0% found this document useful (0 votes)
37 views16 pages

Bo-nguon-Omron-S8JC-Z-catalog 12092016035946

The document introduces the S8JC-Z and S8JC-ZS series of Switch Mode Power Supplies, highlighting their CE marking and various power ratings ranging from 15W to 350W. These power supplies are designed for cost reduction, safety compliance, and easy DIN-rail installation. The S8JC-ZS series offers enhanced reliability with improved operating temperature and dielectric strength.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views16 pages

Bo-nguon-Omron-S8JC-Z-catalog 12092016035946

The document introduces the S8JC-Z and S8JC-ZS series of Switch Mode Power Supplies, highlighting their CE marking and various power ratings ranging from 15W to 350W. These power supplies are designed for cost reduction, safety compliance, and easy DIN-rail installation. The S8JC-ZS series offers enhanced reliability with improved operating temperature and dielectric strength.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

New Product

Switch Mode Power Supply


S8JC-Z / S8JC-ZS

S8JC-ZS, newly released Power Supply with CE marking,


additional models for economical Power Supply, S8JC-Z series.
S8JC-Z/S8JC-ZS is our best standard power
supply for
• material cost reduction
• export machines, required safety standard
• time saving for installation by DIN-rail mounting

Model Number Structure


Model Number Legend
Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2.

S8JC-Z@@@@@@@@-@@@
1 2 3 4 5 6

1. Conformed standards 2. Power Ratings 3. Output Voltage 4. Configuration 5. Configuration/mounting


None: no standard 015: 15 W 05: 5 V C: Covered None: Bottom-mounting
S: CE (EN50178) 035: 35 W 12: 12 V D: DIN Rail-mounting
050: 50 W 24: 24 V
100: 100 W 48: 48 V 6. Input Voltage
150: 150 W None/AC2: 200 to 240 VAC
350: 350 W

Line-up & Feature


S8JC-Z series (15/35/50/100/150/350-W models)
Power ratings
Voltage
15 W 35 W 50 W 100 W 150 W 350 W

5V ● ● ● ● ● New
For More application !
12 V ● ● ● ● ● New  More Output Voltage Specifications from 5 V to 48 V
 Various power rating range from 15 W to 350 W
24 V ● ● ● ● ● ●

48 V ● ● ● ● ● —

S8JC-ZS series (15/35/50/100/150-W models)


Power ratings
Voltage
15 W 35 W 50 W 100 W 150 W 350 W
For More reliability !
5V ● ● ● ● ● New  Conformed to CE marking
 Expanded operating temperature: 20C to +70C
12 V ● ● ● ● ● New  Improved Dielectric strength

