0% found this document useful (0 votes)
73 views6 pages

Flow Meter

The Smith Meter Model E3 is a 3" rotary vane type positive displacement meter designed for various applications including blending, batching, and custody transfer of liquids. It features superior accuracy, low pressure drop, and long service life, with options for high viscosity and temperature clearances. The document provides detailed specifications, operating conditions, and ordering information for the meter.

Uploaded by

zj84k9jcts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views6 pages

Flow Meter

The Smith Meter Model E3 is a 3" rotary vane type positive displacement meter designed for various applications including blending, batching, and custody transfer of liquids. It features superior accuracy, low pressure drop, and long service life, with options for high viscosity and temperature clearances. The document provides detailed specifications, operating conditions, and ordering information for the meter.

Uploaded by

zj84k9jcts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

SPECIFICATIONS

3" Steel Model E3 PD Meter


Bulletin SS01016 Issue/Rev. 1.2 (2/17)

Smith Meter® PD Meters


The Smith Meter Model E3 is a 3", double-case,
straight-through (S1 through S8), rotary vane type
positive displacement meter. Applications include:
blending, batching, dispensing, inventory control, and
custody transfer of oils, solvents, chemicals, paints,
fats and fertilizers.

Features
»» Superior Accuracy – The Smith Meter
Rotary Vane Meter principle, combined with
the meter’s uniquely designed (offset) inlet
Model E3-S1
and outlet nozzles, minimizes pressure drop
across the measuring chamber, which
reduces flow through meter clearances
to maximize accuracy. Operating Specifications
»» Low Pressure Drop – Streamlined flow path
Maximum Flow Rate
provides low pressure drop.
USGPM L/min
»» Positive and Accurate Registration – High
Continuous Rating -
torque drive calibrator with adjustment in 0.05% 420 1,600
Standard Trim
increments ensures accurate registration. Intermittent Rating - (S1 only)
500 1,900
»» Long Service Life – Low friction ball bearings, Standard Trim

fixed cam-type timing, and rugged construction Continuous/ Intermittent


315 1,200
Rating - All Iron or LPG Trim
give sustained accuracy and long service life.

Minimum Flow Rate


Typical Performance
Options
Viscosity (Centipoise – mPa•s)
»» High Viscosity Meter Clearances – To extend Linearity1 Units .5 1 5 20 100 400
operation at maximum flow rate from 400 mPa•s US- 80 50 20 5 1 0.25
to 2,000 mPa•s. ±0.15% GPM
»» High Temperature Clearances – To extend operating L/min 303 190 75 19 4 1
temperatures from 150°F to 200°F (65°C to 93°C). US- 50 35 15 4 0.8 0.20
»» All Iron Trim – For operating temperatures above ±0.25% GPM
200°F (93°C). L/min 190 132 57 15 3 0.8
»» LPG Trim – For low lubricity liquids such as LPG. US- 40 25 10 2.4 .05 0.13
»» NACE Construction – Special components available ±0.50% GPM
to meet requirements of NACE Standard MR-01-75. L/min 150 95 38 10 2 0.5

1 Linearity based on a maximum flow rate of 420 USGPM


(1,600 L/min) unless otherwise stated.
Repeatability Pressure Drop (∆P)
±0.02%
Flo w - L/min
200 600 1,000 1,400 1,800
Viscosity 5.0
Data ba se d on 0.82 s p. gr., 30
Standard: 400 mPa•s2 (2,000 SSU) maximum. 4.0 2 m Pa •s product.
25
Optional: 2 Pa•s (10,000 SSU) maximum – specify
“High Viscosity Meter Clearances.” 3.0 20
ΔP ΔP
Over 2 Pa•s – specify “High Viscosity Meter p si 15 kPa
2.0
Clearances” and derate maximum flow rate in direct
10
proportion to viscosity over 2 Pa•s (e.g., at 4 Pa•s, 1.0
derate Maximum Flow Rate to 50% of Normal 5
0
Continuous Rating - 210 USGPM). 0 100 200 300 400 500
Flo w - US GP M

