TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
ENCRAFT INDIA PVT.LTD.
ADDRESS: WORKS: KHASRA NUMBER 1000-1001, BEEHIVE COLLEGE ROAD,
JAMANPUR, CENTRAL HOPE TOWN, SELAQUI INDUSTRIAL AREA,
CONTACT PERSON : VIRAG BAGADE
THE FOLLOWING SAMPLE(S) WAS/WERE SUBMITTED AND IDENTIFIED BY/ON BEHALF OF THE CUSTOMER
AS :
SAMPLE DESCRIPTION : UPVC PROFILE
COLOUR : WHITE
MATERIAL : UPVC
PART/ REF.NO. : 32010090101
COUNTRY OF DESTINATION : INDIA
COUNTRY OF ORIGIN : INDIA
SAMPLE RECD ON : 12 Oct-2020
TESTING PERIOD : 12 Oct-2020 to 16-Oct-2020
TEST(S) REQUESTED : ROHS 10E
CONCLUSION: Based on the performed tests on submitted sample(s), the results of Cadmium,Lead,Mercury,Hexavalent chromium,
Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs), Dibutyl Phthalate (DBP), Butyl
benzyl Phthalate (BBP), Bis (2-ethylhexyl) Phthalate (DEHP), Diisobutyl Phthalates (DIBP) Comply with the limits
as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. .
Per Pro SGS India Private Ltd
__________________
Authorized Signatory
Kapil Patil
Manager -RSL-HL/EE
Email your Test Report Related Enquiries at: [email protected]
JOE No. : 2051800934 Page 1 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Test Part Description:
Product No.
Sample No. Material Description Remarks
1 1 UPVC PROFILE --
Remarks:
(1) 1mg/kg=0.0001%
(2) MDL = Method Detection Limit
(3) ND = Not Detected (<MDL)
(4) - = not regulated
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU
Test Method:
(1) With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2) With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3) With reference to IEC 62321-4:2013+A1:2017 determination of Mercury by ICP-OES.
(4) With reference to IEC 62321-7-2:2017, determination of Hexavalent Chromium by Colorimetric Method
using UV-Vis and/or with reference to IEC 62321-5:2013, determination of Chromium by ICP-OES.
(5) With reference to IEC 62321-6:2015, determination of PBBs and PBDEs by GC-MS.
(6) With reference to IEC 62321-8:2017, determination of Phthalates by GC-MS.
JOE No. : 2051800934 Page 2 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Test result:
Test Item(s): Unit Results MDL Limit
Sample -1
Cadmium(Cd) mg/kg ND 5 100
Lead (Pb) mg/kg 10 5 1000
Mercury (Hg) mg/kg ND 5 1000
Hexavalent Chromium (CrVI) mg/kg ND 8 1000
Sum of PBBs mg/kg ND - 1000
Monobromobiphenyl mg/kg ND 50 -
Dibromobiphenyl mg/kg ND 50 -
Tribromobiphenyl mg/kg ND 50 -
Tetrabromobiphenyl mg/kg ND 50 -
Hexabromobiphenyl mg/kg ND 50 -
Pentabromobiphenyl mg/kg ND 50 -
Heptabromobiphenyl mg/kg ND 50 -
Octabromobiphenyl mg/kg ND 50 -
Nonabromobiphenyl mg/kg ND 50 -
Decabromobiphenyl mg/kg ND 50 -
Sum of PBDEs mg/kg ND - 1000
Monobromodiphenyl ether mg/kg ND 50 -
Dibromodiphenyl ether mg/kg ND 50 -
Tribromodiphenyl ether mg/kg ND 50 -
Tetrabromodiphenyl ether mg/kg ND 50 -
Pentabromodiphenyl ether mg/kg ND 50 -
Hexabromodiphenyl ether mg/kg ND 50 -
Heptabromodiphenyl ether mg/kg ND 50 -
Octabromodiphenyl ether mg/kg ND 50 -
Nonabromodiphenyl ether mg/kg ND 50 -
Decabromodiphenyl ether mg/kg ND 50 -
Dibutyl phthalate (DBP) mg/kg ND 100 1000
Butyl benzyl phthalate (BBP) mg/kg ND 100 1000
Bis (2-ethylhexyl) phthalate (DEHP) mg/kg ND 100 1000
Diisobutyl Phthalates (DIBP) mg/kg ND 100 1000
JOE No. : 2051800934 Page 3 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Notes:
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
IEC 62321 series is equivalent to EN 62321 series
http://www.cenelec.eu/dyn/www/f?p=104:30:1742232870351101::::FSP_ORG_ID,FSP_LANG_ID:1258637,25
(2) Test has been performed on composite parts as per client’s request
(3) The result of Hexavalent Chromium (Cr(VI)) is “ND” as the result of Chromium (Cr) is “ND”, and confirmation test of
Hexavalent Chromium (Cr(VI)) is not required.
