ENVPEP121004EN_V5 - Product Environmental Profile - Motor circuit breaker,TeSys Deca,Push-button
Product Environmental Profile
Motor circuit breaker,TeSys Deca,Push-button
TeSys Deca Motor circuit breaker
ENVPEP121004EN_V5 # Internal 03/2024
ENVPEP121004EN_V5 - Product Environmental Profile - Motor circuit breaker,TeSys Deca,Push-button
General information
Reference product Motor circuit breaker,TeSys Deca,Push-button - GV2ME08
The main purpose of the product is to protect three-phase motors, the cables, the people, against short circuits and
Description of the product
overloads.
The range product includes :rated current:0.16A-32A,TeSys Deca Motor circuit breaker, control type: Push-button/Toggle
,the representative product used for analysis is GV2ME 3P 4A (product number: GV2ME08)
Description of the range
The environmental impacts of this reference product are representative of the impacts of the other products of the range
which are developed with a similar technology.
Protect during 20 years the installation against overloads and short-circuits in circuit with assigned voltage 690V AC and
rated current 4A. This protection is ensured in accordance with the following parameters:
Functional unit
- Number of poles 3p
- Rated breaking capacity 3KA
Constituent materials
Reference product mass 276.5 g including the product, its packaging and additional elements and accessories
PPS Polyphenylene sulfure - 1.1%
PC Polycarbonate - 0.1%
PBT Polybutylene Terephtalate - 8.7%
Steel - 38.7%
PA Polyamide - 35.8%
Ferrous alloys - 4.6%
Various - <0.1%
Copper - 4.1%
Stainless steel - 0.5%
Paper - 0.4% Brass - <0.1%
Cardboard - 6.1%
Plastics 45.70%
Metals 47.80%
Others 6.50%
Substance assessment
Details of ROHS and REACH substances information are available on the Schneider-Electric Green Premium website
https://www.se.com/ww/en/work/support/green-premium/
ENVPEP121004EN_V5 # Internal 03/2024
ENVPEP121004EN_V5 - Product Environmental Profile - Motor circuit breaker,TeSys Deca,Push-button
Additional environmental information
Recyclability rate has been calculated based on REEECY'LAB tool developed by Ecosystem, for
components/materials not covered by the tool, data from the “ECO’DEEE recyclability and
End Of Life Recyclability potential: 63%
recoverability calculation method” was taken. If no data was found a conservative assumption was used
(0% recyclability).
Environmental impacts
Reference service life time 20 years
Product category Circuit-breakers
Installation elements Ref GV2ME08 does not require any installation operations.
Load rate: 50% of In
Use scenario
Use time rate: 30% of RLT
Technological
The main purpose of the product is to protect three-phase motors, the cables, the people, against short circuits and overloads.
representativeness
Geographical
Europe
representativeness
[A1 - A3] [A5] [B6] [C1 - C4]
Energy model used Electricity Mix; Production mix; Low voltage; Electricity Mix; Production Electricity Mix; Production Electricity Mix; Production
FR mix; Low voltage; UE-27 mix; Low voltage; UE-27 mix; Low voltage; UE-27
Detailed results, including all the optional indicators mentioned in PCRed4, and the split of the Use Phase (B1 to B7), are available in the LCA report
and on demand in a digital format - Country Customer Care Center - http://www.schneider-electric.com/contact
Mandatory Indicators Motor circuit breaker,TeSys Deca,Push-button - GV2ME08
Manufacturing Distribution Installation Use End of Life Benefits
Impact indicators Unit Total
[A1 - A3] [A4] [A5] [B1 - B7] [C1 - C4] [D]
Contribution to climate change kg CO2 eq 4.26E+01 1.46E+00 7.97E-02 3.00E-02 4.04E+01 6.39E-01 -7.58E+00
Contribution to climate change-fossil kg CO2 eq 4.25E+01 1.45E+00 7.97E-02 2.87E-02 4.03E+01 6.36E-01 -7.56E+00
Contribution to climate change-biogenic kg CO2 eq 6.80E-02 1.05E-02 0* 1.33E-03 5.39E-02 2.28E-03 -2.62E-02
Contribution to climate change-land use and land use change kg CO2 eq 3.72E-08 0* 0* 0* 0* 3.72E-08 0.00E+00
kg CFC-11
Contribution to ozone depletion 4.40E-07 1.90E-07 7.03E-08 1.99E-09 1.73E-07 4.80E-09 -1.15E-06
eq
Contribution to acidification mol H+ eq 2.41E-01 8.21E-03 3.46E-04 1.19E-04 2.30E-01 1.65E-03 -4.90E-02
kg (PO4)³¯
Contribution to eutrophication, freshwater 2.13E-04 2.30E-05 0* 2.17E-07 1.11E-04 7.93E-05 -1.25E-05
eq
Contribution to eutrophication marine kg N eq 2.78E-02 1.07E-03 1.59E-04 3.16E-05 2.62E-02 3.24E-04 -4.43E-03
Contribution to eutrophication, terrestrial mol N eq 4.11E-01 1.14E-02 1.72E-03 2.38E-04 3.93E-01 3.72E-03 -5.14E-02
kg
Contribution to photochemical ozone formation - human
COVNM 9.00E-02 4.12E-03 5.66E-04 6.36E-05 8.41E-02 1.16E-03 -1.82E-02
health
eq
Contribution to resource use, minerals and metals kg Sb eq 9.62E-03 9.62E-03 0* 0* 2.93E-06 2.25E-06 -2.29E-03
