNAL GATHERING
A =PREV =NEXT A
-XI1 17 -XI1 31 -XI1 17
-XI1 32 -XI1 34
-L1+
/M04/8.A -XK1 5 -XK1 6
-XDB 15 -XDB 16 -XDB 45
B B
-XC2 13 -XC2 14
C C
-XB 16 -XB 39 -XB 47 -XK1 14
/M01/5.D /M01/5.D /M01/7.D
-XK1 10
D -XK1 11 D
-XK1 12
-XK1 13
-L1- -XK1 9
/M04/8.F
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S INCOMING PANELS =J1.1 SCALE: 1: 1
CUSTOMER: INDICATORS CIRCUIT START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J01+WLV/M06
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M08
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
PROTECTION AND CONTROL UNIT BINANY INPUT
CONTROL MODE SPARE CB SPRING STATUS CB STATUS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
-DC_L3+
/G01/3.E -XK2 1 -XK2 2 -XK2 3
-XDB 19 -XDB 20
/M01/1.A /M01/5.A
B B
-XB
+CB 24 -XB 11
-QB
11 4 53 41
1 2
-BS2 -BB2
+LVD 12 3 54 42
-SS1
REMOTE
/N99/3.B -XB 34 -XB 21 22
/M01/1.D /M01/5.D /M01/5.D
C C
-XK2 4
-XDB 21 -XDB 22 -XDB 23
-GND
D D
-TB2 12 13 TB3 15 17 18 19 20
+LVD + ++
-AR30
+
+
/N01/1.A
BI2 BI3 BI4 BI5 BI6
- - - - -
--
-TB2 14 TB3 16 22
E E
-XK2 5
-DC_L3-
/G01/4.E
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S INCOMING PANELS =J1.1 SCALE: 1: 1
CUSTOMER: RELAY INPUT SIGNALS START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J01+WLV/M08
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: N01
1 2 3 4 5 6 7 8
F
E
C
A
D
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A
REV.
1
1
DESCRIPTION
VOLTAGE L1 /A03/3.E -TB2 1
(-) /A03/3.F 2
IL1
2
2
VOLTAGE L2 /A03/4.E 3
(-) /A03/4.F 4
IL2
VOLTAGE L3 /A03/5.E 5
(-) /A03/5.F 6
IL3
VOLTAGE N /A03/5.F 7
(-) /A03/5.E 8
IE
9
10
11
GND /M08/2.D 12
+
+ /M08/2.D 13
- Uaux
- /M08/2.E 14
3
3
DATE
23/08/17
BIO MODULE
OUTPUT 1 (CB CLOSE) /M04/7.B TB3 1
/M04/7.B 2
BO1*
OUTPUT 2 (CB TRIP) /M04/3.B 3
BO2*
CUSTOMER:
/M04/3.B 4
OUTPUT 3 /M06/6.B 5
PROJECT TITLE:
/M06/6.C 6
BO3*
DESIGNED: HANG
OUTPUT 4 /X01/7.C 7
/X01/7.C 8
BO4*
RELAY FAIL (NC) /X01/5.C 9
4
4
/X01/5.C 10
11
12
BINARY INPUT 1 (INCLUDE TCS) (+) /M04/4.B 13
(-) /M04/4.B 14
BI1
BINARY INPUT 2 (INCLUDE TCS)(+) /M08/3.D 15
(-) /M08/3.E 16
BI2
SEE
BI3
BINARY INPUT 4 /M08/4.D 18 BI4
BINARY INPUT 5 /M08/4.D 19 BI5
BINARY INPUT 6 /M08/5.D 20 BI6
COM /M08/3.E 22
APPROVED:
5
5
BIO MODULE
OUTPUT 5 /M04/5.D TB1 1
/M04/5.D 2
BO5
OUTPUT 6 /X02/2.B 3
/X02/2.B 4
BO6
OUTPUT 7 /X01/6.C 5
/X01/6.C 6
BO7*
OUTPUT 8 /X01/6.C 7
DRAWING TITLE:
/X01/6.C 8
BO8*
6
6
TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559
7
7
8
8
SCALE:
LANGUAGE:
==SWG1=J01+WLV/N01
ENG
N99
START: 23/08/2017
1: 1
F
E
C
A
D
1 2 3 4 5 6 7 8
/M04/8.D
/M04/7.D
/M04/7.D
/M04/8.E
/M04/7.E
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
NO COM NC P1 P2 P3
+LVD-SS1 +LVD-SS5 +LVD 110V 0V 220V
CONTROL FAN MODE -PU
AUXILIARY VOLTAGE
1 2 1 2
1 3 5 7 9 11 1 3 5 7 VOLTAGE INDICATOR
2 4 6 8 10 12 2 4 6 8
/M04/3.A
/M04/2.A
/M04/6.A
/M04/5.A
/X01/6.E
/G02/5.C
/M08/3.B
NORMAL HANDLE
NORMAL HANDLE
B B
1 LOCAL 1 OFF
2 REMOTE 2 ON
C C
-GND /G02/7.D
/G02/5.E
/G02/7.D
/G02/7.D
/G02/5.D
/G02/5.D
/G02/7.C
Z1/1 2
+CB GND A1 A2 15 2 8
-EF Z1/1 1 1 -BR -KT
2 3 CURRENT RELAY TIMER RELAY
SUPPLY VOLTAGE
x1 U1 Z2 S231
MONITORED CURRENT CIRCUIT
D -VR D
x2 Z1 U2
5-100mA
0.5-10A
0.05-1A
COM
1
Z1/2 2 3
M Y1 Y2 Y3 Y4 16 18 7 5 6
FAN FOR VCB
Z1/2 1
/A03/3.C
/A03/3.C
/A03/3.C
/A03/4.C
/G02/5.E
/A03/3.D
/G02/5.D
/G02/5.D
/G02/6.D
/G02/7.D
/G02/5.E
/G02/7.E
E E
A =PREV =NEXT A
/M01/3.A /M01/6.A
-XB 5 -XB 7 +CCB
+CB -QE
E -QB /M02/3.A E
44 28 9
13 53 +LVD 1 2
-BE2 -BE1
-BB1 -BB3 -SS1
45 29 10
14 54 /N99/3.B
-XB 15 -XB 17
/M01/3.D /M01/6.D
-XDB 27 -XDB 28 -XC2 7 -XC2 8
XC1 7
ARC TRIP 50BF 50BF 50BF 50BF 50BF 50BF 50BF 50BF ARC TRIP TO SECTION PANEL CB IN TEST
A A
-XI1 9 -XI1 11 -XI1 13 -XI1 15 -XI1 17 -XI1 19 -XI1 21 -XI1 23 -XI1 25 =PREV =NEXT -XI3 1
BLACK
3 -XB 53
-KBP /M01/7.D
-XC4 3 -XC4 4 /M06/8.E 4
-XDB 49
C -XI1 10 -XI1 12 -XI1 14 -XI1 16 -XI1 18 -XI1 20 -XI1 22 -XI1 24 -XI1 26 -XI3 2 C
D XI6 7 XI6 9
-XH 17 D
-XDB 32 -XDB 41
/M01/3.A /M01/5.A
+CB -XB 32 -XB 8
-QB
/M01/1.A 1 5
21 31 -KBR
E -BB1 -BB2 /G02/6.E 9 E
22 32
-XB 42 -XB 18
/M01/3.D /M01/5.D
-XDB 33 -XDB 42
-XH 18
XI6 8 XI6 10
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S INCOMING PANELS =J1.1 SCALE: 1: 1
CUSTOMER: SIGNALS FOR INTERLOCKING AND INTERTRIPPING START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J01+WLV/X02
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: X03
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted. EARTHING SWITCH SPARE CONTACT
A A
-XC2 3 -XC2 9 -XC2 11 -XC2 17 -XC2 18 -XC2 23 -XC2 25 -XC2 27 -XC2 29
+CCB
-QE
/M02/3.A 26 46 48 42 24 1 3 5 13
B -BE1 -BE2 -BE2 -BE2 -BE1 -KESO -KESO -KESO -KESO B
/M02/6.B 27 /M02/6.B 47 /M02/6.B /M02/5.B 43 /M02/5.B 25 /M06/6.E 2 /M06/6.E 4 /M06/6.E 6 /M06/6.E 14
49
CB SPRING
CB CLOSED CB OPENED CB CLOSED CB CLOSED CB IN SERVICE CB IN TEST CB IN TEST CB IN TEST CB IN TEST CB OPENED CB OPENED CB OPENED CB OPENED
DISCHARGED
D D
-XDB 30 -XDB 34 -XDB 37 -XDB 39 -XDB 51 -XC3 1 -XC3 3 -XC3 5 -XC3 7 -XC3 9 -XC3 11 -XC3 13 -XC3 15
-QB
2 53 31 43 41 53 1 3 5 13 1 3 5 13
-BS2 -BB1 -BB1 -BB3 -BT1 -KCBT -KCBT -KCBT -KCBT -KCBO -KCBO -KCBO -KCBO
/M06/4.E 2 /M06/4.E 4 /M06/4.E 6 /M06/4.E 14 /M06/5.E 2 /M06/5.E 4 /M06/5.E 6 /M06/5.E 14
1 54 32 44 42 54
E E
-XDB 31 -XDB 35 -XDB 36 -XDB 38 -XDB 40 -XDB 52 -XC3 2 -XC3 4 -XC3 6 -XC3 8 -XC3 10 -XC3 12 -XC3 14 -XC3 16
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
