Han1 MD 6500pl Flex Terrestrial SFD v4
Han1 MD 6500pl Flex Terrestrial SFD v4
6501
DOC-1-1 Site ID: 4141
TID: HAN1MD6501PL
OSC ROADM OTS: 1 Shelf: 1
1‐25‐P2 OSID: HAN1DOM1 ROADM OTS: 1 OSC COLAN-X-IP: 10.41.88.41
Site ID: 4142 OSID: HAN1DOM1 2‐21‐P2 Shelf IP: 10.41.88.41
Tx Path ID: 2
TID: HAN1MD6502PL Tx Path ID: 1 Shelf Type: 6500 32-slot
Shelf: 1
COLAN-X-IP: 10.41.88.42 XLA SRA SRA XLA
Shelf IP: 10.41.88.42 Node ID=8841
Shelf Type: 6500 32-slot Slot 26 Slot 25 Slot 21 Slot 22 Node Name =HAN1MD6501PL
HAN1DOM1 HAN1DOM1 Type=PHOTONIC
9x1 9x1 TL1 IP Address=10.41.88.41
Node ID=8842 OOB IP Address=10.41.88.141
Node Name =HAN1MD6502PL
Flex RAMAN
Flex
Type=PHOTONIC WSS RAMAN WSS
TL1 IP Address=10.41.88.42 Slot 27 Slot 23
6503
COADM OTS: 4 DIA OTS: 5 DOC-2-1 Site ID:4143
DOC-1-2 TID: HAN1MD6503PL
OSID: n/a OSID: n/a
Shelf: 1, 2 & 3
Tx Path ID: 12 Tx Path ID: 16 OSC COLAN-X-IP: 10.41.88.43 Non OTS CD
OSC ROADM OTS: 2 ROADM OTS: 1
Shelf IP: 10.41.88.xx TID Sequence provisioning
OSID: HAN1DOM3 OSID: HAN1DOM3 2‐1‐P2
Flex SMD MLA2 1‐34‐P2
Tx Path ID: 4
Shelf Type: 6500 14-slot
Tx Path ID: 3 and two 6500 7-slot
slot 6 Slot 38 ESAM XLA
XLA ESAM
Slot 33 Slot 34 Sh 2 Slot 1 Sh 2 Slot 2 Node ID=8843
9x1 HAN1DOM3 HAN1DOM3 Node Name =HAN1MD6503PL
CCMD12
Type=PHOTONIC
Flex 5x1 5x1 TL1 IP Address=10.41.88.43
WSS 100GHz 9x1
CCMD12
100GHz OOB IP Address=10.41.88.143
Slot 36 WSS Flex
WSS
Slot 2-3 WSS
Slot 31
Slot 26
Slot 8
100GHz Slot 8
eCMD44 Slot 1‐52
100GHz
eCMD44 Slot 2‐83
DOC-3-1 DOC-1-2
DOC-1-1
DOC-1-3
ROADM OTS: 1 ROADM OTS: 1
Terrestrial/ ROADM OTS: 2
SP‐OSC OSID: HAN1DOM2
OSID: HAN1DOM4 OSID: HAN1DOM2
2xOSC ROADM OTS: 3
OSID: HAN1DOM4
Tx Path ID: 8 3‐15‐P1 Tx Path ID: 5 Submarine Link Tx Path ID: 6
1‐21‐P1 MLA2 MLA2
Tx Path ID: 7
MLA2 W/VOA Sh 1 Slot 2 HAN1DOM2/ Slot 37
MLA2 W/VOA SUB_DOM1
Sh 3 Slot 1
Slot 22 HAN1DOM4 9x1 9x1
9x1 Flex Flex
9x1 Flex WSS WSS
Flex WSS Slot 1-3 Slot 35
WSS Slot-3-2
Slot 23 HAN1DOM4
100GHz
Site ID:4144
CMD44 Slot 1‐53
6504 TID: HAN1MD6504PL
Shelf: 1
COLAN-X-IP: 10.41.88.44
Shelf IP: 10.41.88.44
100GHz
CMD44 Slot 3‐83
50GHz Red
eCMD44 Slot 1‐84
50GHz Red
eCMD44 Slot 1‐52
Shelf Type: 6500 2-slot
NETWORK
2020‐08‐31
PAGE
2 2 2
HAN1MD6502PL‐1‐25‐8
4 4
Monitor 2 Switch1 Out LC LC Switch1 In Monitor 2 Line A Mon