24 V ● ● ● ● ● New

1
S8JC-Z
Ordering Information
List of Models in S8JC-Z Series
Note: For details on normal stock models, contact your nearest OMRON representative.
Conformed
Configuration Input voltage Power ratings Output voltage Output current Model
standard
5 VDC 3.0 A S8JC-Z01505C
12 VDC 1.3 A S8JC-Z01512C
15 W
24 VDC 0.7 A S8JC-Z01524C
48 VDC 0.35 A S8JC-Z01548C
5 VDC 7.0 A S8JC-Z03505C
12 VDC 3.0 A S8JC-Z03512C
35 W
24 VDC 1.5 A S8JC-Z03524C
48 VDC 0.75 A S8JC-Z03548C
5 VDC 10.0 A S8JC-Z05005C
12 VDC 4.2 A S8JC-Z05012C
50 W
24 VDC 2.1 A S8JC-Z05024C
Bottom-mounting 48 VDC 1.1 A S8JC-Z05048C
5 VDC 20.0 A S8JC-Z10005C
12 VDC 8.5 A S8JC-Z10012C
100 W
24 VDC 4.5 A S8JC-Z10024C
48 VDC 2.3 A S8JC-Z10048C
5 VDC 30.0 A S8JC-Z15005C
12 VDC 12.5 A S8JC-Z15012C
150 W
24 VDC 6.5 A S8JC-Z15024C
48 VDC 3.3 A S8JC-Z15048C
5 VDC 50.0 A S8JC-Z35005C
350 W 12 VDC 29.0 A S8JC-Z35012C
Covered Power 24 VDC 14.6 A S8JC-Z35024C
None 200 to 240 VAC
Supplies 5 VDC 3.0 A S8JC-Z01505CD
12 VDC 1.3 A S8JC-Z01512CD
15 W
24 VDC 0.7 A S8JC-Z01524CD
48 VDC 0.35 A S8JC-Z01548CD
5 VDC 7.0 A S8JC-Z03505CD
12 VDC 3.0 A S8JC-Z03512CD
35 W
24 VDC 1.5 A S8JC-Z03524CD
48 VDC 0.75 A S8JC-Z03548CD
5 VDC 10.0 A S8JC-Z05005CD
12 VDC 4.2 A S8JC-Z05012CD
50 W
24 VDC 2.1 A S8JC-Z05024CD
DIN Rail-
48 VDC 1.1 A S8JC-Z05048CD
mounting
5 VDC 20.0 A S8JC-Z10005CD
12 VDC 8.5 A S8JC-Z10012CD
100 W
24 VDC 4.5 A S8JC-Z10024CD
48 VDC 2.3 A S8JC-Z10048CD
5 VDC 30.0 A S8JC-Z15005CD
12 VDC 12.5 A S8JC-Z15012CD
150 W
24 VDC 6.5 A S8JC-Z15024CD
48 VDC 3.3 A S8JC-Z15048CD
5 VDC 50.0 A S8JC-Z35005CD
350 W 12 VDC 29.0 A S8JC-Z35012CD
24 VDC 14.6 A S8JC-Z35024CD

2
S8JC-Z

List of Models in S8JC-ZS Series


Note: For details on normal stock models, contact your nearest OMRON representative.
Comformed
Configuration Input voltage Power ratings Output voltage Output current Models
standard
5 VDC 3.0 A S8JC-ZS01505C-AC2
15 W 12 VDC 1.3 A S8JC-ZS01512C-AC2
24 VDC 0.7 A S8JC-ZS01524C-AC2
5 VDC 7.0 A S8JC-ZS03505C-AC2
35 W 12 VDC 3.0 A S8JC-ZS03512C-AC2
24 VDC 1.5 A S8JC-ZS03524C-AC2
5 VDC 10.0 A S8JC-ZS05005C-AC2
50 W 12 VDC 4.2 A S8JC-ZS05012C-AC2
24 VDC 2.1 A S8JC-ZS05024C-AC2
Bottom-mounting
5 VDC 20.0 A S8JC-ZS10005C-AC2
100 W 12 VDC 8.5 A S8JC-ZS10012C-AC2
24 VDC 4.5 A S8JC-ZS10024C-AC2
5 VDC 30.0 A S8JC-ZS15005C-AC2
150 W 12 VDC 12.5 A S8JC-ZS15012C-AC2
24 VDC 6.5 A S8JC-ZS15024C-AC2
5 VDC 60.0 A S8JC-ZS35005C-AC2
350 W 12 VDC 29.0 A S8JC-ZS35012C-AC2
Covered Power 24 VDC 14.6 A S8JC-ZS35024C-AC2
CE (EN50178) 200 to 240 VAC
Supplies 5 VDC 3.0 A S8JC-ZS01505CD-AC2
15 W 12 VDC 1.3 A S8JC-ZS01512CD-AC2
24 VDC 0.7 A S8JC-ZS01524CD-AC2
5 VDC 7.0 A S8JC-ZS03505CD-AC2
35 W 12 VDC 3.0 A S8JC-ZS03512CD-AC2
24 VDC 1.5 A S8JC-ZS03524CD-AC2
5 VDC 10.0 A S8JC-ZS05005CD-AC2
50 W 12 VDC 4.2 A S8JC-ZS05012CD-AC2
DIN Rail- 24 VDC 2.1 A S8JC-ZS05024CD-AC2
mounting 5 VDC 20.0 A S8JC-ZS10005CD-AC2
100 W 12 VDC 8.5 A S8JC-ZS10012CD-AC2
24 VDC 4.5 A S8JC-ZS10024CD-AC2
5 VDC 30.0 A S8JC-ZS15005CD-AC2
150 W 12 VDC 12.5 A S8JC-ZS15012CD-AC2
24 VDC 6.5 A S8JC-ZS15024CD-AC2
5 VDC 60.0 A S8JC-ZS35005CD-AC2
350 W 12 VDC 29.0 A S8JC-ZS35012CD-AC2
24 VDC 14.6 A S8JC-ZS35024CD-AC2

