RESUME
SYED ABRAR UL HAQ
abrar.bilalelectrical@gmail.com
Contact Number : +91-9493254107 (India) / +96566072199 (Kuwait)
APPLICATION FOR THE POST OF ELECTRICAL SENIOR
TECHNICIAN/ELECTRICAL TECHNICIAN
OBJECTIVE
Position as an Electrical Senior Technician (OR )related position which offers key participation, team oriented tasks,
immediate challenges, and career opportunity.
APPROXIMATELY 13 YEAR OF EXPERIENCE IN THE FIELD OF MAINTENANCE in OIL &GAS, REFINERY
Qualification
DIPLOMA IN ELECTRICAL ENGINEERING FROM GOVERNMENT POLYTECHNIC
COLLEGE,BULDHANA,KHAMGAON,MAHARASHTRA,AFFILIATED TO MAHARASHTRA
STATE BOARD OF TECHNICAL EDUCATION .COMPLETED IN YEAR 2010.
Knowledge and Skills:
i. Knowledge of Plant Maintenance
ii. Involving VCB,MOTORS,SF6,TRANSFORMERS, PM activities and Daily,Monthly Energy
Reading and update to management on daily basis,
iii. Maintenance and maintain the records.(ABB-UNIGEAR,Schneider – Switchgear - 11KV,13.8KV
,SIEMENS,MERLINGERIN Mc-set) .
iv. Maintenance of MOTORS AND TRANSFORMERS
v. Maintenance of motors, ups with battery backup .
vi. Knowledge of Maintenance in Variable frequency drives system (Ansaldo- convert
team,ABB-ACS 1000/800 and Emerson Network Power),Soft starter(ABB,Leory Somer)
vii. Trouble shooting and overhauling of all A.C HV/LV Motors ,
Familiar with
i. Operation and Maintenance of HT and LT Switchgears
ii. Operation and Maintenance of HT and LT Motors
iii. Understanding the Single Line Diagram of Electrical Systems
iv. Drives and UPS
SOFTWARE SKILLS
MS office, CMMS, outlook, SAP, MAXIMO,EPTW
WORK EXPERIENCE:
1. PROJECT : OPERATION AND MAINTENANCE PROJECT-KUWAIT
COMPANY : ABJ ENGINEERING AND CONTRACTOR-KUWAIT
POSITION : Electrical Senior Technician
CLIENT : KUWAIT OIL COMPANY (KOC)-NORTH-KUWAIT
DURATION : February -2023 to TILL NOW
Roles and Responsibilities:
Handling of Gathering Centers and CENTRAL INJECTION PUMP FEEDER (Water Treatment Plant ) units
in Kuwait oil Company.
• Maintenance of 132/11KV Substation
• Maintenance of 11KV Vaccum Circuit Breaker- Make TAMCO Switchgear and ABB .
• Maintenance of 440 V Switchgear Panels.- Make Al-Ahleia switchgear and ABB.
• Maintenance of UPS and Batteries - Make - Emerson Network Power.
• Maintenance of Distribution Transformers - 1500 KVA,2500KVA .
• Maintenance of Diesel Generators of about 2.0 MW - Make CaterPillar and Cummins.
• Maintenance of Ring Main Unit of 11KV- Make ABB.
• Maintenance of Motors - 35KW to 800 KW.
• Installation and Testing of Transformers ,Switchgear Panels.
• Maintenance of Variable Static Drives - Make Schlumberger.
• Power isolation and restoration using LOTO (Lock Out Tag out) system up to 11KV Level.
• Chiller Motor 621 kw, HP Cooling Water Pump 425 kw (11 kV VCB)
• LP & HP Air Compressor – 2.5 MW Make ABB Motor (11kV VCB)
• Gas Compressor - 1700 kw, Make ABB (11 kv Vacuum Contactor), 1750 kw, Make ABB, 3650 kw,
Make ABB Operated Using VSD system 11kv/3.3kv.
• Ensuring availability of required materials, spares and equipment, assigning subordinates.
• Generation preventive and corrective maintenance work orders.
• Supervising the executions of day-to-day preventive and corrective maintenance activities related to
the assigned field.
• Evaluate and study the contracts and tenders for all the company and contractor.
• Manage all mobilization and demobilization activities related for contracts.
• Maintenance and Troubleshooting for Gas and Diesel Generators CATERPILLAR and PERKINS
• Maintenance and Troubleshooting for Air Compressors Ingersoll and Kasser.
2. PROJECT : OPERATION AND MAINTENANCE PROJECT-INDIA
COMPANY : BONACE ENGINEERING –INDIA
POSITION : Electrical Technician
CLIENT : CAIRN OIL AND GAS-INDIA
DURATION : December -2020 to December -2022
Roles and Responsibilities
• Commissioning and Maintenance of HV/MV/LV Panel(PCC, MCC)also Motor and Transformer feeder
• Maintenance and commissioning of MV & LV switchgear.
• Work carried out Motor PM & Motor Overhaul job, MCC, PMCC, PDB panel PM, Heat Tracing
System Testing & PM, Power Isolation & Restoration done, DTR Preventive Maintenance, ACB, VCB
and Vacuum Contactor PM activity done.
• Preventive maintenance done of 132/33/11 kv and 6.6 kv GIS switchgear and SF6 breaker testing and
maintenance done.