To:HAN1MD6502PL
OSC A Out t
u
A
SC
O
4 LC
3
Spanloss = 28.2 dB Line A In Line A Out Line A In Line A Out 3 OSC B In
Out 8 R 7 8 X 7 3 4
HAN1MD6503PL‐1‐2‐8
Distance = 140.00 Km Switch1 In 4
To:HAN1MD6503PL
Switch1 Out
ODF
ODF
Switch2 In Switch2 Out LC LC
Common In Switch3 Out LC LC Switch3 In Common Out
21 8 7 22 6 B 5 In
Loc: Shelf: 1 Slot: 21 Loc: Shelf: 1 Slot: 22 Line B In Line B Out
LC 7 8 LC
Switch3 In Switch3 Out
OTS‐1‐1
Switch5 In Switch5 Out
Switch6 Out LC LC Switch6 In
14 13
13 14
OTS‐1‐2
Switch6 In Switch6 Out
LC LC
Switch7 Out
16
LC
3
Group1 In GMD10 15
Switch7 In
15 PEC: NTT862GA 16
4
Switch7 In Group1 Out Switch7 Out
Switch8 Out LC LC Switch8 In
18 LC Group2 In 17
5
17 18
Switch8 In 6 Switch8 Out
Switch9 Out LC Group2 Out LC Switch9 In
20 LC 19
Group3 In
19 7
20
Switch9 In 8 Switch9 Out
Shelf: 1 Slot: 23 Group3 Out
Monitor Out LC Shelf: 1 Slot: 35
LC 24
Group4 In
CCMD12
LC
LC
LC
LC
LC
LC
LC
LC
LC
7 Group7 Out
12
2
10
11
14
13
16
15
18
17
20
19
Far end :
6
5
4
3
8
7
9
LC Group8 In
LC
Switch2 Out
Switch1 Out
Switch3 Out
Switch4 Out
Switch6 Out
Switch7 Out
Switch8 Out
Switch9 Out
Switch5 Out
Switch2 In
Switch1 In
Switch3 In
Switch7 In
Switch9 In
Switch4 In
Switch5 In
Switch6 In
Switch8 In
17
10
18
9 Group8 Out LC 90 89
LC LC
MUX / DEMUX
Group9 In
LC 19
12 Common In
25 20
eCMD44
6500 WSS Flex 1x9
Common Out
11
50GHz Red
Common In
Group9 Out
OPM
13 22
Group10 Out Shelf: 1 LC LC
Shelf: 1 Slot:26
1547.72 In 1556.55 Out
LC 1 46
16
Common Out
2 45
Common In
Monitor 1
Monitor 2
17 4 47
21
22
1
2
LC
LC
26
25
23 9 54
PEC: NTK508FA
CCMD12
Loc: Shelf: 1 Slot: 8
Monitor Out
10 53
Common In
21
22
19
20
17
18
15
16
13
14
11
12
10
7
8
5
6
3
4
1
2
1
LC
LC
LC
LC
LC
LC
LC
LC
LC
LC
LC
LC
NETWORK
Live Capture
DATE
2020‐08‐28 11:05:13
PAGE
HAN1MD6503PL‐2‐1‐8
Line A Mon Line A Mon Switch1 In
LC
To:HAN1MD6503PL
LC LC Switch2 Out 5
4
4
OSC B In In
B
SC
O
6
t
u
A
SC
O
OSC A Out
3 Switch2 In Spanloss = 19.11 dB
3
ODF
t
u
A
SC
O
8
Line A In Line A Out Line A In Line A Out Common In Switch3 Out LC LC LC LC LC LC
Out 8 R 7 8 X 7 21 8 7 In
Switch3 In 18 6 X 5 6 5
ODF
Common Out
LC 13
Switch6 Out
100GHz
Common In
Switch6 In
14
14
13 Shelf: 1 Slot: 52 NTT862FA Switch7 In
OTS‐1‐1 Switch6 In