E E
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
E FB3 S203-C6 MINIATURE CIRCUIT 2CDS253001R0064 1 ABB 3 POLES, 440VAC MAX., 6A, 6kA, C TRIPPING CURVE E
BREAKER
FB3 AUX. CONTACT S2C-H11L 2CDS200936R0001 1 ABB CONTACTS: 1NO+1NC; FOR MCB S200 SERIES
S2C-H11L
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
S101 V15F-070C Door Limit Switch 1YUZ500019A0006 1 KACON Door Limit switch
A Type: V15F-070C A
CONTACTS: 1 CHANGE-OVER
Manufacturer: Kacon
B B
C C
D D
E E
Y
A B A
+LVD
-PU
B 1 B
R:L1
1
Y:L2
1
B:L3
C C
E:PE
-GND
+CB
D -VT -FF -BV D
L1 A N n a -XU15 8
L2 2A -XU15 10
L3 2A -XU15 20
2A -XU15 21
E E
A A
+CB 1n 1n 1n
-VT
1a 1a 1a
-XU15
21 20 10 8
B B
-XV1 15 14 13 12
5 3 1 13 21
-FB3
S203-C6
6A 6 4 2 14 22
/X01/3.C
/M06/5.B
-XV1 11 10 9
C C
+LVD-PM +LVD +LVD
/N99/3.A VOLTAGE TEST -AR81
Elite 448 TERMINAL 7 5 3 1 -AR27
/N01/1.A /N02/1.A
VOLTAGE INPUTS
+LVD BK BU YE RD
-XMV1
VA N VB N VC N VA N VB N VC N
BK BU YE RD -TB2 1 2 3 4 5 6 -TB2 1 2 3 4 5 6
V1 V2 V3 VN 8 6 4 2
D D
=PREV
E E
-XV1 1 =NEXT
-XV1 3 -XV1 1
-XV1 1
-XV1 5 -XV1 3
-XV1 3
-XV1 7 -XV1 5
7
-XV1 5
-XV1 -XV1 7
110V DC
B B
110V DC 110V DC
-XJ 2 -XJ 4
C C
1 3 12 14
-FB1
S202-C6 2 4 11
6A
/X01/2.C
D D
E E
-DC_L3+
-DC_L3-
/M06/1.A
/M06/1.F
A A
PREVIOUS NEXT PANEL
PANEL
B B
220V AC, 50Hz -XH 2 -XH 4 220V AC, 50Hz
1 3 12 14
-FB2
S202-C6 2 4 11
6A
C
/X01/2.C
COM
-S101
D NC D
A1
1 1 X1
-EL +CCF +CB +LVD
E 220-240VAC -EH2 -EH1 -H20 E
2 2 X2
A2 100W 50W WHITE
Y/Y0
/M06/6.B
/M06/4.B
/X03/3.E
/X03/4.E
/X03/5.E
/X03/6.E
A A
+CB -XU15 56 52 49 57 L1 L2 L3 26 5
-VT
1 3
-BF1
-XU 1 4 2 7 2 4
-FF 1 3
B -BF2 B
-BT2
13 23 33 43 53 A A A 2 4
-BV
14 24 34 44 54 E
N N N
1 3
-XU 6 5 -BF3
POSITION
SERVICE
2 4
-BT1 13 23
n n n
14 24
C a a a C
-XU 13 11 17
POSITION
TEST
-XU 16 15 -XU 3 8
33 43 53
34 44 54
-X 14 12 18
D -XU15 50 51 53 54 55 58 8 10 20 21 25 4 D
/M06/6.C
/M06/6.C
/X03/3.E
/X03/3.E
/X03/4.E
/X03/5.E
/X03/6.E
/M06/4.C
/A02/4.B
/A02/4.B
/A02/3.B
/A02/3.B
VOLTAGE TRANSFOMER TRUCK VOLTAGE TRANSFOMER TRUCK
E E
DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK
FF HIGH VOLTAGE FUSE BT2 LIMIT SWITCH (TEST POSITION)
XU15 58 POLE PLUG/SOCKET BT1 LIMIT SWITCH (SERVICE POSITION)
BV VOLTAGE TRANSFORMER E EARTHING CONNECTION WIRE
FB60 MINI-CIRCUIT BREAKER OPTION
MU UNDERVOLTAGE RELEASE
BF FUSE BLOWN IND. CONTACT
F INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: -VT TRUNK IN SERVICE POSITION F
PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S VT PANELS=J1.2 SCALE: 1: 1
CUSTOMER: VT TRUCK INTERNAL WIRING START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J02+WLV/M01
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M06
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
PROTECTION AND CONTROL UNIT BINANY INPUT
POWER FOR RELAY VT TRUCK POSITION
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
DPM AUXILIARY SUPPLY 110V DC FUSE BLOWN WD1 VT MCB ON TEST POSITION SERVICE POSITION
A A
-DC_L3+ -L3+ /
/G01/2.E M08/1.A
-XK2 1 -XK2 2 -XK2 3 -XK2 4 -XK2 5
-XC3 12
-XC3 10
/M01/2.A
B /M01/8.A B
+CB -XU15 56
+CB -XU15 5
-VT
-VT
13 13 13
3
-BT2 -BT1
-BF -FB3 14 14 14
4 /A02/3.B
-XU15 50 51
-XU15 4
/M01/2.D /M01/2.D
/M01/8.D
C C
+
/N99/3.A /N01/1.A /N01/1.A
D BI1 BI2 BI3 BI4 BI5 BI6 D
-PS - - - - - -
--
-/N TB2 14 TB3 14 16 22
E E
L3- /
M08/1.F
-XK2 10 -XK2 11
-DC_L3-
/G01/2.E
A A
-L3+ -L3+ /
/M06/8.A M10/3.A
-XK2 6 -XK2 7 -XK2 8 -XK2 9
B B
C C
TB2 12 13 TB3 13 15 17 18 19 20
+LVD + + +LVD
+
D -AR81 -AR81 D
+
+
/N02/1.A /N02/1.A
BI1 BI2 BI3 BI4 BI5 BI6
- - - - - -
--
TB2 14 TB3 14 16 22
E E
-L3- L3- /
/M06/8.E M10/3.B
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S VT PANELS=J1.2 SCALE: 1: 1
CUSTOMER: RELAY INPUT SIGNAL START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J02+WLV/M08
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M10
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
LOAD SHEDDING CIRCUIT
5 STAGE LOAD SHEDDING
STAGE 1 STAGE 2 STAGE 3 STAGE 4
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
L3+
/M08/6.A XI5 11
L3-
/M08/6.F
B B
TB1 1 TB1 3 TB1 5 TB1 7
+LVD
-AR81 BO5 BO6 BO7 BO8
/N02/1.A
D D
-XI5 5 XI5 5 -XI5 5
D
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A
REV.
1
1
DESCRIPTION
ISSUED FOR APROVAL
GRE130-412
ANALOG INPUT MODULE
VOLTAGE L1 /A02/5.D -TB2 1
(-) /A02/5.D 2
VL1
VOLTAGE L2 /A02/5.D 3
VL2
2
2
(-) /A02/5.D 4
VOLTAGE L3 /A02/6.D 5
DATE
(-) /A02/6.D 6
VL3
23/08/17
VOLTAGE N 7
(-) 8
VE
9
10
11
GND /M06/3.D 12
PROJECT TITLE:
+
+ /M06/4.D 13
- Uaux
- /M06/4.D 14
3
3
BIO MODULE
OUTPUT 1 (CB CLOSE) /X03/1.B TB3 1
/X03/1.B 2
BO1*
DESIGNED:
APPROVED:
CUSTOMER:
11
4
4
DRAWING NO.:
12
BINARY INPUT 1 (INCLUDE TCS) (+) /M06/4.D 13
(-) /M06/4.D 14
BI1
BINARY INPUT 2 (INCLUDE TCS)(+) /M06/5.D 15
(-) /M06/5.D 16
BI2
BINARY INPUT 3 /M06/6.D 17 BI3
BINARY INPUT 4 /M06/6.D 18 BI4
SEE
BINARY INPUT 5 /M06/7.D 19 BI5
1YUX20000A0062
BINARY INPUT 6 /M06/8.D 20 BI6
CHECKED:
5
5
NINH NV
HANG PTD
BIO MODULE
OUTPUT 5 /X02/6.E TB1 1
/X02/6.E 2
BO5
DRAWING TITLE:
OUTPUT 6 /X02/7.E 3
BO6
VT PANELS=J1.2
/X02/7.E 4
6
6
OUTPUT 7 /X03/3.B 5
/X03/3.B 6
BO7*
OUTPUT 8 /X03/3.B 7
/X03/3.B 8
BO8*
GRE130 - A/I + Binary I/O Board
TEL: (+84) (241) 3748 530, TELEFAX: (+84) (241) 3748 531
7
7
CONT.:
SHEET:
ABB VIETNAM MANUFACTURING
8
8
SCALE:
LANGUAGE:
==SWG1=J02+WLV/N01
ENG
N02
DATE: 23/08/2017
1: 1
F
E
C
A
D
F
E
C
A
D
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A
REV.
