0% found this document useful (0 votes)
14 views2 pages

Brosur RN Series

Uploaded by

antoganteng8
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views2 pages

Brosur RN Series

Uploaded by

antoganteng8
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ICA

RN
45

series
008

(NEW) Power Supply The Best Solution for Power System


Uninterruptible

ICA

ICA

ICA

ICA

True On Line Sinewave Output Auto Restart


EMI /RFI Filter Rack Mount 19”
With Power Factor Correction Circuit Easy to Install
SMPS Design Non-Transfer Time of Output
Full Bridge IGBT Inverter Full Digital Control (DSP)
Electronic Output Short Circuit Protection Self-Testing when UPS Start-Up
High Efficiency Input Over/ Under-Voltage Protection
High Reliability Automatic Bypass
Wide Input Voltage Range DC Start
Wide Input Frequency Range Optimization Battery Group
(optional for 6-10kVA)
Support Generator Input
Ready for Parallel (6-10kVA)
Support Economic Operation Mode
Communication Port: RS232, USB
Expandable Back Up Time Communicate with Most LAN System and Stand
Audible and Visual Indicator Alone PC, Auto Save and Auto Shutdown

Protect your computer and sensitive equipments from any electrical disturbance.
ICA
R

RN
series
Product Technical
Specifications
(new)

MODEL RN1100C RN2100C RN3100C RN6100C RN1102C11


Capacity (VA/Watts) 1000 / 900 2000 / 1800 3000 / 2700 6000 / 5400 10000 / 9000
INPUT
Rated voltage 200/208/220/230/240Vac 220/230/240Vac
Voltage range 110 ~ 300Vac (depend on load percentage) 115 ~ 285Vac (depend on load percentage)
Frequency range 40 ~ 70Hz (auto detect) 44~55 / 54~66 ±0.5
Power factor ≥0.99
Bypass high voltage point 220V: +25% (optional +10%, +15%, +20%)
Setting in LCD from 230Vac to 264Vac (Default: 264Vac) 230V: +20% (optional +10%, +15%)
Bypass voltage range
Bypass low voltage point 240V: +15% (optional +10%)
Setting in LCD from 170Vac to 220Vac (Default: 170Vac) Min. voltage: -45% (optional -20%, -30%)
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac 220/230/240Vac
Power factor 0.9
Voltage regulation ±1% ±2%
Line Mode 45~55Hz (for 50Hz) or 55~65Hz (for 60Hz)
Frequency
Bat. Mode 50/60 (±0.01)Hz
Crest factor 3:1
≤3% with linear load ≤2% with linear load
Harmonic distortion (THDv)
≤6% with non-linear load ≤5% with non-linear load
Waveform Pure Sinewave
>88% >89% >90% >93.5%
BATTERY
Battery voltage 24Vdc 48Vdc 72Vdc +/-96V; +/-108V; +/-120V (can be set)
Battery number (internal battery) 2 x 12V, 7Ah 4 x 12V, 7Ah 6 x 12V, 7Ah - (External Battery / Battery Pack)*
Typical recharge time 4 hours (to 90% of full capacity) 6~8 hours (to 90% of full capacity)
Backup time Estimated remaining time displayed on the LCD
Charging current (max.) 1A 10A
SYSTEM FEATURES
Transfer time Utility to Battery: 0ms; Utility to Bypass: <4ms
Load ≤110%: last 10min; ≤130%: last 1min; ≤150%: last 5S; >150% turn to bypass mode (1~3kvA)
Overload (Line Mode)
Load ≤110%: last 60min; ≤125%: last 10min; ≤150%: last 1S; >150% turn to bypass mode (6~10kVA)
Short circuit Hold Whole System
Overheat Line Mode: Switch to Bypass; Backup Mode: Shutdown UPS immediately
Battery low Alarm and Switch off
EPO (optional) Shutdown UPS immediately
Audible & visual alarm Line Failure; Battery Low, Overload, System Fault
Communication interface USB (or RS232), SNMP card/ relay card (optional)
ENVIRONMENTAL
Operating temperature 0 ~ 40 0C
Storage temperature -25 ~ 55 0C
Humidity range 20 ~ 90% (non-condensing)
Altitude <1500m
Noise level <50dB at 1 meter
PHYSICAL
Dimensions W x H x D (mm) 440x86.5x325 (2U) 440x86.5x435 (2U) 440x86.5x600 (2U) 440 x 130 x 680 (3U)
Net weight (kg) 11.5 19.6 26.7 19.0 21.0
Gross weight (kg) 13.9 22.7 30.1 24.0 25.5
STANDARDS
Safety IEC/EN62040-1, IEC/EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
*BATTERY PACK for 6~10kVA
Voltage +/-120Vdc
Type & number 20 x 12V/7Ah SLA Battery
Dimensions W x H x D (mm) 440 x 130 x 720 (3U)
Net Weight (kg) 57
Gross Weight (kg) 62

Contact Person
REAR PANEL RN1100C & RN2100C

REAR PANEL RN3100C

REAR PANEL RN6100C & RN1102C11

481-41E0010-220

You might also like