text 3
text 3
1. Sign off all open shifts and run EOD (Highly recommended) (No more signon on
MPos and trading on other Point Of Sales can commence except EFT).
2. Once namos EOD is done, stop namos on MPos.
3. Increment MPos last octet by 1 i.e. last octet + 1.
4. Create a folder on D:\ as "ZAPOSXXX01_YYYYMMDD" where backup files will
be copied to
Verification of shifts
1. navigateN to c:\SNI \Namos\CMOS
2. Scroll down to the latest TAP.THP file checking date on the file.
3. Open the file with notepad and scroll all the way down on the file.
4. Look for the following abbreviations for the latest shift number. (Tip
Number is usually double on the line)

6. Go to FSM and send latest/current fuel prices from MWS so that they are
available/copied on to namos DB rather than fdc (Fixes fuel prices on namos EOD
report i.e. DSP & timestamp on the repot)
7. Start ISISIntfaceLink services (services.msc from command line).
8. Verify TIC files are being generated from the root (C:\Radiant\Export\
Xchg).
9. Remove, Run latest EFTRepair
10. Build Namos Configuration. Select “Load current” Acknowledge the “Load
current configuration” pop-up. Under the “Country Options” tab in the BOS/POS
configuration Window, enter the BOS computer name in the “FTP-server” block, in the
“Username” block enter NM_Admin AND in the “Export-path” block enter localhost

11. When done with the above click “Save current” and acknowledge the
“Change current configuration “ pop-up by clicking on “YES” Wait for Configuration
to replicate to all online POS systems and close. Click on OK and select YES.
12. On a 64bit site edit the DOMS section of the HOST and LMHOST, with the
relevant IP address for the DOMS PSS5000 controller. Replicate this to all the WDM
POS systems.
13. Start Namos WDM Background while in Admin mode. Navigate to MWS User
rights and Change “Final EOD” for profile 1 to 7 from “All allowed” to “Disabled”.
Remember to save the changes after every profile change.

Go to registry setting and change the following:
Tips: should Local Accounts not print when statement is created, ensure Brother
Printer is online (MPos)
If MPos time zone default to 2008, then only Restore a Backup before the issue
emerged but don’t restore
TAL*.*,TAP*.*, TAV*.* (CMOS contents)
Namos Reports
If you run “Backup & Restore” process but for some reasons, you accidentally close
MWS, ran “initload -refresh” then start POS WDM background, logon to MWS again
and restore.
******************************************************************************
**************HDD Replacement/Backup & Restore*************
*******************************************************************************
Backup the following if HDD is accessible:
1. Stop NAMOS
2. Logon as administrator
3. Create a folder on D:\ as ZAPOS12001_20161202 (site specific)
4. Copy the following from relevant directory to the previously created
folder:
###########################################################
Point Of Sales stuck on getting pump counters :Solution - Perform FDC Golive with
master logon (32565) (Master & Slave WDM)
Credit/Bank card option missing on auxiliary Pos : Ensure on MWS under POS system,
Credit/Bank card option is selected.
Pumps come-up with unknown attendants: Solution - FCTagAttendantTimeout=2 &
FCTagTimeout=5; HKEY_LOCAL_MACHINE\SOFTWARE\Wincor Nixdorf\NAMOS (MPos) (WDM Master
& Slave)
###########################################################
Restore from command prompt
namosctl restore
NB: it only restores TAB files
###########################################################
###########################################################
Internet Solution Equipment
###########################################################
ATG
Module Cable2DOMS DB9@ATG DB25@ATG
TX RED Pin 2 Pin 3
RX BLUE Pin 3 Pin 2
GND GREEN Pin 5 Pin 7
PUMPS
DSB492 (prowalco)
Red Blue Yellow Green
Positive (+) Negative (-) Positive (+) Negative (-)
PROWALCO ICON
DSB347
DSB520 (Tokheim)
WWC TTD TTC DCC
None Red (+) Blue (-ve) Green (GND)
(DSB453 )Connecting the VIT Cable to the DOMS Module (Connect same for WGT and
Display)
The new cable going to the VIT Interface must be connected to the DOMS Module-
DSB453
Cable
###########################################################
###########################################################
Total IP calculations
*****************
****32 Range****
*****************
MPos 10.114.xxx.aaa
BOS aaa = MPos last octet + 5
Brother Printer =MPos last octet +3
DOMS = MPos last octet + 7
Default Gateway = MPos last octet + 11
Network = MPos last octet - 19
Kitchen Scale = MPos last octet - 16
Kitchen Printer = MPos last octet - 17
AP1 = MPos last octet - 10
*******************************
***************
***64 Range***
***************
MPos 10.114.xxx.aaa
BOS aaa = MPos last octet + 7
Brother Printer MPos last octet + 5
DOMS = MPos last octet + 10
Default Gateway = MPos last octet + 15
Network = MPos last octet - 47
Kitchen Scale = MPos last octet - 38
Kitchen Printer = MPos last octet - 39
AP1 = MPos last octet - 32
###########################################################
FDCs
SYS_PROCS
S - case sensitive
Pos1 below tah_bos (fdccntl)
Below namoscron (tagserv)
2
below na_upd (fdccntl)
Below tah_pos (tagserv)
###########################################################
When doing EOD and shift 59 does not close/drop even though cashiers signed off
(LPOS).
1. Log in with Lanceur (MPos).
2. Open Dos command Prompt
3. Type in “sqledit” and press enter
4. Press on connect
5. Select * from costa where shiftno=345(shift no of Terminal 59)
Refer to step 10 and thereafter proceed with step 6.

