Basinc Filtreleri
Basinc Filtreleri
D 042 · D 062
· In-line mounting
· Operating pressure up to 100 bar
· Nominal flow rate up to 70 l/min
30.10-2e
30.30-2d
Description
Characteristics
D1 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0 = casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
D2 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0 = casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
Efficiency [%]
x ss t
r. D y -pa en
o . d i a g
i t y o f b e lem
ee en ee c re r tor
pa lte
w p s /curv ess s g ca A/B e ssu tfi ica
o r o
l fl re d m D finen oldin io n p r e n ind
No
. na ect ng l em o. g
ark
s
t mi ressu iagra ilter t-h nn cki ymbo eplac art N igh
t
ggin m
Par N o P d F D i r C o C ra S R P We Clo Re
l/min g bar kg
1 2 3 4 5 6 7 8 9 10 11 12
D 042-153 9 D1/1 5 E-X 3,8 G½ 3,5 4 V3.0510-03 0,8 optional -
D 042-156 15 D1/2 12 E-X 6,1 G½ 3,5 4 V3.0510-06 0,8 optional -
D 042-158 30 D1/3 16 E-X 6,6 G½ 3,5 4 V3.0510-08 0,8 optional -
Optical or electrical indicators are available to monitor the clogging condition of the element. If the indicator should be already mounted onto the filter
head use the abbreviation "M" behind the part number of the indicator. The printed order acknowledgements show both items separately.
Order example: The filter D 042-156 has to be supplied with optical clogging indicator - response pressure 2,0 bar
Clogging indicator
Remarks:
• The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
• The filters listed in this chart are standard filters. Other designs available on request.
Measurements
Type A/B C D E F G H I K L M N O P Q R S T U V W
ø/depth
D 042 G½ 39 148 27 45,5 80 58,5 55 27 35 M6/8 44 36 19 15 70 81 55 23 30 35,5
D 062 G½, G¾ 39 244 27 45,5 80 58,5 55 27 35 M6/8 44 36 19 15 70 81 55 23 30 35,5
Symbols
1 2 3 4 5 6 7
P P
P P
Spare Parts
Quality Assurance
Quality management according to DIN EN ISO 9001 ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 3968 Evaluation of pressure drop versus flow characteristics
To ensure constant quality in production and operation, ISO 16889 Multi-Pass-Test (evaluation of filter fineness and
ARGO-HYTOS filter elements undergo strict controls and tests dirt-holding capacity)
according to the following DIN and ISO standards:
Before release into the series production the filter casing is tested for
DIN ISO 2941 Verification of collapse/burst resistance fatigue strength in our pressure pulse test rig. Various quality controls
DIN ISO 2943 Verification of material compatibility with fluids during the production process guarantee the leakfree function and solidity
DIN ISO 3724 Verification of flow fatigue characteristics of our filters.
Our engineers will be glad to advice you in questions concerning filter application, selection as well as the cleanliness class of the filtered medium attainable
under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.
30.30-2e
30.30-2d
Description
Characteristics
D1 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0 = casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
D2 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0 = casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
D3 Pressure drop as a function of the flow volume Pressure drop as a function of the kinematic viscosity
at ν = 35 mm2/s (0 = casing empty) at nominal flow
∆p [bar]
∆p [bar]
Q [l/min] ν [mm2/s]
Efficiency [%]
ss nt
r. Dx y-pa me
iag fb le
see e no
. d a city re
o
lte
re tor
w drop /curv see cap /B ssu tfi ica
o s s g A r e e n nd
o. l fl ure m D ne
ne ldin ctio
n
ng
p em . gi s
tN na
mi Press iagra rfi t -ho ne cki ymbo
l
p lac rt No igh
t ggin mark
n Clo
Par N o d Fil t e D i r C o C ra S e
R Pa We Re
l/min g bar kg
1 2 3 4 5 6 7 8 9 10 11 12
D 162-253 40 D1/1 5 E-X 18 G1¼ 3,5 4 V3.0817-03 3,2 optional -
D 162-256 65 D1/2 12 E-X 28 G1¼ 3,5 4 V3.0817-06 3,2 optional -
D 162-258 105 D1/3 16 E-X 30 G1¼ 3,5 4 V3.0817-08 3,2 optional -
Optical or electrical indicators are available to monitor the clogging condition of the element. If the indicator should be already mounted onto the filter
head use the abbreviation "M" behind the part number of the indicator. The printed order acknowledgements show both items separately.
Order example: The Filter D 232-256 has to be supplied with optical clogging indicator - response pressure 2,0 bar.
Besides these mounted clogging indicators we also offer - with a certain order quantity - clogging indicators integrated in the filter head
(as listed under "dimensions").
Order examples: D 232-256 ED (electrical differential pressure indicator)
D 232-256 OD (optical differential pressure indicator)
the switching pressure matches the
cracking pressure of the by-pass valve }
Remarks:
• The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
• The filters listed in this chart are standard filters. Other designs available on request.
* Paper media supported with metal gauze
Dimensions
Version ED
with integrated electrical
clogging indicator
Minimum distance
from ferromagnetic
parts: 7 mm
Terminal
connection
Measurements
Type A/B C D E F G H I K L M N O P Q R S T U V W X
ø/depth ED OD
D 162 G1¼ 61 232 38 62 140 95 80 32 80 M12/18 116 SW60 34 17 115 34 66 66 44 30 49 30
D 232 G1¼, G1½ 61 296 38 62 140 95 80 32 80 M12/18 116 SW60 34 17 115 34 66 66 44 30 49 30
D 332 G1¼, G1½ 61 396 38 62 140 95 80 32 80 M12/18 116 SW60 34 17 115 34 66 66 44 30 49 30
Symbols
1 2 3 4 5 6 7
P P
P P
Spare Parts
Quality Assurance
Quality management according to DIN EN ISO 9001 ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 3968 Evaluation of pressure drop versus flow characteristics
To ensure constant quality in production and operation, ISO 16889 Multi-Pass-Test (evaluation of filter fineness and
ARGO-HYTOS filter elements undergo strict controls and tests dirt-holding capacity)
according to the following DIN and ISO standards:
Before release into the series production the filter casing is tested for
DIN ISO 2941 Verification of collapse/burst resistance fatigue strength in our pressure pulse test rig. Various quality controls
DIN ISO 2943 Verification of material compatibility with fluids during the production process guarantee the leakfree function and solidity
DIN ISO 3724 Verification of flow fatigue characteristics of our filters.
Our engineers will be glad to advice you in questions concerning filter application, selection as well as the cleanliness class of the filtered medium attainable
under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.