3
S8JC-Z
Ratings, Characteristics, and Functions
15-/35-W Models
Power ratings 15 W 35 W
Item Series name S8JC-Z S8JC-ZS S8JC-Z S8JC-ZS
Certification --- CE (EN50178) --- CE (EN50178)
Output voltage (VDC) 5V 12 V 24 V 48 V 5V 12 V 24 V 5V 12 V 24 V 48 V 5V 12 V 24 V
Output current 3.0 A 1.3 A 0.7 A 0.35 A 3.0 A 1.3 A 0.7 A 7.0 A 3.0 A 1.5 A 0.75 A 7.0 A 3.0 A 1.5 A
Voltage adjustment 10% to 10% 10% to 10%
Output range (typical)
Ripple (typical) 100 mV 200 mV 70 mV 60 mV 50 mV 100 mV 150 mV 200 mV 40 mV 100 mV 100 mV
Startup time (typical) 300 ms 260 ms 270 ms 300 ms 300 ms 240 ms 260 ms 300 ms
Hold time (typical) 50 ms 50 ms 65 ms 50 ms 30 ms 30 ms 35 ms 40 ms
Efficiency (typical) 74% 80% 86% 76% 80% 75% 82% 84% 88% 76% 83% 84%
Voltage 200 to 240 VAC (185 to 264 VAC) 200 to 240 VAC (185 to 264 VAC)
Frequency 50/60 Hz
50/60 Hz (47 to 64 Hz) 50/60 Hz (47 to 64 Hz)
(47 to 63 Hz)
Current (typical) 0.22 A 0.5 A
Input
Leakage current 1 mA max. 1 mA max.
Inrush current (for a
cold start at 25C) 40 A 40 A
(typical)
105% of rated load current, voltage drop, intermittent, automatic 105% of rated load current, voltage drop, intermittent, automatic
Overload protection
reset reset
Additional Overvoltage protection Yes Yes
functions
Parallel operation No No
Series operation No No
Ambient operating
temperature
*10C to 60C *20C to 70C *10C to 60C *20C to 70C
*Refer to the derating curve
in Engineering Data
Between
all inputs
1.5 kVAC for 1 min. 3 kVAC for 1 min. 1.5 kVAC for 1 min. 3 kVAC for 1 min.
and
outputs
Dielectric
Between
strength
all inputs
(detection 1.5 kVAC for 1 min. 2 kVAC for 1 min. 1.5 kVAC for 1 min. 2 kVAC for 1 min.
and PE
current:
terminals
20 mA)
Between
all outputs
0.5 kVAC for 1 min. 1 kVAC for 1 min. 0.5 kVAC for 1 min. 1 kVAC for 1 min.
and PE
terminals
10 to 55 Hz, 0.26-mm single amplitude for 2 h each in X, Y, and Z 10 to 55 Hz, 0.26-mm single amplitude for 2 h each in X, Y, and Z
Vibration resistance
Other directions directions
MTBF 135,000 hrs 135,000 hrs
Warranty 1 year 2 years 1 year 2 years
Output indicator Yes (Color: Green) Yes (Color: Green)
Bottom-
mounting 369780 mm 3898129 mm
model
Dimensions
(WHD) DIN Rail-
mounting
4697105 mm 4698154 mm
model
(See note 3.)
Bottom-
mounting 190 g 200 g 280 g
Weight model
(typical) DIN Rail-
mounting 360 g 370 g 450 g
model
Note: 1. Unless otherwise specified, all parameters are measured with a 230-VAC input, at the rated load, and at an ambient temperature of 25C.
2. Ripple and noise are measured at a bandwidth of 20 MHz.
3. Refer to the dimensional diagrams for details on DIN Rail-mounting Models (excluding terminal blocks and DIN Rail products).