1
1
DESCRIPTION
ISSUED FOR APROVAL
GRE130-412
ANALOG INPUT MODULE
VOLTAGE L1 /A02/6.D -TB2 1
(-) /A02/7.D 2
VL1
VOLTAGE L2 /A02/7.D 3
VL2
2
2
(-) /A02/7.D 4
VOLTAGE L3 /A02/7.D 5
DATE
(-) /A02/7.D 6
VL3
23/08/17
VOLTAGE N 7
(-) 8
VE
9
10
11
GND /M08/1.D 12
PROJECT TITLE:
+
+ /M08/1.D 13
- Uaux
- /M08/1.D 14
3
3
BIO MODULE
OUTPUT 1 (CB CLOSE) /X03/6.B TB3 1
/X03/6.B 2
BO1*
DESIGNED:
APPROVED:
CUSTOMER:
11
4
4
DRAWING NO.:
12
BINARY INPUT 1 (INCLUDE TCS) (+) /M08/2.D 13
(-) /M08/2.D 14
BI1
BINARY INPUT 2 (INCLUDE TCS)(+) /M08/3.D 15
(-) /M08/3.D 16
BI2
BINARY INPUT 3 /M08/3.D 17 BI3
BINARY INPUT 4 /M08/4.D 18 BI4
SEE
BINARY INPUT 5 /M08/5.D 19 BI5
1YUX20000A0062
BINARY INPUT 6 /M08/5.D 20 BI6
CHECKED:
5
5
NINH NV
HANG PTD
BIO MODULE
OUTPUT 5 /M10/3.B TB1 1
/M10/3.C 2
BO5
DRAWING TITLE:
OUTPUT 6 /M10/4.B 3
BO6
VT PANELS=J1.2
/M10/4.C 4
6
6
OUTPUT 7 /M10/5.B 5
/M10/5.C 6
BO7*
OUTPUT 8 /M10/5.B 7
/M10/5.C 8
BO8*
GRE130 - A/I + Binary I/O Board
TEL: (+84) (241) 3748 530, TELEFAX: (+84) (241) 3748 531
7
7
CONT.:
SHEET:
ABB VIETNAM MANUFACTURING
8
8
SCALE:
LANGUAGE:
==SWG1=J02+WLV/N02
ENG
N99
DATE: 23/08/2017
1: 1
F
E
C
A
D
1 2 3 4 5 6 7 8
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
/M06/2.D
/M06/2.D
A A
+ - SG -/N +/P
+LVD - + Elite 448
-PM
RS485 POWER SUPPLY
COMMUNICATION PORT (AC/DC SUPPLY)
/A02/2.D
/A02/2.D
/A02/2.D
/A02/2.D
C C
D D
E E
MCB OFF MCB OFF FAULTY LOAD SHEDDING 27/59 OPERATED TERMINALS
A =PREV =NEXT A
-XI4 10 -XI4 20
-XI4 6 -XI4 8 -XI4 12 -XI4 14 -XI4 16 -XI4 18 -XI4 22
D D
E E
A A
B B
C C
27/59 59
D D
-XI1 1 -XI1 3
TB1 1 TB1 3
+LVD
-AR27 BO5 BO6
/N01/1.A
TB1 2 TB1 4
E E
-XI1 2 -XI1 4
A A
-XR1 4 -XR1 6 -XR1 8 -XR1 10 -XR1 12 -XR2 7 -XR2 9 -XR2 11
VT SPARE CONTACT
TEST POSITION SERVICE POSITION TEST POSITION TEST POSITION FUSE NORMAL
-VT
23 23 33 53 1
-BT2 -BT1 -BT2 -BT2 -BF
E 24 24 34 54 2 E
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
PM Elite 448 INTEGRA DIGITAL POWER 1YUX500006B0098 1 CEWE LCD DISPLAY SUPPLY BY CUSTOMER
A SYSTEM 3-phase 3/4-wire A
Frequency: 50/60Hz
Volt input: 57.7-240VAC 3Φ4W/3Φ3W
Current input_ Ib:1-5A, Imax: 200% of Ib
Aux voltage: 80-300V ac/dc
Communication: RS485 interface Modbus
PU DXN-Q-1 CAPACITIVE VOLTAGE SUPPLY BY CNABB 1 LEELEN LED INDICATOR, AC/DC 80~250V, LOCK RELAY WITH 1CO
INDICATOR
SOC YW1L-MF2E11QHG ILLUMINATED PUSH BUTTON 1YUX500009B0001 1 IDEC 22mm DIAMETER CUTOUT, LENS: GREEN, ILLUMINATION: LED
TYPE, FULL SHROUD, 110V AC/DC, 1NO + 1NC CONTACTS
B SOT YW1L-MF2E11QHR ILLUMINATED PUSH BUTTON 1YUX500009B0002 1 IDEC 22mm DIAMETER CUTOUT, LENS: RED, ILLUMINATION: LED B
TYPE, FULL SHROUD, 110V AC/DC, 1NO + 1NC CONTACTS
SS1 M220-61639-003M1 2-POSTION SELECTOR 1YUX500008B0004 1 SALZER 3 POLES, Ith: 20A, SIZE: 48x48mm²
SWITCH LEGEND: CONTROL, LABEL: LOCAL/REMOTE
SS3 M220-61639-S001.D 2-POSTION SELECTOR 1YUX500008B0019 1 SALZER 3 POLES, Ith: 20A, SIZE: 48x48mm², w/key switch
SWITCH LEGEND: AUTO RECLOSE, LABEL: OFF/ON
SS4 M220-61061-S001D 5-POSTION KEYSWITCH 1YUX500008B0007 1 SALZER 1 POLE, Ith: 20A, SIZE: 48x48mm², w/key switch
LEGEND: LOAD SHEDDING, LABEL: OFF/F1/F2/F3/F4
XMA1 KTT-04S TEST TERMINAL 1YUX500011B0001 1 KACON 4 POLES, PLUSH MOUTED
C C
BP1...BP3 FAULT LIMITER SUPPLY BY CNABB 3 XIAMEN PEAKS Ith LIMITER
CONTACTS: 1 CHANGE-OVER
EL LIGHTING LAMP FOR 1YUX500009B0045 1 LOCAL Lighting lamp for LV compartment
UNIGEAR LED TYPE
1.2W, 110-230VAC/DC
c/w PLASTIC HOLDER
FB1...FB4 S202-C6 MINIATURE CIRCUIT 2CDS252001R0064 4 ABB 2 POLES, 440VAC/125VDC MAX., 6A, 6kA, C TRIPPING CURVE
BREAKER
FB1...FB4 AUX. CONTACT S2C-H6R AUXILIARY CONTACTS 2CDS200912R0001 4 ABB CONTACTS: 1CHANGE OVER CONTACT; FOR MCB S200 SERIES
D D
K81;KBF BC6-30-10 MINI CONTACTOR RELAY GJL1213001R0104 2 ABB VOLTAGE: 110-125VDC, CONTACTS: 3NO+1NO
S101 V15F-070C Door Limit Switch 1YUZ500019A0006 1 KACON Door Limit switch
Type: V15F-070C
CONTACTS: 1 CHANGE-OVER
Manufacturer: Kacon
E E
Y
A B A
+CB-QB
VD4/P
1250A
+CCB +CCB +CCB
-BC1 -BC2 -BC3
P1 P1 P1
3x400-800/1/1A
B B
CORE1: CL0.5Fs10
15VA@400/1A
TO SHEET A02
15VA@800/1A
CORE2:CL5P20
15VA@400/1A
TO SHEET A03
15VA@800/1A
C C
P2 P2 P2
+LVD
-PU
1
R:L1
1
Y:L2
D D
1
B:L3
E:PE
-QE -GND
E E
L1 L2 L3
3x400-800/1/1A
CORE1: CL0.5Fs10 , 15VA@400/1A , 15VA@800/1A
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A -GND A
METAL JUMPER
D D
-XA1 12 -XA1 13
I1.S1 I1.S2 I2.S1 I2.S2 I3.S1 I3.S2 1 3 4 6 7 9
E E
+LVD-PM IL1 IL2 IL3 +LVD-PJ L1 COM L2 COM L3 COM
/N99/5.D CURRENT INPUTS /N99/5.B IL1 IL2 IL3
A1700 CURRENT INPUTS
Elite 448
3x400-800/1/1A
CORE2:CL5P20 , 15VA@400/1A , 15VA@800/1A
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A -GND A
METAL JUMPER
C C
1 RD 3 YE 5 BU 7 BK
+LVD-XMA1 L1 L2 L3 N
D D
L1 L2 L3 N
2 RD 4 YE 6 BU 8 BK
+LVD -TB2 1 3 5 8
-AR30 IA IB IC N
/N01/1.A
E E
IA IB IC IE
N N N Ie
-TB2 2 4 6 7
-XA2 12 -XA2 13
VOLTAGE CIRCUIT
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
+LVD-PM +LVD-PJ
/N99/5.D /N99/5.B
Elite 448 A1700
VOLTAGE INPUTS
VOLTAGE INPUTS
U1 U2 U3 Uo
V1 V2 V3 VN 2 5 8 11
B B
C C
D D
-XV1 -XV1 -XV1 -XV1 =NEXT
2 4 6 8
=PREV -XV1 1
1 -XV1 3
-XV1 1 -XV1 3 -XV1 5
-XV1 3 -XV1 5 -XV1 7
-XV1 5 -XV1 7
-XV1 7 -XV1
E E
NEXT PANEL
PREVIOUS PANEL
B B
110V DC 110V DC
-XJ 2 -XJ 4
C C
1 3 12 14 1 3 12 14 1 3 12 14
-FB1 -FB2 -FB3
S202-C6 2 4 11 S202-C6 2 4 11 S202-C6 2 4 11
6A 6A 6A
/X01/2.C
/X01/2.C
/X01/3.C
D D
-XDB 1 -XDB 2
/M01/1.A
+CB -XB 25
-QB 2
-BS1
E 1 E
-MS M
-DC_L1+
-DC_L3+
-DC_L1-
-DC_L3-
/M04/1.A
/M07/1.A
/M04/1.F
/M07/1.F
-XB 35
/M01/1.D
A A
PREVIOUS NEXT PANEL
PANEL
B B
220V AC, 50Hz -XH 2 -XH 4
1 3 12 14
-FB4
S202-C6 2 4 11
6A
C
/X01/3.C
COM
-S101
D NC D
A1
1 1 X1
-EL +CCF +CB +LVD
E 220-240VAC -EH2 -EH1 -H20 E
2 2 X2
A2 100W 50W WHITE
-VD4 CN
DOC. No: 1YH8122104 -GND
-XDB 19 30 1 -XDB 12 26 32 37 34 7 6 8 41 20 15 16 43 39 29 -XDB 48 45 11 10 13 51
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
/M04/4.C
/M04/2.C
/M04/8.C
/M07/4.B
/M07/5.B
/M05/1.B
/M05/2.B
/M04/5.E
/M04/1.E
/M04/1.E
/M04/5.E
/M04/4.E
/X03/1.D
/X03/2.D
/X03/3.D
/X03/2.D
/X03/5.D
/X03/4.D
/X03/7.D
/X03/6.D
/X03/8.D
/G01/5.E
/X01/4.E
