0% found this document useful (0 votes)
15 views30 pages

PCS Introduction

The document outlines the pain points associated with traditional Power Conversion Systems (PCS) for Commercial and Industrial (C&I) energy storage, highlighting issues such as lack of flexibility, safety concerns, and inefficiencies. It also introduces Deye Smart Energy Solutions, which offer advantages like flexible expansion, cost-effectiveness, and high efficiency. The document emphasizes the importance of smart monitoring and advanced design features to enhance system performance and reliability.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views30 pages

PCS Introduction

The document outlines the pain points associated with traditional Power Conversion Systems (PCS) for Commercial and Industrial (C&I) energy storage, highlighting issues such as lack of flexibility, safety concerns, and inefficiencies. It also introduces Deye Smart Energy Solutions, which offer advantages like flexible expansion, cost-effectiveness, and high efficiency. The document emphasizes the importance of smart monitoring and advanced design features to enhance system performance and reliability.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

St oc k Cod e:605117

Dey e Sm a rt
En erg y Solu t ion s
Pow erin g You r Life
Pain Points For PCS C&I Energy storage
Lorem ipsum dolor sit amet, consectetur adipisicing
Pains

1. Not Flexible to expand PCS 6. Traditional PCS can’t be transported


System smoothly because of the weight etc.

2. Weak design on safety, Power


5. Weak adaptive design on high altitude,
surge,reliability etc.
high/low temperature, Coastal area etc.

3. Weak design on whole system 4. Weak Smart Monitoring


efficiency Design
Pain 1 Not Flexible To Expand PCS System

Traditional PCS setups are typically built as fixed, rigid


systems, meaning they lack the ability to scale and
adapt as your energy needs grow or change.
1
Pain2 Weak design on safety, Power surge, reliability

Poor Thermal Management


Lack of efficient heat dissipation measures

Insufficient Isolation Protection


Inadequate isolation between high-voltage DC
and AC circuits can lead to dangerous voltage
leakages

Low-Quality Power Surge Protection


Without robust surge protection, PCS systems can
be vulnerable to voltage spikes

Weak Battery Management


If PCS lacks tight integration with BMS, it can lead to poor
monitoring of battery status, risking overcharging,
overheating, or under-voltage conditions
Pain3 Weak design on whole system efficiency

<90% <95%

Round Trip Efficiency( % ) = ( Discharge


Energy/ Charge Energy ) ﹡100%
Pain4 Weak Smart Monitoring Design

Limited Remote Poor Data Analytics Low Scalability Weak Integration Low Cyber Security
Access and Control and Insights

Making it difficult to Making it challenging to create a Cyber security


Lack robust Remote Function Struggle for below and creating
extract valuable insights unified monitoring solution weakness is critical to
bottlenecks as systems grow.
from operational data. ensuring below

Travel to site to No detailed fault Integrate seamlessly Resilience and safety of


Do not support Handle large Can’t integrate new
Investigate info. remotely with other modern PCS system
advanced analytics volumes of data Devices
management
Pain5 Weak design on special conditions

High Altitude Low Temperature High Temperature Sand & Dust

Altitude-rated cooling temperature-controlled


mechanisms enclosures Advanced Heat Sinks proper filtration

Insulation enhancements heating elements Cooling Fans Conformal Coating


Pain6 Logistics And Installation
Pain6 Logistics
1 Heavy and Bulky
Heavy and Bulky Complex Installation
Complex And
Installation
Components
Components Commissioning
 Traditional PCS PCS
 Traditional systems oftenoften
systems include below,
include making
heavy  The installation process for traditional PCS

the transformers,
equipment bulky andheat
large challenging to multiple
sinks, and transportpower
and  The installation process
systems can for traditional PCS systems can
be complex

handle
electronics components, making the equipment bulky be complex due to the multiple components and

and challenging to transport and handle connections involved, which may require specialized

technicians or engineers on-site.


