Advanced Protection Relay Tester TRTS46VI

The TRTS series Protection Relay Tester is a sophisticated device designed for testing protective relays in power supply networks, featuring 10 independent output channels for voltage and current. It offers advanced capabilities such as precise calibration, various waveform generation, and comprehensive safety features including overload protection and automatic alerts. The system is user-friendly with software compatibility for Windows and supports dynamic testing with GPS synchronization.

Uploaded by

reltecempmails
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views10 pages

Advanced Protection Relay Tester TRTS46VI

The TRTS series Protection Relay Tester is a sophisticated device designed for testing protective relays in power supply networks, featuring 10 independent output channels for voltage and current. It offers advanced capabilities such as precise calibration, various waveform generation, and comprehensive safety features including overload protection and automatic alerts. The system is user-friendly with software compatibility for Windows and supports dynamic testing with GPS synchronization.

Uploaded by

reltecempmails
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TESTREL

UNIVERSAL TEST SYSTEM

PROTECTION RELAY TEST SET


A protective relay test includes the review of protective devices in a
system. Protective devices and periodic reviews are very important
above all for the safe operation of power supply networks. The
protective relay test refers to the protective relay.

DESCRIPTION
10 Channels (4V + 6I) output.
.Each output channels are independent control of
magnitude, phase angle & frequency values,
can generate a variety of output waveforms such as:
DC; sinewave; sinewave with percent harmonics
at various phase angles etc.
Independent variable battery simulator
(DC 15~350V, 140watts)
Anti-clipping detect; cabinet grounding, wrong wiring
connect alarm and self-protect, overload and over heat
protection.
Test high burden electromechanical relays, 6x10A
continuously outputs. MODEL: TRTS46VI
Provide convenient and prompt precision calibration for
amplitude and phase by software without open the
cabinet.
SOFTWARE

ADVANTAGES

Size Optimized, Less weight(19.5kg)


Fully functions software
Allow advance state sequence
Ramping, overcurrent, distance BASIC MODULES ADVANCED MODULES
Differential, power swing
Synchronizer modules
energy meter modules (optional)

ADDTIONAL MODULES SETTINGS

SUPPORT
FEATURES

Graphical test modules and templates for testing of various relays


Quick relay testing facility in Manual mode
Point & Click testing
RIO/XRIO import and export facility
Switch on to fault (SOTF)
Power system model for dynamic testing
GPS sync end-to-end testing
Online vector display
Automatic compare actual characteristic with expected characteristic
Comtrade file generate and playback
Automatic test report creation

DEVICES CAN TEST


Chapter I Summary
1.1 System description

TRTS series Protection Relay Tester is a new generation protective relays testing system
based on chip microcomputer control assembled by TESTREL. developed by Kingsine
which is based on digital phase-locked patented algorithm and SPWM technology developed
of the current advanced SOC design concepts, and has high precision and high efficiency,
high stability signal amplifier of the world's advanced level, and provide users the test solution
with comprehensive, complete functions, and easy operation.

Chapter IIPerformance characteristics


2.1 Hardware

Excellent linear current/voltage amplifier

l Adopting efficient importing modular power and high fidelity digital audio power amplifier
of independent research and development for high-power output.
l High reliability.
l Output waveform is smooth real, no burrs, no the high harmonics produced by switching
amplifier.
l The true accurate small current waveform without any electromagnetic pollution.
l No current/voltage transformer in current/voltage generator on direct coupling mode, so
can output frequency 0-1000Hz range of DC and any desired frequency AC
voltage/current, 3KHz at transient output; such as square wave, exponential function
waveform and the superposition mixed waveform to meet e transient test requirements of
the protection device, and achieve the simple simulation testing of various protection
Testers.

Excellent amplitude frequency characteristic and transient response

l adopting the latest DSP and programmable logic FPGA of USA TI company with 1448
waveform simulation precision, and has the better transient response, more suitable to
the new development direction of microcomputer protection relays.
l Domestic unique 20-bit serial DA for further output precision improvement.