Temperature
Standard Meter Clearances with:
Buna-N / PTFE7: -20°F to 150°F (-29°C to 65°C).
Viton: 10°F to 150°F (-12°C to 65°C). Materials of Construction
High Temperature Meter Clearances with: Trim Housing Internals Seals
Buna-N / PTFE7: -20°F to 200°F (-29°C to 93°C). Iron, Steel, Stainless Buna N5, Viton,
Standard Steel
Viton: 10°F to 200°F (-12°C to 93°C). Steel, Aluminum or PTFE7

All Iron Trim with: Iron, Steel, Stainless


Buna N5, Viton,
LPG Steel Steel, Aluminum,
or PTFE7
Buna-N: -20°F to 225°F (-29°C to 108°C). Rulon and Nylon
PTFE7: -20°F to 400°F (-29°C to 205°C). Iron, Steel, Stainless Buna N5, Viton,
All Iron Steel
Steel or PTFE7
Viton: 10°F to 400°F (-12°C to 205°C).

Meter Gearing Installation


Five U.S. gallons or one dekaliter per revolution of meter It is recommended that the meter be protected with a suit-
calibrator output shaft. able mesh strainer.

One barrel – special.

Maximum Working Pressure Approvals


Model Flange PSI kPa6 INMETRO/DIMEL No. 0148
E3-S1 150 150 1,034
E3-S3 150 2853 1,9653
E3-S5 300 300 2,068
E3-S6 300 740 3
5,1023
E3-S7 600 1,4803 10,2043
E3-S8 900 2,220 3
15,3063

Flange Class per ANSI B16.5 Raised Face Flange.

2 1,000 mPa•s = 1,000 cP = 1 Pa•s.


3 Maximum W.P. at 100°F (38°C).
4 All S3 through S8 meters with Viton trim have PTFE packing gland seals.
5 Standard.
6 See Catalog Code for more options.
7 Polytetrafluoroethylene (PTFE).

2 Bulletin SS01016 Issue/Rev. 1.2 (2/17)


Catalog Code

The following guide defines the correct PD meter for a given application and the respective catalog code. This code is part of the
ordering information and should be included on the purchase order.

1 2 3 4 5 6 7 8 9 10
K E 3 S 1 G B S 0 0

Position 1: Code Position 6: Meter Gearing


K - Catalog Code G - Gallons (5:1 - S1)
B - Barrels (1:1 - S3 through S8)
Positions 2 and 3: Model/Flange Size D - Dekaliters (1:1 - S1 through S8)
E3 - 3" I - Imperial Gallons8
P - Pound8
Position 4: Flow Path
Position 7: Seals
S - Straight
B - Buna-N
V - Viton
Position 5: Pressure Class and End Connections
T - PTFE7

Standard (Raised Face Flanges)


Position 8: Trim
1 - Class 150, 150 psig/1,034 kPa
3 - Class 150, 285 psig/1,965 kPa S - Standard
5 - Class 300, 300 psig/2,068 kPa A - All Iron
6 - Class 300, 740 psig/5,102 kPa L - LPG
7 - Class 600, 1,480 psig/10,204 kPa
8 - Class 900, 2,220 psig/15,306 kPa Position 9: Temperature Compensation
PED (Raised Face Flanges) 0 - None
1 - Class 150, Not Available A - ATC
3 - Class 150, 285 psig/1,965 kPa B - ATG
5 - Class 300, Not Available
6 - Class 300, 740 psig/5,102 kPa Position 10: Special Requirements9
7 - Class 600, Consult Factory
0 - Standard
All Flanges designed to ANSI B16.5, pressure ratings maximum P - PED (consult factory)
working pressure at 100°F. C - CRN

7 Polytetrafluoroethylene (PTFE).
8 Consult factory for Model number when selecting Imperial or Pound Gearing.
9 PED required for all European countries. The equipment must be
manufactured by Ellerbek, Germany facility.

Bulletin SS01016 Issue/Rev. 1.2 (2/17) 3


Dimensions
Inches (millimeters)

Note: Dimensions – inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from
respective engineering drawings.