Switch7 Out
Switch7 In
LC
16
15
LC
1
2
1530.33 In 1547.72 Out LC
46
45
15
16
Switch8 In
Switch9 In
PEC: NTK552FB LC
2
Monitor 2 Switch1 Out LC LC LC
1534.25 In 1551.72 Out
Line B Mon 4 11 56
1
2 3 12 55
Line A Mon Switch1 In 1534.25 Out 1551.72 In
LC Switch2 Out LC
OSC B In 3 6 LC 1535.04 In 1552.52 Out LC
13 58
HAN1MD6504PL‐1‐1‐8
4 5
To:HAN1MD6504PL
LC LC 7 15 60
LC Switch3 In
6500 WSS Flex w/OPM 1x9
LC 16 59
In 5 B 6 22 Switch4 Out 1535.82 Out 1553.33 In
Line B Out Line B In Common Out 10
9
LC 1536.61 In 1554.13 Out LC Type: WLAi FOTR w/OPS Freq:
17 62 1
Loc: Shelf: 1 Slot: 22
Switch4 In Shelf: 1 Slot:12 Port:1 P1 Rate:200G
LC 18 61 2
Switch5 Out
12 1536.61 Out 1554.13 In Far end :
11 LC 1537.40 In 1554.94 Out LC
Switch5 In 19 64
LC
OTS‐1‐3 15 eCMD44
OTS‐1‐5 1538.19 Out 1555.75 In
Common Out
Switch7 In LC LC
100GHz
Common In
LC
LC
LC
LC
LC
LC
LC
LC
LC
LC LC LC LC LC
10
12
11
14
13
16
15
18
17
20
19
1539.77 In 1557.36 Out
6
5
4
3
8
7
9
Switch9 Out 1530.33 In 1547.72 Out
20 1 46 25 70
Switch2 Out
Switch3 Out
Switch4 Out
Switch6 Out
Switch7 Out
Switch8 Out
Switch9 Out
Switch1 Out
Switch5 Out
Switch2 In
Switch1 In
Switch3 In
Switch7 In
Switch9 In
Switch4 In
Switch5 In
Switch6 In
Switch8 In
19 2 45 26 69
Switch9 In 1530.33 Out 1547.72 In 1539.77 Out 1557.36 In
Shelf: 1 Slot: 23 LC LC LC 1540.56 In 1558.17 Out LC
1531.12 In 1548.51 Out 27 72
3 48
4 47 28 71
1531.12 Out 1548.51 In 1540.56 Out 1558.17 In
6500 WSS Flex 1x9
LC LC
OPM
Type: 4XOPS SW3 Freq: LC 1531.90 In 1549.32 Out LC 1541.35 In 1558.98 Out
Shelf: 1 Slot: 5 Port: 16 Rate:
1
5 50 6500 WSS Flex w/OPM 1x9 29 74
2
1531.90 Out 1549.32 In 1541.35 Out 1558.98 In
Shelf: 1 Slot: 36
LC LC LC 1542.14 In 1559.79 Out LC
1532.68 In 1550.12 Out 31 76
7 52
Common Out
Common In
Monitor 1
Monitor 2
8 51 32 75
1532.68 Out 1550.12 In 1542.14 Out 1559.79 In
22
1
2
LC
34 77
LC
10 53
1533.47 Out 1550.92 In 1542.94 Out 1560.61 In
3
4
18 61 2 42 85
1536.61 Out 1554.13 In Far end : 1546.12 Out 1563.86 In
Line A Mon
Line B Mon
Line A Out
OSC A Out
Line B In
OSC B In
20 63 44 87
1537.40 Out 1554.94 In 1546.92 Out 1564.68 In
21 66
PEC: NTK552BA
22 65 CCMD12 LC
6500 MLA
23 68 1
Line A In
25 70
LC
26 69
50 GHz Flex SMD LC
6
1539.77 Out 1557.36 In PEC: NTK553GB
LC 5
