SNC10HW Schmid-M JG Es
SNC10HW Schmid-M JG Es
Features
Reinforced Insulation for 250Vrms Working Voltage
Compact DIP-24 Package
Wide 4:1 Input Range
Isolation Voltage up to 5000VAC
Over Voltage Protection
Over Load Protection
Continuous Short Circuit Protection
Remote On/Off Control
Under Voltage Protection
Soft Start
No minimum load required
Efficiency up to 89%
-40~100°C Operation Temperature Range
SNC 10 H W - 24 05 S
⑴ ⑵ ⑶ ⑷ ⑸ ⑹ ⑺
MODEL NUMBER Voltage Range No-Load Full Load Voltage Min. load Full load @FL Load @FL
(Vdc) (mA, typ.) (mA, typ.) (Vdc) (mA) (mA) (%, typ.) (μF, max.)
GENERAL SPECIFICATIONS
Parameter Conditions Min. Typ. Max. Unit
Isolation Voltage Input-output, and rated for 60sec 5000 VAC
Isolation Resistance Input-output 1 GΩ
Isolation Capacitance Input-output 17 pF
Leakage Current 240VAC, 60Hz 2.0 μA
Clearance/Creepage 8 mm
Switching Frequency 300 kHz
MTBF MIL-HDBK-217 F @ 25°C 650 k hours
Safety Standard IEC / EN / UL 62368-1 DK-133116-UL, E252573
Insulation System Reinforced Insulation
Environmental compliance RoHS
ENVIRONMENT SPECIFICATIONS
Parameter Conditions Min. Typ. Max. Unit
Operating Temperature See the Derating Curve -40 100 °C
Maximum Case Temperature 105 °C
Thermal Impedance 18 °C/W
Storage Humidity 95 % rel. H
Storage Temperature -55 125 °C
Cooling Natural Convection 30-65 LFM
PHYSICAL SPECIFICATIONS
Parameter Value
SNC10HW-2405S、SNC10HW-2405D
SNC10HW-1205S、SNC10HW -1205D SNC10HW-4805S、SNC10HW-4805D
OUTPUT POWER
OUTPUT POWER
100 100
75 75
50
S.O.A. 50
S.O.A.
25 25
0 0
-40 -20 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 120
72 74
AMBIENT TEMPERATURE(°C) AMBIENT TEMPERATURE(°C)
SNC10HW-1215S、SNC10HW-1215D、SNC10HW-2412S、SNC10HW-2412D
SNC10HW-1212S、SNC10HW-1212D SNC10HW-4812S、SNC10HW-4812D、SNC10HW-4815S、SNC10HW-4815D
100 100
75 75
50
S.O.A. 50
S.O.A.
25 25
0 0
-40 -20 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 120
77
AMBIENT TEMPERATURE(°C) AMBIENT TEMPERATURE(°C)
SNC10HW-2415S、SNC10HW-2415D
Derating Curve
120
OUTPUT POWER
100
75
50
S.O.A.
25
0
-40 -20 0 20 40 60 80 100 120
82
AMBIENT TEMPERATURE(°C)
+Vout
+Vin
Lin Current
Probe DC/DC Load
Cin Converter
-Vin -Vout
Single
+Vin +Vout
DC/DC
Vin Load
C1 D1 Converter
-Vin -Vout
Dual
C1 D1
PIN CONNECTIONS
PIN
SINGLE DUAL
31.8 2.54 2.54 NUMBER
(1.25) (0.10) (0.10)
1 CTRL CTRL
1.93 20.32 4.47
DC-DC CONVERTER (0.08) (0.18)
SNC10HW-1205S
(0.80) 2 -Vin -Vin
Input:4.5-18Vdc 2878mA
20.3 2.53
Output:5Vdc 2000mA
(0.80)
SCHMID-M (0.10) 10 Trim Trim
1 2 10 11
2209
15.24
(0.60) 11 N.C. -Vout
Top view 23 22 16 14
2.53
(0.10)
14 +Vout +Vout
15.24
10.2
4.47
(0.60)
4.47 16 -Vout COM
(0.18) (0.18)
(0.41)
3.0
2.54 5.08
22 +Vin +Vin
(0.12)
(0.10) (0.20)
PIN CONNECTIONS
Output can be externally trimmed by using the
method as below.
Rtrim-up Rtrim-down
10 10
16 14
2.54 5.08
(0.10) (0.20)
2.83
(0.11)
Notes:1. All dimensions are typical in millimeters (inches).
23 22 16 14 Through hole(Black) 2, 3, 10, 11, 14, 16, 22, 23 : Ø 0.90 (0.035)
15.24 Top view pad(Green) 2, 3, 10, 11, 14, 16, 22, 23 : Ø 1.10 (0.044)
(0.60) Bottom view pad(Pink) 2, 3, 10, 11, 14, 16, 22, 23 : Ø 1.80 (0.071)
1 2 10 11 2. There should be at least 8mm distance between primary and secondary circuit.
2.83
(0.11)
2.54 2.54
(0.10) (0.10)
Top view