4
S8JC-Z

50-/100-W Models
Power ratings 50 W 100 W
Item Series name S8JC-Z S8JC-ZS S8JC-Z S8JC-ZS
Certification --- CE (EN50178) --- CE (EN50178)
Output voltage (VDC) 5V 12 V 24 V 48 V 5V 12 V 24 V 5V 12 V 24 V 48 V 5V 12 V 24 V
Output current 10.0 A 4.2 A 2.1 A 1.1 A 10 A 4.2 A 2.1 A 20 A 8.5 A 4.5 A 2.3 A 20 A 8.5 A 4.5 A
Voltage adjustment
10% to 10% 10% to 10%
Output range (typical)
Ripple (typical) 150 mV 100 mV 200 mV 80 mV 60 mV 50 mV 130 mV 120 mV 100 mV 200 mV 160 mV 140 mV 150 mV
Startup time (typical) 300 ms 240 ms 260 ms 300 ms 300 ms 700 ms 600 ms 250 ms 270 ms 300 ms
Hold time (typical) 50 ms 35 ms 40 ms 30 ms 50 ms 50 ms 55 ms 50 ms
Efficiency (typical) 76% 83% 84% 86% 75% 83% 78% 85% 86% 87% 77% 81% 87%
Voltage 200 to 240 VAC (185 to 264 VAC) 200 to 240 VAC (185 to 264 VAC)
Frequency 50/60 Hz
50/60 Hz (47 to 64 Hz) 50/60 Hz (47 to 64 Hz)
(47 to 63 Hz)
Current (typical) 0.65 A 1.4 A
Input
Leakage current 1 mA max. 1 mA max.
Inrush current (for a
cold start at 25C) 40 A 40 A
(typical)
105% of rated load current, voltage drop, intermittent, automatic 105% of rated load current, voltage drop, intermittent, automatic
Overload protection
reset reset
Additional Overvoltage protection Yes Yes
functions
Parallel operation No No
Series operation No No
Ambient operating
temperature
*10C to 60C *20C to 70C *10C to 60C *20C to 70C
*Refer to the derating curve
in Engineering Data
Between
all inputs
1.5 kVAC for 1 min. 3 kVAC for 1 min. 1.5 kVAC for 1 min. 3 kVAC for 1 min.
and
outputs
Dielectric
Between
strength
all inputs
(detection 1.5 kVAC for 1 min. 2 kVAC for 1 min. 1.5 kVAC for 1 min. 2 kVAC for 1 min.
and PE
current:
terminals
20 mA)
Between
all outputs
0.5 kVAC for 1 min. 1 kVAC for 1 min. 0.5 kVAC for 1 min. 1 kVAC for 1 min.
and PE
terminals
10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z 10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z
Vibration resistance
Other directions directions
MTBF 135,000 hrs 135,000 hrs
Warranty 1 year 2 years 1 year 2 years
Output indicator Yes (Color: Green) Yes (Color: Green)
Bottom- 5098 5098
mounting 3898129 mm 159 3898159 mm 159 3898159 mm
model mm mm
Dimensions
(WHD) DIN Rail-
5298 5298
mounting
4698154 mm 185 4698185 mm 186 4698186 mm
model
mm mm
(See note 3.)
Bottom-
mounting 280 g 430 g 370 g 350 g 370 g 440 g 380 g 370 g
Weight model
(typical) DIN Rail-
mounting 450 g 600 g 540 g 520 g 540 g 620 g 550 g 540 g
model
Note: 1. Unless otherwise specified, all parameters are measured with a 230-VAC input, at the rated load, and at an ambient temperature of 25C.
2. Ripple and noise are measured at a bandwidth of 20 MHz.
3. Refer to the dimensional diagrams for details on DIN Rail-mounting Models (excluding terminal blocks and DIN Rail products).