True current/voltage output at the same time and individually continuous


adjustable Amplitude /Phase /Frequency

l 10-channel output with varying amplitude, frequency, phase of 6I+3U+UX at the same
time

-1-
Different Types of TRTS series:
Model Voltage Outputs Current Outputs Optional Function
TRTS76VI 7×310V @ 90VA max 6×35A @ 450VA max
3×70A @ 850VA max
TRTS46VI 4×310V @ 124VA max 6×35A @ 450VA max ● Energy Meter Cal.
3×70A @ 850VA max
TRTS43VI 4×310V @ 124VA max 3×35A @ 450VA max

Perfect protection function

l Automatic alerts and protects while main AC power input out of the permission range.
l While power switched on, it will automatic detect the input power and the buzzer will beep
4 times;
l If input power out of range, it will self-protected and continues beeping.
l Voltage generator has overload/short-circuit protection function, clipping distortion
detection function on outputting, error-wiring judgment alarm and self-locking protection
function; Voltage generator can monitoring circuit and automatic closing voltage amplifier,
and then issued a warning buzzer., voltage amplifier is automatically restored to normal
state after Short circuit or overload disappears
l While Tester overheat on long time High-current output or current loop overloading,
temperature protection monitoring circuit will automatically close current amplifier, then
panel overheating indicator immediately lit, and issued a warning buzzer; The current
amplifier is automatically restored to normal work. After the temperature drops to the
allowable range.
Open-circuit indicator of Current generator
l While the current output terminals open circuit, the panel indication corresponding to IA,
IB, IC, IR, IS, IT open circuit will turn on.
l This function is working when we inject current value greater than 0.05A and without
wire connection on terminal port. The LED will turn on red.
l If the channel output current less than 0.05A, the indicate LED will not working.(It may
turn on or turn off random). the device is working normal.
Unique heat radiating Parts
l Adopting unique heat dissipation component and the temperature protection measure for
the excellent stability and reliability power amplifier in the large current, long time working.
l Built-in four large-power exhaust fan
High vibration resistance
l The Tester used the building frame structure inside and has an excellent vibration
resistance function.
l High strength aluminum alloy Packaging box for vibration resistance and shock
resistance.

-2-
Convenient and quick field DC voltage supply (Battery simulator)
l 0-350V/0.38A programmable auxiliary DC power output by software control, which can
provide working power supply separately to the protection Tester as well as other Testers.

2.2 Software
Perfect on-line testing function
l manual or automatic testable respectively to various types protective relays of voltage,
current, frequency, power, impedance, harmonic, differential and contemporaneous
relays; it can also simulate all kinds of fault types for distance and zero sequence
protection relays setting check and Re-closer testing of protection relays; it can test
Self-input device, fast changing-over device and etc. with GPS trigger function..

Good online compatible system


l PC software suitable to Windows XP\ Windows 7 \ Windows 10 operating systems.
l Friendly and humanized Windows style interface.
2.3.1 Connection and interface
A AC/DC current output ports, and corresponding open-circuit indicate LED.
B AC/DC voltage output port (UR,US,UT available for model K3066i only)
C Auxiliary DC voltage output
D Binary Inputs 1, 2, 3, 4
E Energy meter test interface
F Power, Run, Overheat, Voltage short, LED indicator.
G Binary inputs 5, 6, 7, 8
H Binary outputs 1,2,3,4
I RJ45 Ethernet socket, for PC control
J GPS antenna connector, SMA type
K Main power switch and socket.
L grounding port (ensure reliable grounding,
otherwise might cause low accuracy output or the tester damage)
M Quick binary outputs 5~8, collector open type, Maximum voltage allowed
+15V.

-3-
2.3.2 AC&DC Current
l It is independently adjustable in six phase current output channels: IA,IB,IC,Ia,Ib,Ic; i.e.
To simultaneously output different frequency values, amplitude values, phase values.

2.3.3 AC&DC Voltage


l It is independently adjustable in four phase voltage output channels:
UA,UB,UC,UX(AUX.AC);
i.e. To simultaneously output different frequency values, amplitude values, phase
values. Output range is from 0...350V

2.3.4 AUX.DC
l The output values of Aux. DC Source are adjustable by KRT software, output range 0~
350V/0.38A

2.3.5 Bin. I/O


l Binary output capacity 300V/8A
l Binary input is compatible with dry contact and electric potential free

2.3.6 Signal LED


l “Power” LED indicate the main power status; if main input power out of range, inside
buzzer will continues beep until the input power detects correct.
l “Run” LED indicate the kit is injecting voltages and currents; It is controlling by PC
software.
l “V short” indicates short circuit or overload when LED V Short is on.
l “Overheat” indicates OVERHEAT PROTECTION is activated when LED OVERHEAT is
on, the protection will be dismissed after device cool down.