/X01/4.E
A A
-XB
+CB 24 26 25 4 5 32 27 2 31 41 23 8 11 6 29 28 9 7 1 40 52 12 49 10 57 55
-QB
CB DISCHARGED
CB CHARGED
CB OPENED
CB CLOSED
B -BS2 -BS1 B
4 2 2
-BT2
3 1 0 I 13 23 33 43 53
1
POSITION
SERVICE
-BT1 13 23 33 43 53
C 14 24 34 44 54 C
POSITION
TEST
-RL1 -MC -MO1
D -XB 34 36 35 20 14 15 42 13 37 3 30 33 18 22 21 16 39 38 19 17 50 51 53 54 47 48 58 56 D
/M07/4.C
/X03/1.E
/G01/5.E
/M04/4.E
/M04/5.E
/X01/4.F
/X03/2.E
/X03/3.E
/X03/3.E
/X03/2.E
/M04/1.E
/X03/5.E
/M07/5.C
/M07/5.C
/M05/1.C
/M05/2.C
/X03/4.E
/X01/4.F
/X03/7.E
/X03/8.E
/X03/6.E
/X03/6.E
/M04/8.C
/X03/8.E
/M04/4.D
/M04/2.D
-XDB 21 31 2 -XDB 4 5 27 33 36 38 35 3 9 42 23 22 17 18 44 40 28 -XDB 24 25 49 50 47 46 14 52
DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK EARTHING SWITCH MECHANICAL INTERLOCK WITH CB.-TRUCK
E RL1 CLOSING BLOCK MAGNET BS1 SPRING CHARGING MOTOR CONTACT BT2 LIMIT SWITCH (TEST POSITION) a) C.B. TRUNCK IN TEST-POSITION: EARTHING SWITCH CAN BE OPERATED
E
MO1 FIRST OPENING RELEASE BS2 SPRING CHARGED/DISCHARGED CONTACT BT1 LIMIT SWITCH (SERVICE POSITION) b) EARTHING SWITCH OPEN-POSITION: C.B.-TRUCK CAN BE MOVED
MC CLOSING RELEASE BB1-3 C.B. AUXILIARY SWITCH XB 58 POLE SOCKET INTO SERVICE-POSITION
MS SPRING CHARGING MOTOR XB2..11 CB. INTERNAL POLE PLUG/SOCKET
MU UNDERVOLTAGE RELEASE OPTION
RL2 TRUCK RACK BLOCKING MAGNET OPTION
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: -VACUUM C.B. TRUNK IN SERVICE POSITION -VACUUM CIRCUIT BREAKER OPEN -C.B. SPRING DISCHARGED
CODE: -QB PN: VD4/P -Z - W NAME: VACUUM CIRCUIT BREAKER TYPE: VD4 FUNCTION: NON-STANDARD SECONDARY CONTROL WIRING (7NO-7NC) TECHNICAL DATA: REFER TO SINGLE LINE DIAGRAM
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S OUTGOING PANELS = J1.5~J1.9 SCALE: 1: 1
CUSTOMER: VD4 INTERNAL WIRING START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J03+WLV/M01
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M02
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
L1 L2 L3
+CCB-QE
/M04/4.C
/M05/5.B
/X03/3.B
/X03/1.B
/X01/5.E
20 22 24 26 28
-BE1
21 23 25 27 29
/M05/5.B
/M04/8.E
/X03/2.B
/X03/2.B
/X03/2.B
/X01/5.E
B B
G 40 42 44 46 48
-BE2
-RL3
H 41 43 45 47 49
C C
D D
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: EARTHING SWITCH OFF AND CRANK NOT INSERTED
CODE: -QE PN: NAME: EARTHING SWITCH TYPE: FUNCTION: STANDARD SECONDARY CONTROL WIRING (5NO-5NC) TECHNICAL DATA: REFER TO SINGLE LINE DIAGRAM
50BF TRIP ARC TRIP 50BF TRIP SPARE REMOTE LOCAL PROTECTION TRIP AUTORECLOSE REMOTE LOCAL CLOSE COMMAND VOL. IND. BLOCKING COIL
A -DC_L1+ -L1+ / A
/G01/2.E -XK1 1 -XK1 2 -XK1 3 M05/1.A
XI2 1
-JUMPER
3 1 XI3 3
1 2 1 2
7 5
XI2 2 +LVD 1 2
+LVD 1 2
-JUMPER
+LVD 4 +LVD 2 -SS1 -SS1
8 6
-SS1 -SS1 REMOTE LOCAL
XI3 4
REMOTE LOCAL /N99/4.A /N99/3.A
/N99/3.A /N99/3.A TB3 3 TB3 13 XI2 3 XI3 5
+LVD TB3
XI1 1 -XC4 5 XI1 2 XI1 3 XI1 4 -JUMPER 1 -JUMPER
=OUT -AR30 XI2 5
BROWN
XI2 4 +LVD
+
/N01/1.A
B NC 1 BO2 BI1 -AR30 XI3 6 B
XI1 3 3 /N01/1.A
BO1
-BP1 -K81 -
+LVD TB1 3
C/M09/4.E 2
-AR30
-KBF +LVD 4 TB3 2
XC2 1 /N01/1.A BO6 +LVD 4
-SOT TB3 4 TB3 14
/M05/1.E -SOC
BLACK
ES OPENED
22
XI1 5 -XC4 6 XI1 6 XI1 7 XI1 8 -QE
-BE1 +CB -XB 57
/M02/5.B 23 XI2 6 XI2 7
-QB
C -XDB 43 /M01/1.A
C
53
/M01/5.A -XDB 8
XC2 2 -BT2
+CB -XB 28
/M01/4.A CB IN TEST 54
-QB +CB -XB 23
31 -QB
-XB 58
-BB3 21
32 -BB2 -XDB 14
CB OPENED 22
/N99/7.A
/N99/7.A
/M01/4.D -AR30 BO5 -PU
-XDB 44 /N01/1.A /A01/6.C
-XDB 9 P3 P1
TB1 2
+LVD 220V 110V
-XDB 7 -XDB 6 -XDB 10 -XDB 11 -XDB 12 -PU
COM
/A01/6.C
/M01/4.A /M01/4.A /M01/8.A /M01/8.A
XC2 21
+CB -XB 31 41
+CB -XB 10 49 /M01/3.A
-QB -QB +CB -XB 4
43 43
+CCB
13 -QB 0V -QE
E -BB2 -BT1 -BT2 /M02/3.A E
P2
14 44 44
/N99/7.A
-MC CB CLOSING RELEASE G
CB FIRST OPENING -RL3
-MO1 CB CLOSING -RL1
RELEASE BLOCKING MAGNET H
-XK1 7 -XK1 8
-DC_L1- -L1- /
/G01/2.E M05/1.F
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S OUTGOING PANELS = J1.5~J1.9 SCALE: 1: 1
CUSTOMER: CLOSING & TRIPPING CIRCUITS START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J03+WLV/M04
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M05
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
POSITION INDICATION
LAMP INDICATOR CIRCUIT BREAKER EARTHING SWITCH
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
-L1+
/M04/8.A -XK1 4 -XK1 5
-XDB 15 -XDB 16
-XC2 13 -XC2 14
/M01/5.A /M01/5.A
B B
+CB -XB 6 -XB 29
+CCB
-QB -QE
/M02/3.A 20 40
13 21 TB3
-BE1 -BE2 +LVD 5
-BB3 -BB3 -AR30
21 41
14 22 /N01/1.A BO3
C C
D D
1 2 /X02/4.C
3 4 /X02/4.C
5 6 /X01/6.C
2 3 13 14
2 3
X1 X1 A1
+LVD-SOT +LVD-SOC +LVD-P1 -KBF
/M04/3.B /M04/6.B
+LVD-P2
X2 X2 A2
RED GREEN 1
E 1 E
-XK1 9
-L1-
/M04/8.F
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S OUTGOING PANELS = J1.5~J1.9 SCALE: 1: 1
CUSTOMER: INDICATOR CIRCUIT & 50BF SIGNAL START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J03+WLV/M05
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M07
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
PROTECTION AND CONTROL UNIT BINANY INPUT
CB SPRING STATUS CB STATUS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
DPM AUXILIARY SUPPLY POWER FOR RELAY CONTROL MODE AUTORECLOSE ON CB SPRING CHARGED CB CLOSED CB OPENED
A A
-DC_L3+
/G01/3.E -XK2 1 -XK2 2 -XK2 3
-XDB 19 -XDB 20
/M01/1.A /M01/5.A
B B
-XB
+CB 24 -XB 11
-QB
11 3 4 53 41
1 2 1 2
-BS2 -BB2
+LVD 12 +LVD 4 3 54 42
-SS1 -SS3
REMOTE ON
/N99/4.A /N99/3.C -XB 34 -XB 21 22
/M01/1.D /M01/5.D /M01/5.D
C C
-GND
D D
+/P -TB2 12 13 TB3 15 17 18 19 20
+LVD +LVD + ++
-PM (AC/DC) -AR30
+
+
/N99/5.D /N01/1.A
-PS BI2 BI3 BI4 BI5 BI6
- - - - -
--
-/N -TB2 14 TB3 16 22
E E
-XK2 4 -XK2 5
-DC_L3-
/G01/4.E
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S OUTGOING PANELS = J1.5~J1.9 SCALE: 1: 1
CUSTOMER: RELAY INPUT SIGNALS START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J03+WLV/M07
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M09
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
LOAD SHEDDING CIRCUIT
A A
B B
+LVD-SS4
/N99/2.D
1
1 2 /M04/2.B
3 4
5 6
13 14
E E
A1
-K81
A2
D
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A
REV.