5
S8JC-Z

150-/350-W Models
Power ratings 150 W 350 W
Item Series name S8JC-Z S8JC-ZS S8JC-Z S8JC-ZS
Certification --- CE (EN50178) --- CE (EN50178)
Output voltage (VDC) 5V 12 V 24 V 48 V 5V 12 V 24 V 5V 12 V 24 V 5V 12 V 24 V
Output current 30 A 12.5 A 6.5 A 3.3 A 30 A 12.5 A 4.5 A 50 A 29 A 14.6 A 60 A 29 A 14.6 A
Voltage adjustment 10% to 10% 10% to 10%
Output range (typical)
Ripple (typical) 140 mV 180 mV 150 mV 300 mV 210 mV 210 mV 200 mV 300 mV 240 mV 200 mV 300 mV 240 mV 200 mV
Startup time (typical) 300 ms 750 ms 250 ms 750 ms 300 ms 700 ms 700 ms 300 ms 700 ms 700 ms 300 ms
Hold time (typical) 50 ms 50 ms 70 ms 60 ms 25 ms
Efficiency (typical) 79% 85% 88% 86% 79% 85% 87% 77% 78% 84% 75% 78% 84%
Voltage 200 to 240 VAC (185 to 264 VAC) 200 to 240 VAC (185 to 264 VAC)
Frequency 50/60 Hz
50/60 Hz (47 to 64 Hz) 40/60 Hz (47 to 64 Hz)
(47 to 63 Hz)
Current (typical) 2.0 A 4.2 A
Input
Leakage current 1 mA max. 1 mA max.
Inrush current (for a
cold start at 25C) 40 A 40 A
(typical)
105% of rated load current, voltage drop, intermittent, automatic 105% of rated load current, voltage drop, intermittent, automatic
Overload protection
reset reset
Additional Overvoltage protection Yes Yes
functions
Parallel operation No No
Series operation No No
Ambient operating
temperature
*10C to 60C *20C to 70C *10C to 60C *20C to 70C
*Refer to the derating curve
in Engineering Data
Between
all inputs
1.5 kVAC for 1 min. 3 kVAC for 1 min. 1.5 kVAC for 1 min. 3 kVAC for 1 min.
and
outputs
Dielectric
Between
strength
all inputs
(detection 1.5 kVAC for 1 min. 2 kVAC for 1 min. 1.5 kVAC for 1 min. 2 kVAC for 1 min.
and PE
current:
terminals
20 mA)
Between
all outputs
0.5 kVAC for 1 min. 1 kVAC for 1 min. 0.5 kVAC for 1 min. 1 kVAC for 1 min.
and PE
terminals
10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z 10 to 55 Hz, 0.26-mm single amplitude for 2h each in X, Y, and Z
Vibration resistance
Other directions directions
MTBF 135,000 hrs 135,000 hrs
Warranty 1 year 2 years 1 year 2 year
Output indicator Yes (Color: Green) Yes (Color: Green)
Bottom- 4398 4398
mounting 199 5098159 mm 199 5098159 mm 50115195 mm
model mm mm
Dimensions
(WHD) DIN Rail-
4698 4698
mounting
225 5298185 mm 226 5298186 mm 52115221 mm
model
mm mm
(See note 3.)
Bottom-
mounting 580 g 530 g 450 g 560 g 530 g 450 g 753 g 766 g 750 g 788 g 800 g 774 g
Weight model
(typical) DIN Rail-
mounting 750 g 700 g 620 g 750 g 700 g 620 g 911 g 924 g 920 g 946 g 958 g 932 g
model
Note: 1. Unless otherwise specified, all parameters are measured with a 230-VAC input, at the rated load, and at an ambient temperature of 25C.
2. Ripple and noise are measured at a bandwidth of 20 MHz.
3. Refer to the dimensional diagrams for details on DIN Rail-mounting Models (excluding terminal blocks and DIN Rail products).