LC 1540.56 In 1558.17 Out LC
27 72 LC
28 71 Switch1 Out LC 8 1 Type: WL5e Freq:(Flex)
1540.56 Out 1558.17 In 12
7
Shelf: 1 Slot:11 Port:11 Rate:
2
LC 1541.35 In 1558.98 Out LC 1
11 Far end :
Monitor 1
29 74 Switch1 In LC
2 Switch2 Out LC 10
30 73 Monitor 2 14
1541.35 Out 1558.98 In 9
LC LC 3 13
MUX / DEMUX
1542.14 In 1559.79 Out Monitor 3 Switch2 In LC
31 76
Switch3 Out LC LC Common In 12
32 75 4 16 25
Monitor 4 11
1542.14 Out 1559.79 In
OPM Switch3 In
15
LC
LC 1542.94 In 1560.61 Out LC 26
5 LC 14
OTS‐1‐4
37 82 17
21 27
38 81
1544.53 Out 1562.23 In
Switch6 In
Monitor Out
LC
Switch7 Out LC 20
LC 1545.32 In 1563.05 Out LC 24
39 84 Common In 19
9 23
40 83 Switch7 In LC
1545.32 Out 1563.05 In LC Switch8 Out LC 22
10 26
LC 1546.12 In 1563.86 Out LC Common Out 21
41 86 25
Switch8 In LC
42 85 LC
1546.12 Out 1563.86 In 24 NETWORK
Shelf: 1 Slot: 6 23 Live Capture
LC 1546.92 In 1564.68 Out LC
43 88 Loc: Shelf: 1 Slot: 8 DATE
44 87 2020‐08‐28 11:05:13
1546.92 Out 1564.68 In
PAGE
3
Switch2 Out
6
HAN1MD6502PL‐1‐34‐8
4 4
5
To:HAN1MD6502PL
OSC A Out t
u
A
SC
O
Switch2 In
Spanloss = 19.05 dB Line A In Line A Out Line A In Line A Out Common In
LC LC LC LC LC
7
In 5 6 5 X 6 18 Switch3 In
Line B Out Line B In Line B Out Line B In Common Out
Switch4 Out LC
10
Loc: Shelf: 2 Slot: 1 Loc: Shelf: 2 Slot: 2 9 OSC SFP 20‐34dB
Switch4 In Out
PEC: NTK592NH
Switch5 Out LC In
12 Loc: Shelf: 1 Slot: 1.1
11 6500 WSS Flex 1x9
OTS‐2‐1 Switch5 In
Switch6 In
Switch7 In
13
14
LC
PEC: NTK553LA
OPM
Monitor 1
Monitor 2
LC
1
2
Switch1 In
15
Switch8 In
3
6500 MLA2
4
Switch9 In
16
Switch1 Out LC PEC: NTK552FA
LC Switch2 In 1
Line B Mon
OSC SFP 0‐15dB In Loc: Shelf: 2 Slot: 3 5
PEC: NTK592NP Out
2
Line A Mon
6
Loc: Shelf: 3 Slot: 15.1 Switch2 Out LC
LC Switch3 In Common Out 3 OSC B In
HAN1MD6501PL‐1‐37‐8
7 22
4
To:HAN1MD6501PL
8 OSC A Out
LC
6500 MLA2v 6500 WSS Flex 1x9 Switch3 Out Spanloss = 14.73 dB
ODF
LC LC LC
Line B Mon Monitor 1
1 1 10
OPM Switch4 Out 6 B 5 In
2 2 LC Line B In
Line A Mon Monitor 2 LC Switch5 In Line B Out
Switch1 Out
LC 4 11
OSC B In 3
3 12 Loc: Shelf: 1 Slot: 2
Switch5 Out
HAN1MD6504PL‐1‐2‐8
4 Switch1 In LC
To:HAN1MD6504PL
Switch6 Out
LC LC Switch2 In
LC
LC Switch7 In
OTS‐1‐1
Common In Switch3 Out
In 5 B 6 21 8 15
