Bracket design.

xlsx

5.0 Splicing Detail for Splay Strut at Level-1 & 2

5.1 Section Considered : UC 305x305x158.1 kg/m

Web Splice plate


Flange Splice plate

327.1 Web Splice plate

Flange Splice plate

5.2 Member Flange Splice


Flange size of I beam a = 311.2 mm
b = 25 mm
Area of flange for One section axb = 7780 mm2
Area of Splice Plate Reqd. (5% Extra) = 8169
Thickness of splice plate = 20 mm
Width of the splice plate required = 408 mm Say 420 mm

2
Yield Strength of Steel Section fy = 330 N/mm
Material Factor m = 1.1
Force carried by the flange plate = 8169 x 330/1.1
= 2451 kN

Size of the weld for flange splice = 12 mm OK


Ultimate Strength of Weld (IS 814, Table -8) fu = 540 Mpa
Partial Safety factor for Site Weld = 1.5 Mpa
Design Strength of Weld fwd = (fu /√3)/
= 208 Mpa

Weld strength per mm of length (90° fillet weld) = 0.7×208×12


= 1746 N/mm

Total weld length required for the flange plate = 2451/1746×1000


lt = 1404 mm

Assumed Length of Plate Say 1200 mm

Total Length of Weld provided 1511 mm

Therefore provide flange plate of 1200 x 420 x 20 with 12 mm weld on either side

5.3 Member Web Splice


Depth of the web = 277.1 mm
Thickness of the web = 15.8 mm
Area of web Plate = 4378.18 mm2
Area of Splice Plates Reqd. = 4597 mm
Thickness of web splice plate considered on one side of Web = 10 mm
Depth of the web plate required = 230 mm
Provided depth of Web Plate = 230 mm
Bracket design.xlsx

5.0 Splicing Detail for Splay Strut at Level-1 & 2

Yield Strength of Steel Section fy = 350 N/mm2


Material Factor m = 1.1
Force carried by the flange plate = 4597.089 x 350/1.1/2
= 731 kN

Size of the weld for flange splice = 8 mm


Ultimate Strength of Weld (IS 814, Table -8) fu = 540 Mpa
Partial Safety factor for Site Weld = 1.5 Mpa
Design Strength of Weld fwd = (fu /√3)/
= 208 Mpa

Weld strength per mm of length (90° fillet weld) = 0.7×208×8


= 1164 N/mm

Total weld length required for the flange plate = 731/1164×1000


lt = 628 mm

Assumed Length of Plate Say 500 mm

Total Length of Weld provided 730 mm

Therefore provide web plate of 500 x 230 x 10 with 8 mm weld on either side