1
1
DESCRIPTION
VOLTAGE L1 /A03/3.E -TB2 1
(-) /A03/3.E 2
IL1
2
2
VOLTAGE L2 /A03/4.E 3
(-) /A03/4.E 4
IL2
VOLTAGE L3 /A03/5.E 5
(-) /A03/5.E 6
IL3
VOLTAGE N /A03/5.E 7
(-) /A03/5.E 8
IE
9
10
11
GND /M07/2.D 12
+
+ /M07/2.D 13
- Uaux
- /M07/2.E 14
3
3
DATE
23/08/17
BIO MODULE
OUTPUT 1 (CB CLOSE) /M04/7.B TB3 1
/M04/7.B 2
BO1*
OUTPUT 2 (CB TRIP) /M04/3.B 3
BO2*
CUSTOMER:
/M04/3.B 4
OUTPUT 3 /M05/6.B 5
PROJECT TITLE:
/M05/6.C 6
BO3*
DESIGNED: HANG
OUTPUT 4 /X01/7.C 7
/X01/7.C 8
BO4*
RELAY FAIL (NC) /X01/5.C 9
4
4
/X01/4.C 10
11
12
BINARY INPUT 1 (INCLUDE TCS) (+) /M04/4.B 13
(-) /M04/4.B 14
BI1
BINARY INPUT 2 (INCLUDE TCS)(+) /M07/3.D 15
(-) /M07/3.E 16
BI2
SEE
BI3
BINARY INPUT 4 /M07/4.D 18 BI4
BINARY INPUT 5 /M07/5.D 19 BI5
BINARY INPUT 6 /M07/5.D 20 BI6
COM /M07/3.E 22
APPROVED:
5
5
BIO MODULE
OUTPUT 5 /M04/4.D TB1 1
/M04/4.D 2
BO5
OUTPUT 6 /M04/5.B 3
/M04/5.B 4
BO6
OUTPUT 7 /X01/5.C 5
/X01/5.C 6
BO7*
OUTPUT 8 /X01/6.C 7
DRAWING TITLE:
/X01/6.C 8
BO8*
6
6
TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559
7
7
8
8
SCALE:
LANGUAGE:
==SWG1=J03+WLV/N01
ENG
N99
START: 23/08/2017
1: 1
F
E
C
A
D
1 2 3 4 5 6 7 8
/M04/8.D
/M04/8.D
/M04/7.D
/M04/7.D
/M04/7.E
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
+LVD-SS1
CONTROL NO COM NC P1 P2 P3
A A
+LVD 110V 0V 220V
1 2 -PU
1 3 5 7 9 11 AUXILIARY VOLTAGE
VOLTAGE INDICATOR
2 4 6 8 10 12
/M04/3.A
/M04/2.A
/M04/6.A
/M04/6.A
/X01/6.E
/M07/3.B
NORMAL HANDLE
1 LOCAL
B 2 REMOTE B
+LVD-PJ
+LVD-SS3
AUTO RECLOSE
AUTO RECLOSE ELSTER METER A1700
TARIFF METER
1 2 CURRENT INPUTS VOLTAGE INPUTS
1 3 5 7 IL1 IL2 IL3
OFF ON
L1 COM L2 COM L3 COM U1 U2 U3 Uo
C 2 4 6 8 C
1 3 4 6 7 9 2 5 8 11
/M07/3.B
/A02/5.E
/A02/5.E
/A02/6.E
/A02/6.E
/A02/6.E
/A02/7.E
/A04/4.B
/A04/4.B
/A04/5.B
/A04/5.B
SALZER 1 OFF
2 ON
/M07/1.D
/M07/1.E
D D
+LVD-SS4 + - SG -/N +/P
LOAD SHEDDING LOAD SHEDDING +LVD - + Elite 448
-PM
RS485 POWER SUPPLY
2 3 COMMUNICATION PORT (AC/DC SUPPLY)
OFF F1 1 3 5 7
1 4
F2 2 4 6 8
5 CURRENT INPUTS VOLTAGE INPUTS
IL1 IL2 IL3
F3
I1.S1 I1.S2 I2.S1 I2.S2 I3.S1 I3.S2 V1 V2 V3 VN
E F4 E
/A02/2.E
/A02/3.E
/A02/3.E
/A02/3.E
/A02/4.E
/A02/4.E
/A04/3.B
/A04/3.B
/A04/3.B
/A04/3.B
SALZER 1 OFF
2 F1
3 F2
4 F3
5 F4
FAULTY
MCB OFF SPARE TERMINALS
A =PREV =NEXT A
D D
/M01/3.A /M01/6.A
-XB 5 -XB 7 +CCB
+CB -QE
-QB /M02/3.A 9
E 44 28 +LVD 1 2
E
13 53 -SS1
-BE2 -BE1 10
-BB1 -BB3 /M02/5.B /N99/4.A
45 /M02/6.B 29 LOCAL
14 54
-XB 15 -XB 17
/M01/3.D /M01/6.D
A =PREV =NEXT A
BROWN
BROWN
NC NC
1 3 -BP2 -BP3
-KBF -KBF C C
/M05/6.E 2 /M05/6.E 4
BLACK
BLACK
-XC4 3 -XC4 4
C C
D D
E E
A A
-XC2 3 -XC2 9 -XC2 11 -XC2 17 -XC2 18
+CCB
-QE
/M02/3.A 26 46 48 42 24
B -BE1 -BE2 -BE2 -BE2 -BE1 B
/M02/6.B 27 /M02/6.B 47 /M02/6.B 49 /M02/5.B 43 /M02/5.B 25
CB SPRING
CB OPENED CB CLOSED CB OPENED CB CLOSED CB CLOSED CB OPENED CB IN SERVICE CB IN TEST CB IN TEST CB IN SERVICE CB IN SERVICE
DISCHARGED
D D
-XDB 30 -XDB 32 -XDB 34 -XDB 37 -XDB 39 -XDB 41 -XDB 45 -XDB 48 -XDB 51
-XDB 31 -XDB 33 -XDB 35 -XDB 36 -XDB 38 -XDB 40 -XDB 42 -XDB 46 -XDB 47 -XDB 49 -XDB 50 -XDB 52
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
PM Elite 448 INTEGRA DIGITAL POWER 1YUX500006B0098 1 CEWE LCD DISPLAY SUPPLY BY CUSTOMER
A SYSTEM 3-phase 3/4-wire A
Frequency: 50/60Hz
Volt input: 57.7-240VAC 3Φ4W/3Φ3W
Current input_ Ib:1-5A, Imax: 200% of Ib
Aux voltage: 80-300V ac/dc
Communication: RS485 interface Modbus
PU DXN-Q-1 CAPACITIVE VOLTAGE SUPPLY BY CNABB 1 LEELEN LED INDICATOR, AC/DC 80~250V, LOCK RELAY WITH 1CO
INDICATOR
SOC YW1L-MF2E11QHG ILLUMINATED PUSH BUTTON 1YUX500009B0001 1 IDEC 22mm DIAMETER CUTOUT, LENS: GREEN, ILLUMINATION: LED
TYPE, FULL SHROUD, 110V AC/DC, 1NO + 1NC CONTACTS
B SOT YW1L-MF2E11QHR ILLUMINATED PUSH BUTTON 1YUX500009B0002 1 IDEC 22mm DIAMETER CUTOUT, LENS: RED, ILLUMINATION: LED B
TYPE, FULL SHROUD, 110V AC/DC, 1NO + 1NC CONTACTS
SS1 M220-61639-003M1 2-POSTION SELECTOR 1YUX500008B0004 1 SALZER 3 POLES, Ith: 20A, SIZE: 48x48mm²
SWITCH LEGEND: CONTROL, LABEL: LOCAL/REMOTE
XMA1 KTT-04S TEST TERMINAL 1YUX500011B0001 1 KACON 4 POLES, PLUSH MOUTED
KBF BC6-30-10 MINI CONTACTOR RELAY GJL1213001R0104 1 ABB VOLTAGE: 110-125VDC, CONTACTS: 3NO+1NO
S101 V15F-070C Door Limit Switch 1YUZ500019A0006 1 KACON Door Limit switch
D Type: V15F-070C D
CONTACTS: 1 CHANGE-OVER
Manufacturer: Kacon
E E
Y
A B A
+CB-QB
VD4/P
1250A
+CCB +CCB +CCB
-BC1 -BC2 -BC3
P1 P1 P1
3x400-800/1/1A
B B
CORE1: CL0.5Fs10
15VA@400/1A
TO SHEET A02
15VA@800/1A
CORE2:CL5P20
15VA@400/1A
TO SHEET A03
15VA@800/1A
C C
P2 P2 P2
+LVD
-PU
1
R:L1
1
Y:L2
D D
1
B:L3
E:PE
-QE -GND
E E
L1 L2 L3
3x400-800/1/1A
CORE1: CL0.5Fs10 , 15VA@400/1A , 15VA@800/1A
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A -GND A
METAL JUMPER
D D
-XA1 12 -XA1 13
3x400-800/1/1A
CORE2:CL5P20 , 15VA@400/1A , 15VA@800/1A
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A -GND A
METAL JUMPER
C C
1 RD 3 YE 5 BU 7 BK
+LVD-XMA1 L1 L2 L3 N
D D
L1 L2 L3 N
2 RD 4 YE 6 BU 8 BK
+LVD -TB2 1 3 5 8
-AR30 IA IB IC N
E /N01/1.A E
IA IB IC IE
N N N Ie
-TB2 2 4 6 7
-XA2 12 -XA2 13
VOLTAGE CIRCUIT
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
+LVD-PM +LVD-PJ
/N99/5.D /N99/5.B
Elite 448 A1700
VOLTAGE INPUTS
VOLTAGE INPUTS
U1 U2 U3 Uo
V1 V2 V3 VN 2 5 8 11
B B
C C
D D
=PREV -XV1 -XV1 -XV1 -XV1 =NEXT
2 4 6 8
-XV1 1
1 -XV1 3
-XV1 1 -XV1 3 -XV1 5
-XV1 3 -XV1 5 -XV1 7
-XV1 5 -XV1 7
-XV1 7 -XV1
E E
NEXT PANEL
PREVIOUS PANEL
B B
-XJ 2 -XJ 4
C C
1 3 12 14 1 3 12 14 1 3 12 14
-FB1 -FB2 -FB3
S202-C6 2 4 11 S202-C6 2 4 11 S202-C6 2 4 11
6A 6A 6A
/X01/2.C
/X01/2.C
/X01/3.C
D D
-XDB 1 -XDB 2
+CB -XB 25