Heavy transformers, large heat sinks, and Require specialized technicians or
 Special
multiple transportation
power vehicles
electronics and equipment (e.g.,
components
Long Distance Logistics engineers on-site
forklifts, cranes) are usually required, adding to costs
 Extended installation and commissioning times can
and complicating logistics, especially in remote or
increase costs, delay project timelines, and create
 Conditions below arelocations.
rugged usually required, adding  Extended installation and commissioning times can cause
logistical hurdles in coordinating different teams and
to costs and complicating logistics, especially in below, and create logistical hurdles in coordinating
equipment on-site.
remote or rugged locations. different teams and equipment on-site.

Transportation vehicles High Delivery Cost Increase Cost Delay Project Timeline
Deye ESS Introduction
Lorem ipsum dolor sit amet, consectetur adipisicing
Industrial & Commercial Storage System Key Advantages

Flexible
Expansion And Allowing up to 20 units to be paralleled For 2MW
Delivery

OFF GRID
On-Grid and Off-Grid Compatibility with Generator Support
Design

Approximately 30% more cost-effective than traditional


Cost
containerized storage systems
Advantage

Shock
170% Instantaneous Peak Power Output
Resistance

Exporting Current
Limitation Control
Independent Three Phase Exporting Current Limitation Control
Flexible Expansion

Allowing up to 20 Units to be
paralleled for MAX capacity

of 2MW
Flexible Delivery

Microwave

MPPT Module 543×660×198mm

Small Washing Maching

PCS Module
543×775×310mm

Dish washer

Deye 80-100K PCS STS Module 543×796×575mm


Flexible On-Grid and Off-Grid Compatibility with Generator Support

Provide smooth switching between on-grid and off-


01 grid modes

Support generator input and control, making it adaptable


02 to a range of scenarios

03 MAX 2MW Off Grid Pure Sine Wave OUTPUT

04 Switching Time from Grid to Off Grid < 10 ms


High Efficiency Design
Cost Advantage

Approximately 30% more cost-effective than traditional containerized storage systems

30%
Shock Resistance

170% Instantaneous
Peak Power Output

Capable of deliverying up to 170% peak power output


momentarily, the system meets sudden high-power
demands with ease. This feature is particularly valuable in
environments with heavy-load equipment start-ups or
fluctuating factory power requirements, ensuring a stable
power supply
Independent Three Phase Exporting Current Limitation Control

Three Phase
Other Inverter manufacturers
unbalance
Still Exporting When
Unbalance on 3 Phases

Deye I&C Storage System Exporting 0 When


Unbalance on 3 Phases
Industrial & Commercial Storage System With MPPT Solution
Industrial & Commercial Storage System With MPPT Solution

MPPT Module Integrated Solution

System Layout
Industrial & Commercial Storage System Without MPPT Solution
AC Couple System Layout

NO MPPT Module Solution


• 21 PCS in Series,
7.68KWh / PCS

• Battery Voltage
Range 630-1000V

• Max
Charging/Dischargi
ng current 175A
Industrial & Commercial Storage System 1MW Solution

1MW Solution
Industrial & Commercial Storage System 2MW Solution

2MW Solution
High Efficiency Design

Battery Packaging Technology Battery Management Technology Remote Maintenance Technology

Flexible Configuration and Cell, Switch Box, Battery Pack 3 Remote Monitoring, App-Based Fault
21 PCS in Series, 7.68KWh / PCS
expansion Level Protection, Layered Control Diagnosis, Maintenance-Friendly
High Efficiency Design

Mature System Topology, Leading Circuit Design

3 Level Technology Pure Sine Wave


High Reliability Design
Smart Monitoring Design

 Key system information monitoring for PCS and Battery

 Operational Power Dispatch, Fault and Alarm Logic


Management

 Battery Balancing Management Among Energy Storage


Subsystems

 Local monitoring, Unified Dispatch


485 Communication Solution
Thank You!

You might also like