InteliLite 4
AMF 25
Order code: IL4AMF25BAA, IL4AMF25BLA
Controller for single gen-set applications
Datasheet
Product description
Advanced single Gen-set controller for stand-by and prime-power RTC with battery back-up, full calendar and enhanced scheduler
applications Detailed history log with up to 350 records, including user logins and configuration
changes
Key benefits Remote Display support via RS485 (special RD FW for InteliLite 4 controllers)
Great flexibility and wide range of application support Up to 5 languages in one configuration, over 20 default languages available, and an
easy to use Translator
Variable predefined configurations tailored for specific applications
Load shedding and dummy load management
User defined protections and setpoints, integrated PLC logic
Alternative configurations for genset with variable voltage and frequency
Full control with fast and reliable remote communication support
Tool for quick and organized configuration cloning in large production facilities
Built-in USB host/device, CAN, RS485 interfaces
Available in low temperature version (order code: IL4AMF25BLA)
Extendable options including 4G/GPS, Ethernet and RS485/RS232
Support of Modbus RTU/TCP, SNMP v1/v2c/v3, J1939 protocols
Application overview
Cyber security by design to safeguard your business
Designed in relevant requirements according to ISA 62443 level 2-3
Enhanced ECU support
StageV and Tier4Final ready by default with additional customisation
MultiECU support for enabling communication with more J1939 devices such as
engine ECUs, battery chargers, AVRs etc.
Key features
4 applications in 1 HW: AMF (Stand-by) – default, MRS (Prime-power), Hybrid,
Engine
Monitoring via WebSupervisor, InteliSCADA, InteliConfig, active SMS and e-mails
or external SCADA system
Improved HW platform
Switchable analogue inputs (R/U/I)
5 V reference output for analogue CU AIN Calibration
2 high-current E-Stop binary outputs
2 slots for extension plug-in modules (more binary I/Os, 4G & GPS, Ethernet, RS232
& RS485)
Geo-fencing based on GPS
Support of up to 5 extension CAN modules
Power over USB for configuration without standard power supply
| InteliLite 4 AMF 25 Datasheet | Related HW ver: 1.0 | Related SW ver: 1.7.1 | Date of issue: 2/6/2025
Dimensions, terminals and mounting
Note: The final depth of the controller depends on the selected plug-in module – it can vary between 41 mm
and 56 mm. Mind also the size of connectors and cables (e.g. in case of RS232 connector, add about 60 mm
more for standard RS232 connector and cable).
Note: The controller is to be mounted into panel doors as a standalone unit using provided holders. The
requested cutout size is 187 × 132 mm. Use the screw holders delivered with the controller to fix the controller
into the door.
InteliLite 4 AMF 25 Datasheet 2
Technical data
Power supply Current measurement
Power supply range 8-36 V DC Measurement inputs 3ph Gen current
Power consumption Measurement range 5A
3.5 W
(without modules) Max. allowed current 10 A
RTC battery Replaceable (3 V) Accuracy ±20 mA for 0-2 A; 1 % of value for 2-5 A
Fusing power 4 A w/o BOUT consumption Input impedance <0.1 Ω
E-Stop fusing 10 A
E-Stop
Max. power dissipation 9W
Dedicated terminal for safe E-Stop input.
Operating conditions Physical supply for binary outputs 1 & 2.