-QB
2
/M01/1.A
-BS1
E 1 E
-MS M
-DC_L1+
-DC_L3+
-DC_L1-
-DC_L3-
/M04/1.A
/M07/1.A
/M04/1.F
/M07/1.F
-XB 35
A A
PREVIOUS NEXT PANEL
PANEL
B B
220V AC, 50Hz -XH 2 -XH 4
1 3 12 14
-FB4
C S202-C6 2 4 11 C
6A
/X01/3.C
COM
-S101
D NC D
A1
1 1 X1
-EL +CCF +CB +LVD
E 220-240VAC -EH2 -EH1 -H20 E
2 2 X2
A2 100W 50W WHITE
-VD4 CN
DOC. No: 1YH8122104 -GND
-XDB 19 30 1 -XDB 12 26 32 37 34 7 6 8 41 20 15 16 43 39 29 -XDB 48 45 11 10 13 51
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
/M04/4.C
/M04/2.C
/M04/8.C
/M07/4.B
/M07/4.B
/M05/1.B
/M05/2.B
/M04/5.E
/M04/1.E
/M04/2.E
/M04/5.E
/M04/5.E
/X03/1.D
/X03/2.D
/X03/3.D
/X03/2.D
/X03/4.D
/X03/4.D
/X03/6.D
/X03/5.D
/X03/7.D
/G01/5.E
/X01/4.E
/X01/4.E
A A
-XB
+CB 24 26 25 4 5 32 27 2 31 41 23 8 11 6 29 28 9 7 1 40 52 12 49 10 57 55
-QB
CB DISCHARGED
CB CHARGED
CB OPENED
CB CLOSED
B -BS2 -BS1 B
4 2 2
-BT2
3 1 0 I 13 23 33 43 53
1
POSITION
SERVICE
-BT1 13 23 33 43 53
C 14 24 34 44 54 C
POSITION
TEST
-RL1 -MC -MO1
D -XB 34 36 35 20 14 15 42 13 37 3 30 33 18 22 21 16 39 38 19 17 50 51 53 54 47 48 58 56 D
/M07/4.C
/X03/1.E
/G01/5.E
/M04/5.E
/M04/5.E
/X01/4.F
/X03/2.E
/X03/3.E
/X03/3.E
/X03/2.E
/M04/1.E
/X03/4.E
/M07/5.C
/M07/4.C
/M05/1.C
/M05/2.C
/X03/4.E
/X01/4.F
/X03/6.E
/X03/6.E
/X03/5.E
/X03/5.E
/M04/8.C
/X03/7.E
/M04/4.D
/M04/2.D
-XDB 21 31 2 -XDB 4 5 27 33 36 38 35 3 9 42 23 22 17 18 44 40 28 -XDB 24 25 49 50 47 46 14 52
DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK EARTHING SWITCH MECHANICAL INTERLOCK WITH CB.-TRUCK
E RL1 CLOSING BLOCK MAGNET BS1 SPRING CHARGING MOTOR CONTACT BT2 LIMIT SWITCH (TEST POSITION) a) C.B. TRUNCK IN TEST-POSITION: EARTHING SWITCH CAN BE OPERATED
E
MO1 FIRST OPENING RELEASE BS2 SPRING CHARGED/DISCHARGED CONTACT BT1 LIMIT SWITCH (SERVICE POSITION) b) EARTHING SWITCH OPEN-POSITION: C.B.-TRUCK CAN BE MOVED
MC CLOSING RELEASE BB1-3 C.B. AUXILIARY SWITCH XB 58 POLE SOCKET INTO SERVICE-POSITION
MS SPRING CHARGING MOTOR XB2..11 CB. INTERNAL POLE PLUG/SOCKET
MU UNDERVOLTAGE RELEASE OPTION
RL2 TRUCK RACK BLOCKING MAGNET OPTION
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: -VACUUM C.B. TRUNK IN SERVICE POSITION -VACUUM CIRCUIT BREAKER OPEN -C.B. SPRING DISCHARGED
CODE: -QB PN: VD4/P -Z - W NAME: VACUUM CIRCUIT BREAKER TYPE: VD4 FUNCTION: NON-STANDARD SECONDARY CONTROL WIRING (7NO-7NC) TECHNICAL DATA: REFER TO SINGLE LINE DIAGRAM
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S CAPACITOR PANEL= J1.4 SCALE: 1: 1
CUSTOMER: VD4 INTERNAL WIRING START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J04+WLV/M01
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M02
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A A
L1 L2 L3
+CCB-QE
/M04/5.C
/M05/5.B
/X03/3.B
/X03/1.B
/X01/5.E
20 22 24 26 28
-BE1
21 23 25 27 29
/M05/5.B
/M04/8.E
/X03/3.B
/X03/2.B
/X03/2.B
/X01/5.E
B B
G 40 42 44 46 48
-BE2
-RL3
H 41 43 45 47 49
C C
D D
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: EARTHING SWITCH OFF AND CRANK NOT INSERTED
CODE: -QE PN: NAME: EARTHING SWITCH TYPE: FUNCTION: STANDARD SECONDARY CONTROL WIRING (5NO-5NC) TECHNICAL DATA: REFER TO SINGLE LINE DIAGRAM
50BF/ARC TRIP SPARE 59 TRIP REMOTE LOCAL PROTECTION TRIP REMOTE LOCAL CLOSE COMMAND VOL. IND. BLOCKING COIL
+
B NC BO2 BI1 -AR30 XI3 6 B
XI1 XI1 3 3 /N01/1.A BO1
-BP1 -
C
-XC2 1
+LVD 4 TB3 2
/M02/5.B +LVD 4
-SOT TB3 4 TB3 14
+CCB -SOC
ES OPENED
/M05/1.E 22
BLACK
XI2 7 -QB
-XC2 2
C C
-XDB 43 53
-XDB 8
/M01/5.A -BT2
+CB -XB 28 /M01/4.A CB IN TEST 54
-QB +CB -XB 23
/N99/7.A
/N99/7.A
/M01/4.D -PU
-XDB 44 /A01/6.C
-XDB 9 P3 P1
+LVD 220V 110V
-XDB 7 -XDB 6 -XDB 10 -XDB 11 -XDB 12 -PU
COM
/M01/4.A /M01/4.A /M01/8.A /M01/8.A /A01/6.C
+CB -XB 31 41
+CB -XB 10 49 /M01/3.A -XC2 21
-QB -QB +CB -XB 4
13 43 43 -QB +CCB
-BB2 -BT1 -BT2 0V -QE
E 14 P2 /M02/3.A E
44 44
/N99/7.A
-MC CB CLOSING RELEASE G
CB FIRST OPENING CB CLOSING
-MO1 -RL1 -RL3
RELEASE BLOCKING MAGNET
H
-XB 30 -XB 20 -XB 14
/M01/4.D /M01/2.D /M01/3.D
-XDB 3 -XDB 4 -XDB 5
CB OPENED
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A A
-L1+
/M04/8.A -XK1 4 -XK1 5
/M01/5.A /M01/5.A
B B
+CB -XB 6 -XB 29
+CCB
-QB -QE
/M02/3.A 20 40
13 21 TB3
-BE1 -BE2 +LVD 5
-BB3 -BB3 -AR30
21 41
14 22 /N01/1.A BO3
C C
D D
1 2 /X02/4.C
3 4 /X02/4.C
5 6 /X01/6.C
2 3 13 14
2 3
X1 X1 A1
+LVD-SOT +LVD-SOC +LVD-P1 -KBF
/M04/3.B /M04/6.B
+LVD-P2
X2 X2 A2
RED GREEN 1
E 1 E
-XK1 9
-L1-
/M04/8.F
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S CAPACITOR PANEL= J1.4 SCALE: 1: 1
CUSTOMER: INDICATOR CIRCUIT & 50BF SIGNAL START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J04+WLV/M05
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: M07
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
PROTECTION AND CONTROL UNIT BINANY INPUT
CB SPRING STATUS CB STATUS
CB CLOSED
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
DPM AUXILIARY SUPPLY POWER FOR RELAY CONTROL MODE CB SPRING CHARGED CB OPENED
A A
-DC_L3+
/G01/3.E -XK2 1 -XK2 2 -XK2 3
-XDB 19 -XDB 20
/M01/1.A /M01/5.A
B B
+CB -XB 24 -XB 11
-QB
/M01/1.A
11 4 53 41
1 2
C C
-GND
D D
+/P -TB2 12 13 TB3 15 17 18 19 20
+LVD +LVD + ++
-PM (AC/DC) -AR30
+
+
/N99/5.D /N01/1.A
-PS BI2 BI3 BI4 BI5 BI6
- - - - -
--
-/N -TB2 14 TB3 16 22
E E
-XK2 4
-DC_L3-
/G01/4.E
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S CAPACITOR PANEL= J1.4 SCALE: 1: 1
CUSTOMER: RELAY INPUT SIGNALS START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J04+WLV/M07
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: N01
1 2 3 4 5 6 7 8
F
E
C
A
D
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A
REV.