Model E3-S1 through S5 Model E3-S6 through S8 Meter Anchor Bolt Holes
3 - 0.8" (20) Bolt Holes on a
13" (330) Diameter Bolt Circle

Model A B C D E Weight - lb (kg)


E3-S1 18.5" (470) 8.1" (206) 21.3" (540) 8.9" (226) 17.8" (451) 265 (120)
E3-S3 18.5" (470) 8.1" (206) 22.5" (572) 8.9" (226) 17.8" (451) 270 (122)
E3-S5 19.5" (495) 8.1" (206) 22.5" (572) 9.3" (236) 17.8" (451) 285 (129)
E3-S6 23.0" (584) 8.5" (216) 25.0" (635) 9.3" (236) 18.7" (475) 435 (197)
E3-S7 23.3" (592) 8.8" (224) 25.8" (655) 9.3" (236) 19.4" (492) 660 (299)
E3-S8 27.3" (691) 15.8" (400) 33.9" (860) 14.0" (355) 28.0" (711) 1,265 (573)

ORDERING INFORMATION
Application Batching, Loading, Blending, Inventory, Process Control, etc.
Operating Conditions Liquid – Name, Specific Gravity or API Gravity, Flow Range10, Temperature Range10, Viscosity Range10,
Maximum Working Pressure
Seals Buna N11, Viton, or PTFE7.
Units of Registration Gallons, Barrels, Liters, Dekaliters, Pounds, Kilograms, etc.
Direction of Flow Left-to-right (as viewed above) is standard and will be supplied unless right-to-left flow is specified.
Style Straight-through
Options and Accessories As required.

7 Polytetrafluoroethylene (PTFE).
10 Specify: minimum/normal/maximum.
11  Standard seals supplied unless optional material specified.

4 Bulletin SS01016 Issue/Rev. 1.2 (2/17)


Accessories
Strainer Pulse Transmitters
3" steel, R.F. flanged. Type E – SPDT Mercury Wetted Switch.
LNC Pulse Transmitter (adapts to 600 Series Counters).
Mechanical Preset Valves
Low-Resolution – 1 to 10 pulses12.
3" straight-through type, steel, flanged, 300 psi maximum
High-Resolution (HR) – 50 or 100 pulses12.
working pressure.
UPT – Quad-channel, infrared, security pulse transmitter in an
Air Eliminator explosion-proof housing (up to 1,000 pulses/rev.).
3" steel, R.F. flanged, 300 psi maximum working pressure.
Flow Rate Indicator
Hydraulic Valves Direct Mount Mechanical.
3" globe-type, steel, R.F. flanged, 300 psi maximum work- Remote Electronic.
ing pressure.
Remote Registration
Counters Electro-Mechanical Counters.
200 Series – Accumulative, nine-digit, non-reset type. Electronic Totalizers.
600 Series – Five large digit reset, eight small digit non-
Automatic Temperature Compensation
reset.
Model ATC – Factory-set for a given product.
Printer Model ATG – Field-adjustable for different products.
Seven-digit accumulative. Model LEATC – Electronic, field-programmable for
Optional six-digit zero start. different products.

Preset Counter
300C Series – four-digit (five-digit optional) mechanical
pushbutton preset with valve linkage. Microswitch pack-
age for hydraulic valve, pump control, or other interlock
optional.

12 Per revolution of LNC Right-Hand Wheel.

Bulletin SS01016 Issue/Rev. 1.2 (2/17) 5


Revisions included in SS01016 Issue/Rev. 1.2 (2/17):
Information expanded upon for Position 6/D. Rebranded. Page number shift may have occurred compared to previous version.
The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in
effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.
Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the “Contact Us” link
in the left-hand column.

USA Operation
1602 Wagner Avenue
TechnipFMC Erie, Pennsylvania 16510 USA
P:+1 814.898.5000
FMC Technologies
Measurement Solutions, Inc. Germany Operation
500 North Sam Houston Parkway West, Smith Meter GmbH
Suite 100 Regentstrasse 1
TechnipFMC.com
Houston, Texas 77067 USA 25474 Ellerbek, Germany
Copyright © TechnipFMC 2017 All rights reserved. SS01016 rev. 1.2 (2/17) P:+1 281.260.2190 P:+49 4101 304.0