6
S8JC-Z
Block Diagrams

AC (L) +V
Fuse
INPUT Noise DC OUTPUT
filter
AC (N) −V
Inrush current Rectifier Smoothing Rectifier/
protection circuit Smoothing circuit

Drive control
Circuit Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W
5V ● ● ● ●
12 V ● ● ● ● ●
Overcurrent S8JC-Z
detection
Voltage 24 V ● ● ● ● ●
circuit detection
48 V ● ● ●
Overvoltage
5V ●
detection circuit S8JC-ZS 12 V ●
24 V ●

AC (L) +V
Fuse
INPUT Noise DC OUTPUT
filter
AC (N) −V
Inrush current Rectifier Smoothing Rectifier/
protection circuit Smoothing circuit

Drive control
Circuit Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W
5V
12 V
Overcurrent Voltage
S8JC-Z
detection 24 V
circuit detection
48 V ● ●
Overvoltage
5V ● ● ●
detection circuit S8JC-ZS 12 V ● ● ● ●
Photocoupler
24 V ● ● ● ●

AC (L) +V
Fuse
INPUT Noise DC OUTPUT
filter
AC (N) −V
Inrush current Rectifier Smoothing Rectifier/
protection circuit Smoothing circuit

Drive control
Circuit Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W
5V ●
12 V
Overcurrent S8JC-Z
detection
Voltage 24 V ●
circuit detection
48 V
Overvoltage
5V ●
detection circuit S8JC-ZS 12 V
Photocoupler
24 V ●

AC (L)
Fuse
INPUT Noise
filter
AC (N)
Inrush current Rectifier Smoothing
protection circuit

+V

DC OUTPUT

−V
Rectifier/
Drive circuit Smoothing circuit

Series Voltage 15 W 35 W 50 W 100 W 150 W 350 W


Overcurrent
Control Circuit detection 5V ●
circuit
12 V ●
S8JC-Z
Overheat Voltage
24 V
protection detection 48 V
5V ●
Overvoltage
detection circuit S8JC-ZS 12 V ●
Photocoupler 24 V

7
S8JC-Z
Engineering Data
Derating Curves for S8JC-Z Derating Curves for S8JC-ZS
120 120
Load rate (%)

Load rate (%)


100 100
A A
80 80

60 60

40 40

20 20

0 0
-20 -10 0 10 20 30 40 50 60 70 -20 -10 0 10 20 30 40 50 60 70
Ambient Temperature (°C) Ambient Temperature (°C)

Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the
area shown by shading “A” in the above graph).
2. If there is a derating problem, use forced air-cooling.

Terminal Arrangement
15-/35-/50-W Models 100-/150-/350(24 V)-W Models 350(5 V, 12 V)-W Models

AC(L) AC(L) AC(L)


AC(N) AC(N) AC(N)

−V
−V −V
−V
+V −V −V
+V +V
+V +V
+V

Note: The S8JC-Z05024C is shown above. Note: 1. The S8JC-Z10024C is shown above. Note: The S8JC-Z35005C is shown above.
2. The rated current for output terminals
is 25 A per terminal. Be sure to use
multiple terminals simultaneously for
current that exceeds the terminal
rating. When applying a current of 25 A
or more, use at east two terminals each
for the positive and negative wires.

Terminal Cover Fitting


S8JC-ZS@@@@@C Models S8JC-ZS@@@@@C Models
Removing Fitting

a a

b b

(1) (2) (3) (4)


In (1) case, please push scratched parts (a, b) on the cover following the arrow “ ”
In (2) case, please remove the cover following the arrow “ ”
In (3) case, please remove the cover following the arrow “ ”
In (4) case, please push scratched parts (a, b) on the cover following the arrow “ ”

8
S8JC-Z
Dimensions (Unit: mm)

Bottom-mounting Models
S8JC-Z015@@C (15 W) S8JC-ZS015@@C-AC2 (15 W)

3.5

97±1
9.5

65±0.5
8
3.5 dia.

45.5
5.5
36±1 20.5 35±0.5
4.25
70.5±0.5
79.5±1
4.5
4 dia.

4
30.5
17.5

24
18 54±0.5
Two, M3
(Depth 2 mm max.) 75±1

Panel mounting holes dimensions


Surface screw mounting

Two, M3

59.5±0.5
Side
Mounting

70.5±0.5

6.5±0.5
Bottom Two, M3
Mounting
70.5±0.5

Note: The screws must not protrude more than 2 mm inside the Power Supply when screw holes provided
on the chassis are used. If the dimensions are not correct, the Power Supply may be damaged.