(4) If the Chromium (Cr) content is greater than the MDL of of Hexavalent Chromium (Cr(VI)), confirmation test of
Hexavalent Chromium (Cr(VI)) is required.
(5) On 4 June 2015, Commission Directive (EU) 2015/863 was published in the Official Journal of the European Union
(OJEU) to include the phthalates BBP, DBP, DEHP and DIBP into ANNEX II of the Rohs Recast Directive. The new
law restricts each phthalate to no more than 0.1% in each homogeneous material of an electrical product.
(6) The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and
monitoring and control instruments, including industrial monitoring and control instruments, from 22 July 2021.
(7) The restriction of DEHP, BBP, DBP and DIBP shall not apply to cables or spare parts for the repair, the reuse, the
updating of functionalities or upgrading of capacity of EEE placed on the market before 22 July 2019, and of
medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial
monitoring and control instruments, placed on the market before 22 July 2021.
(8) The restriction of DEHP, BBP and DBP shall not apply to toys which are already subject to the restriction of DEHP,
BBP and DBP through entry 51 of Annex XVII to Regulation (EC) No 1907/2006.
JOE No. : 2051800934 Page 4 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Process Flow for analysis of metal contents in plastics, metals and electronic components sample
Sample preparation,
0.25 – 0.30 g
< 2×2×2 mm3
Microwave Digestion NO YES Microwave Digestion
System Si- based System
10 ml conc. HNO3 sample 10 ml HNO3 + 0.5 ml HF
Cool down
Cool down
Add 0.25 g
orthoboric acid
Filtration
25 ml final volume
ICP-OES/MS
Analyzed By : Md. Taqi Checked By : Bikram Deo Ohdar
JOE No. : 2051800934 Page 5 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Process Flow for analysis of Hexachromium contents in plastics, metals and electronic components sample
Sample
Non Metallic Metallic Sample
Sample
Pretreatment Positive
For solvent soluble For insoluble/unknown polymer Spot Test
polymers(ABS, PC & PVC) & electronics without Sb
Negative
Add NMP solvent for dissolution Added mixture of Toluene and Boiling water
followed by addition of digestion digestion solution extraction
soltuion
Dissolve polymer by Microwave digestion at 150°C Adding 1,5-diphenylcarbazide for
Ultrasonication at 60°C for 1hr for 1.5hr color development
Adjust the pH using Nitric acid. Add 1,5-
diphenylcarbazide for color development Red Color indicate presence of
Hexachromium. If necessary
confirm with UV-Vis
Analysis on UV-Vis Spectorphtometer
Spectorphtometer
Data
Analyzed By: Sanjit Mandal Checked By : Bikram Deo Ohdar
JOE No. : 2051800934 Page 6 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Process Flow for analysis of Flame Retardants in plastics, metals and electronic components sample
Sample
Sample Pretreatment
Soxhlet extraction
IEC 62321-6:2015
Concentrate/Dilute
Extracted solution
Filter if necessary
On High Mass Range GCMS-
Sample Analyzed
Analyzed By: Parvez Alam Siddiqui Checked By :Vijai Chauhan
JOE No. : 2051800934 Page 7 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Process Flow for analysis of Phthalates in Electrotechnical Product As per soxhelt Extraction or THF Extraction:
Sample
Non soluble sample Soluble sample
Pretreatment
Sample Pretreatment
Sample Pretreatment
Addition THF
Soxhlet extraction with n-hexane
IEC 62321-8:2017
Sonication at ultrasonic bath for 30
to 60 min
Concentrate/Dilute
Addition of Acetonitrile
Filter if necessary Filter if necessary
On GCMS-Sample Analyzed
On GCMS-Sample Analyzed
Data
Analyzed By: Parvez Alam Siddiqui Checked By :Vijai Chauhan
JOE No. : 2051800934 Page 8 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)
TEST REPORT
Report No. : BG:EE: 1151002703 DATE : 16-Oct-2020
*1151002703*
Sample Photo :1151002703
SGS authenticate the photo on original report only
*** End of Report ***
JOE No. : 2051800934 Page 9 of 9 Control No.1151502464
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/terms
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this
document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be
reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this
document is unlawful and offenders may be prosecuted to the fullest extent of the law.” Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.
Consumer and Retail,Testing Laboratory,226,Udyog Vihar,Phase- I,Gurugram-122016,Haryana,India.t:(91-124) 6135000/6776300 www.sgs.com
SGS India Pvt. Ltd
Member of the SGS Group (SGS SA)