ControlEdge™ RTUs are powerful, modular and scalable controllers capable of all
remote automation and control applications. They provide improved management of
field assets through simplified and efficient remote monitoring, diagnostics, and
management. Reduce equipment monitoring and diagnostics from hours to minutes.
Experion® SCADA configuration time is reduced by 80%.
The follow-on effect of consuming less power is that there is less Inputs / Outputs
heat produced. This, coupled with an aluminium body and HART Enabled I/O Modules
designed thermal paths, means ControlEdge RTU has less ControlEdge RTU supports onboard and expansion I/O modules.
component stress which equates to higher reliability. Even in
tropical and desert environments, either minimal or no cooling is 28 Channel Mixed I/O Module:
required. Channel type Qty
Endures Tough Environments Analog Inputs: 8
ControlEdge RTU has been designed to withstand the toughest Analog Outputs: 2
environments, with an operating temperature range of -40 to
Digital Inputs: 10
75°C in humidity of 5% to 95%. Most other RTUs only go up to
Digital Outputs: 6
70°C. ControlEdge RTU has conformal coating to G3 and is
hazardous area certified to FM/CSA Class I Division 2, IECEx Pulse Inputs: 2
Zone 2 and ATEX Zone 2. By having built-in HART, ControlEdge RTU has no requirement
for separate expensive and power consuming HART I/O modules
75°C
or third party components.
70 Wireless I/O
By connecting a Field Device Access Point (FDAP), ControlEdge
RTU provides an onboard Wireless I/O solution for ISA100
devices. These wireless devices appear as native I/O. They are
RTUs are typically placed next to metal infrastructure such as
programmed and managed with the same configuration tool,
pipelines, so to reduce risk of transient surges, every I/O channel
ControlEdge Builder. You benefit from the same smart device
and every communication port on ControlEdge RTU has transient
capabilities as wired smart devices. Wireless I/O is effective
suppression.
when traditional wiring is expensive, difficult or at risk of damage.
High Performance Controller
The Value of Smart Data: HART & Wireless Devices
With modern processors, ControlEdge RTU has the power for Distributed operations can require crews of field operators that
today’s applications and spare reserve to meet tomorrow’s travel each day over long distances and dangerous terrain.
needs. ControlEdge RTU comes in two forms: Non-redundant ControlEdge RTU can help bring that requirement to an end. It is
controller with onboard I/O module and redundant controller. not only a large operating expense, but is also unsafe —and that
Both support expansion I/O modules. is just the trip to site. The traditional RTU strengths of data
logging and good sub-system communications with local devices,
Native Controller Redundancy
alongside smart device integration with HART or Wireless I/O, is
Honeywell’s redundancy is ready to go. There is no need to
enabling better fault modeling, both direct on the RTUs and at
program any differently from a non-redundant controller.
central locations. This means that each Field Operator is much
ControlEdge RTU takes away the complexity. No additional
more productive and can manage more remote sites than without
infrastructure is required to synchronize the data between CPMs
the implementation of ControlEdge RTU.
and to connect with I/O modules.
On-board Applications
Robust Data Logging Ensures Data Availability
ControlEdge RTU has data logging capabilities to record values
to data files in flash memory or the onboard SD card, (optional),
supporting up to 32GB of data. This ensures important data is
never lost and is available for future analysis. The data files can
be retrieved remotely through ControlEdge Builder or a utility and
Figure 4. Positive identification on removable terminals
then displayed or imported by many Windows applications.
ControlEdge RTU can log data continuously at a pre-defined
interval, or data logging can be event-triggered.
Meter Runs turn your RTU into a Flow Computer / EFM
ControlEdge RTU Meter Run option provides an API21.1
compliant gas custody transfer solution. Meter Runs work
alongside the rest of the RTU control program and are easily
configured with a 5 step wizard. Data logs and audit trails can be
imported by Experion for use in gas management systems. They
are also available through Enron Modbus protocol.
Remote Diagnosis
Just as important as being able to remotely program and upgrade
ControlEdge RTU is being able to remotely diagnose the health
of the RTU. ControlEdge Builder provides a high definition
analysis of the health scenario, leading to fewer site visits.
Ladder Diagram (LD) Standard System Status Displays & Alarms for ControlEdge
RTU hardware
Function Block Diagram (FBD)
Meter templates aligned to ControlEdge RTU Meter Runs
Structured Text (ST)
Instruction List (IL)
Sequential Function Chart (SFC)
In addition to the basic function blocks that come with an IEC
61131-3 environment, ControlEdge Builder includes Honeywell
designed function blocks derived from our extensive industry
experience and family of market leading automation controllers.
Function blocks include PID, Device Control, Auto Manual, Fan
Out, Ratio Control, Position Proportional, Totalizer and
AGA/API/IEC gas and liquids calculations, just to name just a
few. There are also ControlEdge RTU specific function blocks
such as HART Command 3, ‘read dynamic variables’ and HART
Command 48, ‘read diagnostics status’.