ELECTRONIC POWER FACTOR METERS WITH 240°SCALE
96cQa, 96cQb 144cQa, 144cQb
Pivot and jewel moving-coil movement with
integrated electronic circuit
Technical data:
Instrument case: steel-plate
Scale length: 140mm (96cQ…), 230mm (144cQ…)
Class of accuracy: 1.5
Rated UN: 100 V, 110 V, 230 V, 400 V, 500 V
Operating range: UN ±15%
Rated IN: 5 A or 1 A
Operating range: 0.2 x IN - 1.2 x IN
Frequency range: 45…50…60 Hz
Consumption: max. 0.5 VA in the current circuit
and max. 12 mA in the voltage circuit
Protection: casing IP50, terminals IP00
Weight: 0,65 kg (96cQ…), 0,9 kg (144cQ…)
Fixing elements: with two spring-type fastening clips
(DIN 43835 ″A″)
Single phase Three - phase balanced
Rated cap. 0,5 - 1 - 0,5 ind. cap. 0,8 - 1 - 0,2 ind. cap. 0,5 - 1 - 0,5 ind. cap. 0,8 - 1 - 0,2 ind.
voltage Rated current Rated current Rated current Rated current
.../5 A .../1 A .../5 A .../1 A .../5 A .../1 A .../5 A .../1 A
96cQa 144cQa 96cQb 144cQb
…/100 V x x x x x x x x
…/110 V x x x x x x x x
230 V x x x x x x x x
400 V x x x x x x x x
500 V x x x x x x x x
Outline drawing
d g
a c
b e
Type\Dim. (mm) a b c *d e f g
96cQa 96cQb 96 60 51 76 5,5 90 92+0.8
144cQa 144cQb 144 77 65 ...... 7 135 138+1
* case with terminal cover
Connection diagrams
Order specification
Power factor meter for three-phase three
wire balanced circuit
Frame dimension: 96x96mm
Rated voltage: 400 V
Current transformer: …/5 A
Range: cap. 0.5-1-0.5 ind.
L1 L1
N L2 96cQb 400V…/5 A cap. 0.5-1-0.5 ind.
L3
96cQa, 144cQa, 96cQb, 144cQb