###########################################################
###########################################################
Back Office Machine
Subst f: d:\temp
Subst f: /d
Windows 7 Total SA
AL0458227 or administrator
AL0511024 or administrator
Chiefs2015 or VnVpCnPh287
Memberid =WUpgrade
Password=Win7Deploy
Domain - echange.ms.corp.local
Username - T_ZA_DpltOperator
Password - TotENG2014
OR
Username - administrator
Password - Ech@nge2013
HHT
Username = sa
Password = BhhTTot@1
Site Config = za-bhht.isis.total.com
OR
Username = 1
Password = 1
OR
Username = admin
Password = 12345
Loading of BOS
1. Format HDD (Diskpart)
2. Load image (F12 for one time boot)
3. Plug network cable & join domain using master.
4. Change password from (manage) users to VnVpCnPh287
If account is disabled, logon with “Master” then right click on "Computer" go to
manage, Local users and groups, expand it then users. Right click on
"Administrator" then properties. Uncheck “disable”.
5. Logoff master & logon with (administrator and VnVpCnPh287)
6. Unplug network cable to install software. Right click on “cmd” & run as
administrator. Then type F: \ PostInstall \ Installation.HTA " and confirm (15Min)
7. Reconnect LAN cable. Go to f:\Postinstall\Echange_installer_v1.0.bat
right click & run as administrator. Will install SQLCE, BatchHHT Software
8. Copy back site data
9. Launch internet explorer, go to Internet Options, Select the Security
Tab, Click on “local intranet”, sites, advanced and add the following URL
http://www.total.com; za.isis.total .com, Uncheck “Require server verification” and
Click On the Add button.
10. Uncheck radio button under “Require server verification (https:) for
all sites in this zone” then close, ok
11. Select Trusted Sites & ensure “Download Signed ActiveX Control” is
enabled. Restart IE , add the following URL if they do not appear;
http://www.total.com; za.isis.total .com, Uncheck “Require server verification” and
Click On the Add button.
12. and set home page as default(za.isis.total .com) or if prompted to
restart, you must soft restart pc. VERY IMPORTANT
13. Member ID - WUpgrade
Password - Win7Deploy
6. After entering the password, click « continue » Enter the S-Plant code
« Org Unit »
7. Do not select the Site, but the one with site missing.
8. Select the BU, then choose the Role “Win7Deploy”
9. Type ‘BUS’, a drop down Menu will appear.
10. Select “Business Unit Setup”
11. Click on the Site Code e.g: S007-101093
12. Related Links is situated on the top right of the screen. Click on
Related Links.
13. Select 3rd Party POS Site Link
14. Now select “Link Site”
15. Click on “OK” to link the site.
16. Ensure that the Site Configuration are all successful.
17. Click on “OK”
18. On the top search box in the middle, enter " App/Dow”. Select “Approve
Download Log”
19. Select RSL Configuration Download, check the Business Unit Code click
on “Download”
20. Repeat the ‘Approve Download ‘ step, Select “ Full Download” check the
Business Unit Code click on “Download”
21. On the top search box, in the middle, enter “Dow”, Select “ View
Download Log”
22. In the Export log, « Awaiting Site Connection », will appear. RSL
Configuration Download and Full Download » status must change to Green with
“Success – Site Acknowledged”.
NB : To speed up the process, Click on the Blue Cube icon on the task bar to
initiate the immediate connection to the Enterprise Server
28. Export is complete once you get the Green Lights
Changing HDD
>Backup the following
1. C:\Program Files\BlueCube\POSLink\Transfer\Tic\*.*
2. C:\Program Files\BlueCube\POSLink\namosdata\*.*
3. C:\Program Files\BlueCube\POSLink\bin\ExchangeRates.xml
4. C:\Program Files\BlueCube\POSLink\bin \*-summ.xml
5. C:\Program Files\BlueCube\POSLink\bin \Namoslinksettings.xml
Email setup
1. Mail.office365.com
2. Right click on the link & copy it
3. Tap on blank space & right clink, create shortcut.
4. Right click on shortcut & paste the link.
5. Chose shortcut icon. Done!!!!
########
# TSA #
########
ZAPE000XXX01
ZASXXX01 RSA
######################
# NBLS Countries #
######################
ZAPER00XXX01
NALXXX01 Namibia
BOLXXX01 Botswana
LSLXXX01 Lesotho
SZLXXX01 Swaziland
############################################create a folder "Transfer" on MPos c
root (c:/transfer), add "everyone" share & give full permissions. CTransfer.T
EveryWAN
###########################################################
###########################################################