1
1
DESCRIPTION
VOLTAGE L1 /A03/3.E -TB2 1
(-) /A03/3.E 2
IL1
2
2
VOLTAGE L2 /A03/4.E 3
(-) /A03/4.E 4
IL2
VOLTAGE L3 /A03/5.E 5
(-) /A03/5.E 6
IL3
VOLTAGE N /A03/5.E 7
(-) /A03/5.E 8
IE
9
10
11
GND /M07/2.D 12
+
+ /M07/2.D 13
- Uaux
- /M07/2.E 14
3
3
DATE
23/08/17
BIO MODULE
OUTPUT 1 (CB CLOSE) /M04/6.B TB3 1
/M04/6.B 2
BO1*
OUTPUT 2 (CB TRIP) /M04/3.B 3
BO2*
CUSTOMER:
/M04/3.B 4
OUTPUT 3 /M05/6.B 5
PROJECT TITLE:
/M05/6.C 6
BO3*
DESIGNED: HANG
OUTPUT 4 /X03/5.B 7
/X03/5.B 8
BO4*
RELAY FAIL (NC) /X01/5.C 9
4
4
/X01/4.C 10
11
12
BINARY INPUT 1 (INCLUDE TCS) (+) /M04/4.B 13
(-) /M04/4.B 14
BI1
BINARY INPUT 2 (INCLUDE TCS)(+) /M07/3.D 15
(-) /M07/3.E 16
BI2
SEE
BI3
BINARY INPUT 4 /M07/4.D 18 BI4
BINARY INPUT 5 /M07/4.D 19 BI5
BINARY INPUT 6 /M07/5.D 20 BI6
COM /M07/3.E 22
APPROVED:
5
5
BIO MODULE
OUTPUT 5 /M04/5.C TB1 1
/M04/5.D 2
BO5
OUTPUT 6 /X03/5.B 3
/X03/5.B 4
BO6
OUTPUT 7 /X01/5.C 5
/X01/5.C 6
BO7*
OUTPUT 8 /X01/6.C 7
DRAWING TITLE:
/X01/6.C 8
BO8*
6
6
TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559
7
7
8
8
SCALE:
LANGUAGE:
==SWG1=J04+WLV/N01
ENG
N99
START: 23/08/2017
1: 1
F
E
C
A
D
1 2 3 4 5 6 7 8
/M04/8.D
/M04/8.D
/M04/7.D
/M04/7.D
/M04/7.E
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
+LVD-SS1
CONTROL NO COM NC P1 P2 P3
A A
+LVD 110V 0V 220V
1 2 -PU
1 3 5 7 9 11 AUXILIARY VOLTAGE
VOLTAGE INDICATOR
2 4 6 8 10 12
/M04/3.A
/M04/2.A
/M04/6.A
/M04/5.A
/X01/6.E
/M07/3.B
NORMAL HANDLE
1 LOCAL
B 2 REMOTE B
+LVD-PJ
/A02/5.E
/A02/5.E
/A02/6.E
/A02/6.E
/A02/6.E
/A02/7.E
/A04/4.B
/A04/4.B
/A04/5.B
/A04/5.B
/M07/1.D
/M07/1.E
D D
+ - SG -/N +/P
+LVD - + Elite 448
-PM
RS485 POWER SUPPLY
COMMUNICATION PORT (AC/DC SUPPLY)
/A02/2.E
/A02/3.E
/A02/3.E
/A02/3.E
/A02/4.E
/A02/4.E
/A04/3.B
/A04/3.B
/A04/3.B
/A04/3.B
F PROJECT NO.: UG17019 DRAWING NO.: 1YUX20000A0062 F
PROJECT TITLE: DRAWING TITLE: LANGUAGE: ENG
110kV VSIP II MR1 S/S CAPACITOR PANEL= J1.4 SCALE: 1: 1
CUSTOMER: CROSS REFERENCE START: 23/08/2017
SEE
A ISSUED FOR APROVAL 23/08/17 ABB XIAMEN SWITCHGEAR CO.,LTD SHEET: ==SWG1=J04+WLV/N99
REV. DESCRIPTION DATE DESIGNED: HANG PTD CHECKED: NINH NV APPROVED: TEL: (+86) 592 602 6033 , TELEFAX: (+86) 592 603 0505-8559 CONT.: X01
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
ALARM WIRING CIRCUIT TO REMOTE CONTROL PANEL
COMMON AC/DC SUPPLY CIRCUIT BRIDGE
INTERNAL RELAY OC/EF TRIP TCS ALARM 50BF
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
A =PREV =NEXT A
/M01/3.A /M01/6.A
-XB 5 -XB 7 +CCB
+CB -QE
E -QB /M02/3.A E
44 28 9
13 53 +LVD 1 2
-BE2 -BE1
-BB1 -BB3 -SS1
45 29 10
14 54 /N99/4.A
-XB 15 -XB 17
/M01/3.D /M01/6.D
A =PREV =NEXT A
BROWN
BROWN
NC NC
1 3 -BP2 -BP3
-KBF -KBF C C
/M05/6.E 2 /M05/6.E 4
BLACK
BLACK
-XC4 3 -XC4 4
C C
D D
E E
A A
+CCB
-QE +LVD TB1 3 TB3 7
/M02/3.A 26 46 48 42 24 -AR30
B -BE1 -BE2 -BE2 -BE2 -BE1 /N01/1.ABO6 BO4 B
/M02/6.B 27 /M02/6.B 47 /M02/6.B 49 /M02/5.B 43 /M02/5.B 25
TB1 4 TB3 8
CB SPRING
CB OPENED CB CLOSED CB OPENED CB CLOSED CB CLOSED CB OPENED CB IN SERVICE CB IN TEST CB IN TEST CB IN SERVICE CB IN SERVICE
DISCHARGED
D D
-XDB 30 -XDB 32 -XDB 34 -XDB 37 -XDB 39 -XDB 41 -XDB 45 -XDB 48 -XDB 51
-QB
2 21 53 31 43 41 31 33 33 23 23 53
-BS2 -BB1 -BB1 -BB1 -BB3 -BB2 -BT1 -BT2 -BT2 -BT1 -BT1
1 22 54 32 44 42 32 34 34 24 24 54
E E
-XDB 31 -XDB 33 -XDB 35 -XDB 36 -XDB 38 -XDB 40 -XDB 42 -XDB 46 -XDB 47 -XDB 49 -XDB 50 -XDB 52
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
D D
E E
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
FF1...FF3 CEF High Voltage Fuse 1YMB531044M0001 3 ABB POLAND Rate Voltage 24kV
Rate current: 6A with Striker, E=442
S101 V15F-070C Door Limit Switch 1YUZ500019A0006 1 KACON Door Limit switch
Type: V15F-070C
CONTACTS: 1 CHANGE-OVER
Manufacturer: Kacon
D D
E E
B
A A
+CB-QS
LBS
630A
24kV
B 6A 6A 6A B
+LVD
-PU
1
R:L1
C C
1
Y:L2
1
B:L3
E:PE
D D
-GND
-QE
E E
L1 L2 L3
110V DC
XJ 1 -XJ 1 XJ 1
XJ 3 -XJ 3 XJ 3
B B
110V DC 110V DC
-XJ 2 -XJ 4
C C
1 3 12 14
-FB1
S202-C6 2 4 11
6A
/X01/2.C
D D
E E
-DC_L1+
-DC_L1-
/M02/1.A
/M02/1.F
A A
PREVIOUS NEXT PANEL
PANEL
XH 1 -XH 1 XH 1
XH 3 -XH 3 XH 3
B B
220V AC, 50Hz -XH 2 -XH 4 220V AC, 50Hz
1 3 12 14
-FB2
S202-C6 2 4 11
6A
C C
COM
D -S101 D
NC
A1
1 1 X1
-EL +CCF +CB +LVD
E 220-240VAC -EH2 -EH1 -H20 E
2 2 X2
A2 100W 50W WHITE
-NALF
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
/M02/5.D
/M02/3.B
/M02/3.B
/M02/2.B
/M02/2.B
/M02/5.E
/X03/4.D
/X03/4.D
/X03/2.D
/X03/3.D
/X03/1.D
/X03/2.B
/X03/3.B
/X03/2.B
/X03/3.B
/X01/5.E
/X01/5.E
/X01/4.E
/X01/4.E
A A
-BE-3E -BE-7E -BE-11E -BE-15E -BE-1E -BE-5E -BE-9E -BE-13E RL4-G RL3-G -BF-1SF -BF-3SF -BB1-3 -BB1-7 -BB1-11 -BB1-15 -BB1-1 -BB1-5 -BB1-9 -BB1-13
+CB
-QS
B B
BE -BB1
3E 7E 11E 15E 1E 5E 9E 13E 1 3 7 11 15 1 5 9 13
-RL4
4E 8E 12E 16E 2E 6E 10E 14E 2 4 8 12 16 2 6 10 14
BF 1 BF 3
2 4
C C
1
-RL3
2
D -BE-4E -BE-8E -BE-12E -BE-16E -BE-2E -BE-6E -BE-10E -BE-14E RL4-H RL3-H -BF-2SF -BF-4SF -BB1-4 -BB1-8 -BB1-12 -BB1-16 -BB1-2 -BB1-6 -BB1-10 -BB1-14 D
/M02/3.C
/X01/5.E
/M02/3.C
/X01/5.E
/M02/5.E
/X03/4.E
/X03/4.E
/M02/2.C
/X01/4.E
/X03/2.E
/X03/3.E
/M02/2.C
/X03/1.E
/X01/4.E
/M02/5.D
/X03/2.B
/X03/3.B
/X03/2.B
/X03/3.B
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: LOAD BREAK SWITCH OPEN EARTHING SWITCH OPEN FUSES NOT BLOWN
CODE: -QI PN: NALF NAME: LOAD BREAK SWITCH TYPE: NALF FUNCTION: STANDARD SECONDARY CONTROL WIRING (4NO-4NC) TECHNICAL DATA: REFER TO SINGLE LINE DIAGRAM
A A
-DC_L1+
/G01/4.E -XK1 1 -XK1 2 -XK1 3 -XK1 4 -XK1 5 -XK1 6
B B
/M01/7.A /M01/6.A /M01/2.A /M01/1.A
+CB -BB1-1 -BB1-3 +CB -BE-1E -BE-3E
-QS -QS
BB1 BB1 BE BE
XI3 1
-JUMPER
-BB1-2 -BB1-4 -BE-2E -BE-4E
/M01/7.D /M01/6.D /M01/2.D /M01/1.D
XI3 2
XI3 3
C C
-JUMPER
XI3 4
/N99/3.A
/N99/3.A
/M01/8.A LBS OPENED
P1 P3 +CB -BB1-13
+LVD 110V 220V -QS
-PU
-XK1 10 -XK1 11 -XK1 12 -XK1 13 /A01/4.C
BB1
D D
0V -BB1-14
/M01/8.D
P2
-XK1 14
/N99/3.A
/M01/5.A
+CB RL3-G
2 3 2 3
-QS
+LVD-P1 +LVD-P2 1
-RL3
E E
1 1 2
RL3-H
/M01/5.D
/M02/4.D
/M02/4.D
/M02/4.D
/X03/6.E
/X03/6.E
A A
NO COM NC P1 P2 P3
+LVD 110V 0V 220V
-PU
AUXILIARY VOLTAGE
VOLTAGE INDICATOR
B B
C C
D D
E E
MCB OFF
A A
=PREV =NEXT
PREVIOUS
-XI4 6 -XI4 8
-XI4 10 -XI4 12 -XI4 14 -XI4 16 -XI4 18 -XI4 20 -XI4 22
12 14 12 14
C C
-FB1 -FB5
/G01/4.C 11 11
D D
A A
B B
BE BE BE BE
C C
LBS OPENED LBS CLOSED LBS CLOSED FUSE NORMAL FUSE BLOWN
-XC3 2
-XC3 4 -XC3 6 -XC3 8 -XC3 10 XC5 2
A
ABB Xiamen Switchgear Co.,Ltd. A
B B
Customer : SEE
FOR APPROVAL
KINDLY TICK THE FOLLOWING BOX
TABLE OF CONTENTS
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
D D
E E
BILL OF MATERIALS
DESIGNATION PART NUMBER MATERIAL DESCRIPTION SAP CODE QUANTITY MANUFACTURER MATERIAL TECHNICAL DATA REMARK
This document must not be copied without our written permission, and the contents thereof must not be imported to a third party not be used for any unauthorized purpose. Contravention will be prosecuted.
