Scott Pressur-vak II

Application
The Pressur-Vak II is used primarily for sur-
face decompression in a recompression cham-
ber and is not intended for use underwater. It
may also be used on other applications which
require overboard discharge of exhaled gases.
The Pressur-Vak II provides oxygen or gas
mixture without affecting the chamber envi-
ronment.

ORDERING INFORMATION:
803139 Basic configuration includes:
- Demand Regulator Assembly
Pressur-Vak II P/N-800954-01
Inhalator with overboard discharge 803139 - Exhaust Regulator Assembly
series. P/N-801274-00
- Hose Assemblies- Demand & Exhaust
Description P/N-803166-01
The Pressur-Vak II is a pressure-vacuum sys- - Manifold Assembly
tem consisting of a new hardshell/softseal P/N-803100-01
facepiece which is available in four sizes - Face Seal and Harness Assembly
(short, regular, long, extra long). P/N-803152-XX
The unit consists of a demand
regulator for oxygen and helium-oxygen mix- Features:
tures, a vacuum regulator to exhaust user’s ex- *Long duration comfort with new hardshell/softseal
facepiece. Available in four sizes.
halation, a quick disconnect
*Interchangeability of facepieces through the use of
demand and exhaust regulator manifold, and the new quick disconnect manifold regulator
supply and exhaust hose assemblies. assembly.
Low pressure gas flows through a *Exhausts exhaled gases overboard, permitting
lightweight flexible hose to the demand minimum ventilation of the chamber.
*Reduces decompression time, using Navy oxygen
regulator. The exhalation is removed through decompression tables.
the vacuum regulator. *Optional first stage pressure-reducing regulator
The regulator exhaust is connected by a hose to permits breathing gas inlet pressures from 300 to
the outside of the chamber. For a pressure dif- 3000 psi. Maintains constant inlet pressure to the
ferential in excess of 60 feet or water, a second demand regulator.
*Control knob on demand regulator permits constant
vacuum regulator must be connected between flow operation.
the hose and chamber wall to limit the differ- *Small diameter pressure and exhaust hoses provide
ential maximum maneuverability.
pressure across the vacuum regulator on the
manifold. An interlock valve should be an inte-
gral part of the system as a safety device to 803139 - XX - XX
shut down the vacuum should a pressure loss Pressure reducing regulator assembly Face seal selection
occur. In some cases, the vacuum system may with - press. red. reg. 00 - .01 short
be the differential pressure between the inside w/out - press. red. reg. 01 - .02 regular
- .03 long
and outside of the chamber. - .04 x-long

example:
803139 00 04

basic configuration
with pressure reducing reg.
with x-long face seal

Hyperbaric Technology B.V.


Bliek 16 - 4941 SG - Raamsdonksveer - The Netherlands
+31 (0)162 522202 +31 (0)162 519069
[email protected] http://www.hytech.nl
Scott Pressur-vak II
PARTS LIST SCOTT PRESSUR-VAK II 803139-00

Item Part no. Description QTY REQ’D


A-1 **803152-01 Faceseal Assy, short 1
A-2 **803152-02 Faceseal Assy, regular 1
A-3 **803152-03 Faceseal Assy, long 1
A-4 **803152-04 Faceseal Assy, X-long 1
A-5 803115-01 Harness (straps only) 1

B-1 803100-01 Manifold 1


B-2 2800C125A O-Rings, Regulators to Manifold 2
B-3 21506-0 O-Ring, Manifold 1
B-4 N/A Illustration only NA

C-1 **800954-01 Demand Regulator Assy. 1


C-2 800956-00 Case, Regulator, Demand NA
C-3 26004-01 Diaphragm, Demand Reg. 1
C-4 801276-00 Cover 1
C-5 26010-01 Clamp 1
C-6 26021-01 Valve Stem 1 N/A
C-7 13796-00 Valve Spring 1 N/A
C-8 13685-00 Valve Clamp 1 N/A

D-1 **801274-00 Exhaust Regulator Assy. 1


D-2 801275-00 Case, Regulator, Exhaust 1
D-3 801272-00 Diaphragm & Stem Guide Assy. 1
D-4 10003027 Cover, exhaust Regulator 1
D-5 26010-01 Clamp 1
D-6 800963-00 Exhalation Valve 1
D-7 13796-00 Valve Spring 1

E-1 **803166-01 Dual Hose Assy. Complete 1


E-2 2827-49 Gasket, Demand Hose 1
E-3 26037-09 Demand Hose Assy. 10 ft. 1
E-4 58719-01 Exhaust Hose, 10 ft. 1
E-5 10002573 Hose Grommet 3
E-6 18970-00 Hose Plug, Demand Hose 1
E-7 59852-00 Hose Plug, Exhaust Hose 1
E-8 20433-00 Hose Clamp 2

F-1 59853-00 Quick Disconnect Socket 3/8” 1


F-2 18969-00 Quick Disconnect Socket 1/8” 1

F-3 B-6QDP Exhaust Plug (59853-00 Socket)


Optional

H-1 **801804-00 Pressure Reducing Reg. Complete 1


H-2 8580-00 Oxygen Coupling 1
H-3 58370-00 Regulator, Pressure Reducing 1
H-4 6818-3 Plug-Regulator 1
F-2 18969-00 Quick Disconnect Socket 1/8” 1

N/A - Not available as spare part


** - Top assemblies

Note: for drawing references, please see next page!

Hyperbaric Technology B.V.


Bliek 16 - 4941 SG - Raamsdonksveer - The Netherlands
+31 (0)162 522202 +31 (0)162 519069
[email protected] http://www.hytech.nl
Scott Pressur-vak II

Hyperbaric Technology B.V.


Bliek 16 - 4941 SG - Raamsdonksveer - The Netherlands
+31 (0)162 522202 +31 (0)162 519069
[email protected] http://www.hytech.nl

You might also like