-4-
2.3.7 Pulse I/O port
Pulse input & output wire is connect to pulse I/O port, it is for the purpose of energy test. K30
series relay test set supports I/O connection test on pulse output of the device.
5V +5V output
IN Pulse input
OUT Pulse output
COM: Ground
2.3.8 RJ45
RJ45 is a standard 10/100Mbit twisted-pair cable Ethernet interface Usually
used for communication between the test device and the object of being test.
RJ45 interface supports auto crossover (Auto MDI / MDIX). This means that
user can use a standard Ethernet cable.
The green LED in bottom left of front panel indicates that the connection to
the PC or to network has been established. If there is data communication
on cable (send-out or reception), the bottom right of the yellow LED lights will be on.

2.3 System parts


Please check if everything is ready according to packing list when user start operation on
relay test set for the first time. User need these parts as follow
▪ KRT protection relay testing software
▪ Electrical testing leads
▪ Power Supply cord
▪ Ethernet cable
Safe use of wire connection

Multiple adapters can be free connected to facilitate on-site testing.

There is naked terminal end in adapter. Thus, users are supposed to shut down the
output of current/voltage before user connect with these adapters. During the connection,
please firstly have naked terminal end of adapter insert into terminal slot, screw them tight,
and then to connect to the test leads concerned.

-5-
2.4 Start up testing system
1. Install TRTS software on the PC.
2. Connect the Ethernet cable to PC (connect to RJ45 port).
3. Connect power supply for K30 relay test set.
4. Power on both the test kit and PC.
5. Run TRTS relay test software, entry into “connect” ( Connect instruction refer to the TRTS
relay test set user manual at page 10)

Network Cable

Note: The relay test kit and Laptop IP address shall be set on the same Intranet network, IP
address setting on KRT software must same as real test kit IP address was searched by
"Search" button, it can be checked connection status via PING command on Laptop.

2.5 GPS introduction

Test set already built-in GPS module, it can be used for end-to-end testing when connect to
GPS antenna.

2.6 Cautions for GPS using


When run the GPS receiver, received and decoded low frequency wireless signal by satellite.

If there were wireless equipment or electron used nearby, it might cause EMI to effect

receiver and decoder working. Please close the interfering signal or move away the GPS

receiver in order to reduce or remove interference.

-6-
Technical parameter and characteristics
Technical parameter (Based on TRTS6V6A)

AC voltage output
6 phase AC(L-N) 6×0...300 V
Output range
2 phase AC(L-L) 2×0...600 V
6×300 V (L-N) 6×124 VA max
Power
2×600 V (L-L) 2×180 VA max
±2 mV @ 0.2~2 V ac
Accuracy <0.03%Rd + 0.02%Rg Guar. 2...310 V
<0.03%Rd + 0.01%Rg Typ. @ 2~310V ac
Resolution 1mV
AC current output
Output range 6 phase AC(L-N) 6×0...35 A
6×35 A(L-N) 450 VA max / each
Power 3×70 A(2L-N) 850 VA max / each
1×180 A(6L-N) 1×1200 VA max

<1 mA at 0.2 ...0.5 A

Accuracy <0.05%Rd + 0.02%Rg Guar. @ 0.5~35A ac

<0.03%Rd + 0.02%Rg,Typ. @ 0.5~35A ac

Resolution 1mA
Others
Range 0...1000 Hz, 3000Hz transient

<0.001 Hz at 0...65 Hz

Frequency Accuracy <0.01 Hz at 65...450 Hz

<0.02 Hz at 450...1000 Hz

Resolution 0.001 Hz

Range -360°...360°

Phase Accuracy <0.2°

Resolution 0.1°

Timing range 0.1 ms ... 1.5×105 s


Timing function
Timing accuracy <1 ms

-7-
DC output
Range 0...350 V/120 W
DC voltage <10 mV at 0.5 ... 5 V
Accuracy
<0.5% at 5 ...350 V
Range 0..20 A/300 W
DC current <5 mA at 0.2 ... 1 A
Accuracy
<0.5% at 1 ... 20 A
Auxiliary DC voltage
Range 0...350 V/0.4 A
Binary input
Quantity 8 pairs, day/wet compatible

Compatible voltage 12 V...300 Vdc


Binary output
Quantity 4 pairs
Capacity 300V/8A (AC/DC)
Harmonic
Superimposing times 2...63tims
Power supply
Rated voltage 110/220/230VAC preselected
Power supply range +/-20% of rated voltage, Maximum 264VAC
Power 1500 VA
Power frequency 47 Hz...65 Hz
Operational environment
Operation temperature -25℃…70℃
Humidity ≤95%,non-condensation
Others
Dimension 490(D)×362 (W)×155 (H) mm
Weight 20 kg
Connect port RJ45

TESTREL,
NO.12, SRS ROAD PEERNYA 1ST STAGE,
BANGALORE -58 , INDIA
MOB : 9448040046, 9964441111