EF FAN 220VAC FAN FOR VCB SUPPLY BY CNABB 1 SUPPLY BY CNABB Voltage Supply: 220VAC
A A
EH1 50W220VAC ANTI-CONDENSATION SUPPLY BY CNABB 1 BOXIN 50W, 220VAC, 50Hz
HEATER
QT TRUCK LINK ISOLATING TRUCK SUPPLIED BY CNABB 1 CNABB RATED VOLTAGE: 24kV
RATED CURRENT: 2500A
POLE DISTANCE : 275
FOR UGZS1 - 1000mm
POSITION CONTACTS -BT1/-BT2
QT -RL2_PART OF TRUCK TRUCK BLOCKING MAGNET SUPPLY BY CNABB 1 ABB LOCKING MAGNET ON OPERATING MACHANISM -RL2 - 110VDC
B B
BU1...BU3 CGR_24kV CAPACITIVE VOLTAGE SUPPLY BY CNABB 3 PEAKS RATED VOLTAGE: 24kV
DIVIDER
EH2 100W220VAC ANTI-CONDENSATION SUPPLY BY CNABB 1 BOXIN 100W, 220VAC, 50/60Hz
HEATER
H20 YW1P-2EQM3W PILOT LIGHT 1YUX500009B0011 1 IDEC LENS: YELLOW, 22mm DIAMETER CUTOUT, 230/240V AC/DC
H24 YW1P-2EQM3A PILOT LIGHT 1YUX500009B0021 1 IDEC LENS: AMBER, 22mm DIAMETER CUTOUT, 230/240V AC/DC
Y
A B A
+CB-QT
S-VD4/P
2500A
B B
C C
+LVD
-PU
1
R:L1
1
D D
Y:L2
1
B:L3
E:PE
-GND
E E
L1 L2 L3
110V DC
B B
110V DC 110V DC
-XJ 2 -XJ 4
C C
1 3 12 14
-FB1
S202-C6 2 4 11
6A
/X01/2.C
D D
E E
-DC_L1+
-DC_L1-
/M04/1.A
/M04/1.F
220V AC, 50Hz 220V AC, 50Hz 220V AC, 50Hz 220V AC, 50Hz
A A
PREVIOUS NEXT PANEL
PANEL
B B
220V AC, 50Hz -XH 2 -XH 4 220V AC, 50Hz
1 3 12 14
-FB2 3
S202-C6 2 4 11 +LVD 1 2
6A -SS5
C 4 C
ON
/N100/2.A
-XH 13 8
-XH 14 -KT
=INC. PANEL (J1.1) /N100/5.C
-XH 5 -XH 6 -XH 7
-XH 18
1 5 5 6
1 -KBR
-S101 9 -XH 17
D 2 D
-XH 19
4
-XH 15 +CB
-XH 12 -EF 2 4
/N100/1.C
-XH 16
2 S231
Z1/1 1
A1 -KT
1 1 X1 +CB /N100/5.C 1
+CCF +CB +LVD
E -EL -EF E
220-240VAC -EH2 -EH1 -H20 X2 /N100/1.C -XH 18
100W 2 50W 2 WHITE
A2 X1
Z1/2 +LVD
7 -H24
X2
AMBER
/M04/2.C
/M04/6.E
/X03/1.E
/X03/3.E
/X01/4.E
/X01/4.E
/X03/2.E
/X03/3.E
A A
-XS
+CB 12 52 11 10 49 57 55 1 40 45
-QT
B B
-BT2
33 23 13 43 53
34 24 14 44 54
-RL2
POSITION
SERVICE
-BT1 33 23 13 43 53
C 34 24 14 44 54 C
POSITION
TEST
D -XS 47 48 53 54 50 51 20 58 56 46 D
/M04/2.C
/M04/2.C
/X03/1.E
/X03/3.E
/X03/4.E
/X01/4.F
/X03/2.E
/X03/3.E
/M04/6.E
DESIG. DESCRIPTION REMARK DESIG. DESCRIPTION REMARK
XS 58 POLE PLUG/SOCKET BT1 LIMIT SWITCH (SERVICE POSITION)
E BT2 LIMIT SWITCH (ISOLATED POSITION)
E
RL2 BLOCKING MAGNET FOR TRUCK
INTERNAL WIRING / CROSS REFERENCE THE DIAGRAM INDICATES THE FOLLOWING CONDITION: ISOLATING TRUCK IN SERVICE POSITION
CODE: -QST PN: EP-CDX2000158R0002 NAME: ISOLATING TRUCK TYPE: UG 550 ISOLATING TRUCK TECHNICAL DATA: REFER TO MATERIAL REPORT
A -DC_L1+ A
/G01/3.E -XK1 1 -XK1 2
-XI3 1
-JUMPER
-XI3 2
-XI3 3
=INCOMING (J1.1)
-XI1 1
CB IN TEST
23
B B
-XC3 4 +CB-BT2
24
-XI1 2
/M01/4.A -XI3 4
+CB -XS 12
-QT
-XI3 5
33 33 -JUMPER
-BT2 -BT1
C 34 34 7 C
-XI3
-XS 47 48
/M01/4.D /M01/4.D
-XI3 6
-JUMPER
-XI3 8
-XC3 5 -XC3 6
D D
/N100/7.A
/N100/6.A
P3 P1
+LVD 220V 110V -XC3 7
-PU
/A01/6.C
/M01/7.A
+CB -XS 45
2 3 -QT
E 0V E
-RL2
+LVD-P1 P2
/N100/7.A
1
-XS 46
/M01/7.D
-XC3 8
-DC_L1- -XK1 3 -XK1 4
/G01/4.E
+LVD-SS5
/M04/4.D
/M04/4.D
FAN MODE
/M04/4.E
A A
1 2
1 3 5 7
NO COM NC P1 P2 P3
+LVD 110V 0V 220V
2 4 6 8
-PU
/G02/4.C
NORMAL HANDLE AUXILIARY VOLTAGE
VOLTAGE INDICATOR
1 OFF
2 ON
B B
-GND
/G02/4.E
/G02/6.C
/G02/5.E
Z1/1 2
+CB GND 2 8
-EF Z1/1 1 1 -KT
2 3 TIMER RELAY
C x1 U1 Z2 S231 C
-VR
x2 Z1 U2
1
Z1/2 2 3
7 5 6
FAN FOR VCB
Z1/2 1
/G02/5.E
/G02/6.D
/G02/6.D
/G02/4.E
/G02/6.E
D D
E E
MCB OFF
A =PREV =NEXT A
B B
-XI4 6
12 14 12 14
C PREVIOUS NEXT PANEL C
-FB1 -FB5
/G01/3.C 11 11
LINK STATUS
/M01/5.A /M01/5.A
+CB -XS 10 49
E -QT E
43 43
-BT1 -BT2
44 44
-XS 20
/M01/5.D
XC1 2
A A
B B
C C
ISOLATED POS. ISOLATED POS. SERVICE POS. ISOLATED POS. SERVICE POS.
D D
-XC3 9 -XC3 11 -XC3 13 -XC3 15
-QT
23 53 53 13 13
-BT2 -BT2 -BT1 -BT2 -BT1
E 24 54 54 14 14 E