• Condition monitoring and preventive maintenance and breakdown maintenance done of electrical
equipments.(VFD, MCC panel, PMCC panel, LT/HT Motor, ACB, VCB, DTR etc.)
• Condition monitoring and preventive maintenance done VFD (Siemens).
• Maintenance of 132/33/11 KV Substation.
• Isolating and De –isolating of Switchgear
3. PROJECT : OPERATION AND MAINTENANCE PROJECT-SAUDI ARABIA
COMPANY : AYTB (Al Yusr Industrial Contracting Company)-SAUDI ARABIA
POSITION : Electrical Foreman -Maintenance
CLIENT : SAUDI ARAMCO- FADHILI GAS PLANT-REFINERY –SAUDI ARABIA
DURATION : January -2018 to November -2020
Roles and Responsibilities
• Maintenance of 380KV/13.8/11KV Substation and 11KV and 6.6KV switchgear .
• Maintenance of Motors ranging from 35 KW to 750 KW.
• Maintenance of Power Transformers and Distribution Transformers.
• Performing safe low,medium and high-voltage electrical isolation including 400 V ,33 KV,11KV with
effective implementation of standard operating procedure like Loto.
• Operation and Maintenance of ABB switchgear make 11KV,33KV & 440V HT/LT electrical Power
System with protection relays.
• working with simens make MV variable frequency drives for motor control.
• .Preventive and Breakdown maintenance of HT/LT Transformers,HT/LT induction
• motors,VFD,UPS,Battery charger ,Emergency Generator,Processed desalter transformer MOV.
Installation,Testing ,Commissioning and Maintenance HV switchgear upto 66KV/33KV gas insulated
switchgear (ABB).66KV/33KV/11KV/6.6KV SF6 and Vaccum Circuit Breaker.
• Testing and Maintenance for starter of HV and LV and Motor Management relay/ contactor
starterters,DOl ,Star ,Delta.
• Maintenance of Substation Equipment
• such as Switchgear,UPS and Battery Chargers and Power Transformers with OLTC and Distribution
Transformers .
• Supervising the executions of day to day preventive and corrective maintenance activities related to the
assigned field.
• Generation preventive and corrective maintenance work orders.
• Setting priorities, determining appropriates standard procedures.
• Ensuring availability of required materials, spares and equipment, assigning subordinates.
• Supervising the actual execution of work on site or in workshop.
• Investigate and troubleshoots maintenance problems.
• Implementing the company’s work procedures and permit to work.
4. PROJECT : OPERATION AND MAINTENANCE PROJECT-India
COMPANY : LARSEN AND TOUBRO ELECTRICAL AND AUTOMATION-INDIA
POSITION : Electrical Technician
CLIENT : NAYARA ENERGY (FORMERLY KNOWN AS ESSAR OIL AND GAS-INDIA)
DURATION : July -2010 to December -2017
Roles and Responsibilities:
• Testing and Maintenance of Transformers 132 KV, 120 MVA, oil and hermetically sealed types.,
insulation resistance,stimulation,energisation fault investigation, rectification, testing and maintenance of
transformers and its accessories, Oil die electric strength (Break Down Voltage test),DGA Test,Buckolz
relay functional check.
• Testing and Maintenance of switchgear
• 11 KV. SF6, Vacuum, Air, and Oil circuit breakers, power and motor control centers, isolators, bus ties
and bus duct systems., general maintenance including contact resistance, insulation test, service checks,
and fault investigation.
• Operation and maintenance of Power control centre and motor controlling centre with different type of
breaker, contactor and control system.
• Testing and Maintenance of Up to 11 KV. 2500KW Motor, covering inter loop test, P.I. test, insulation
resistance test. Rectification of faults and general maintenance.
• Maintenance of Up to 120 KVA UPS in different manufactures, all type of batteries covering
maintenance and fault rectification.(FIAMM,ALCAD).
• Installation ,Testing and Maintenance of 11/0.415KV ,500KVA Transformers. 11KV panels.
• Isolation and deisolation of 11KV switchgears.
• Manage and coordinates all activities regarding to maintenance activities for all departments.
• Supervising the executions of day-to-day preventive and corrective maintenance activities related to the
assigned field.
• Generation preventive and corrective maintenance work orders.
• Setting priorities, determining appropriates standard procedures.
• Ensuring availability of required materials, spares and equipment, assigning subordinates.
• Supervising the actual execution of work on site or in workshop.
• Investigate and troubleshoots maintenance problems.
• Implementing the company’s work procedures and permit to work.
• Following up the Client’s approvals for the completed maintenance jobs.
PERSONNEL INFORMATION:
Date of Birth : 20.05.1990
Marital Status : Married
Gender : Male
Passport Details:
Passport Number : Z3537355 (ECNR)/ISSUED IN INDIA
Passport Issued Date : 22/01/2016
Passport Expiry Datae : 21/01/2026
Kuwait Civil id 290052013661
Address Information:
Present Address: ABJ ENGINEERING AND Contracting – Workers Camp- SULAIBIYA-Kuwait
Permanent Address: Building Number : 87/1119-d-2,Revenue Colony,Kalyani Nagar,Back Side of Vijaya
Hospital-Kurnool-Andhra Pradesh –India.
Language Known: English,Arabic and Hindi
Declaration:
I hereby declare that the above-mentioned information is correct up to my knowledge and I bear the
responsibility for the correctness of the above-mentioned particulars.
Date: 2024/08/07
Place: Kuwait (SYED ABRAR UL HAQ)