0% found this document useful (0 votes)
37 views4 pages

National Intumescent Paint WB

National Intumescent Paint WB is a water-based, single-component intumescent coating that provides up to 4 hours of fire resistance for walls and concrete surfaces. It is easy to apply, nonflammable, and complies with various regulatory standards for VOC and fire resistance. The product is available in multiple packaging sizes and has specific application and storage guidelines to ensure optimal performance.

Uploaded by

Saad Muzaffar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views4 pages

National Intumescent Paint WB

National Intumescent Paint WB is a water-based, single-component intumescent coating that provides up to 4 hours of fire resistance for walls and concrete surfaces. It is easy to apply, nonflammable, and complies with various regulatory standards for VOC and fire resistance. The product is available in multiple packaging sizes and has specific application and storage guidelines to ensure optimal performance.

Uploaded by

Saad Muzaffar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

NATIONAL INTUMESCENT PAINT WB

Water Based Intumescent Coating Technical data sheet

Product description
National Intumescent Paint WB is a single component, water based, air drying, intumescent coating. It is
designed to protect walls and concrete surface. It is certified for fire resistance classification: EI 240 as per EN
1364-1:2000 up to 4 hours.

Physical properties
Finish / Colors Matt – White
Volume Solid – ASTM D 2697 54 ± 2%
Flash Point – ASTM D 3278 Nonflammable
VOC – ASTM D 3960 < 20 grams/ liter

Usage data Dry film thickness per Wet film thickness per Theoretical spreading rate
coat (µ) coat (µ) (m2/l)

Range 200 - 300 370 - 555 1.8 - 2.7

Recommended 250 463 2.16

Advantages and Intended use


• Can be used over walls and concrete surface of both industrial or commercial buildings.
• Provides up to 4 hours of fire resistance.
• Single pack and easy to apply.
• Can be applied over various single pack or two pack primers.

Performance and Certifications

• This product complies with local regulatory standards for VOC.


• Meets requirements of C5 exposure, as outlined in ISO 12944 - 5 when used as part of a coating system.
• Tested and certified by LGAI TECHNOLOGICAL CENTER S.A. (APPLUS) as per EN 1364-1:2000 classification
and testing standard, up to 4 hours of fire resistance.
• Certified by Directorate of Civil Defense, Dubai, UAE for Classification EN 1364-1:2000 up to 4 hours.

ISO 9001, 14001 & 45001 Issued: 1/24


CERTIFIED FACTORY
www.nationalpaints.com Page 1 of 4
NATIONAL INTUMESCENT PAINT WB
Water Based Intumescent Coating Technical data sheet

Application data
Mixing Ratio Single pack
Pot life Not applicable
Airless spray Pressure at nozzle : 2000 - 2500 psi.
Nozzle size : 0.013 - 0.021 in
Spray angle: 40 - 80 degree.
Volume of thinner 5-10%
Air assisted gun Pressure at nozzle : 35 - 50 psi.
Nozzle size : 1.8 - 2.2mm
Spray angle: 40 - 80 degree.
Volume of thinner 10 - 15%
Brush /Roller Applicable for inaccessible area, corners and edges. Multiple coat may be
required for desired film thickness. Volume of thinner : 5 - 10%
Conditions Humidity : Below 85% RH, Temperature of the substrate should be at least 3°C
above the dew point of the air. Application temperature : min 10°C, maximum
45°C
Thinner /Cleaner Water

Storage and handling

Storage instruction Product must be stored according to local regulations and manufacturer
recommendation. Recommended to store at 30°C, away from direct sunlight,
heat, source of ignition and exposure to water or rain, within a well ventilated
place.

Packaging Available in 0.9Liter, 3.6 Liters and 18 Liters.

Shelf life 6 months in original sealed drums from the date of manufacture when stored
at or below 30°C

.
ISO 9001, 14001 & 45001
Issued: 1/24
CERTIFIED FACTORY
www.nationalpaints.com Page 2 of 4
NATIONAL INTUMESCENT PAINT WB
Water Based Intumescent Coating Technical data sheet

Curing -time Substrate temperature


10°C 20°C 30°C 40°C
Touch dry 24 hours 10 hours 5 hours 3 hours
Dry to Handle 48 hours 32 hours 24 hours 20 hours
Recoat interval Min: 48 hours Min: 32 hours Min: 24 hours Min: 20 hours
Max: Indefinite* Max: Indefinite* Max: Indefinite* Max: Indefinite*

Drying and curing times are determined under controlled temperatures and relative humidity below 85 %,
and at average of the DFT range for the product and should be considered as guidelines only. The actual
drying time/times may be shorter or longer, depending on film thickness, temperature, ventilation, humidity,
preceding paint system etc.

*The surface should be dry and free from contaminants prior to over coating. The best intercoat adhesion is
achieved when the subsequent coat is applied before the preceding coat is fully cured. When recoating with
products, maximum recoat interval is limited. After prolonged exposure it may be necessary to roughen the
surface to ensure intercoat adhesion. When in doubt, consult your nearest National paints representative.

Surface preparation
Coated surface
All surfaces should be clean, dry and free from contamination. Surfaces should be treated in accordance with
ISO 8504:2000. Ensure compatibility of the coated substrates with the selected paint system. If the remaining
part of the existing coating system needs to be sweep-blasted, fine abrasive shall be used to avoid damage to
the coating system. When recoating aged coated substrates, damaged areas must be removed back to a firm
edge. Light abrade or sweep-blast the surface in order to provide a physical key for adhesion.

.
ISO 9001, 14001 & 45001
Issued: 1/24
CERTIFIED FACTORY
www.nationalpaints.com Page 3 of 4
NATIONAL INTUMESCENT PAINT WB
Water Based Intumescent Coating Technical data sheet

Minor repair / Touch-up


All surfaces should be clean, dry and free from contamination. Surfaces should be treated in accordance with
ISO 8504:2000. Any corroded areas should be prepared by power-tool cleaning or manual cleaning.
Power-tool cleaning to min. St 2, preferably St 3 (ISO 8501-1:2007). Care shall be taken to ensure that power-
tool cleaning does not polish the steel surface. If the surface being prepared lies adjacent to a coated surface,
the power tool cleaning shall overlap the coated surface by at least 25 mm and the coated surface shall be
feathered.

Typical coating system

Primer National Acrylic Primer (WB) 40µ


Second coat National Intumescent Paint WB As per fire protection requirement.
Finish coat National Acrylic Top coat (WB) OR 2 X 40µ
National Polyuréthane Top coat
Other Information
• Film thickness can vary depending upon desired fire protection window.
• Consult National Paint representative for appropriate system suggestions.
• Recommendations given by National Paints representative will supersede generic recommendations given
in the Product Data Sheet.

Safety and Precautions


• Avoid skin and eye contact by wearing overalls, gloves, goggles, and mask etc.
• Eyes: In the event of accidental splashes, flush eye with water immediately and obtain medical advice.
• Skin: Wash skin thoroughly with soap and water or medically approved cleaner.
• Avoid inhalation of paint mist by wearing suitable mask. In the event of ingestion seek medical attention
immediately.
• Painting must be carried out in well-ventilated area. Local safety regulation need to be followed.

NOTE: We warranty only the quality of our product and this data sheet is based on results obtained from experience and tests. We
reserve the right to change data without prior notice. For safety details kindly refer safety data sheet.

ISO 9001, 14001 & 45001 Issued: 1/24


CERTIFIED FACTORY
www.nationalpaints.com Page 4 of 4

You might also like