Solar Power

The document provides a detailed load analysis for a solar power system, including demand factors, appliance watt ratings, and average usage. It outlines battery requirements based on average load and desired operating hours, as well as inverter specifications and solar panel characteristics. Additionally, it includes cost estimates and calculations for energy consumption and battery configurations.

Uploaded by

Francis Ybanez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
21 views8 pages

Solar Power

The document provides a detailed load analysis for a solar power system, including demand factors, appliance watt ratings, and average usage. It outlines battery requirements based on average load and desired operating hours, as well as inverter specifications and solar panel characteristics. Additionally, it includes cost estimates and calculations for energy consumption and battery configurations.

Uploaded by

Francis Ybanez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 8

Load Analysis

Demand Factor 0.75

Appliance Watt Rating Average Watt usage

AC 1.5 hp 1,119.00 500.00


Bulb (6W x12) 72.00 36.00
Fan (70W x 2) 140.00 112.00
Refrigeration (Inverter) 200.00 100.00
Solar Devices (Inverters & Controllers) 120.00 100.00
Others (Washing Machine & Iron 1,000.00 1,000.00
Peak Load 2,120.80 1,386.00
Average Hourly
Historical Data 24Hr (Watts - Hr)
Load (Watts)
Meralco Based Reading 500.00 12,000.00

Peak Load 1,386.00 Watts


Average Hourly Load 500.00 Watts
Average Daily Consumption (24hr) 12,000.00 Wh

Batteries
Calculate Number of Battery Based on Average Load
Desired Autonomous Operating Hours (DAOH) 24 Hours
Selected Battery Voltage (BV) 48 V
Battery D.O.D (DOD) 0.8
Select Battery Capacity 100.00 A-h
Average Daily Consumption (ADC) 15,000.00 W-h
Battery Storage Requirements (BSR) 390.63 Ah
Estimate Total Number Battery (24Hr Reserve) 3.91 Pcs
Adjusted Total Number of Battery 4.00 Pcs

Determine Battery Configuration


Single Array Configuration (P-Parallel or S-Series) S Enter "P" or "S"
Total Number of Batteries (TNB) 4.00 pcs
Array Current Capacity (Ah) 100.00 Ah
Array Output Voltage (AOV) 192.00 V
Array Power Storage(APS) 15,360.00 Wh

Inverter
Inverter Requirement Ratings Units
Peak Power (IPP) 640.00 Wats
Max Input Voltage 192.00 Volts
Input Current 3.33 Amp

SOLAR Panels
SOLAR PANEL 400.00 Watts

24Hr Demand (Watt-


STEP1 Determing Charging Capacity of Battery up to Sun-Hr
Hr)
D.O.D. of specified Batteries
15,360.00 4.00

SOLAR PANEL CHARACTERISTICS FOR LG LG400N2W-A5 (400W)

$
LG400N2W A5 ROSEN
Power (Watts) 400.00 500.00
Voc (Volts) 49.40 59.01
Vmp. 40.80 58.63
Imp (Amps) 9.81 10.29
Isc (Amps) 10.49 10.87
Peak Efficency 19.00 19.51

Charge Controller Specification Demands

Type MPPT
Solar Charge Type
Watts 15,000.00
Max. PV Array Power
Max. PV Array Open Circuit Voltage Volt DC #REF!
min Volt
PV Array MPPT Voltage Range
PV Array MPPT Voltage Range
max Volts #REF!

Maximum Solar Input Current Amp #REF!


Maximum Solar Charge Current Amp #REF!
Maximum Charge Current Amp #REF!

Battery Voltage Volt 192.00


Floating Charge Voltage Volt
Overcharge Protection Volt

Estimate Cost QTY U Cost


Solar Panell 400W 10
MPPT 96V 1
Battery 12V 250AH 8
Operating Hours Watt-Hrs per Day

4.00 2,000.00
12.00 864.00
12.00 1,680.00
24.00 4,800.00
24.00 2,880.00
1.00 1,000.00
13,224.00
Cost per Month
30 Day (kwH)
for 12/kwH
360.00 4,320.00
Adjusted Qty of
Panel

9.6 10.00

Maximum Power Output


Open circuit voltage
Maximum power voltage
Maximum power current
Short-circuit current
% Percent

Demand/
Glory M5000 HHP-48 Capacity Factor

MPPT

5,000.00 3.00

500.00 #REF!
120.00
450.00 #REF!

18.00 #REF!
80.00 #REF!
80.00 #REF!

48.00 4.00
54.00 0.00
63.00 0.00

Cost
Daily Power Demand 12,000.00 Watt-hr

Battery Specification
Amp Capacity 100 A-h
Voltage 24 V
D.O.D % 80.00%
Max Power Capacity 2400 Watt-h
Net Power Capacity 1920 Watt-h

0
Battery Array Capacity
Battery Quantity
Calculated Battery Quantity 6 pcs
Desired Number of Batteries 6.00 pcs
Battery 🔋 Array Configuration
Series 2.00 pcs
Parallel 3.00 pcs
Battery Bank in Array Configuration
Array Voltage 48.00 Volt
Array Ampacity 300.00 A-h
Max Energy Capacity 14400.00 Watt-h
Battery Bank Net Energy 11520.00 Watt-h
5760
NOTE:
Bank Net Energy Capacity - is the useable power that
can be used upto lthe level of depth of discharge
D.O.D. of the battery 🔋

Sample Energy Consumption Analysis / Calculator


Find Current drawn by a load, and number of hours can be
use before reaching Battery 🔋 D.O.D.
Load Parameter Watts Unit
Battery Bank Net Energy @ D.O.D. 11520.00 Watts
System Voltage 48.00 Watts
System Ampacity 300.00 Watts
Peak Load Watts
Spicific Appliance i.e. A/C 700.00 Watts
Calculated Result
Current Drawn 14.58 Amp
Max. Hrs. of Usage 20.57 Hours
Energy consumed by Fan 11520.00 Watt-Hr
Remaining Energy Stored 0.00 Watt-Hr

Note;
If Battery discharge rate is greater than Inverters max input
current, then a fuseor current protection device shall be in-
place before the Inverter. input.

Inverter Design Requirements


Battery Discharge Rate 2 C
Battery 🔋 Discharge Rate Current 600 Amp
Inverter Load
Peak Power 700.00 Watts
Nominal Voltage 48.00 Volt
Peak Current 14.58 Amp
Inverter Specification
Peak Power 3500 Watts
Rated Volts 48.00 Volt
Max Current 72.92 Amps

Panel Sizing
Panel Capacity 400 Watts
Panel Efficiency 90.00%
Battery Storage 11520.00 Watt-h
Solar Required Energy Generation 12800.00 Watt-h
Number of Panels 32 Panels