S8JC-Z035@@C (35 W) S8JC-ZS035@@C-AC2 (35 W)


S8JC-Z050@@C (50 W) S8JC-ZS050@@C-AC2 (50 W) 129±1
98.3±1
33±0.5
9.5
8

4 dia.
34
5.5

38±1 4.5 78

32 77±0.5
4 dia. 6.5
10.5 18±0.5

15.5 13
29
19.5

Three, M3
(Depth 2 mm max.)

Panel mounting holes dimensions


Surface screw mounting

Two, M3
85.5±0.5

Side
Mounting

122.5±0.5
13±0.5

Three, M3
Bottom
Mounting
120±0.5

9
S8JC-Z

S8JC-Z10005C (100 W) S8JC-ZS10005C-AC2 (100 W) Seven, M3 screws Four, M3 screws

80±0.5
98
9.5
8
4 dia.

8.7
6
50±1 4.5
22 120±0.5

159±1

4 dia. 7 149.5±0.5

26±0.5
43.5

13
29

17.5
20
Three, M3
(Depth 2 mm max.) 22 125±0.5

Panel mounting holes dimensions


Surface screw mounting

Two, M3

84±0.5
Side
Mounting

152±0.5

26±0.5
Bottom
Three, M3
Mounting

149.5±0.5

S8JC-Z10012C (100 W) S8JC-ZS10012C-AC2 (100 W)


S8JC-Z10024C (100 W) S8JC-ZS10024C-AC2 (100 W)
S8JC-Z10048C (100 W)
80±0.5
97.6±1
9.5
8

4 dia.
8.7
6

38±1 4.5
22 120±0.5
159±1
4 dia. 7 149.5±0.5
16.5 15±0.5
13±0.5
31.5
22

13

22 125±0.5
Three, M3
(Depth 2 mm max.)

Panel mounting holes dimensions


Surface screw mounting

Two, M3
84±0.5

Side
Mounting

152±0.5

149.5±0.5
15±0.5

Bottom
Mounting
Three, M3

10
S8JC-Z

S8JC-Z15005C (150 W) S8JC-ZS15005C-AC2 (150 W) 62 120±0.5

3.5

85.5±0.5
80±0.5

98
9.5
8
8.5
5
43 4.5 3.5 dia. 192.5±0.5
199

6.5 190±0.5

3.5
3.5 dia.

15 18±0.5
33.5
33.5
24.5
22 157±0.5
Three, M3 (Depth 2 mm max.)

Panel mounting holes dimensions


Surface screw mounting

85.5±0.5
Side
Mounting

Two, M3

192.5±0.5

Bottom Two, M3
Mounting
190±0.5

S8JC-Z15012C (150 W) S8JC-ZS15012C-AC2 (150 W) Seven, M3 screws Four, M3 screws


S8JC-Z15024C (150 W) S8JC-ZS15024C-AC2 (150 W)
S8JC-Z15048C (150 W)
80±0.5
98
9.5
8

4 dia.
8.7
6

50±1 4.5
22 120±0.5

159±1

4 dia. 7 149.5±0.5
26±0.5
43.5

13
29

17.5
20

Three, M3
(Depth 2 mm max.) 22 125±0.5

Panel mounting holes dimensions


Surface screw mounting

Two, M3
84±0.5

Side
Mounting

152±0.5
26±0.5

Bottom
Three, M3
Mounting

149.5±0.5

11
S8JC-Z

S8JC-Z35005C (350 W) S8JC-ZS35005C-AC2 (350 W)


S8JC-Z35012C (350 W) S8JC-ZS35012C-AC2 (350 W)

Panel mounting holes dimensions


(3) 193.6 (3) Surface screw mounting
Four, M3

145±0.5
Four, M3
80±0.5
115

Side
Mounting

80±0.5
9.5
8

18.2

50 (3) 32.8 145±0.5

Four, M4
30 150±0.5 (Depth 2 mm max.)
25±0.5

150±0.5
Four, M4
Bottom
Mounting

25±0.5
13

S8JC-Z35024C (350 W) S8JC-ZS35024C-AC2 (350 W)

Panel mounting holes dimensions


(3) Surface screw mounting

145±0.5
Four, M3
80±0.5

115

Side
9.5

80±0.5

Mounting
8
17.2

50±1 (3) 32.8 145±0.5


194.8

Four, M4
30 150±0.5 (Depth 2 mm max.)
25±0.5

150±0.5
Four, M4
Bottom
Mounting
25±0.5
13

12
S8JC-Z

DIN Rail-mounting Models


S8JC-Z015@@CD (15 W) S8JC-ZS01524CD-AC2 (15 W)

97
9.5
7.8
(10) 79.5

5.5
(3) 46 (15.6)
9.5 mm max.

