Electronic Timers

On Delay • On Pulse • Symmetrical Recycler TXM

DESCRIPTION OPERATION
Multifunction timer with 4 functions and 4 time ranges. The function The function is selected via the rotary switch on the timer front. The
and the time range are selectable via 2 front mounted rotary switch may only be operated, when supply voltage is disconnected.
switches.
The time ranges cover 0.1sec.-10min. or 1min.-100hours. The time On delay.
is adjustable on the timer front. The timing period starts when supply voltage is connected. When
The timer is available in different versions for AC or DC supply the preset time has elapsed, the relay is energized.
voltage.Single or double output relay or NPN transistor output with The relay is de-energized when the supply voltage is disconnected.
LED indica-tion of energized output.
Options as remote timer start or timer interrupt from control switch
Supply
or NPN sensor and remote time adjustment are available.
Versions available for DIN rail or 11-pole plug-in mounting.
T T

On pulse.
When supply voltage is connected, the relay is energized and the
timing period starts. The relay de-energizes when the preset time
has elapsed.

Supply

T T

Symmetrical recycler with pause or pulse start.


Depending on the setting of the function switch the timer starts with
e.g a pause, when supply voltage is connected. When the pause
period has elapsed, the relay energizes. The relay remains ener-
VERSIONS/ORDERING CODES gized during the pulse period. The sequence is repeated until the
supply voltage is disconnected.
Type: TXM - S 1 230 . L / E The duration of the pause and pulse periods is equal.
On delay.
On pulse. TXM
Symmetrical recycler. Supply

Mounting: T T T T
11-pole plug-in. S
DIN rail. D

Output relay:
SPDT. 1
DPDT. 2 OPTIONS
Supply voltage: Remote time adjustment. E
12V AC/DC 912 Connection for remote potentiometer. The timer is without the
24V AC/DC 924 potentiometer knob on the timer front.
24V AC 024
110/120V AC 115 Remote timer start. H 1)
220/240V AC 230 The timer is controlled from a switch or an NPN sensor instead of the
380/415V AC 400 supply voltage which must be connected permanently.
If the supply voltage is disconnected the output relay de-energizes.
Timing range:
0.1sec.-10min. L Remote timer interrupt. S 1)
1min.-100hours. H The timing period is interrupted by closing the remote control switch.
The timing resumes when the control switch is opened again.
Options:
Remote time adjustment. E Transistor output. N
Remote timer start. H 1) The open collector NPN transistor output should be used when a
Remote timer interrupt. S 1) high switching frequency is required. The transistor output may be
Transistor output. N connected to a solid state relay.
47.98

Export: United Kingdom: Germany:


Tel: +45 46 74 00 00 Tel: +44 020 8546 4283 Tel: +49 208 46954-0
Fax: +45 46 75 73 36 Fax: +44 020 8547 3628 Fax: +49 208 46954-50
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
18

txm-00.p65 2 26-10-01, 14:30


Electronic Timers
On Delay • On Pulse • Symmetrical Recycler TXM

INTRO...
TECHNICAL DATA WIRING DIAGRAMS
Time ranges: Code Time ranges Standard. Remote timer interrupt.
L 0.1-1sec. 1-10sec. 0.1-1min. 1-10min.
H 1-10min. 10-100min. 1-10hrs. 10-100hrs.

XM
- -
Z1 Z2 - -
A1 15 25 B1 B2 6
Full linearity between the ranges is provided i.e. an adjustment A1 15 25 B1 B2
5
6
7
5 7
made to a specific time in seconds will give the same time in 4 8
4 8

minutes just by operating the range switch. 3 9


3 9
2 10
2 10 16 18 26 28 A2

XW
16 18 26 28 A2 1 11
1 11
Timer accuracy: Z1 Z2
Repeating accuracy: ± 0.5% at constant conditions. Supply Supply
Supply Supply
+/L -/N +/L -/N
Setting accuracy: ± 10%. +/L -/N +/L -/N
Temperature drift: Max. 0.15% per °C.
note 2 note 1, 2

XMW
Start time: Min. 10msec.
Remote timer start.
Reset time: Max. 100msec.

Input current -

XT
(control switch): 2-3mA. B1 B2 5 7

NPN-SENSOR NPN-SENSOR

Output relay: SPDT or DPDT.


Load (cosϕ=1): Max. 5A/240V AC 2) on page 5
Min. 100mA/24VDC

XOT
+ - + -
Contact material: AgCdO.
Frequency: Max. 1000 operations per hour at max. load. A1 15 B B1 B2
5
6
7
Mechanical life time: Min. 10 x 10 6 operations. 4 8
Electrical life time: Min. 100,000 operations at max. load. 3 9
Operate and

SXM
2 10
16 18 26 28 A2 1 11
release time: Max. 20msec.
Z1 Z2
Supply Supply
Transistor output (option N only): +/L -/N +/L -/N
Load: Max. 100mA/30V DC
Frequency: Max. 18,000 operations per hour. note 1, 2

SXT
Internal power supply: Transistor output.
Voltage: Typ. 15-17V DC (9-23V depending on sup
ply voltage and load). 15V
Load: Max. 10mA (30mA with transistor output). +

TXM
Z1 Z2 - -
A1 15 25 B1 B2 6
Mounting: 5 7
+ 4 8
S1/S2: 11-pole plug-in.
D1/D2: Directly on DIN rail TS35 (EN50022). - - 3 9
2 10
16 18 26 28 A2

TXW
1 11
Terminals(D1/D2 only):Max. conductor size 4 mm2.
+ 15V
Screw type terminals with self-lifting clamps shrouded in accord- Supply Supply

ance with VDE0106 (finger and back of hand protection). +/L -/N +/L -/N

note 2
Supply voltage: 12V AC/DC (10-15V), 24V AC/DC (18-

TXT
30V), 24V AC (21.6-26.4V), 110/120V AC
(95- 135V), 220/240V AC (195-265V), 380/ MECHANICAL DIMENSIONS
415V AC (340-460V).

DC supply voltage
10
XI

rise time: Max. 20msec. (10-90% of nom. supply). 47 10

36
Mains frequency: 45-66Hz.

Consumption: 1-3VA.
XB

Cable lengths: Supply voltage: Max. 50 m.


80
45

Remote start: Max. 50 m.


Remote interrupt: Max. 1 m.
Remote pot.meter: Max. 3 m unshielded.
XWI

Max. 25 m shielded. 13 53.5 6 53.5 6

Protection: NOTES/REMARKS
S/D: IP40/IP20
1) Timers for DIN rail mounting with remote timer start or interrupt are
XIW

Isolation: only available with a single output relay.


Supply to relay Timers for plug-in mounting with remote time adjustment and timer
contacts: 2kV AC according to EN 60950 class I. start or interrupt are only available with a single output relay.
Remote timer start and interrupt cannot be combined.
Ambient temperature:-20 to +55°C. 2) The potentiometer is only used with remote time adjustment.
XIW
XF

Housing: Black Noryl SE-1.

Weight: Typically 120 g.


47.98

Export: United Kingdom: Germany:


Tel: +45 46 74 00 00 Tel: +44 020 8546 4283 Tel: +49 208 46954-0
Fax: +45 46 75 73 36 Fax: +44 020 8547 3628 Fax: +49 208 46954-50
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]