Contribution to resource use, fossils MJ 1.08E+03 2.88E+01 9.68E-01 3.13E-01 1.03E+03 2.50E+01 -1.70E+02
Contribution to water use m3 eq 2.01E+00 8.75E-02 4.04E-03 1.28E-02 1.43E+00 4.79E-01 -3.35E+00
ENVPEP121004EN_V5 # Internal 03/2024
ENVPEP121004EN_V5 - Product Environmental Profile - Motor circuit breaker,TeSys Deca,Push-button
Additional indicators for the French regulation are available as well
Inventory flows Indicators Motor circuit breaker,TeSys Deca,Push-button - GV2ME08
Manufact. Distribution Installation Use End of Life Benefits
Inventory flows Unit Total
[A1 - A3] [A4] [A5] [B1 - B7] [C1 - C4] [D]
Contribution to use of renewable primary energy excluding
MJ 1.98E+02 1.58E-01 0* 2.24E-02 1.98E+02 5.74E-02 -1.32E+00
renewable primary energy used as raw material
Contribution to use of renewable primary energy resources
MJ 3.45E-01 3.45E-01 0* 0* 0* 0* -2.97E-01
used as raw material
Contribution to total use of renewable primary energy
MJ 1.98E+02 5.04E-01 0* 2.24E-02 1.98E+02 5.74E-02 -1.62E+00
resources
Contribution to use of non renewable primary energy
excluding non renewable primary energy used as raw MJ 1.08E+03 2.61E+01 9.68E-01 3.13E-01 1.03E+03 2.50E+01 -1.69E+02
material
Contribution to use of non renewable primary energy
MJ 2.71E+00 2.71E+00 0* 0* 0* 0* -1.49E+00
resources used as raw material
Contribution to total use of non-renewable primary energy
MJ 1.08E+03 2.88E+01 9.68E-01 3.13E-01 1.03E+03 2.50E+01 -1.70E+02
resources
Contribution to use of secondary material kg 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
Contribution to use of renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
Contribution to use of non renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
Contribution to net use of freshwater m³ 5.79E-02 3.08E-03 9.41E-05 2.99E-04 3.33E-02 2.12E-02 -7.81E-02
Contribution to hazardous waste disposed kg 1.38E+01 1.28E+01 0* 0* 7.55E-01 2.83E-01 -1.81E+02
Contribution to non hazardous waste disposed kg 6.93E+00 9.54E-01 0* 9.77E-02 5.81E+00 6.85E-02 -6.28E+00
Contribution to radioactive waste disposed kg 2.43E-03 1.18E-03 1.58E-05 1.31E-05 1.22E-03 3.91E-06 -2.67E-03
Contribution to components for reuse kg 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
Contribution to materials for recycling kg 1.43E-01 0* 0* 1.65E-02 0* 1.27E-01 0.00E+00
Contribution to materials for energy recovery kg 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
Contribution to exported energy MJ 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
Contribution to biogenic carbon content of the product kg de C 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
Contribution to biogenic carbon content of the associated
kg de C 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
packaging
* represents less than 0.01% of the total life cycle of the reference flow
Life cycle assessment performed with EIME version v5.9.4, database version 2022-01 in compliance with ISO14044.
Detailed results, including all the optional indicators mentioned in PCRed4, and the split of the Use Phase (B1 to B7), are available in the LCA report
and on demand in a digital format - Country Customer Care Center - http://www.schneider-electric.com/contact
According to this environmental analysis, proportionality rules may be used to evaluate the impacts of other products of this range, ratios to apply can be provided
upon request
ENVPEP121004EN_V5 # Internal 03/2024
ENVPEP121004EN_V5 - Product Environmental Profile - Motor circuit breaker,TeSys Deca,Push-button
Please note that the values given above are only valid within the context specified and cannot be used directly to draw up the environmental assessment of an
installation.
Registration number : ENVPEP121004EN_V5 Drafting rules PEP-PCR-ed4-2021 09 06
Verifier accreditation N° Supplemented by PSR-0005-ed2-2016 03 29
Information and
Date of issue 03/2024 www.pep-ecopassport.org
reference documents
Validity period 5 years
Independent verification of the declaration and data, in compliance with ISO 14021 : 2016
Internal X External
The PCR review was conducted by a panel of experts chaired by Julie ORGELET (Ddemain)
PEP are compliant with XP C08-100-1 :2016 or EN 50693:2019
The elements of the present PEP cannot be compared with elements from another program.
Document in compliance with ISO 14021 : 2016 « Environmental labels and declarations. Type II environmental declarations »
Schneider Electric Industries SAS
Country Customer Care Center
http://www.schneider-electric.com/contact
35, rue Joseph Monier
CS 30323
F- 92500 Rueil Malmaison Cedex
RCS Nanterre 954 503 439
Capital social 896 313 776 €
www.se.com Published by Schneider Electric
ENVPEP121004EN_V5 ©2023 - Schneider Electric – All rights reserved 03/2024
ENVPEP121004EN_V5 # Internal 03/2024