S8JC-Z035@@CD (35 W) S8JC-ZS035@@CD-AC2 (35 W)


S8JC-Z050@@CD (50 W) S8JC-ZS050@@CD-AC2 (50 W)

98.3
9.5
7.8

5
(3) 46 (10) 129 15
9.5 mm max.

S8JC-Z10005CD (100 W) S8JC-ZS10005CD-AC2 (100

97.5
9.5
7.8

(3)

5
51.5 (10) 159 (16)
9.5 mm max.

S8JC-Z10012CD (100 W) S8JC-ZS10012CD-AC2 (100 W)


S8JC-Z10024CD (100 W) S8JC-ZS10024CD-AC2 (100 W)
S8JC-Z10048CD (100 W)
97.6
9.5
7.8

(3) 46 (10) 159 (16.1)


5

9.5 mm max.

13
S8JC-Z

S8JC-Z15005CD (150 W) S8JC-ZS15005CD-AC2 (150W)

98
9.5
7.8
(3) 46 (10) 199 (16)

(5)
9.5mm max.

S8JC-Z15012CD (150 W) S8JC-ZS15012CD-AC2 (150 W)


S8JC-Z15024CD (150 W) S8JC-ZS15024CD-AC2 (150 W)
S8JC-Z15048CD (150 W)

97.5
9.5
7.8
(3)

5
51.5 (10) 159 (16)
9.5 mm max.

S8JC-Z35005CD (350 W) S8JC-ZS35005CD-AC2 (350 W)


S8JC-Z35012CD (350 W) S8JC-ZS35012CD-AC2 (350 W)

115
9.5
7.5
6.8

(3) 51.5 (3) (12) 193.6 (17.2)

S8JC-Z35024CD (350 W) S8JC-ZS35024CD-AC2 (350 W)


115
9.5
7.8

(3) (3) (10) (16)


194.8
5

51.5
9 mm max.

14
S8JC-Z
Safety Precautions
Refer to Safety Precautions for All Power Supplies.
Precautions for Safe Use
 Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF.
 Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied.
 Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Product.
 Connect the ground completely. Electric shock or malfunction may occur if the ground is not connected completely.
 The service life of the fan is approximately 35,000 hours (at 25C). The service life varies, however, depending on the ambient temperature or
other surrounding environmental conditions such as dust. As a guide, replace the product within two years if it is used at an ambient temperature
of 40C. (For 350-W Models only.)
 The screws must not protrude more than 2 mm inside the Power Supply when screw holes provided on the chassis are used.
 Avoid places where the product is subjected to penetration of liquid, foreign substance, or corrosive gas (in particular, sulfide gas or ammonia
gas).
 The rated current for output terminals is 25 A per terminal. Be sure to use multiple terminals simultaneously for current that exceeds the terminal
rating. When applying a current of 25 A or more, use at east two terminals each for the positive and negative wires.

15
Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any questions
or comments.

Warranty and Limitations of Liability


WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period
if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT,
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS
UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY
RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to
fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm
actual specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is
subject to the OMRON Warranty and Limitations of Liability.

OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. Authorized Distributor:
No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower,
Alexandra Technopark, Singapore 119967 200 Yin Cheng Zhong Road,
Tel: (65) 6835-3011/Fax: (65) 6835-2711 PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

© OMRON Corporation 2009 All Rights Reserved.


In the interest of product improvement,
specifications are subject to change without notice.
CSM_1_8_0712 Printed in Japan
OMRON Industrial Automation Global: www.ia.omron.com Cat. No. T044-E1-07 0712

You might also like