Protection degree (front Binary inputs
IP 65
panel)
Number 8
Operating temperature -20˚C to +70˚C
0-2 V DC close contact
Operating temperature Close/Open indication
-40˚C to +70˚C 6-36 V DC open contact
for Low Temp. version
Storage temperature -30˚C to +80˚C Binary outputs
95 % non-condensing Number 8
Operating humidity
(EN 60068-2-30) BO1,2=5 A (60°C); BO1,2=4 A (70°C),
Max. current
5-25 Hz, ± 1.6 mm BO3-8=0.5 A
Vibration 2
25-100 Hz, a = 400 m/s Switching to positive supply terminal
2
Shocks a = 500 m/s
Analog inputs
Surrounding air temperature rating 70°C
Suitable for pollution degree 2 Number 4, switchable (R/U/I)
Range R = 0-2500 Ω; U = 0-10 V; I = 0-20 mA
D+
R: ±2 % from value ±5 Ω in range 0-250 Ω
Max. output current 250 mA R: ±4 % from value in range 250 Ω-2500 Ω
Accuracy
Charging fail threshold Adjustable U: 1 % from value ±100 mV
I: 1 % from value ±0.2 mA
Voltage measurement
Measurement inputs 3ph-n Gen voltage , 3ph-n Mains +5 V Power supply output
10-277 V AC / 10-480 V AC (EU) Max. current 45 mA
Measurement range 10-346 V AC / 10-600 V AC
Magnetic pickup
(US/Canada)
Linear measurement 350 V AC Ph-N 4 Vpk-pk to 50 Vpk-pk in range 4 Hz to 1 kHz
Voltage input
and protection range 660 V AC Ph-Ph 6 Vpk-pk to 50 Vpk-pk in range 1 to 5 kHz
range
1% 10 Vpk-pk to 50 Vpk-pk in range 5 to 10 kHz
Accuracy
Frequency range 30-70 Hz (accuracy 0.1 Hz) Frequency input
4 Hz to 10 kHz
range
Input impedance 0.72 MΩ ph-ph , 0.36 MΩ ph-n
Frequency
Display measurement 0.2 % from measured value
tolerance
Type Build-in monochromatic 3.2"
Resolution 132 × 64 px
Communications
USB Device Non-isolated type B connector
USB Host Non-isolated type A connector
RS485 Isolated
Non-isolated, 250 / 50 kbps,
CAN
Terminator impedance 120 Ω
Modbus RTU/TCP
Protocols SNMP v1/v2c/v3
J1939
InteliLite 4 AMF 25 Datasheet 3
Available plug-in modules
Product Description Order code
CM-RS232-485 Dual port (RS232 & RS485) plug-in communication module CM223248XBX
CM2-4G-GPS 4G & GPS plug-in communication module CM24GGPSXBX
CM3-Ethernet Internet / Ethernet plug-in communication module CM3ETHERXBX
EM-BIO8-EFCP 8 additional binary inputs/outputs EM2BIO8EXBX
Note: Controller has 2 slots for plug-in modules.
Available CAN modules
Product Description Order code
IGL-RA15 CAN remote annunciator with 15 LEDs EM2IGLRABAA
Inteli AIN8 CAN module with 8 analog inputs I-AIN8
Inteli IO8/8 CAN module with 8 binary inputs and 8 binary outputs I-IO8/8
IGS-PTM CAN module with 8 binary inputs, 8 binary outputs, 4 analog inputs and 1 analog output IGS-PTM
Inteli AIN8TC CAN module with 8 analog inputs dedicated for thermocouple sensors only. I-AIN8TC
Inteli AIO9/1 CAN module with analog inputs and outputs – designed for DC measurement. I-AIO9/1
List of SW Key Features
SW Key Feature Order code
Modbus client for InteliLite 4 SKMODCLI03
Functions and protections
Support of functions and protections as defined by ANSI (American National Standards Institute):
Description ANSI code Description ANSI code
Voltage unbalance / Negative sequence
Master unit 1 47
voltage
Stopping device 5 Incomplete sequence relay 48
Multi-function device 11 Overcurrent 50/50TD
Overspeed 12 Earth fault** 50G
Underspeed 14 Breaker failure 50BF
Starting-to-running transition contactor 19 Overcurrent IDMT 51
Thermal relay 26 Overvoltage 59 (cat III)
Undervoltage 27 Aux Over Voltage 59X
Aux Battery Under Voltage 27X Pressure switch 63
Annunciator 30 Liquid level switch 71
Overload (real power) 32P Alarm relay*** 74
Reverse power 32R Reclosing relay 79
Master sequence device 34 Overfrequency 81O
Unit sequence starting* 44 Underfrequency 81U
Current unbalance 46 Auto selective control/transfer 83
*Dual operation **Extension module EM-BIO8-EFCP required *** extension module IGL-RA15 required
Certifications and standards
EN 61000-6-2 EN 60068-2-6 (2÷25 Hz / ±1,6 mm; 25÷100 Hz / 4.0 g)
2
EN 61000-6-4 EN 60068-2-27 (a=500 m/s ; T=6 ms)
EN 61010-1 EN 60068-2-30 25/55°C, RH 95%, 48hours
EN 61326-1 EN 60529 (front panel IP65, back side IP20)
EN 60068-2-1 (-20°C/16 h) UL 6200
EN 60068-2-2 (70°C/16 h)
E-mail: [email protected]
Web: www.comap-control.com
© ComAp. Features and specification are subject to change without prior notice.