Line B Out Line B In
7 16
LC Switch3 In Switch7 Out
6500 WSS Flex w/OPM 1x9
9 18
Switch4 In Switch8 Out
LC LC Switch9 In
Switch5 Out LC 90 89
12 19
11 20
Switch9 Out
CMD44
OTS‐3‐1
Switch5 In
Switch6 Out LC Shelf: 1 Slot: 3
Common Out
14
100GHz
Common In
13 Shelf: 2 Slot: 83
Switch6 In NTT862AA
Switch7 Out LC
16
LC 1530.33 In 1547.72 Out LC
15 1 46
Switch7 In
Switch8 Out LC 2 45
18 1530.33 Out 1547.72 In
Common Out
Switch9 In
LC 90 89 1 5 50
50GHz Red
Common In
Shelf: 3 Slot: 2 Shelf: 1 Slot: 5 Port: 14 Rate:
6 49
Far end:100G OTR Shelf: 1 Slot: 7 Port: 1 2
1531.90 Out 1549.32 In Shelf: 1 Slot: 84 NTT862BD
CMD44 LC 1532.68 In 1550.12 Out LC
Common Out
100GHz LC LC
Common In
1
11 56 13 58
20 63 Shelf: 1 Slot:9-1 Port: Rate:
1537.40 Out 1554.94 In
12 55 Far end: 2 14 57
1534.25 Out 1551.72 In LC LC 1550.12 Out 1558.98 In
1538.19 In 1555.75 Out
LC 1535.04 In 1552.52 Out LC 21 66
Type: PXFP Freq: LC 1550.52 In 1559.39 Out LC
1
13 58 15 60
22 65 Shelf: 1 Slot:14-5 Port: Rate:
1538.19 Out 1555.75 In
14 57 Far end: 2 16 59
1535.04 Out 1552.52 In LC LC 1550.52 Out 1559.39 In
1538.98 In 1556.55 Out
LC 1535.82 In 1553.33 Out LC 23 68
Type: PXFP Freq: LC 1550.92 In 1559.79 Out LC
1
15 60 17 62
24 67 Shelf: 1 Slot:14-6 Port: Rate:
1538.98 Out 1556.55 In
16 59 Far end: 2 18 61
1535.82 Out 1553.33 In LC LC 1550.92 Out 1559.79 In
1539.77 In 1557.36 Out
LC LC 25 70
Type: PXFP Freq: LC LC
17
1536.61 In 1554.13 Out
62 1 Type: WLAi FOTR w/OPS Freq: 1
19
1551.32 In 1560.20 Out
64
Shelf: 1 Slot:12 Port:1 P2 Rate:200G 26 69 Shelf: 1 Slot:14-7 Port: Rate:
6500 MLA2v
PEC: NTK552FB LC
Line B Mon
1 6500 LIM
Line A Mon
2
LC PEC: NTK552DA
LC 1
Line B Mon
OSC B In 3
2
HAN1MD6502PL‐1‐22‐8
4 Line A Mon
To:HAN1MD6502PL
OSC A Out LC
Spanloss = 3.65 dB 3 OSC B In
Line A In Line A Out
8 A 7
HAN1MD6503PL‐3‐1‐8
Out Distance = 0.00 Km
To:HAN1MD6503PL
4
ODF
LC LC OSC A Out
Line A Out Line A In Spanloss = 9.88 dB Out
In 5 B 6 7 8
Line B In Distance = 0.00 Km
ODF
Line B Out
LC LC
6 5 In
Loc: Shelf: 1 Slot: 1 Line B In Line B Out
OTS‐1‐1
OTS‐1‐2
NETWORK
Live Capture
DATE
2020‐08‐28 11:05:13
PAGE
Working
CMD44 HAN1MD6502BBPL‐1‐52 CMD44 HAN1MD6503BBPL‐2‐83
OPS3 OPS3
Protect
LC
LC
0 0
Rx Tx Rx Tx
Loc: HAN1MD6502PL Sh: 1 Sl: 35 Port: 1
0
0